Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39011961

RESUMEN

INTRODUCTION: Patients with viral myocarditis can present with challenging life-threatening arrhythmias. Catheter ablation can be a life-saving procedure in some patients with recurrent drug-refractory ventricular arrhythmias. METHODS AND RESULTS: A patient with three prior ablations targeting two different monomorphic ventricular tachycardias (MMVTs) presented with recurrent ventricular tachycardia (VT). Consequently, he underwent epicardial mapping with adjuvant AI-enabled CT images with the creation of a three-dimensional model, which demonstrated a midmyocardial scar. Fractionated potentials were noted during mapping in this region, and entrainment suggested an inner loop. Interestingly, pacing showed two different QRS morphologies identical to his previously ablated VTs with a long stim-QRS at this region. Epicardial ablation carried on during the VT successfully terminated it, but the VT remained inducible and required endocardial ablation to make it noninducible. CONCLUSION: This case emphasizes the importance of recognizing possible three-dimensional VT circuits in some patients and the need to understand and target mid-myocardial substrate from both the endocardium and epicardium to achieve the elimination of the VT circuits.

2.
J Cardiovasc Electrophysiol ; 35(1): 44-57, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37927196

RESUMEN

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used during left atrial appendage occlusion (LAAO) as an alternative to transesophageal echocardiography (TEE). The objective of this study is to evaluate the impact of ICE versus TEE guidance during LAAO on procedural characteristics and acute outcomes, as well the presence of peri-device leaks and residual septal defects during follow-up. METHODS: All studies comparing ICE-guided versus TEE-guided LAAO were identified. The primary outcomes were procedural efficacy and occurrence of procedure-related complications. Secondary outcomes included lab efficiency (defined as a reduction in in-room time), procedural time, fluoroscopy time, and presence of peri-device leaks and residual interatrial septal defects (IASD) during follow-up. RESULTS: Twelve studies (n = 5637) were included. There were no differences in procedural success (98.3% vs. 97.8%; OR 0.73, 95% CI 0.42-1.27, p = .27; I2 = 0%) or adverse events (4.5% vs. 4.4%; OR 0.81 95% CI 0.56-1.16, p = .25; I2 = 0%) between the ICE-guided and TEE-guided groups. ICE guidance reduced in in-room time (mean-weighted 28.6-min reduction in in-room time) without differences in procedural time or fluoroscopy time. There were no differences in peri-device leak (OR 0.93, 95% CI 0.68-1.27, p = 0.64); however, an increased prevalence of residual IASD was observed with ICE-guided versus TEE-guided LAAO (46.3% vs. 34.2%; OR 2.23, 95% CI 1.05-4.75, p = 0.04). CONCLUSION: ICE guidance is associated with similar procedural efficacy and safety, but could result in improved lab efficiency (as established by a significant reduction in in-room time). No differences in the rate of periprocedural leaks were found. A higher prevalence of residual interatrial septal defects was observed with ICE guidance.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ecocardiografía Transesofágica , Resultado del Tratamiento
3.
J Cardiovasc Electrophysiol ; 35(7): 1329-1339, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38664888

RESUMEN

BACKGROUND: The efficacy and safety of adjunctive low-voltage area (LVA) ablation on outcomes of catheter ablation (CA) for atrial fibrillation (AF) remains uncertain. METHODS: PubMed, Embase, Cochrane Library, and ClinicalTrials.gov were searched for randomized controlled trials (RCTs) comparing CA with versus without LVA ablation for patients with AF. Risk ratios (RR) with 95% confidence intervals (CI) were pooled with a random-effects model. Our primary endpoint was recurrence of atrial tachyarrhythmia (ATA), including AF, atrial flutter, or atrial tachycardia. We used R version 4.3.1 for all statistical analyses. RESULTS: Our meta-analysis included 10 RCTs encompassing 1780 patients, of whom 890 (50%) were randomized to LVA ablation. Adjunctive LVA ablation significantly reduced recurrence of ATA (RR 0.76; 95% CI 0.67-0.88; p < .01) and reduced the number of redo ablation procedures (RR 0.54; 95% CI 0.35-0.85; p < .01), as compared with conventional ablation. Among 691 (43%) patients with documented LVAs on baseline substrate mapping, adjunctive LVA ablation substantially reduced ATA recurrences (RR 0.57; 95% CI 0.38-0.86; p < .01). There was no significant difference between groups in terms of periprocedural adverse events (RR 0.78; 95% CI 0.39-1.56; p = .49). CONCLUSIONS: Adjunctive LVA ablation is an effective and safe strategy for reducing recurrences of ATA among patients who undergo CA for AF.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Ablación por Catéter/efectos adversos , Resultado del Tratamiento , Masculino , Factores de Riesgo , Femenino , Persona de Mediana Edad , Frecuencia Cardíaca , Anciano , Factores de Tiempo
5.
Artículo en Inglés | MEDLINE | ID: mdl-38544808

RESUMEN

Left atrial appendage occlusion (LAAO) is a suitable alternative to oral anticoagulant therapy to prevent stroke in patients with AF. Most procedures are performed under transoesophageal echocardiography (TOE) guidance, which facilitates transseptal puncture, reduces the risk of procedurerelated complications and provides an additional method for device selection and real-time monitoring during device deployment. However, TOE has significant shortcomings, including the need for general anaesthesia/deep sedation as well as a significant risk of procedure-related adverse events. More recently, intracardiac echocardiography has been proposed as an alternative to TOE guidance during LAAO procedures. In this review, we summarise the available evidence as well as providing a step-by-step approach for intracardiac echocardiography-guided LAAO.

6.
Heart Rhythm ; 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38490601

RESUMEN

BACKGROUND: Left bundle branch block (LBBB) represents a frequently encountered conduction system disorder. Despite its widespread occurrence, a continual dilemma persists regarding its intricate association with underlying cardiomyopathy and its pivotal role in the initiation of dilated cardiomyopathy. The pathologic alterations linked to LBBB-induced cardiomyopathy (LBBB-CM) have remained elusive. OBJECTIVE: This study sought to investigate the chronologic dynamics of LBBB to left ventricular dysfunction and the pathologic mechanism of LBBB-CM. METHODS: LBBB model was established through main left bundle branch trunk ablation in 14 canines. All LBBB dogs underwent transesophageal echocardiography and electrocardiography before ablation and at 1 month, 3 months, 6 months, and 12 months after LBBB induction. Single-photon emission computed tomography imaging was performed at 12 months. We then harvested the heart from all LBBB dogs and 14 healthy adult dogs as normal controls for anatomic observation, Purkinje fiber staining, histologic staining, and connexin43 protein expression quantitation. RESULTS: LBBB induction caused significant fibrotic changes in the endocardium and mid-myocardium. Purkinje fibers exhibited fatty degeneration, vacuolization, and fibrosis along with downregulated connexin43 protein expression. During a 12-month follow-up, left ventricular dysfunction progressively worsened, peaking at the end of the observation period. The association between myocardial dysfunction, hypoperfusion, and fibrosis was observed in the LBBB-afflicted canines. CONCLUSION: LBBB may lead to profound myocardial injury beyond its conduction impairment effects. The temporal progression of left ventricular dysfunction and the pathologic alterations observed shed light on the complex relationship between LBBB and cardiomyopathy. These findings offer insights into potential mechanisms and clinical implications of LBBB-CM.

7.
JACC Clin Electrophysiol ; 10(2): 295-305, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38127008

RESUMEN

BACKGROUND: Left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP) are considered to be acceptable as LBBAP strategies. Differences in clinical outcomes between LBBP and LVSP are yet to be determined. OBJECTIVES: The purpose of this study was to compare the outcomes of LBBP vs LVSP vs BIVP for CRT. METHODS: In this prospective multicenter observational study, LBBP was compared with LVSP and BIVP in patients undergoing CRT. The primary composite outcome was freedom from heart failure (HF)-related hospitalization and all-cause mortality. Secondary outcomes included individual components of the primary outcome, postprocedural NYHA functional class, and electrocardiographic and echocardiographic parameters. RESULTS: A total of 415 patients were included (LBBP: n = 141; LVSP: n = 31; BIVP: n = 243), with a median follow-up of 399 days (Q1-Q3: 249.5-554.8 days). Freedom from the primary composite outcomes was 76.6% in the LBBP group and 48.4% in the LVSP group (HR: 1.37; 95% CI: 1.143-1.649; P = 0.001), driven by a 31.4% absolute increase in freedom from HF-related hospitalizations (83% vs 51.6%; HR: 3.55; 95% CI: 1.856-6.791; P < 0.001) without differences in all-cause mortality. LBBP was also associated with a higher freedom from the primary composite outcome compared with BIVP (HR: 1.43; 95% CI: 1.175-1.730; P < 0.001), with no difference between LVSP and BIVP. CONCLUSIONS: In patients undergoing CRT, LBBP was associated with improved outcomes compared with LVSP and BIVP, while outcomes between BIVP and LVSP are similar.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Estudios Prospectivos , Sistema de Conducción Cardíaco , Ventrículos Cardíacos , Electrocardiografía
8.
Artículo en Inglés | MEDLINE | ID: mdl-38819345

RESUMEN

BACKGROUND: Catheter ablation of ventricular tachycardia (VT) typically requires radiation exposure with its potential adverse health effects. A completely fluoroless ablation approach is achievable using a combination of electroanatomical mapping and intracardiac echocardiography. Nonetheless, data in patients undergoing VT ablation are limited. OBJECTIVES: This study aimed to determine the feasibility, efficacy, and safety of VT ablation in patients with structural heart disease using a zero-fluoroscopy approach. METHODS: This multicenter study included consecutive patients with ischemic and nonischemic cardiomyopathy undergoing fluoroless VT ablation. Patients requiring epicardial access or coronary angiography were excluded. RESULTS: Between 2017 and 2023 a total of 198 patients (aged 66.4 ± 13.4 years, 76% male, 48% ischemic) were included. Most patients (95.4%) underwent left ventricular (LV) mapping and/or ablation, which was conducted via transseptal route in 54.5% (n = 103), via retrograde aortic route in 43.4% (n = 82), and using a combined approach in 2.1% (n = 4). Two-thirds of patients had a cardiac device, including a biventricular device in 15%; 2 patients had a LV assist device, and 1 patient had a mechanical aortic valve prosthesis. The mean total procedural time was 211 ± 70 minutes, and the total radiofrequency time was 30 ± 22 minutes. During a follow-up period of 22 ± 18 months, the freedom from VT recurrence was 80%, and 7.6% of patients underwent a repeated ablation. Procedural-related complications occurred in 6 patients (3.0%). CONCLUSIONS: Fluoroless ablation of VT in structural heart disease is feasible, effective, and safe when epicardial mapping/ablation is not required.

9.
Artículo en Inglés | MEDLINE | ID: mdl-38668934

RESUMEN

BACKGROUND: Left bundle branch area pacing (LBBAP) has emerged as a physiological alternative pacing strategy to biventricular pacing (BIVP) in cardiac resynchronization therapy (CRT). We aimed to assess the impact of LBBAP vs. BIVP on all-cause mortality and heart failure (HF)-related hospitalization in patients undergoing CRT. METHODS: Studies comparing LBBAP and BIVP for CRT in patients with HF with reduced left ventricular ejection fraction (LVEF) were included. The coprimary outcomes were all-cause mortality and HF-related hospitalization. Secondary outcomes included procedural and fluoroscopy time, change in QRS duration, and change in LVEF. RESULTS: Thirteen studies (12 observational and 1 RCT, n = 3239; LBBAP = 1338 and BIVP = 1901) with a mean follow-up duration of 25.8 months were included. Compared to BIVP, LBBAP was associated with a significant absolute risk reduction of 3.2% in all-cause mortality (9.3% vs 12.5%, RR 0.7, 95% CI 0.57-0.86, p < 0.001) and an 8.2% reduction in HF-related hospitalization (11.3% vs 19.5%, RR 0.6, 95% CI 0.5-0.71, p < 0.00001). LBBAP also resulted in reductions in procedural time (mean weighted difference- 23.2 min, 95% CI - 42.9 to - 3.6, p = 0.02) and fluoroscopy time (- 8.6 min, 95% CI - 12.5 to - 4.7, p < 0.001) as well as a significant reduction in QRS duration (mean weighted difference:- 25.3 ms, 95% CI - 30.9 to - 19.8, p < 0.00001) and a greater improvement in LVEF of 5.1% (95% CI 4.4-5.8, p < 0.001) compared to BIVP in the studies that reported these outcomes. CONCLUSION: In this meta-analysis, LBBAP was associated with a significant reduction in all-cause mortality as well as HF-related hospitalization when compared to BIVP. Additional data from large RCTs is warranted to corroborate these promising findings.

10.
Artículo en Inglés | MEDLINE | ID: mdl-38842969

RESUMEN

BACKGROUND: Women respond more favorably to biventricular pacing (BIVP) than men. Sex differences in atrioventricular and interventricular conduction have been described in BIVP studies. Left bundle branch area pacing (LBBAP) offers advantages due to direct capture of the conduction system. We hypothesized that men could respond better to LBBAP than BIVP. OBJECTIVES: This study aims to describe the sex differences in response to LBBAP vs BIVP as the initial cardiac resynchronization therapy (CRT). METHODS: In this multicenter prospective registry, we included patients with left ventricular ejection fraction ≤35% and left bundle branch block or a left ventricular ejection fraction ≤40% with an expected right ventricular pacing exceeding 40% undergoing initial CRT with LBBAP or BIVP. The composite primary outcome was heart failure-related hospitalization and all-cause mortality. The primary safety outcome included all procedure-related complications. RESULTS: There was no significant difference in the primary outcome when comparing men and women receiving LBBAP (P = 0.46), whereas the primary outcome was less frequent in women in the BIVP group than men treated with BIVP (P = 0.03). The primary outcome occurred less frequently in men undergoing LBBAP (29.9%) compared to those treated with BIVP (46.5%) (P = 0.004). In women, the incidence of the primary endpoint was 24.14% in the LBBAP group and 36.2% in the BIVP group; however, this difference was not statistically significant (P = 0.23). Complication rates remained consistent across all groups. CONCLUSIONS: Men and women undergoing LBBAP for CRT had similar clinical outcomes. Men undergoing LBBAP showed a lower risk of heart failure-related hospitalizations and all-cause mortality compared to men undergoing BIVP, whereas there was no difference between LBBAP and BIVP in women.

11.
Heart Rhythm ; 2024 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-38768839

RESUMEN

BACKGROUND: The safety and long-term efficacy of radiofrequency (RF) catheter ablation (CA) of paroxysmal atrial fibrillation (PAF) has been well established. Contemporary techniques to optimize ablation delivery, reduce fluoroscopy use, and improve clinical outcomes have been developed. OBJECTIVE: The purpose of this study was to assess the contemporary real-world practice approach and short and long-term outcomes of RF CA for PAF through a prospective multicenter registry. METHODS: Using the REAL-AF (Real-world Experience of Catheter Ablation for the Treatment of Symptomatic Paroxysmal and Persistent Atrial Fibrillation; ClincalTrials.gov Identifier: NCT04088071) Registry, patients undergoing RF CA to treat PAF across 42 high-volume institutions and 79 experienced operators were evaluated. The procedures were performed using zero or reduced fluoroscopy, contact force sensing catheters, wide area circumferential ablation, and ablation index as a guide with a target of 380-420 for posterior and 500-550 for anterior lesions. The primary efficacy outcome was freedom from all-atrial arrhythmia recurrence at 12 months. RESULTS: A total of 2470 patients undergoing CA from January 2018 to December 2022 were included. Mean age was 65.2 ±11.14 years, and 44% were female. Most procedures were performed without fluoroscopy (71.5%), with average procedural and total RF times of 95.4 ± 41.7 minutes and 22.1±11.8 minutes, respectively. At 1-year follow-up, freedom from all-atrial arrhythmias was 81.6% with 89.7% of these patients off antiarrhythmic drugs. No significant difference was identified comparing pulmonary vein isolation vs pulmonary vein isolation plus ablation approaches. The complication rate was 1.9%. CONCLUSION: Refinement of RF CA to treat PAF using contemporary tools, standardized protocols, and electrophysiology laboratory workflows resulted in excellent short- and long-term clinical outcomes.

12.
Am J Ther ; 20(5): 581-4, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-21519223

RESUMEN

Pyroglutamic acidemia is an uncommon metabolic disorder, which is usually diagnosed at early ages. The mechanism of action is thought to be glutathione depletion, and its clinical manifestations consist of hemolytic anemia, mental retardation, ataxia, and chronic metabolic acidosis. However, an acquired form has been described in adult patients, who usually present with confusion, respiratory distress, and high anion gap metabolic acidosis (HAGMA). It is also associated with many conditions, including chronic acetaminophen consumption. A 68-year-old white male, with chronic acetaminophen use presented to our service on multiple occasions with severe HAGMA. The patient was admitted to the intensive care unit and required mechanical ventilation and aggressive supportive measures. After ruling out the most frequent etiologies for his acid-base disorder and considering the long history of Tylenol ingestion, his 5-oxiproline (pyroglutamic acid) levels were sent to diagnose pyroglutamic acidemia. Clinicians need to be aware of this cause for metabolic acidosis since it might be a more common metabolic disturbance in compromised patients than would be expected. Subjects with HAGMA that cannot be explained by common causes should be tested for the presence of 5-oxoproline. Discontinuation of the offending drug is therapeutic.


Asunto(s)
Acidosis/diagnóstico , Ácido Pirrolidona Carboxílico/sangre , Acetaminofén/administración & dosificación , Acidosis/epidemiología , Lesión Renal Aguda/epidemiología , Anciano , Analgésicos no Narcóticos/administración & dosificación , Humanos , Masculino
13.
Heart Rhythm ; 20(12): 1674-1681, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37598986

RESUMEN

BACKGROUND: Infection is the most dreaded complication of cardiac implantable electronic devices (CIEDs), particularly in patients undergoing high-risk procedures (eg, generator change, device upgrade, lead/pocket revision). OBJECTIVE: The purpose of this study was to describe the impact of chlorhexidine gluconate (CHG) pocket lavage in high-risk procedures. METHODS: Patients from a prospective multicenter registry undergoing high-risk procedures were included. CHG lavage was performed by irrigating the generator pocket with 20 cc of 2% CHG without alcohol followed by and normal saline (NS) irrigation. Only NS irrigation was performed in the comparison group. The primary efficacy outcome was CIED-related infection at 12 months. The primary safety outcome was any CHG-associated adverse event. The secondary outcome was CIED infection during long-term follow-up. Propensity score matching (PSM) analysis was performed for the primary efficacy outcome. RESULTS: A total of 1504 patients were included. At 12-month follow-up, the primary efficacy outcome occurred in 4 of 904 CHG (0.4%) and 14 of 600 NS (2.3%) subjects (log-rank P = .005). On multivariate analysis, the use of CHG irrigation was associated with a lower risk of infection at 1-year follow-up (Cox proportional hazard ratio [HR] 0.138; 95% confidence interval [CI] 0.04-0.45; P = .001). This effect persisted during long-term follow-up. PSM demonstrated a significant reduction in CIED-related infection for the CHG group (0.2% vs 2.5%; Cox proportional HR 0.08; 95% CI 0.01-0.59; P = .014). No adverse events were associated with the use of CHG. CONCLUSION: CHG lavage during high-risk procedures was associated with a reduction in CIED-related infections without any adverse events reported. The benefits of CHG lavage were observed even during long-term follow up and in PSM analysis.


Asunto(s)
Desfibriladores Implantables , Cardiopatías , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Humanos , Desfibriladores Implantables/efectos adversos , Cardiopatías/etiología , Marcapaso Artificial/efectos adversos , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/prevención & control , Irrigación Terapéutica
14.
Artículo en Inglés | MEDLINE | ID: mdl-38173800

RESUMEN

Cardiac resynchronisation therapy (CRT) reduces the risk of heart failure-related hospitalisations and all-cause mortality, as well as improving quality of life and functional status in patients with persistent heart failure symptoms despite optimal medical treatment and left bundle branch block. CRT has traditionally been delivered by implanting a lead through the coronary sinus to capture the left ventricular epicardium; however, this approach is associated with significant drawbacks, including a high rate of procedural failure, phrenic nerve stimulation, high pacing thresholds and lead dislodgement. Moreover, a significant proportion of patients fail to derive any significant benefit. Left bundle branch area pacing (LBBAP) has recently emerged as a suitable alternative to traditional CRT. By stimulating the cardiac conduction system physiologically, LBBAP can result in a more homogeneous left ventricular contraction and relaxation, thus having the potential to improve outcomes compared with conventional CRT strategies. In this article, the evidence supporting the use of LBBAP in patients with heart failure is reviewed.

15.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1515-1526, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37204358

RESUMEN

BACKGROUND: Same-day discharge (SDD) after catheter ablation of atrial fibrillation (AF) has been widely adopted. Nevertheless, planned SDD has been performed by using subjective criteria rather than standardized protocols. OBJECTIVES: The goal of this study was to determine the efficacy and safety of the previously described SDD protocol in a prospective multicenter study. METHODS: Using the REAL-AF (Real-world Experience of Catheter Ablation for the Treatment of Paroxysmal and Persistent Atrial Fibrillation) SDD protocol eligibility criteria (stable anticoagulation, no bleeding history, left ventricular ejection fraction >40%, no pulmonary disease, no procedures within 60 days, and body mass index <35 kg/m2), operators prospectively determined whether patients undergoing ablation of AF were candidates for SDD (SDD vs non-SDD groups). Successful SDD was achieved if the patient met the protocol discharge criteria. The primary efficacy endpoint was the success rate of SDD. The primary safety endpoints were readmission rates as well as acute and subacute complications. The secondary endpoints included procedural characteristics and freedom from all-atrial arrhythmias. RESULTS: A total of 2,332 patients were included. The REAL-AF SDD protocol identified 1,982 (85%) patients as potential candidates for SDD. The primary efficacy endpoint was achieved in 1,707 (86.1%) patients. The readmission rate for SDD vs non-SDD group was similar (0.8% vs 0.9%; P = 0.924). The SDD group had a lower acute complication rate than the non-SDD group (0.8% vs 2.9%; P < 0.001), and there was no difference in the subacute complication rate between groups (P = 0.513). Freedom from all-atrial arrhythmias was comparable between groups (P = 0.212). CONCLUSIONS: In this large, multicenter prospective registry, the use of a standardized protocol showed the safety of SDD after catheter ablation of paroxysmal and persistent AF. (Real-world Experience of Catheter Ablation for the Treatment of Paroxysmal and Persistent Atrial Fibrillation [REAL-AF]; NCT04088071).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Alta del Paciente , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
16.
J Clin Med ; 12(7)2023 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-37048679

RESUMEN

Patients with multiple myeloma (MM) are at a high risk for developing cardiovascular complications. Global longitudinal strain (GLS) can detect early functional impairment before structural abnormalities develop. It remains unknown if reduced GLS is associated with reduced survival in patients with MM. We conducted a retrospective cohort analysis of patients diagnosed with MM between 1 January 2000 and 31 December 2017 at our institution. Patients with a 2D transthoracic echocardiogram completed within 1 year of MM diagnosis, left ventricular ejection fraction (LVEF) greater than 40%, and no history of myocardial infarction prior to MM diagnosis were included. GLS was measured using an artificial-intelligence-powered software (EchoGo Core), with reduced GLS defined as an absolute value of <18%. The primary outcome of interest was overall survival since myeloma diagnosis. Our cohort included 242 patients with a median follow up of 4.28 years. Fifty-two (21.5%) patients had reduced average GLS. Patients with reduced GLS were more likely to have an IVSd ≥ 1.2cm, E/E' > 9.6, LVEF/GLS > 4.1, higher LV mass index, and low-voltage ECG. A Total of 126 (52.1%) deaths occurred during follow-up. Overall survival was lower among patients with reduced GLS (adjusted HR: 1.81, CI: 1.07-3.05).

17.
JACC Clin Electrophysiol ; 9(12): 2573-2583, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37804258

RESUMEN

BACKGROUND: High-power short-duration (HPSD) radiofrequency ablation of atrial fibrillation (AF) increases first-pass pulmonary vein isolation (PVI) and freedom from atrial arrhythmias while decreasing procedural time. However, the optimal power setting in terms of safety and efficacy has not been determined. OBJECTIVES: This study compared the procedural characteristics and clinical outcomes of 50-W vs 40-W during HPSD ablation of paroxysmal AF. METHODS: Patients from the REAL-AF prospective multicenter registry (Real-World Experience of Catheter Ablation for Treatment of Symptomatic Paroxysmal and Persistent Atrial Fibrillation) undergoing HPSD ablation of paroxysmal AF, either using 50-W or 40-W, were included. The primary efficacy outcome was freedom from all-atrial arrhythmias. The primary safety outcome was the occurrence of any procedural complication at 12 months. Secondary outcomes included procedural characteristics, AF-related symptoms, and the occurrence of transient ischemic attack or stroke at 12 months. RESULTS: A total of 383 patients were included. Freedom from all-atrial arrhythmias at 12 months was 80.7% in the 50-W group and 77.3% in the 40-W group (Log-rank P = 0.387). The primary safety outcome occurred in 3.7% of patients in the 50-W group vs 2.8% in the 40-W group (P = 0.646). The 50-W group had a higher rate of first-pass PVI (82.3% vs 76.2%; P = 0.040) as well as shorter procedural (67 minutes [IQR: 54-87.5 minutes] vs 93 minutes [IQR: 80.5-111 minutes]; P < 0.001) and radiofrequency ablation times (15 minutes [IQR: 11.4-20 minutes] vs 27 minutes [IQR: 21.5-34.6 minutes]; P < 0.001) than the 40-W group. CONCLUSIONS: There was no significant difference in freedom from all-atrial arrhythmias or procedural safety outcomes between 50-W and 40-W during HPSD ablation of paroxysmal AF. The use of 50-W was associated with a higher rate of first-pass PVI as well as shorter procedural times.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Humanos , Estudios Prospectivos , Recurrencia Local de Neoplasia/etiología , Factores de Tiempo , Ablación por Catéter/efectos adversos
18.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1487-1499, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37486280

RESUMEN

BACKGROUND: Epicardial access (EA) has emerged as an increasingly important approach for the treatment of ventricular arrhythmias and to perform other interventional cardiology procedures. EA is frequently underutilized because the current approach is challenging and carries a high risk of life-threatening complications. OBJECTIVE: The purpose of this study was to determine the efficacy and safety of the SAFER (Sustained Apnea for Epicardial Access With Right Ventriculography) epicardial approach. METHODS: Consecutive patients who underwent EA with the SAFER technique were included in this multicenter study. The primary efficacy outcome was the successful achievement of EA. The primary safety outcomes included right ventricular (RV) perforation, major hemorrhagic pericardial effusion (HPE), and bleeding requiring surgical intervention. Secondary outcomes included procedural characteristics and any complications. Our results were compared with those from previous studies describing other EA techniques to assess differences in outcomes. RESULTS: A total of 105 patients undergoing EA with the SAFER approach from June 2021 to February 2023 were included. EA was used for ventricular tachycardia ablation in 98 patients (93.4%), left atrial appendage closure in 6 patients (5.7%), and phrenic nerve displacement in 1 patient (0.9%). EA was successful in all subjects (100%). The median time to EA was 7 minutes (IQR: 5-14 minutes). No cases of RV perforation, HPE, or need of surgical intervention were observed in this cohort. Comparing our results with previous studies about EA, the SAFER epicardial approach resulted in a significant reduction in major pericardial bleeding. CONCLUSIONS: The SAFER epicardial approach is a simple, efficient, effective, and low-cost technique easily reproducible across multiple centers. It is associated with lower complication rates than previously reported techniques for EA.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Lesiones Cardíacas , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirugía , Apnea , Arritmias Cardíacas , Pericardio/diagnóstico por imagen , Pericardio/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Hemorragia
19.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1568-1581, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37212761

RESUMEN

BACKGROUND: Left bundle branch area pacing (LBBAP) for cardiac resynchronization therapy (CRT) is an alternative to biventricular pacing (BiVp). OBJECTIVES: The purpose of this study was to compare the outcomes between LBBAP and BiVp as an initial implant strategy for CRT. METHODS: In this prospective multicenter, observational, nonrandomized study, first-time CRT implant recipients with LBBAP or BiVp were included. The primary efficacy outcome was a composite of heart failure (HF)-related hospitalization and all-cause mortality. The primary safety outcomes were acute and long-term complications. Secondary outcomes included postprocedural New York Heart Association functional class and electrocardiographic and echocardiographic parameters. RESULTS: A total of 371 patients (median follow-up of 340 days [IQR: 206-477 days]) were included. The primary efficacy outcome occurred in 24.2% in the LBBAP vs 42.4% in the BiVp (HR: 0.621 [95% CI: 0.415-0.93]; P = 0.021) group, driven by a reduction in HF-related hospitalizations (22.6% vs 39.5%; HR: 0.607 [95% CI: 0.397-0.927]; P = 0.021) without significant difference in all-cause mortality (5.5% vs 11.9%; P = 0.19) or differences in long-term complications (LBBAP: 9.4% vs BiVp: 15.2%; P = 0.146). LBBAP resulted in shorter procedural (95 minutes [IQR: 65-120 minutes] vs 129 minutes [IQR: 103-162 minutes]; P < 0.001) and fluoroscopy times (12 minutes [IQR: 7.4-21.1 minutes] vs 21.7 minutes [IQR: 14.3-30 minutes]; P < 0.001), shorter QRS duration (123.7 ± 18 milliseconds vs 149.3 ± 29.1 milliseconds; P < 0.001), and higher postprocedural left ventricular ejection fraction (34.1% ± 12.5% vs 31.4% ± 10.8%; P = 0.041). CONCLUSIONS: LBBAP as an initial CRT strategy resulted in a lower risk of HF-related hospitalizations compared to BiVp. A reduction in procedural and fluoroscopy times, shorter paced QRS duration, and improvements in left ventricular ejection fraction compared with BiVp were observed.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Volumen Sistólico , Estudios Prospectivos , Función Ventricular Izquierda , Resultado del Tratamiento , Insuficiencia Cardíaca/terapia
20.
JACC Clin Electrophysiol ; 9(8 Pt 2): 1543-1554, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37294263

RESUMEN

BACKGROUND: High-frequency, low-tidal-volume (HFLTV) ventilation is a safe and simple strategy to improve catheter stability and first-pass isolation during pulmonary vein (PV) isolation. However, the impact of this technique on long-term clinical outcomes has not been determined. OBJECTIVES: This study sought to assess acute and long-term outcomes of HFLTV ventilation compared with standard ventilation (SV) during radiofrequency (RF) ablation of paroxysmal atrial fibrillation (PAF). METHODS: In this prospective multicenter registry (REAL-AF), patients undergoing PAF ablation using either HFLTV or SV were included. The primary outcome was freedom from all-atrial arrhythmia at 12 months. Secondary outcomes included procedural characteristics, AF-related symptoms, and hospitalizations at 12 months. RESULTS: A total of 661 patients were included. Compared with those in the SV group, patients in the HFLTV group had shorter procedural (66 [IQR: 51-88] minutes vs 80 [IQR: 61-110] minutes; P < 0.001), total RF (13.5 [IQR: 10-19] minutes vs 19.9 [IQR: 14.7-26.9] minutes; P < 0.001), and PV RF (11.1 [IQR: 8.8-14] minutes vs 15.3 [IQR: 12.4-20.4] minutes; P < 0.001) times. First-pass PV isolation was higher in the HFLTV group (66.6% vs 63.8%; P = 0.036). At 12 months, 185 of 216 (85.6%) in the HFLTV group were free from all-atrial arrhythmia, compared with 353 of 445 (79.3%) patients in the SV group (P = 0.041). HLTV was associated with a 6.3% absolute reduction in all-atrial arrhythmia recurrence, lower rate of AF-related symptoms (12.5% vs 18.9%; P = 0.046), and hospitalizations (1.4% vs 4.7%; P = 0.043). There was no significant difference in the rate of complications. CONCLUSIONS: HFLTV ventilation during catheter ablation of PAF improved freedom from all-atrial arrhythmia recurrence, AF-related symptoms, and AF-related hospitalizations with shorter procedural times.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Estudios Prospectivos , Resultado del Tratamiento , Volumen de Ventilación Pulmonar , Recurrencia Local de Neoplasia/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA