RESUMEN
INTRODUCTION: Electrical cardioversion (ECV) is a frequently used procedure for restoring sinus rhythm in atrial fibrillation (AF); however, the rate of recurrence is high. The identification of patients at high risk of recurrence could influence the decision-making process. The present study evaluates the predictive value of risk scores in atrial fibrillation recurrence after elective electrical cardioversion. METHODS: Unicentric, observational, and prospective study of adult patients who have undergone an elective ECV as rhythm control strategy between July 2017 and September 2022. RESULTS: From the 283 analyzed patients (mean age 63.95 ± 10.76212, 74.9% male); 99 had paroxysmal AF (35%) and 159 (59%) presented AF recurrence during a follow-up of 6 months. In patients with post-ECV AF recurrence, the period of time from diagnosis until the performance of the procedure was longer (393 ± 891 vs. 195 ± 527, p = .02). No paroxysmal AF (71.3% vs. 57.8%, p = .02) and LA dilatation with >40 mL/m2 (35.9% vs. 23.3%, p = .02) volumes were more frequent within these patients. AF recurrence was more frequent in patients who had previous ECV (HR = 1.32; 95% CI: 1.12-2.35; p = .01) and more than 1 shock to recover sinus rhythm (HR = 1.62; 95% CI: 1.07-1.63; p = .01). The SLAC, ALARMEc, ATLAS, and CAAP-AF scores were statistically significant, although with a moderate predictive capacity for post-ECV recurrence. CONCLUSIONS: Risk scores analyzed showed a modest value predicting AF recurrence after ECV. Previous ECV, and greater difficulty in restoring SR were independent predictors of recurrence.
Asunto(s)
Fibrilación Atrial , Adulto , Humanos , Masculino , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Estudios Prospectivos , Cardioversión Eléctrica/métodos , Electrocardiografía , Factores de Riesgo , Recurrencia , Resultado del TratamientoRESUMEN
BACKGROUND: European Guidelines on Myocardial Revascularization recommend clopidogrel loading dose added to acetylsalicylic acid in elective percutaneous coronary interventions (PCIs). However, there is few evidence supporting this recommendation and other P2Y12 inhibitors have not been tested in these patients. PURPOSE: To evaluate the effectiveness and safety of different loading doses of clopidogrel and ticagrelor in patients without double antiplatelet therapy and stable coronary artery disease (SCAD) undergoing elective PCI. METHODS: Retrospective study of 147 consecutive patients with SCAD undergoing elective PCI. Loading P2Y12 inhibitor doses evaluated were: clopidogrel 600 mg, clopidogrel 300 mg, clopidogrel 150 mg, and ticagrelor 180 mg. We analyzed the occurrence of major adverse cardiovascular events and periprocedural myocardial infarction. RESULTS: One hundred twenty-five patients were treated with clopidogrel (16 with clopidogrel 150 mg, 7 with clopidogrel 300 mg, and 93 with clopidogrel 600 mg) and 21 with ticagrelor 180 mg at the catheterization laboratory. The ticagrelor group had a significantly lower postprocedural peak of troponin-I (0.7 ± 3.4 vs. 0.3 ± 0.7 ng/mL; P = 0.02). There were no differences between groups in terms of major bleeding and hemoglobin drop after PCI (0.6 ± 0.8 vs. 4 ± 0.6; P = 0.8). The median of follow-up was 17 months (interquartile range 9-32.7). At the end of follow-up, major adverse cardiovascular event rate was not different between groups. CONCLUSIONS: In patients without dual antiplatelet therapy undergoing elective PCI, the use of ticagrelor showed lower postprocedural myocardial injury without more bleeding complications.
Asunto(s)
Clopidogrel/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/administración & dosificación , Antagonistas del Receptor Purinérgico P2Y/administración & dosificación , Ticagrelor/administración & dosificación , Anciano , Anciano de 80 o más Años , Clopidogrel/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Hemorragia/inducido químicamente , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Antagonistas del Receptor Purinérgico P2Y/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Ticagrelor/efectos adversos , Factores de Tiempo , Resultado del TratamientoRESUMEN
INTRODUCTION AND OBJECTIVES: Red flags (RF) are typical cardiac and extracardiac manifestations that may precede the definitive diagnosis of cardiac amiloidosis (CA) by several years, playing a pivotal role in the early diagnosis of the disease. The principal aim of the research was to determine the chronology of onset of RF throughout the natural history of CA as well as its prognostic influence. PATIENTS AND METHODS: Observational, retrospective inquiry of consecutive patients with a definitive diagnosis of CA in a terciary hospital centre in Ciudad Real (Spain) between February 2016 and December 2023. We defined 21 RF and 3 adverse clinical events, establishing the date of occurrence of each of them. RESULTS: 102 patients (81.6±7.7 years; 84,3% males) with a diagnosis of CA (89.2% TTR; 10,8% AL) were included. The prevalence of RF was very high (8.4±2.3). In the natural history, the first to appear were integumentary, with the most specific cardiological ones being the closest to diagnosis. The 2-year mortality was 49%, with biomarker RFs and the presence of ≥10 RFs being associated with higher mortality. CONCLUSIONS: RFs proved highly prevalent among patients with CA and substantially preceded disease diagnosis. RF burden was associated with prognosis in the follow-up of ATTR patients.
RESUMEN
INTRODUCTION AND OBJECTIVES: This article presents the 2023 activity report of the Interventional Cardiology Association of the Spanish Society of Cardiology (ACI-SEC). METHODS: All interventional cardiology laboratories in Spain were invited to participate in an online survey. Data analysis was carried out by an external company and subsequently reviewed and presented by the members of the ACI-SEC board. RESULTS: A total of 119 hospitals participated. The number of diagnostic studies decreased by 1.8%, while the number of percutaneous coronary interventions (PCI) showed a slight increase. There was a reduction in the number of stents used and an increase in the use of drug-coated balloons. The use of intracoronary diagnostic techniques remained stable. For the first time, data on PCI guided by intracoronary imaging was reported, showing a 10% usage rate in Spain. Techniques for plaque modification continued to grow. Primary PCI increased, becoming the predominant treatment for myocardial infarction (97%). Noncoronary structural procedures continued their upward trend. Notably, the number of left atrial appendage closures, patent foramen ovale closures, and tricuspid valve interventions grew in 2023. There was also a significant increase in interventions for acute pulmonary embolism. CONCLUSIONS: The 2023 Spanish cardiac catheterization and coronary intervention registry indicates a stabilization in coronary interventions, together with an increase in complexity. There was consistent growth in procedures for both valvular and nonvalvular structural heart diseases.
Asunto(s)
Cateterismo Cardíaco , Cardiología , Intervención Coronaria Percutánea , Sistema de Registros , Sociedades Médicas , España , Humanos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/estadística & datos numéricos , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/estadística & datos numéricosAsunto(s)
Trombectomía , Trombosis , Humanos , Infarto del Miocardio con Elevación del ST , Conducta SocialRESUMEN
INTRODUCTION AND OBJECTIVES: This article presents the annual activity report of the Interventional Cardiology Association of the Spanish Society of Cardiology (ACI-SEC) for the year 2022. METHODS: All Spanish centers with catheterization laboratories were invited to participate. Data were collected online and were analyzed by an external company in collaboration with the members of the board of the ACI-SEC. RESULTS: A total of 111 centers participated. The number of diagnostic studies increased by 4.8% compared with 2021, while that of percutaneous coronary interventions (PCI) remained stable. PCIs on the left main coronary artery increased by 22%. The radial approach continued to be preferred for PCI (94.9%). There was an upsurge in the use of drug-eluting balloons, as well as in intracoronary imaging techniques, which were used in 14.7% of PCIs. The use of pressure wires also increased (6.3% vs 2021) as did plaque modification techniques. Primary PCI continued to grow and was the most frequent treatment (97%) in ST-segment elevation myocardial infarction. Most noncoronary procedures maintained their upward trend, particularly percutaneous aortic valve implantation, atrial appendage closure, mitral/tricuspid edge-to-edge therapy, renal denervation, and percutaneous treatment of pulmonary arterial disease. CONCLUSIONS: The Spanish cardiac catheterization and coronary intervention registry for 2022 reveals a rise in the complexity of coronary disease, along with a notable growth in procedures for valvular and nonvalvular structural heart disease.
Asunto(s)
Cardiología , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Cateterismo Cardíaco , Sistema de RegistrosRESUMEN
BACKGROUND: Both stent length and stent overlap are associated with worse outcomes in the percutaneous treatment of diffuse coronary artery disease (dCAD). However, evidence comparing these issues is scarce. We aimed to compare the results between the use of single very long stent (VLS) and ≥2 overlapping stents (OS) in the treatment of dCAD. METHODS: Seven hundred twenty-four consecutive lesions were included: 275 treated with a single VLS (≥40 mm) and 449 with ≥2 OS. Procedural characteristics were assessed, and survival analysis was performed to compare the incidence of major adverse cardiovascular events (MACE; composite of cardiovascular death, nonfatal myocardial infarction, target lesion revascularization [TLR], or stent thrombosis) during a median follow-up of 31 months. RESULTS: Procedures with VLS required less contrast volume (268 ± 122 vs 302 ± 113 cm3; P < .01), fluoroscopy time (16 ± 8 vs 21 ± 16 minutes; P < .01), and procedure duration (37 ± 18 vs 47 ± 27 minutes; P < .01) than the OS procedures. The VLS group showed lower incidence of MACE (4.4% vs 10.7%; P < .01), driven mainly by lower TLR rate (1.1% vs 4.7%; P < .01). The use of OS was an independent predictor of MACE. CONCLUSIONS: In this study, the use of VLS for the treatment of dCAD was associated with better outcomes compared to OS.
Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Infarto del Miocardio sin Elevación del ST/terapia , Intervención Coronaria Percutánea/instrumentación , Infarto del Miocardio con Elevación del ST/terapia , Stents , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio sin Elevación del ST/diagnóstico por imagen , Infarto del Miocardio sin Elevación del ST/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/mortalidad , Factores de Tiempo , Resultado del TratamientoRESUMEN
Drug-eluting balloons currently constitute a therapeutic tool used in percutaneous coronary interventions (PCI). Long-term results remain unknown. We evaluated the prognosis of PCI using a second generation paclitaxel-eluting balloon (PEB) in real-world patients. We included all PCI with PEB in de novo or in-stent restenosis coronary lesions performed in our unit from March 2009 to March 2019. We assessed the composite of major adverse cardiovascular events (MACE) rate after a median follow-up of 42 months. Consecutive patients (n = 320) with 386 lesions were included; 46.9% presented with stable angina and 53.1% acute coronary syndromes; 52.6% of the lesions were in-stent restenosis and 47.3% de novo lesions with a mean diameter of 2.4 ± 0.5 mm. A bare metal stent was implanted in 6.7% and a drug-eluting stent in 8.5% of patients. The MACE rate was 8%: 10 (2.6%) cardiovascular deaths, 13 (3.4%) myocardial infarctions, and 16 (4.1%) target lesion revascularization. The all-cause death rate was 5.2%. No cases of thrombosis were recorded. In conclusion, PEB was a safe and effective tool to treat in-stent restenosis and de novo coronary lesions, especially small vessel disease, during long-term follow-up.
Asunto(s)
Síndrome Coronario Agudo/terapia , Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/uso terapéutico , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/terapia , Paclitaxel/uso terapéutico , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/mortalidad , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Estudios Prospectivos , Factores de Tiempo , Resultado del TratamientoRESUMEN
The recognition of woven coronary artery anomaly is difficult because of its rare nature. Optical coherence tomography imaging is challenging due to the tortuosity of the channels; however, it is crucial not only for the differential diagnosis but also to guide the treatment approach.
Asunto(s)
Enfermedad de la Arteria Coronaria , Anomalías de los Vasos Coronarios , Angiografía Coronaria , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Diagnóstico Diferencial , Femenino , Humanos , Persona de Mediana Edad , Tomografía de Coherencia ÓpticaRESUMEN
BACKGROUND: The clinical impact of percutaneous coronary intervention (PCI) and implantation of overlapping stents (OS) using platforms with the same versus different pharmacological characteristics is unknown. Our objective was to compare the outcomes of PCI with OS according to their pharmacological characteristics. METHODS: In this observational single-center registry, we included all PCI performed from April 2014 to December 2018 in which overlapping drug-eluting stents were implanted. Two groups were created according to whether the stents release the same drug [homogeneous: (HO)] or different [heterogeneous: (HE)]. The primary endpoint was the need for target lesion revascularization (TLR). Clinical assessment was performed after the procedure, bianually and at the end of follow-up (June 2019). RESULTS: 381 lesions with OS (HO: 209; HE: 172) were included (75.1% male, 66.7⯱â¯11.6â¯years). Clinical presentation was stable coronary artery disease in 49.9%. Syntax score was 23.7⯱â¯13.3. The number of OS implanted was 2.2⯱â¯0.5 and the total stent length was 59.5⯱â¯20.1â¯mm (HE: 61.5⯱â¯21.6 vs. HO: 57.8⯱â¯18.8â¯mm; pâ¯<â¯0.01). After a median follow-up of 21â¯months, the HE group showed a lower TLR rate than the HO group (HE:2.3% vs HO:7.2%; pâ¯=â¯0.03). The rates of cardiac death (pâ¯=â¯0.44), myocardial infarction (pâ¯=â¯0.36) and stent thrombosis (pâ¯=â¯0.85) were similar between groups. In the multivariate analysis, the OS with homogeneous-drug devices was an independent predictor of a higher rate of TLR. CONCLUSIONS: PCI using OS with homogeneous pharmacological characteristics was associated with a higher rate of TLR in comparison with the implantation of OS with heterogeneous pharmacological characteristics.
Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Anciano , Stents Liberadores de Fármacos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Pronóstico , Factores de Riesgo , Resultado del TratamientoRESUMEN
OBJECTIVES: This study sought to assess the efficacy of the drug-coated balloon (DCB) ESSENTIAL for the treatment of in-stent restenosis (ISR). BACKGROUND: DCBs have proven a valid therapeutic option for the management of ISR in several clinical trials, yet no class effect can be claimed. Accordingly, every new DCB model has to be individually evaluated through clinical studies. METHODS: This is a prospective, multicenter study including consecutive patients undergoing percutaneous coronary intervention for ISR with the ESSENTIAL DCB. A 6-month quantitative coronary angiography (QCA)/optical coherence tomography (OCT) follow-up was scheduled. The primary endpoint was OCT-derived in-segment maximal area stenosis. Secondary endpoints included QCA-derived in-segment late lumen loss (LLL) and target lesion failure (TLF) rates at 6, 12, and 24â¯months. TLF was defined as the composite of cardiac death, target vessel myocardial infarction, and target lesion revascularization. RESULTS: A total of 31 patients were successfully treated with DCB, with 67% of ISR corresponding to drug-eluting stents (DES). At 6â¯months, 26 patients underwent the scheduled angiographic follow-up. The mean value for in-segment maximal area stenosis was 51.4⯱â¯13% and the median value was 53% (IQR 46.4-59.5). In the DES-ISR subgroup, these parameters were 52.6⯱â¯10% and 55.2% (IQR 49.3-58.5), respectively. In-segment LLL was 0.25⯱â¯0.43â¯mm with only 2 (7.7%) patients showing binary restenosis (>50%). The incidence of TLF was 10% at 6â¯months, 13.3% at 12â¯months, and 13.3% at 24â¯months. CONCLUSIONS: In this study, the ESSENTIAL DCB showed sustained efficacy in the prevention of recurrent restenosis after treatment of ISR. SUMMARY: We sought to assess the efficacy of the drug-coated balloon ESSENTIAL for the treatment of in-stent restenosis through a prospective, multicenter study including QCA and OCT assessment at 6-month follow-up. The primary endpoint was in-segment maximal area stenosis. Among the 31 patients successfully treated with the ESSENTIAL DCB, an angiographic follow-up was conducted in 26. Mean in-segment maximal area stenosis was 51.4⯱â¯13% and the median value was 53% (IQR 46.4-59.5). In the DES-ISR subgroup, corresponding values were 52.6⯱â¯10% and 55.2% (IQR 49.3-58.5), respectively. The observed in-segment LLL was 0.25⯱â¯0.43â¯mm and binary restenosis rate was 7.7%. TLF was 10% at 6â¯months and 13.3% at 12 and 24â¯months.
Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Paclitaxel/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Stents , Tomografía de Coherencia Óptica , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/mortalidad , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Riesgo , España , Resultado del TratamientoRESUMEN
This image series shows how bypass grafts may tent the vessel to which they are anastomosed, potentially changing the expected course of the native coronary vessel. This fact must be taken into account during CTO-PCI, and this case emphasizes the importance of careful analysis of coronary anatomy with several angiographic projections.
Asunto(s)
Angioplastia Coronaria con Balón/métodos , Puente de Arteria Coronaria/efectos adversos , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/cirugía , Oclusión de Injerto Vascular/terapia , Vena Safena/trasplante , Anciano , Angina de Pecho/diagnóstico , Angina de Pecho/etiología , Cateterismo Cardíaco/métodos , Angiografía Coronaria/métodos , Puente de Arteria Coronaria/métodos , Stents Liberadores de Fármacos , Estudios de Seguimiento , Oclusión de Injerto Vascular/diagnóstico por imagen , Humanos , Masculino , Medición de Riesgo , Índice de Severidad de la Enfermedad , Resultado del TratamientoRESUMEN
The treatment of coronary lesions caused by blunt chest trauma is controversial. To our knowledge, this is the first report of a coronary dissection related to blunt chest trauma evaluated with OCT and treated with a magnesium resorbable scaffold.
Asunto(s)
Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Aneurisma Coronario/cirugía , Traumatismos Torácicos/complicaciones , Andamios del Tejido , Tomografía de Coherencia Óptica/métodos , Heridas no Penetrantes/complicaciones , Implantes Absorbibles , Enfermedad Aguda , Disección Aórtica/diagnóstico , Disección Aórtica/etiología , Aneurisma Coronario/diagnóstico , Aneurisma Coronario/etiología , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Humanos , Magnesio , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Traumatismos Torácicos/diagnóstico , Heridas no Penetrantes/diagnósticoRESUMEN
BACKGROUND: The stent length as well as the stent overlap for the percutaneous treatment of diffuse coronary disease have been considered predictors of adverse events. However, there are no comparative data on the use of very long stents or overlapping stents in this scenario. OBJECTIVE: To compare the clinical results of very long stents (≥40â¯mm) or overlapping stents in real clinical practice. METHODS: We included 643 lesions in 628 consecutive patients treated with a single very long stent (≥40â¯mm) (251 lesions) or ≥2 overlapped stents (392 lesions). We analyzed the procedural characteristics and the presentation of the combined endpoint [cardiovascular death, non-fatal myocardial infarction, need for target lesion revascularization or stent thrombosis] after a follow-up of 20â¯months. RESULTS: Total stent length was 54⯱â¯18â¯mm and minimum diameter was 2.9⯱â¯1.2â¯mm. At the end of follow-up, the rate of adverse events was 8.3% (cardiac death: 4.9%, myocardial infarction: 1.7%, target lesion revascularization: 3.1%, stent thrombosis: 0.7%). There were no significant differences between both groups in the presentation of the combined endpoint. Procedures with overlapping stents had more contrast volume (309⯱â¯115 vs 273⯱â¯127â¯ml; pâ¯=â¯0.002), longer duration (47⯱â¯22 vs 39⯱â¯18â¯min; pâ¯<â¯0.0001), higher fluoroscopy time (20⯱â¯13 vs 16⯱â¯9â¯min; pâ¯<â¯0.0001) and higher number of stents to treat the index lesion (2.2⯱â¯0.5 vs 1; pâ¯<â¯0.0001). CONCLUSIONS: New designs of very long stents allow not only treating increasingly complex lesions, but also simplifying the procedure and decreasing the number of stents with very favorable results similar to those obtained with stent overlap.
Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/instrumentación , Diseño de Prótesis , Stents , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Sistema de Registros , Retratamiento , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoAsunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Valvuloplastia con Balón/métodos , Diseño de PrótesisRESUMEN
AIMS: To analyse systematic isolated post-dilatation of the side branch as a part of provisional stent technique. METHODS: 1960 angioplasties performed in two centres were prospectively registered, of which 382 were coronary bifurcations with a side branch>2mm. In centre A, isolated post-dilatation of the side branch was performed regardless its impairment after main vessel stenting. In centre B, side branch post-dilatation was performed only if it was severely affected after stent implantation. RESULTS: There was no difference between the two centres in the rate of side branch affection after stent implantation (A: 44.6 vs B: 49.3%, p=0.48) nor in the procedural success rate (A: 98.6% vs B: 96.7%, p=0.45). After one-year follow-up, a reduction of cardiovascular events was observed in centre A (A: 4.4% vs B: 10.4%, p=0.043) with a trend towards lower cardiac mortality (A: 2.2% vs B: 6.5%, p=0.093) and stent thrombosis (A: 0% vs B: 2.6%, p=0.077). There were no differences in the rate of myocardial infarction related to the treated artery (A: 1.4% vs B: 3.9%, p=0.29), or target lesion revascularization (A: 1.4% vs. B: 3.2%, p=0.45). CONCLUSIONS: Systematic isolated post-dilatation of the side branch in the provisional stent technique was associated with a high angiographic success rate, and a low rate of cardiovascular events during follow-up. Although the study design does not allow definitive conclusions, this strategy could be considered a valid option in some cases or even as part of the provisional stent technique.
Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/cirugía , Stents , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Radiografía Intervencional , Sistema de Registros , Factores de Riesgo , España , Factores de Tiempo , Resultado del TratamientoRESUMEN
A 53-year-old man underwent percutaneous coronary intervention of a chronic total occlusion of the circumflex artery. A mini-crush stent technique with two drug-eluting stents was performed. To the best of our knowledge, this is the first case of coronary artery aneurysm affecting a bifurcated chronic total occlusion treated with a two-stent technique.
Asunto(s)
Aneurisma Coronario/etiología , Oclusión Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Enfermedad Crónica , Aneurisma Coronario/diagnóstico , Angiografía Coronaria , Oclusión Coronaria/diagnóstico , Vasos Coronarios/cirugía , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Tomografía de Coherencia ÓpticaRESUMEN
A single coronary artery is one of the most rarely seen coronary artery anomalies. In addition, the specific subtype (Lipton RII-A) that our patient presented is one of the least common, and its clinical presentation as myocardial infarction and cardiac arrest has not been described in the literature. The case shows that although it is essential to exclude a malignant interarterial course of the vessel, cardiac arrest is a possible clinical presentation produced by myocardial ischemia in the context of acute myocardial infarction and should be managed according to clinical practice guidelines.
Asunto(s)
Anomalías de los Vasos Coronarios/complicaciones , Infarto del Miocardio/etiología , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana EdadRESUMEN
Nickel is the most frequent allergen in patients with allergic contact dermatitis and nickel allergy has been associated with recurrent in-stent restenosis. However, it is often misdiagnosed because of a low suspicion threshold. It should be discarded in patients with recurrent in-stent restenosis, especially if their medical history reveals prior contact dermatitis. It is also noteworthy and rarely specified that even newer generation stents that use novel metal alloys also contain low amounts of nickel. To avoid the implantation of new stents containing this metal, when percutaneous coronary intervention is indicated, drug eluting balloons or bioresorbable vascular scaffolds associated with small doses of steroids could provide good alternatives of treatment. To the best of our knowledge, this is the first description of this therapeutic alternative in such an exceedingly rare clinical scenario.