Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Eur J Clin Microbiol Infect Dis ; 37(7): 1333-1344, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29700761

RESUMEN

Molecular tests may enable early adjustment of antimicrobial therapy and be complementary to blood culture (BC) which has imperfect sensitivity in critically ill patients. We evaluated a novel multiplex real-time PCR assay to diagnose bloodstream pathogens directly in whole blood samples (BSI-PCR). BSI-PCR included 11 species- and four genus-specific PCRs, a molecular Gram-stain PCR, and two antibiotic resistance markers. We collected 5 mL blood from critically ill patients simultaneously with clinically indicated BC. Microbial DNA was isolated using the Polaris method followed by automated DNA extraction. Sensitivity and specificity were calculated using BC as reference. BSI-PCR was evaluated in 347 BC-positive samples (representing up to 50 instances of each pathogen covered by the test) and 200 BC-negative samples. Bacterial species-specific PCR sensitivities ranged from 65 to 100%. Sensitivity was 26% for the Gram-positive PCR, 32% for the Gram-negative PCR, and ranged 0 to 7% for yeast PCRs. Yeast detection was improved to 40% in a smaller set-up. There was no overall association between BSI-PCR sensitivity and time-to-positivity of BC (which was highly variable), yet Ct-values were lower for true-positive versus false-positive PCR results. False-positive results were observed in 84 (4%) of the 2200 species-specific PCRs in 200 culture-negative samples, and ranged from 0 to 6% for generic PCRs. Sensitivity of BSI-PCR was promising for individual bacterial pathogens, but still insufficient for yeasts and generic PCRs. Further development of BSI-PCR will focus on improving sensitivity by increasing input volumes and on subsequent implementation as a bedside test.


Asunto(s)
Candida/aislamiento & purificación , ADN Bacteriano/genética , Bacterias Gramnegativas/aislamiento & purificación , Bacterias Grampositivas/aislamiento & purificación , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Sepsis/diagnóstico , Candida/clasificación , Candida/genética , Enfermedad Crítica , Bacterias Gramnegativas/clasificación , Bacterias Gramnegativas/genética , Bacterias Grampositivas/clasificación , Bacterias Grampositivas/genética , Humanos , Sensibilidad y Especificidad , Sepsis/microbiología
2.
Crit Care ; 22(1): 105, 2018 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-29679983

RESUMEN

BACKGROUND: Rapid and accurate diagnosis of neonatal sepsis is highly warranted because of high associated morbidity and mortality. The aim of this study was to evaluate the performance of a novel multiplex PCR assay for diagnosis of late-onset sepsis and to investigate the value of bacterial DNA load (BDL) determination as a measure of infection severity. METHODS: This cross-sectional study was conducted in a neonatal intensive care unit. Preterm and/or very low birth weight infants suspected for late-onset sepsis were included. Upon suspicion of sepsis, a whole blood sample was drawn for multiplex PCR to detect the eight most common bacteria causing neonatal sepsis, as well as for blood culture. BDL was determined in episodes with a positive multiplex PCR. RESULTS: In total, 91 episodes of suspected sepsis were investigated, and PCR was positive in 53 (58%) and blood culture in 60 (66%) episodes, yielding no significant difference in detection rate (p = 0.17). Multiplex PCR showed a sensitivity of 77%, specificity of 81%, positive predictive value of 87%, and negative predictive value of 68% compared with blood culture. Episodes with discordant results of PCR and blood culture included mainly detection of coagulase-negative staphylococci (CoNS). C-reactive protein (CRP) level and immature to total neutrophil (I/T) ratio were lower in these episodes, indicating less severe disease or even contamination. Median BDL was high (4.1 log10 cfu Eq/ml) with a wide range, and was it higher in episodes with a positive blood culture than in those with a negative blood culture (4.5 versus 2.5 log10 cfu Eq/ml; p < 0.0001). For CoNS infection episodes BDL and CRP were positively associated (p = 0.004), and for Staphylococcus aureus infection episodes there was a positive association between BDL and I/T ratio (p = 0.049). CONCLUSIONS: Multiplex PCR provides a powerful assay to enhance rapid identification of the causative pathogen in late-onset sepsis. BDL measurement may be a useful indicator of severity of infection.


Asunto(s)
ADN Bacteriano/análisis , Sepsis/diagnóstico , Carga Bacteriana/inmunología , Carga Bacteriana/métodos , Cultivo de Sangre/métodos , Estudios Transversales , ADN Bacteriano/genética , Femenino , Edad Gestacional , Humanos , Recién Nacido , Recien Nacido Prematuro/sangre , Recien Nacido Prematuro/fisiología , Unidades de Cuidado Intensivo Neonatal/organización & administración , Tiempo de Internación/estadística & datos numéricos , Masculino , Países Bajos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos
3.
J Microbiol Methods ; 106: 8-15, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25102109

RESUMEN

The diagnosis of late onset sepsis (LOS), a severe condition with high prevalence in preterm infants, is hampered by the suboptimal sensitivity and long turnaround time of blood culture. Detection of the infecting pathogen directly in blood by PCR would provide a much more timely result. Unfortunately, PCR-based assays reported so far are labor intensive and often lack direct species identification. Therefore we developed a real-time multiplex PCR assay tailored to LOS diagnosis which is easy-to-use, is applicable on small blood volumes and provides species-specific results within 4h. Species-specific PCR assays were selected from literature or developed using bioinformatic tools for the detection of the most prevalent etiologic pathogens: Enterococcus faecalis, Staphylococcus aureus, Staphylococcus spp., Streptococcus agalactiae, Escherichia coli, Pseudomonas aeruginosa, Klebsiella spp. and Serratia marcescens. The PCR assays showed 100% specificity, full coverage of the target pathogens and a limit of detection (LOD) of ≤10CFUeq./reaction. These LOD values were maintained in the multiplex format or when bacterial DNA was isolated from blood. Clinical evaluation showed high concordance between the multiplex PCR and blood culture. In conclusion, we developed a multiplex PCR that allows the direct detection of the most important bacterial pathogens causing LOS in preterm infants.


Asunto(s)
Bacterias/aislamiento & purificación , Sangre/microbiología , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Sepsis/diagnóstico , Sepsis/microbiología , Bacterias/clasificación , Bacterias/genética , Humanos , Recién Nacido , Sensibilidad y Especificidad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA