Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(1): 198-205, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38037864

RESUMEN

INTRODUCTION: The major limitation of the current cryoballoon (CB) system is a fixed 28 mm balloon-size. We sought to analyze real-world early experience with novel-sized adjustable CB. METHODS: This multicenter observational study included 140 consecutive atrial fibrillation patients (71 years, 94 men, 86 paroxysmal) who underwent pulmonary vein (PV) isolation using expandable diameter CB capable of ablation at 28 or 31 mm. RESULTS: Out of 544 targeted PVs, 526 (96.7%) were successfully isolated by a size-adjustable CB with a 770 [690-870] second median application dose, while the remaining 18 required touch-up ablation. Among them, 326 (62.0%) PVs were isolated by a 31 mm balloon, and the rate was significantly higher for upper than lower PVs (73.0% vs. 45.7%, p < .0001) and highest for right superior (78.5%) and lowest for right inferior (39.9%) PVs. The biophysical parameters and time to isolation were comparable between the 28 and 31 mm balloons, however, the real-time PV potential monitoring capability was significantly higher for 31 mm than 28 mm balloons for the left superior PV. The esophageal temperature reached 15°C during left inferior PV ablation significantly more often with 31 mm than 28 mm balloons (43.1% vs. 18.2%, p = .008). Right phrenic nerve injury (PNI) occurred in 9 (6.4%) patients during applications (6 right superior, 2 right inferior PVs), and most occurred with a 31 mm balloon. CONCLUSIONS: Our real-world early data demonstrated high acute efficacy and safety of the novel-sized adjustable CB. The biophysical parameters were similar between the 28 and 31 mm balloons. No marked decrease in the incidence of PNI was observed even with 31 mm balloons.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Femenino
2.
J Cardiovasc Electrophysiol ; 35(3): 505-510, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38178380

RESUMEN

INTRODUCTION: Dual atrioventricular nodal non-reentrant tachycardia (DAVNNT) is a rare and challenging-to-diagnose arrhythmia, without previous reports associating it with a leftward inferior extension (LIE). METHODS: Diagnosis was made using adenosine triphosphate (ATP) injection during atrial pacing in a suspected DAVNNT patient. RESULTS: Ablation of the rightward inferior extension was unsuccessful in eliminating DAVNNT; however, subsequent ablation of the LIE successfully eradicated the arrhythmia. CONCLUSION: This unique case, marked by the first instance of DAVNNT caused by LIE, diagnosed through ATP injection, underscores the utility of this diagnostic approach and broadens the spectrum of our understanding and management of this condition.


Asunto(s)
Ablación por Catéter , Polifosfatos , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Adenosina Trifosfato , Nodo Atrioventricular , Ablación por Catéter/efectos adversos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Adenosina , Arritmias Cardíacas , Electrocardiografía
3.
Artículo en Inglés | MEDLINE | ID: mdl-39188036

RESUMEN

BACKGROUND: Safety data of the latest radiofrequency (RF) technologies during atrial fibrillation (AF) ablation in real-world clinical practice are limited. OBJECTIVES: We sought to evaluate the acute procedural safety of the four latest ablation catheters commonly used for AF ablation. METHODS: A total of 3957 AF ablation procedures performed between January 2022 and December 2023 at 20 centers with either the THERMOCOOL SMARTTOUCH SF (STSF), TactiCath (TC), QDOT Micro (QDM), or TactiFlex (TF) were retrospectively analyzed. RESULTS: In total, QDM, STSF, TF, and TC were used in 343 (8.7%), 1793 (45.3%), 1121 (28.4%), and 700(17.7%) procedures. Among 2406 index procedures, electrical pulmonary vein isolations were successfully achieved in 99.5%. Despite similar total procedure times in the four groups, the total fluoroscopic time was significantly shorter for QDM/STSF with CARTO than TF/TC with EnSite (18.7 ± 14 vs. 27.6 ± 20.6 min, p < .001) and longest in the TF group. The incidence of cardiac tamponade was 0.7% (0.5% and 0.9% during index and redo procedures, 0.8% and 0.3% for paroxysmal and non-paroxysmal AF) and was significantly lower for QDM/STSF than TF/TC (0.2% vs. 1.1%, p = .008) and highest in the TF group. The incidence of cardiac tamponade was higher for TF than TC and STSF than QDM. In the multivariate analysis, TF/TC with EnSite was a significant independent predictor of cardiac tamponade during both the index (odds ratio [OR] = 4.8, 95% confidence interval [CI] = 1.3-17.5, p = .02) and all procedures (OR = 3.0, 95% CI = 1.3-7.2, p = .01). CONCLUSIONS: The incidence of cardiac tamponade and the fluoroscopic time during AF ablation significantly differed among the latest RF catheters and mapping systems in real-world clinical practice.

4.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38588039

RESUMEN

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Asunto(s)
Fibrilación Atrial , Criocirugía , Traumatismos de los Nervios Periféricos , Nervio Frénico , Venas Pulmonares , Sistema de Registros , Humanos , Nervio Frénico/lesiones , Masculino , Femenino , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Venas Pulmonares/cirugía , Anciano , Criocirugía/efectos adversos , Criocirugía/métodos , Estudios Prospectivos , Incidencia , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/epidemiología , Traumatismos de los Nervios Periféricos/prevención & control , Persona de Mediana Edad , Resultado del Tratamiento , Ablación por Catéter/efectos adversos
5.
J Cardiovasc Electrophysiol ; 34(2): 478-482, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36579408

RESUMEN

INTRODUCTION: Persistent left superior vena cava (PLSVC) is accompanied by enlarged coronary sinus (CS) and deformation of the triangle of Koch. This makes anatomical evaluation of the atrioventricular (AV) nodal pathways difficult. METHODS: We attempted cryoablation of retrograde fast pathway located in the enlarged CS roof of PLSVC for slow-fast AV nodal reentrant tachycardia (AVNRT) induced by inadvertent antegrade fast pathway elimination during ablation of left atrial tachycardia. RESULTS: Slow-fast AVNRT was successfully eliminated without AV block progression. CONCLUSIONS: This is the first case of successful retrograde fast pathway ablation of the CS ostial roof for slow-fast AVNRT with PLSVC.


Asunto(s)
Ablación por Catéter , Seno Coronario , Criocirugía , Vena Cava Superior Izquierda Persistente , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/cirugía
6.
J Cardiovasc Electrophysiol ; 34(12): 2484-2492, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37752712

RESUMEN

INTRODUCTION: Cryoballoon ablation (CBA) of the left atrial (LA) roof in addition to a pulmonary vein isolation has been expected to improve the clinical outcomes post-atrial fibrillation (AF) ablation. We demonstrated the characteristics and efficacy of CBA of the LA roof through our experience with a large volume of procedures. METHODS: Among 1036 AF ablation procedures with CBA of the LA roof, 834 patients who underwent a de novo ablation were analyzed. RESULTS: Complete LA roof line conduction block was obtained in 767 patients (92.0%) solely by CBA (Group A). Compared with the other patients (Group B), the mean nadir balloon temperature during CBA of the LA roof (-44.5 ± 5.6°C for Group A vs. -40.5 ± 7.5°C for Group B, p < .01) and number of cryoballoon applications during the LA roof ablation with a circular mapping catheter located in the left superior pulmonary vein (1.3 ± 0.8 for Group A vs. 1.6 ± 1.0 for Group B, p = .02) were significantly lower in Group A. A multivariate analysis revealed that those were predictors of a complete LA roof conduction block after only CBA. The 1-year Kaplan-Meier atrial arrhythmia free rate estimates were 80.6% for Group A and 59.0% for Group B (p < .01). CONCLUSION: Complete LA roof line conduction block could be obtained with a cryoballoon without touch-up ablation in most cases. The LA roof CBA with a circular mapping catheter located in the right superior pulmonary vein was preferable to obtaining complete LA roof conduction block, which was important with regard to the clinical outcomes.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Criocirugía/efectos adversos , Criocirugía/métodos , Atrios Cardíacos/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia
7.
Pacing Clin Electrophysiol ; 46(8): 882-889, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37493225

RESUMEN

BACKGROUND: Open-window mapping (OWM) is a novel automated mapping method for catheter ablation of an accessory pathway (AP), in which the local signal is annotated with window-of-interest parameters to analyze both atrial and ventricular signals. This study aimed to determine the utility of OWM in visualizing the location and width of APs in patients with Wolff-Parkinson-White syndrome. METHODS: This two-center study enrolled 30 patients (20 males; mean age: 56 years, interquartile range [IQR]: 22-69 years) who underwent high-density OWM with the extended early-meets-late (EEML) algorithm using a 20-electrode, 5-spline catheter (PENTARAY, Biosense Webster). The lower threshold of the EEML was set to adjust the EEML gap to match the propagation mapping, and broad APs were defined as an EEML gap > 1 cm. RESULTS: The median mapping points, mapping time, and lower threshold of the EEML were 2482 (IQR: 1755-4000) points, 23 (IQR: 15-30) min, and 23 (IQR: 18-25), respectively. All 30 APs (24 in the mitral annulus and 6 in the tricuspid annulus) were successfully eliminated. Of these APs, 21 (70%) were eliminated by the first radio frequency (RF) application. OWM revealed broad APs in 11 patients (37%), in four of whom (36%) the first RF application achieved a loss of AP conduction (vs. 90% of patients without broad APs; p = .004). CONCLUSION: OWM facilitates the visualization of the location and width of APs, which may be particularly useful for predicting whether multiple RF applications are required for broad APs.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Síndrome de Wolff-Parkinson-White , Masculino , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Síndrome de Wolff-Parkinson-White/cirugía , Fascículo Atrioventricular Accesorio/cirugía , Ablación por Catéter/métodos , Ventrículos Cardíacos , Ondas de Radio , Electrocardiografía
8.
Int Heart J ; 63(6): 1085-1091, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36450547

RESUMEN

Pulmonary vein isolation (PVI) with a balloon-based visually guided laser ablation (VGLA) is regarded as a useful therapeutic tool for treating atrial fibrillation (AF). The clinical efficacy of a VGLA has never been fully investigated in patients with left common pulmonary vein (LCPV). We investigated the procedural safety as well as clinical usefulness of VGLA in patients with LCPV.This study consisted of 130 consecutive patients who underwent VGLA of de novo nonvalvular paroxysmal AF.Eleven patients (8.5%) had an LCPV (ostium maximal average diameter: 27.5 ± 4.9 mm, ostium minimal average diameter: 17.7 ± 3.5 mm). Nine out of 11 (81.8%) LCPVs were successfully occluded and isolated at the ostium with a VGLA-guided PVI. The ablation procedure time was significantly shorter in the patients with than without an LCPV (61.5 ± 15.4 versus 86.9 ± 32.9 minutes, P = 0.01). There was no difference regarding the atrial tachyarrhythmia recurrence between those with and without an LCPV (P = 0.18). A total of 15 patients underwent a redo procedure, but reconnections were not observed in any of the LCPV patients.The VGLA-guided PVI was a useful therapeutic tool even in patients with an LCPV. The presence of an LCPV might not be associated with an increased risk of any atrial tachyarrhythmia recurrence.


Asunto(s)
Fibrilación Atrial , Terapia por Láser , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Atrios Cardíacos , Fibrilación Atrial/cirugía , Rayos Láser
9.
J Cardiovasc Electrophysiol ; 32(7): 1803-1811, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33969567

RESUMEN

BACKGROUND: Contrast computed tomography (CT) is a useful tool for the detection of intracardiac thrombi. We aimed to assess the accuracy of the late-phase prone-position contrast CT (late-pCT) for thrombus detection in patients with persistent or long-standing persistent atrial fibrillation (AF). METHODS: Early and late-phase pCT were performed in 300 patients with persistent or long-standing AF. If late-pCT did not show an intracardiac contrast defect (CD), catheter ablation (CA) was performed. Immediately before CA, intracardiac echocardiography (ICE) from the left atrium was performed to confirm thrombus absence and the estimation of the blood velocity of the left atrial appendage (LAA). For patients with CDs on late-pCT, CA performance was delayed, and late-pCT was performed again after several months following oral anticoagulant alterations or dosage increases. RESULTS: Of the 40 patients who exhibited CDs in the early phase of pCT, six showed persistent CDs on late-pCT. In the remaining 294 patients without CDs on late-pCT, the absence of a thrombus was confirmed by ICE during CA. In all six patients with CD-positivity on late-pCT, the CDs vanished under the same CT conditions after subsequent anticoagulation therapy, and CA was successfully performed. Furthermore, the presence of residual contrast medium in the LAA on late-pCT suggested a decreased blood velocity in the LAA ( ≤ 15 cm/s) (sensitivity = 0.900 and specificity = 0.621). CONCLUSIONS: Late-pCT is a valuable tool for the assessment of intracardiac thrombi and LAA dysfunction in patients with persistent or long-standing persistent AF before CA.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Trombosis , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ecocardiografía Transesofágica , Humanos , Posición Prona , Trombosis/diagnóstico por imagen , Trombosis/etiología , Tomografía Computarizada por Rayos X
10.
Circ J ; 85(3): 275-282, 2021 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-33536386

RESUMEN

BACKGROUND: Pulmonary vein (PV) isolation (PVI) with balloon-based visually guided laser ablation (VGLA) is useful for treating atrial fibrillation (AF), but phrenic nerve injury (PNI) is an important complication. We investigated the predictors of developing PNI during VGLA.Methods and Results:We included 130 consecutive patients who underwent an initial VGLA of non-valvular paroxysmal AF. Twenty patients developed PNI during the PVI. The patients with PNI had a significantly larger right superior PV ostial area (RSPVOA) than the other patients (mean [±SD] 284.7±47.0 vs. 233.1±46.4 mm2, respectively; P<0.01). Receiver operating characteristic analyses revealed that the area under the RSPVOA curve was 0.79 (95% confidence interval [CI] 0.69-0.90) with an optimal cut-off point of 238.0 mm2(sensitivity, 0.58; specificity, 0.95). In multivariate analyses, a large RSPVOA (HR 1.02, 95% CI 1.01-1.03, P<0.01) and small balloon size (HR 0.70, 95% CI 0.50-0.99, P=0.04) were independent risk factors for PNI during VGLA. PNI remained in 13 patients after the procedure, but 12 of these patients recovered from the PNI during the follow-up period. CONCLUSIONS: The incidence of PNI during VGLA was relatively high, but PNI improved in most cases. A large RSPVOA and small balloon size were predictors of PNI during VGLA.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Terapia por Láser , Traumatismos de los Nervios Periféricos , Nervio Frénico/lesiones , Venas Pulmonares , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Traumatismos de los Nervios Periféricos/etiología , Venas Pulmonares/cirugía , Resultado del Tratamiento
11.
Int Heart J ; 61(1): 39-45, 2020 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-31956141

RESUMEN

Patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) and hypertrophic cardiomyopathy (HCM) implanted with implantable cardioverter-defibrillators (ICDs) may show a large decrease in R-wave amplitude during long-term follow-up. However, it is unclear whether this decrease is higher in these patients than in those without structural heart disease. This study investigated ICD-lead intracardiac parameters over a long duration in patients with ARVC and HCM and compared these parameters with those of a control group. We included 50 patients (mean age, 55.2 ± 17.2 years; 26% female) with ICD leads in the right ventricular apex, and compared 7 ARVC and 14 HCM patients with 29 control patients without structural heart disease. ICD-lead parameters, including R-wave amplitude, pacing threshold, and impedance during follow-up, were compared. The difference in these parameters between the time of implantation and year 5 were also compared. There were no significant differences in R-wave amplitude at implantation among the 3 groups. The change in R-wave amplitude between the time of implantation and year 5 was significantly greater in the ARVC group (-3.3 ± 5.4 mV, P = 0.012) in comparison to the control group (1.3 ± 2.8 mV); the HCM group showed no significant difference (-0.4 ± 2.3 mV, P = 0.06). Thus, in the ARVC group, R-wave amplitude at year 5 was significantly lower than that in the control group (5.7 ± 4.8 mV versus 12.5 ± 4.5 mV, P = 0.001). In ARVC patients with ICDs, ventricular sensing is likely to deteriorate during long-term follow-up; however, in HCM patients, sensing may not deteriorate.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica/terapia , Cardiomiopatía Hipertrófica/terapia , Ventrículos Cardíacos/fisiopatología , Adolescente , Adulto , Anciano , Displasia Ventricular Derecha Arritmogénica/fisiopatología , Cardiomiopatía Hipertrófica/fisiopatología , Estudios de Casos y Controles , Desfibriladores Implantables , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
12.
J Cardiovasc Electrophysiol ; 29(10): 1379-1387, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30016003

RESUMEN

BACKGROUND: Differential pacing technique to confirm mitral isthmus (MI) block is sometimes challenging due to destroyed tissues after extensive ablation. The purpose of this study is to set an endpoint of MI ablation using conduction time around the mitral annulus (MA). METHODS: Forty-five consecutive patients with persistent atrial fibrillation who received MI linear ablation were included. The geometry and activation times of the left atrium around the MA were collected using a multipolar catheter before ablation. During coronary sinus (CS) pacing, the time between the stimulus and the wave-front collision at the opposite side of the MA (defined as T/2) was calculated, and the doubled value was defined as the estimated perimitral conduction time (E-PMCT). The endpoint for complete MI block was when the stimulus (at distal CS) minus the maximal delayed potential (St-MDP) on the MI interval reached the E-PMCT. RESULTS: St-MDP reached E-PMCT during MI ablation in 44/45 patients. Among these 44 patients, differential pacing revealed bidirectional block in 39/44 (88.6%), whereas in 5/44 (11.4%), the differential pacing was not possible because of the loss of capture of local potentials due to extensive applications around the linear line. In one patient, the St-MDP did not reach E-PMCT (E-PMCT: 148 ms, St-MDP :130 ms) and differential pacing revealed no MI block. E-PMCT values (median 176 ms) correlated strongly with St-MDP (median 185 ms, P < 0.0001, R = 0.98). CONCLUSIONS: Although E-PMCT differs between individuals, the value is significantly correlated with the St-MDP. This technique may be useful in providing an individual endpoint of MI ablation as an alternative to differential pacing.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Estimulación Cardíaca Artificial , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Válvula Mitral/cirugía , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
13.
Circ J ; 82(8): 2032-2040, 2018 07 25.
Artículo en Inglés | MEDLINE | ID: mdl-29910223

RESUMEN

BACKGROUND: The in vivo lesion morphologies and plaque components of coronary chronic total occlusion (CTO) lesions remain unclear.Methods and Results:We investigated 57 consecutive CTO lesions in 57 patients with stable angina pectoris undergoing elective percutaneous coronary intervention with intravascular ultrasound (IVUS) and coronary angioscopy (CAS) examination. All CTO lesions were classified according to the proximal angiographic lumen pattern; tapered-type (T-CTO) and abrupt-type (A-CTO). The differences in the intracoronary images of these lesion types were evaluated according to the location within the CTO segment. A total of 35 lesions (61.4%) were T-CTO. T-CTO lesions had higher frequencies of red thrombi (proximal 71.4%; middle 74.3%; distal 31.4%; P<0.001) and bright-yellow plaques (yellow-grade 2-3) (48.6%; 74.3%; 2.9%; P<0.001) at the proximal or middle than at the distal subsegment; A-CTO lesions showed no significant differences among the 3 sub-segments. At the middle subsegment, T-CTO lesions showed higher frequencies of positive remodeling (51.4% vs. 18.2%, P=0.01) and bright-yellow plaques (74.3% vs. 13.6%, P<0.001) compared with A-CTO lesions. Multivariate analysis identified bright-yellow plaque as an independent predictor (odds ratio, 7.25; 95% confidence interval, 1.25-42.04; P=0.03) of the occurrence of periprocedural myocardial necrosis. CONCLUSIONS: The combination of IVUS and CAS analysis may be useful for identifying lesion morphology and plaque components, which may help clarify the pathogenetic mechanism of CTO lesions.


Asunto(s)
Angioscopía/métodos , Oclusión Coronaria/diagnóstico , Placa Aterosclerótica/diagnóstico , Ultrasonografía Intervencional/métodos , Anciano , Color , Oclusión Coronaria/diagnóstico por imagen , Humanos , Persona de Mediana Edad , Miocardio/patología , Necrosis , Placa Aterosclerótica/diagnóstico por imagen , Estudios Retrospectivos
14.
Int Heart J ; 59(6): 1462-1465, 2018 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-30369581

RESUMEN

Non-obstructive angioscopy has become a novel method of evaluating atheromatous plaques of the aortic intimal wall. A 77-year-old man with coronary artery disease underwent percutaneous coronary intervention in the left descending artery. We subsequently used non-obstructive angioscopy to identify aortic atheromatous plaques and incidentally diagnosed an aortic dissecting aneurysm. Non-obstructive angioscopy demonstrated a great fissure in severe atheromatous plaques at the entry site of the aortic dissection identified by enhanced computed tomography. This is the first report to describe the aortic intimal findings of an aortic dissecting aneurysm in vivo by using trans-catheter angioscopy.


Asunto(s)
Angioscopía/métodos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Disección Aórtica/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/complicaciones , Anciano , Disección Aórtica/etiología , Aneurisma de la Aorta Abdominal/etiología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Humanos , Hallazgos Incidentales , Masculino , Intervención Coronaria Percutánea
15.
Int Heart J ; 59(5): 1026-1033, 2018 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-30012924

RESUMEN

Japan is facing problems associated with "heart failure (HF) pandemics" and bed shortages in core hospitals that can accommodate patients with acute HF. The prognosis is currently unknown for acute HF patients who were transferred from core hospitals to collaborating hospitals during the very early treatment phase and whose treatment strategies are in place.We enrolled 166 acute HF patients who were hospitalized between January 1, 2015, and December 31, 2015, and compared the conditions of transferred patients (n = 53, median duration before transfer = 6 days) and nontransferred patients (n = 113). The transferred and nontransferred patients had similar one-year mortality rates (24.5% versus 19.5%, log-rank P = 0.27) and composite one-year mortality and HF readmission rates (35.8% versus 31.0%, log-rank P = 0.32). Multivariate analysis determined that patient transfers were not associated with a higher composite endpoint (hazard ratio, 1.08; 95% confidence interval, 0.58-1.99, P = 0.82). Transferred patients with low composite congestion scores (CCSs) had significantly lower composite endpoints than those with high CCSs (23.5% versus 57.9%, log-rank P = 0.005).Acute HF patients who were transferred did not have inferior prognoses compared with nontransferred patients when the treatment strategies were correctly assumed by cardiologists. The implementation of early and strict decongestion strategies before transfer may be important for reducing cardiovascular events.


Asunto(s)
Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Hospitalización/estadística & datos numéricos , Transferencia de Pacientes/métodos , Transferencia de Pacientes/estadística & datos numéricos , Enfermedad Aguda , Anciano , Anciano de 80 o más Años , Femenino , Insuficiencia Cardíaca/diagnóstico , Hospitalización/tendencias , Humanos , Japón/epidemiología , Masculino , Mortalidad/tendencias , Readmisión del Paciente/estadística & datos numéricos , Prevalencia , Pronóstico , Análisis de Supervivencia
16.
Circ J ; 79(9): 1944-53, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26095152

RESUMEN

BACKGROUND: Periprocedural myocardial injury (PMI) is not an uncommon complication and is related to adverse cardiac events after percutaneous coronary intervention (PCI). We investigated the predictors of PMI in patients with stable angina pectoris (SAP) on intravascular imaging. METHODS AND RESULTS: We enrolled 193 SAP patients who underwent pre-PCI intravascular ultrasound (IVUS) and optical coherence tomography (OCT). Clinical characteristics, lesion morphology, and long-term follow-up data were compared between patients with and without PMI, defined as post-PCI elevation of high-sensitivity cardiac troponin-T. PMI were observed in 79 patients (40.9%). Estimated glomerular filtration rate (odds ratio [OR], 0.973; 95% confidence interval [CI]: 0.950-0.996; P=0.020), ≥2 stents (OR, 3.100; 95% CI: 1.334-7.205; P=0.009), final myocardial blush grade 0-2 (OR, 4.077; 95% CI: 1.295-12.839; P=0.016), and IVUS-identified echo-attenuated plaque (EA; OR, 3.623; 95% CI: 1.700-7.721; P<0.001) and OCT-derived thin-cap fibroatheroma (OCT-TCFA; OR, 3.406; 95% CI: 1.307-8.872; P=0.012) were independent predictors of PMI on multivariate logistic regression analysis. A combination of EA and OCT-TCFA had an 82.4% positive predictive value for PMI. On Cox proportional hazards analysis, PMI was an independent predictor of adverse cardiac events during 1-year follow-up (hazard ratio, 2.984; 95% CI: 1.209-7.361; P=0.018). CONCLUSIONS: Plaque morphology assessment using pre-PCI IVUS and OCT may be useful for predicting PMI in SAP patients.


Asunto(s)
Angina Estable/patología , Enfermedad de la Arteria Coronaria/patología , Lesiones Cardíacas/epidemiología , Miocardio , Placa Aterosclerótica/patología , Tomografía de Coherencia Óptica/efectos adversos , Ultrasonografía Intervencional/efectos adversos , Anciano , Femenino , Estudios de Seguimiento , Lesiones Cardíacas/etiología , Lesiones Cardíacas/patología , Humanos , Masculino , Persona de Mediana Edad
17.
J Interv Card Electrophysiol ; 67(1): 5-12, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38087145

RESUMEN

BACKGROUND: Single-shot pulmonary vein isolation (PVI) utilizing cryothermal energy is an effective and safe treatment for atrial fibrillation (AF) patients. A novel cryoballoon system, POLARx™, has been recently introduced. The aim of this study was to compare the efficacy, safety, and biophysical parameters of PVI between the novel cryoballoon system, POLARx™, and the standard cryoballoon system, Arctic Front Advance Pro™ (AFA-Pro), in patients with paroxysmal AF. METHODS: The CONTRAST-CRYO trial is a prospective, multicenter, open-label, randomized controlled study performed at seven large cardiac centers. This study was approved by the central ethics committee or the local ethics committee of each participating hospital and has been registered at UMIN Clinical Trials Registry (UMIN000049948). The trial will assign 200 patients with paroxysmal AF undergoing PVI to POLARx™ and AFA-Pro in a 1:1 randomization. The primary endpoint is the one-shot acute success rate of the right inferior pulmonary vein. Second endpoints include freedom from documented atrial fibrillation, atrial flutter, or atrial tachycardia without antiarrhythmic drugs at 12 months after the procedure, freedom from re-do procedures, the incidence of procedure-related adverse events, freezing duration, and the biophysical parameters during applications for each PV, total procedure and fluoroscopy time, and PVI durability during re-do procedures. CONCLUSION: The CONTRAST-CRYO trial is a prospective, multicenter, randomized study designed to elucidate the difference in the efficacy, safety, and biophysical parameters between POLARx™ and AFA-Pro in paroxysmal AF patients undergoing PVI. The findings from this trial may provide a valuable indication for selecting the optimal cryoballoon system. CLINICAL TRIAL REGISTRATION:  UMIN000049948.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Resultado del Tratamiento , Estudios Prospectivos , Criocirugía/métodos , Antiarrítmicos , Venas Pulmonares/cirugía , Ablación por Catéter/métodos , Recurrencia , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto
18.
Heart Rhythm ; 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38797309

RESUMEN

BACKGROUND: The anatomical approach for the management of para-Hisian ventricular arrhythmias (VAs) with QRS morphological changes after catheter ablation (CA) has not been well investigated. OBJECTIVE: We aimed to evaluate the electrocardiographic and electrophysiological findings and ablation outcomes of para-Hisian VAs with QRS morphological changes after CA. METHODS: Of the 30 patients who underwent CA for para-Hisian VAs at 4 institutions, 10 (33%) had QRS morphological changes after ablation. All 10 patients underwent an anatomical approach, targeting the site anatomically opposite to the site where the QRS morphology had been changed by ablation. We investigated the safety and efficacy of the anatomical approach. RESULTS: Of the 10 patients evaluated, the approach was switched from the right ventricular septum to the left ventricular septum/aortic root in 7 (70%) (RL group) whereas 3 (30%) underwent left-to-right switches (LR group). After CA, the precordial transition zone tended to be earlier in the RL group and later in the LR group. In the RL group, successful VA suppression was achieved, despite suboptimal pace map concordance from the left side or a relatively delayed earliest activation time. Of the 10 patients who underwent an anatomical approach, 8 (80%) had procedural success, and ablation was discontinued in 1 (10%) because of the risk of atrioventricular block. CONCLUSION: The anatomical approach showed promising results regarding safety and efficacy. Therefore, it should be considered when QRS morphological changes are observed during or after CA of para-Hisian VAs.

19.
Front Cardiovasc Med ; 10: 1278603, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37965084

RESUMEN

Background: Symptomatic gastric hypomotility (SGH) is a rare but major complication of atrial fibrillation (AF) ablation, but data on this are scarce. Objective: We compared the clinical course of SGH occurring with different energy sources. Methods: This multicenter study retrospectively collected the characteristics and clinical outcomes of patients with SGH after AF ablation. Results: The data of 93 patients (67.0 ± 11.2 years, 68 men, 52 paroxysmal AF) with SGH after AF ablation were collected from 23 cardiovascular centers. Left atrial (LA) ablation sets included pulmonary vein isolation (PVI) alone, a PVI plus a roof-line, and an LA posterior wall isolation in 42 (45.2%), 11 (11.8%), and 40 (43.0%) patients, respectively. LA ablation was performed by radiofrequency ablation, cryoballoon ablation, or both in 38 (40.8%), 38 (40.8%), and 17 (18.3%) patients, respectively. SGH diagnoses were confirmed at 2 (1-4) days post-procedure, and 28 (30.1%) patients required re-hospitalizations. Fasting was required in 81 (92.0%) patients for 4 (2.5-5) days; the total hospitalization duration was 11 [7-19.8] days. After conservative treatment, symptoms disappeared in 22.3% of patients at 1 month, 48.9% at 2 months, 57.6% at 3 months, 84.6% at 6 months, and 89.7% at 12 months, however, one patient required surgery after radiofrequency ablation. Symptoms persisted for >1-year post-procedure in 7 patients. The outcomes were similar regardless of the energy source and LA lesion set. Conclusions: The clinical course of SGH was similar regardless of the energy source. The diagnosis was often delayed, and most recovered within 6 months, yet could persist for over 1 year in 10%.

20.
JACC Case Rep ; 4(7): 418-423, 2022 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-35693910

RESUMEN

Cryoballoon ablation is an effective method for pulmonary vein isolation for atrial fibrillation; however, unexpected complications may occur while performing the ablation procedure. We report an extremely rare case of pulmonary vein perforation with hemoptysis that required emergency lobectomy caused by injury from a circular mapping catheter. (Level of Difficulty: Intermediate.).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA