RESUMEN
BACKGROUND: The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA). METHODS: Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained. RESULTS: Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR). CONCLUSION: Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases.
Asunto(s)
Aorta Torácica , Enfermedades de la Aorta , Medios de Contraste , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Humanos , Reproducibilidad de los Resultados , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Aorta Torácica/diagnóstico por imagen , Anciano , Medios de Contraste/administración & dosificación , Enfermedades de la Aorta/diagnóstico por imagen , Técnicas de Imagen Sincronizada Respiratorias , Adulto , Factores de Tiempo , Interpretación de Imagen Asistida por Computador , Técnicas de Imagen Sincronizada CardíacasRESUMEN
The microbiology, epidemiology, diagnostics, and treatment of infective endocarditis (IE) have changed significantly since the Duke Criteria were published in 1994 and modified in 2000. The International Society for Cardiovascular Infectious Diseases (ISCVID) convened a multidisciplinary Working Group to update the diagnostic criteria for IE. The resulting 2023 Duke-ISCVID IE Criteria propose significant changes, including new microbiology diagnostics (enzyme immunoassay for Bartonella species, polymerase chain reaction, amplicon/metagenomic sequencing, in situ hybridization), imaging (positron emission computed tomography with 18F-fluorodeoxyglucose, cardiac computed tomography), and inclusion of intraoperative inspection as a new Major Clinical Criterion. The list of "typical" microorganisms causing IE was expanded and includes pathogens to be considered as typical only in the presence of intracardiac prostheses. The requirements for timing and separate venipunctures for blood cultures were removed. Last, additional predisposing conditions (transcatheter valve implants, endovascular cardiac implantable electronic devices, prior IE) were clarified. These diagnostic criteria should be updated periodically by making the Duke-ISCVID Criteria available online as a "Living Document."
Asunto(s)
Enfermedades Transmisibles , Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Humanos , Endocarditis Bacteriana/microbiología , Endocarditis/etiología , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones , Enfermedades Transmisibles/complicacionesRESUMEN
IMPORTANCE: The use of 18F-FDG PET/CT in diagnostic algorithms for PVE has increased since publication of studies and guidelines advocating its use. The assessment of test accuracy has been limited by small study sizes. We undertook a systematic review using individual patient data (IPD) meta-analysis techniques. OBJECTIVE: To estimate the summary sensitivity and specificity of 18F-FDG PET/CT in diagnosing PVE. We also assessed the effect of patient factors on test accuracy as defined by changes in the odds ratios associated with each factor. The effect of the PET/CT study on the final diagnosis was also assessed when compared to the preliminary Duke classification to determine in which patient group 18F-FDG PET/CT had the greatest utility. STUDY SELECTION: Studies were included if PET/CT was performed for suspicion of PVE and IPD of both the PET/CT result and final diagnosis defined by a gold-standard assessment was available. There were 3 possible final diagnoses ("definite PVE," "possible PVE," and "rejected PVE"). RESULTS: Seventeen studies were included with IPD available for 537 patients (from 538 scans). The summary sensitivity and specificity were 85% (95% CI 74.2%-91.8%) and 86.5% (95% CI 75.8%-92.9%) respectively when patients with final diagnosis of "possible PVE" were classified as positive for PVE. When this group was classified as negative for PVE, sensitivity was 87.4% (95% CI 80.4%-92.1%) and specificity was 84.9% (95% CI 71.5%-92.6%). Patients with a known pathogen (especially coagulase negative staphylococcal species), elevated CRP, a biological or aortic valve infection appeared more likely to have an accurate PET/CT diagnosis. Those with a mechanical valve, prior antibiotic treatment or a transcatheter aortic valve replacement valve were less likely to have an accurate test. Time since valve implantation and the presence of surgical adhesive did not appear to affect test accuracy. Of the patients with a preliminary Duke classification of "possible PVE," 84% received a more conclusive final diagnosis of "definite" or "rejected" PVE after the PET/CT study. CONCLUSIONS AND RELEVANCE: 18F-FDG PET/CT has high sensitivity and specificity in diagnosing PVE and the diagnostic utility is greatest in patients with a preliminary Duke classification of "possible PVE." Some patient factors appear to affect test accuracy, though these results should be interpreted with caution given low patient numbers for subgroup analyses.
Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Fluorodesoxiglucosa F18/farmacología , Prótesis Valvulares Cardíacas/efectos adversos , Endocarditis/diagnóstico , Sensibilidad y Especificidad , Radiofármacos/farmacologíaRESUMEN
Type 2 diabetes (T2D) is responsible for high incidence of cardiovascular (CV) complications leading to heart failure. Coronary artery region-specific metabolic and structural assessment could provide deeper insight into the extent of the disease and help prevent adverse cardiac events. Therefore, in this study, we aimed at investigating such myocardial dynamics for the first time in insulin-sensitive (mIS) and insulin-resistant (mIR) T2D patients. We targeted global and region-specific variations using insulin sensitivity (IS) and coronary artery calcifications (CACs) as CV risk factor in T2D patients. IS was computed using myocardial segmentation approaches at both baseline and after an hyperglycemic-insulinemic clamp (HEC) on [18F]FDG-PET images using the standardized uptake value (SUV) (ΔSUV = SUVHEC - SUVBASELINE) and calcifications using CT Calcium Scoring. Results suggest that some communicating pathways between response to insulin and calcification are present in the myocardium, whilst differences between coronary arteries were only observed in the mIS cohort. Risk indicators were mostly observed for mIR and highly calcified subjects, which supports previously stated findings that exhibit a distinguished exposure depending on the impairment of response to insulin, while projecting added potential complications due to arterial obstruction. Moreover, a pattern relating calcification and T2D phenotypes was observed suggesting the avoidance of insulin treatment in mIS but its endorsement in mIR subjects. The right coronary artery displayed more ΔSUV, whilst plaque was more present in the circumflex. However, differences between phenotypes, and therefore CV risk, were associated to left descending artery (LAD) translating into higher CACs regarding IR, which could explain why insulin treatment was effective for LAD at the expense of higher likelihood of plaque accumulation. Personalized approaches to assess T2D may lead to more efficient treatments and risk-prevention strategies.
Asunto(s)
Calcinosis , Enfermedad de la Arteria Coronaria , Diabetes Mellitus Tipo 2 , Cardiopatías , Resistencia a la Insulina , Placa Aterosclerótica , Calcificación Vascular , Humanos , Vasos Coronarios , Diabetes Mellitus Tipo 2/metabolismo , Radiofármacos/metabolismo , Miocardio/metabolismo , Enfermedad de la Arteria Coronaria/metabolismo , Calcinosis/metabolismo , Placa Aterosclerótica/metabolismo , Cardiopatías/metabolismo , Insulina/metabolismo , Calcificación Vascular/metabolismoRESUMEN
BACKGROUND: Diabetes mellitus is an independent risk factor in the development of coronary artery disease (CAD), myocardial infarction (MI), and cardiac death (CD). The major adverse cardiac events (MACEs) between men and women in diabetic patients stratified by CAD (previous MI and/or coronary revascularization, CR) were analyzed. METHODS AND RESULTS: A cohort of 1327 consecutive diabetic patients (age 66.5 ± 9 years) underwent gated SPECT (single-photon emission computed tomography). During a mean follow-up of 4.7 ± 2.2 years post gated SPECT, MACEs (non-fatal MI, CD, and late CR) were evaluated according to gender stratified by CAD. Among diabetic patients without known CAD (N = 731), men had more MACEs (sHR 1.9;95%CI 1.2-3.2) than women. Among diabetic patients with known CAD (N = 596), there was no difference in MACEs in diabetic men and women (sHR 1.15;95%CI 0.73-1.8). Diabetic women with known CAD (n = 143) were the group with the highest risk (sHR 1.7; P = .041) for MACEs (4.5% MACEs/year, [95%CI 3.1%-6.4%]), compared to the remaining diabetic patients (N = 1184) (3% MACEs/year, [95%CI 2.6%-3.5%]). CONCLUSIONS: The prognosis of diabetic patients for MACEs is different in men and women stratified by CAD. The worst prognosis for MACEs occurs in women with known CAD.
Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Infarto del Miocardio , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Diabetes Mellitus/diagnóstico por imagen , Diabetes Mellitus/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Pronóstico , Factores de Riesgo , Factores Sexuales , Tomografía Computarizada de Emisión de Fotón ÚnicoRESUMEN
AIMS: To determine if adapting the ablation index (AI) to the left atrial wall thickness (LAWT), which is a determinant of lesion transmurality, is feasible, effective, and safe during paroxysmal atrial fibrillation (PAF) ablation. METHODS AND RESULTS: Consecutive patients referred for PAF first ablation. Left atrial wall thickness three-dimensional maps were obtained from multidetector computed tomography and integrated into the CARTO navigation system. Left atrial wall thickness was categorized into 1 mm layers and AI was titrated to the LAWT. The ablation line was personalized to avoid thicker regions. Primary endpoints were acute efficacy and safety, and freedom from atrial fibrillation (AF) recurrences. Follow-up (FU) was scheduled at 1, 3, 6, and every 6 months thereafter. Ninety patients [60 (67%) male, age 58 ± 13 years] were included. Mean LAWT was 1.25 ± 0.62 mm. Mean AI was 366 ± 26 on the right pulmonary veins with a first-pass isolation in 84 (93%) patients and 380 ± 42 on the left pulmonary veins with first-pass in 87 (97%). Procedure time was 59 min (49-66); radiofrequency (RF) time 14 min (12.5-16); and fluoroscopy time 0.7 min (0.5-1.4). No major complication occurred. Eighty-four out of 90 (93.3%) patients were free of recurrence after a mean FU of 16 ± 4 months. CONCLUSION: Personalized AF ablation, adapting the AI to LAWT allowed pulmonary vein isolation with low RF delivery, fluoroscopy, and procedure time while obtaining a high rate of first-pass isolation, in this patient population. Freedom from AF recurrences was as high as in more demanding ablation protocols. A multicentre trial is ongoing to evaluate reproducibility of these results.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Reproducibilidad de los Resultados , Resultado del TratamientoRESUMEN
Infective endocarditis (IE) is a complex disease with cardiac involvement and multiorgan complications. Its prognosis depends on prompt diagnosis that leads to an aggressive therapeutic management combining antibiotic therapy and early cardiac surgery when indicated. However, IE diagnosis always poses a challenge, and echocardiography remains diagnostically imperfect in cases of prosthetic valve IE or cardiac implantable electronic device infection. In recent years, other imaging modalities (computed tomography, magnetic resonance imaging, nuclear imaging) have experienced significant technical improvements, and their application to the detection of cardiac and extracardiac IE-related lesions seems to be a strategic way forward in the management of patients with suspected IE. However, the scientific evidence in the literature remains limited; current guidelines address the use of the multimodality imaging in the field of IE with caution; the incremental value of each technique and their combinations is debated; and their use varies across countries. Despite these limitations, healthcare providers and surgeons should be aware of the possibilities offered by the multimodal imaging approach when appropriate. Here, we emphasize the value of a multidisciplinary heart valve team, the endocarditis team, underlining the importance of cardiac and extracardiac imaging experts in playing a key role in informing the diagnosis and management of patients with IE. Illustrative cases, critical appraisal of contemporary data, and conceptual and practical suggestions for clinicians that may help to improve the prognosis of patients with IE are provided in this review article.
Asunto(s)
Endocarditis/diagnóstico por imagen , Imagen Multimodal , Grupo de Atención al Paciente , Conducta Cooperativa , Endocarditis/terapia , Humanos , Comunicación Interdisciplinaria , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los ResultadosRESUMEN
OBJECTIVE: To implement detailed EU cardiac computed tomography angiography (CCTA) quality criteria in the multicentre DISCHARGE trial (FP72007-2013, EC-GA 603266), we reviewed image quality and adherence to CCTA protocol and to the recommendations of invasive coronary angiography (ICA) in a pilot study. MATERIALS AND METHODS: From every clinical centre, imaging datasets of three patients per arm were assessed for adherence to the inclusion/exclusion criteria of the pilot study, predefined standards for the CCTA protocol and ICA recommendations, image quality and non-diagnostic (NDX) rate. These parameters were compared via multinomial regression and ANOVA. If a site did not reach the minimum quality level, additional datasets had to be sent before entering into the final accepted database (FADB). RESULTS: We analysed 226 cases (150 CCTA/76 ICA). The inclusion/exclusion criteria were not met by 6 of the 226 (2.7%) datasets. The predefined standard was not met by 13 of 76 ICA datasets (17.1%). This percentage decreased between the initial CCTA database and the FADB (multinomial regression, 53 of 70 vs 17 of 75 [76%] vs [23%]). The signal-to-noise ratio and contrast-to-noise ratio of the FADB did not improve significantly (ANOVA, p = 0.20; p = 0.09). The CTA NDX rate was reduced, but not significantly (initial CCTA database 15 of 70 [21.4%]) and FADB 9 of 75 [12%]; p = 0.13). CONCLUSION: We were able to increase conformity to the inclusion/exclusion criteria and CCTA protocol, improve image quality and decrease the CCTA NDX rate by implementing EU CCTA quality criteria and ICA recommendations. KEY POINTS: ⢠Failure to meet protocol adherence in cardiac CTA was high in the pilot study (77.6%). ⢠Image quality varies between sites and can be improved by feedback given by the core lab. ⢠Conformance with new EU cardiac CT quality criteria might render cardiac CTA findings more consistent and comparable.
Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Reproducibilidad de los ResultadosRESUMEN
The original version of this article, published on 16 December 2019, unfortunately contained two mistakes.
RESUMEN
BACKGROUND: The diagnosis of infective endocarditis (IE) in prosthetic valves and intracardiac devices is challenging because both the modified Duke criteria (DC) and echocardiography have limitations in this population. The added value of (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET)/computed tomography (CT) and (18)F-FDG PET/CT angiography (PET/CTA) was evaluated in this complex scenario at a referral center with a multidisciplinary IE unit. METHODS AND RESULTS: Ninety-two patients admitted to our hospital with suspected prosthetic valve or cardiac device IE between November 2012 and November 2014 were prospectively included. All patients underwent echocardiography and PET/CT, and 76 had cardiac CTA. PET/CT and echocardiography findings were evaluated and compared, with concordant results in 54% of cases (κ=0.23). Initial diagnoses with DC at admission, PET/CT, and DC+PET/CT were compared with the final diagnostic consensus reached by the IE Unit. DC+PET/CT enabled reclassification of 90% of cases initially classified as possible IE with DC and provided a conclusive diagnosis (definite/rejected) in 95% of cases. Sensitivity, specificity, and positive and negative predictive values were 52%, 94.7%, 92.9%, and 59.7% for DC; 87%, 92.1%, 93.6%, and 84.3% for PET/CT; and 90.7%, 89.5%, 92%, and 87.9% for DC+PET/CT. Use of PET/CTA yielded even better diagnostic performance values than PET/nonenhanced CT (91%, 90.6%, 92.8%, and 88.3% versus 86.4%, 87.5%, 90.2%, and 82.9%) and substantially reduced the rate of doubtful cases from 20% to 8% (P<0.001). DC+PET/CTA reclassified an additional 20% of cases classified as possible IE with DC+PET/nonenhanced CT. In addition, PET/CTA enabled detection of a significantly larger number of anatomic lesions associated with active endocarditis than PET/nonenhanced CT (P=0.006) or echocardiography (P<0.001). CONCLUSIONS: (18)F-FDG PET/CT improves the diagnostic accuracy of the modified DC in patients with suspected IE and prosthetic valves or cardiac devices. PET/CTA yielded the highest diagnostic performance and provided additional diagnostic benefits.
Asunto(s)
Angiografía/métodos , Desfibriladores Implantables/microbiología , Endocarditis/diagnóstico , Prótesis Valvulares Cardíacas/microbiología , Marcapaso Artificial/microbiología , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Arritmias Cardíacas/terapia , Ecocardiografía , Endocarditis/diagnóstico por imagen , Femenino , Fluorodesoxiglucosa F18 , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Valor Predictivo de las Pruebas , Estudios Prospectivos , Estudios Retrospectivos , Sensibilidad y EspecificidadAsunto(s)
Endocarditis/diagnóstico por imagen , Fluorodesoxiglucosa F18/uso terapéutico , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Endocarditis/cirugía , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas , Tomografía Computarizada por Tomografía de Emisión de Positrones/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/normas , Reemplazo de la Válvula Aórtica Transcatéter/tendenciasRESUMEN
AIMS: To date, no studies have investigated the association between lipid species and coronary plaque changes over time, quantitatively assessed by serial imaging. We aimed to prospectively determine the association between lipid species quantified by a plasma lipidomic analysis and coronary plaque changes according to composition assessed by a quantitative serial analysis of coronary computed tomography angiography (CTA). METHODS AND RESULTS: Patients with suspected coronary artery disease (CAD) undergoing baseline coronary CTA were prospectively enrolled by seven EU centres in the SMARTool study and submitted to clinical, molecular, and coronary CTA re-evaluation at follow-up (an inter-scan period of 6.39 ± 1.17 years). Out of 202 patients who were analysed in the SMARTool main clinical study, a lipidomic analysis was performed in 154 patients before the baseline coronary CTA, and this group was included in the present study. A quantitative CTA analysis was performed by using a separate core laboratory blinded from clinical data. In the univariable analysis, it was found that no lipid species were significantly associated with annual total and calcified plaque changes. After adjusting for clinical variables at baseline and statin use, it was found that three lipid species were significantly associated with non-calcified plaque progression. In detail, cholesteryl ester(20:3), sphingomyelin (SM)(40:3), and SM(41:1) were found to be positively related to non-calcified plaque progression (Bonferroni-adjusted P-values = 0.005, 0.016, and 0.004, respectively). CONCLUSION: The current study showed an independent relationship between specific lipid species determined by a plasma lipidomic analysis and non-calcified coronary plaque progression assessed by a serial, quantitative coronary CTA analysis.
Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Lipidómica , Placa Aterosclerótica , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angiografía por Tomografía Computarizada/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/sangre , Progresión de la Enfermedad , Lípidos/sangre , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/sangre , Estudios Prospectivos , Índice de Severidad de la EnfermedadRESUMEN
OBJECTIVES: To assess the impact of 18F-FDG-PET/CT on the diagnosis and management of patients with Staphylococcus aureus bacteraemia (SAB). METHODS: Post hoc analysis of a prospective cohort of consecutive adult patients diagnosed with SAB (January 2013-December 2017). Patients who underwent 18F-FDG-PET/CT at the discretion of the attending physician were included. Endpoints were the identification of previously unknown infectious foci and changes in clinical management, defined as changes in the duration or class of antibiotic therapy, a surgical procedure on the source of infection or a change in the decision to remove or retain an implantable device. RESULTS: We included 39 patients (median age: 69 years, IQR:60-79). Fifteen (39%) patients did not have an infectious focus identified before 18F-FDG-PET/CT). Thirty new infectious foci were detected in 22/39 (56%) patients. In 11/15 (73%) patients without an identified focus at least one infectious focus was detected by 18F-FDG-PET/CT. In 22/26 (85%) patients with implantable devices, 18F-FDG-PET/CT confirmed or ruled out infection or detected local complications. Out of 13 device infections, 10 were detected by 18F-FDG-PET/CT (7/10 for the first time). In 19/39 (49%) patients 18F-FDG-PET/CT results led to changes in clinical management (15 changes in antibiotic therapy, 2 device removals, 2 surgical procedures, 1 avoidance of a surgical procedure). CONCLUSIONS: 18F-FDG-PET/CT may be a useful asset in the management of selected SAB cases, allowing the identification of previously undetected infectious foci and optimization of therapy, particularly in patients with endovascular devices. Indication should be made on a case-by-case basis.