J Biomech Eng ; 137(4): 045001, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25587891

RESUMEN

Due to expensive nature of clinical trials, implantable cardiac devices should first be extensively characterized in vitro. Prosthetic heart valves (PHVs), an important class of these devices, have been shown to be associated with thromboembolic complications. Although various in vitro systems have been designed to quantify blood-cell damage and platelet activation caused by nonphysiological hemodynamic shear stresses in these PHVs, very few systems attempt to characterize both blood damage and fluid dynamics aspects of PHVs in the same test system. Various numerical modeling methodologies are also evolving to simulate the structural mechanics, fluid mechanics, and blood damage aspects of these devices. This article presents a completely hemocompatible small-volume test-platform that can be used for thrombogenicity studies and experimental fluid mechanics characterization. Using a programmable piston pump to drive freshly drawn human blood inside a cylindrical column, the presented system can simulate various physiological and pathophysiological conditions in testing PHVs. The system includes a modular device-mounting chamber, and in this presented case, a 23 mm St. Jude Medical (SJM) Regents® mechanical heart valve (MHV) in aortic position was used as the test device. The system was validated for its capability to quantify blood damage by measuring blood damage induced by the tester itself (using freshly drawn whole human blood). Blood damage levels were ascertained through clinically relevant assays on human blood while fluid dynamics were characterized using time-resolved particle image velocimetry (PIV) using a blood-mimicking fluid. Blood damage induced by the tester itself, assessed through Thrombin-anti-Thrombin (TAT), Prothrombin factor 1.2 (PF1.2), and hemolysis (Drabkins assay), was within clinically accepted levels. The hydrodynamic performance of the tester showed consistent, repeatable physiological pressure and flow conditions. In addition, the system contains proximity sensors to accurately capture leaflet motion during the entire cardiac cycle. The PIV results showed skewing of the leakage jet, caused by the asymmetric closing of the two leaflets. All these results are critical to characterizing the blood damage and fluid dynamics characteristics of the SJM Regents® MHV, proving the utility of this tester as a precise system for assessing the hemodynamics and thrombogenicity for various PHVs.


Asunto(s)
Prótesis Valvulares Cardíacas/efectos adversos , Ensayo de Materiales/instrumentación , Flujo Pulsátil , Tromboembolia/etiología , Humanos , Hidrodinámica , Activación Plaquetaria , Presión , Diseño de Prótesis , Reología , Tromboembolia/fisiopatología , Adulto Joven
2.
J Biomech Eng ; 136(9): 091008, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24976188

RESUMEN

The hinge regions of the bileaflet mechanical heart valve (BMHV) can cause blood element damage due to nonphysiological shear stress levels and regions of flow stasis. Recently, a micro particle image velocimetry (µPIV) system was developed to study whole flow fields within BMHV hinge regions with enhanced spatial resolution under steady leakage flow conditions. However, global velocity maps under pulsatile conditions are still necessary to fully understand the blood damage potential of these valves. The current study hypothesized that the hinge gap width will affect flow fields in the hinge region. Accordingly, the blood damage potential of three St. Jude Medical (SJM) BMHVs with different hinge gap widths was investigated under pulsatile flow conditions, using a µPIV system. The results demonstrated that the hinge gap width had a significant influence during the leakage flow phase in terms of washout and shear stress characteristics. During the leakage flow, the largest hinge gap generated the highest Reynolds shear stress (RSS) magnitudes (~1000 N/m²) among the three valves at the ventricular side of the hinge. At this location, all three valves indicated viscous shear stresses (VSS) greater than 30 N/m². The smallest hinge gap exhibited the lowest level of shear stress values, but had the poorest washout flow characteristics among the three valves, demonstrating propensity for flow stasis and associated activated platelet accumulation potential. The results from this study indicate that the hinge is a critical component of the BMHV design, which needs to be optimized to find the appropriate balance between reduction in fluid shear stresses and enhanced washout during leakage flow, to ensure minimal thrombotic complications.


Asunto(s)
Sangre , Prótesis Valvulares Cardíacas/efectos adversos , Reología , Estrés Mecánico , Modelos Teóricos , Flujo Pulsátil , Resistencia al Corte
3.
J Biomech Eng ; 135(2): 021007, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23445052

RESUMEN

The mitral valve is a complex apparatus with multiple constituents that work cohesively to ensure unidirectional flow between the left atrium and ventricle. Disruption to any or all of the components-the annulus, leaflets, chordae, and papillary muscles-can lead to backflow of blood, or regurgitation, into the left atrium, which deleteriously effects patient health. Through the years, a myriad of surgical repairs have been proposed; however, a careful appreciation for the underlying structural mechanics can help optimize long-term repair durability and inform medical device design. In this review, we aim to present the experimental methods and significant results that have shaped the current understanding of mitral valve mechanics. Data will be presented for all components of the mitral valve apparatus in control, pathological, and repaired conditions from human, animal, and in vitro studies. Finally, current strategies of patient specific and noninvasive surgical planning will be critically outlined.


Asunto(s)
Salud , Cardiopatías/fisiopatología , Fenómenos Mecánicos , Válvula Mitral/fisiología , Válvula Mitral/fisiopatología , Animales , Fenómenos Biomecánicos , Prótesis Vascular , Cardiopatías/patología , Humanos , Válvula Mitral/citología , Válvula Mitral/patología
4.
J Biomech Eng ; 135(9): 94502, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23720100

RESUMEN

Mitral annular calcification (MAC) involves calcium deposition in the fibrous annulus supporting the mitral valve (MV). When calcification extends onto the leaflets, valve opening can be restricted. The influence of MAC MV geometry on Doppler gradients is unknown. This study describes a novel methodology to rapid-prototype subject-specific MAC MVs. Replicated valves were used to assess the effects of distorted annular-leaflet geometry on Doppler-derived, transmitral gradients in comparison to direct pressure measurements and to determine if transmitral gradients vary according to measurement location. Three-dimensional echocardiography data sets were selected for two MAC MVs and one healthy MV. These MVs were segmented and rapid prototyped in their middiastolic configuration for in vitro testing. The effects of MV geometry, measurement modality, and measurement location on transmitral pressure gradient were assessed by Doppler and catheter at three locations along the MV's intercommissural axis. When comparing dimensions of the rapid-prototyped valves to the subject echocardiography data sets, mean relative errors ranged from 6.2% to 35%. For the evaluated MVs, Doppler pressure gradients exhibited good agreement with catheter-measured gradients at a variety of flow rates, though with slight systematic overestimation in the recreated MAC valves. For all of the tested MVs, measuring the transmitral pressure gradient at differing valve orifice positions had minimal impact on observed gradients. Upon the testing of additional normal and calcific MVs, these data may contribute to an improved clinical understanding of MAC-related mitral stenosis. Moreover, they provide the ability to statistically evaluate between measurement locations, flow rates, and valve geometries for Doppler-derived pressure gradients. Determining these end points will contribute to greater clinical understanding for the diagnosis MAC patients and understanding the use and application of Doppler echocardiography to estimate transmitral pressure gradients.


Asunto(s)
Calcinosis/diagnóstico por imagen , Catéteres , Ecocardiografía Doppler , Imagenología Tridimensional/métodos , Válvula Mitral/diagnóstico por imagen , Presión , Humanos
5.
Am J Physiol Heart Circ Physiol ; 303(6): H721-31, 2012 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-22821994

RESUMEN

The bicuspid aortic valve (BAV) is a common congenital malformation of the aortic valve (AV) affecting 1% to 2% of the population. The BAV is predisposed to early degenerative calcification of valve leaflets, and BAV patients constitute 50% of AV stenosis patients. Although evidence shows that genetic defects can play a role in calcification of the BAV leaflets, we hypothesize that drastic changes in the mechanical environment of the BAV elicit pathological responses from the valve and might be concurrently responsible for early calcification. An in vitro model of the BAV was constructed by surgically manipulating a native trileaflet porcine AV. The BAV valve model and a trileaflet AV (TAV) model were tested in an in vitro pulsatile flow loop mimicking physiological hemodynamics. Laser Doppler velocimetry was used to make measurements of fluid shear stresses on the leaflet of the valve models using previously established methodologies. Furthermore, particle image velocimetry was used to visualize the flow fields downstream of the valves and in the sinuses. In the BAV model, flow near the leaflets and fluid shear stresses on the leaflets were much more unsteady than for the TAV model, most likely due to the moderate stenosis in the BAV and the skewed forward flow jet that collided with the aorta wall. This additional unsteadiness occurred during mid- to late-systole and was composed of cycle-to-cycle magnitude variability as well as high-frequency fluctuations about the mean shear stress. It has been demonstrated that the BAV geometry can lead to unsteady shear stresses under physiological flow and pressure conditions. Such altered shear stresses could play a role in accelerated calcification in BAVs.


Asunto(s)
Válvula Aórtica/anomalías , Válvula Aórtica/fisiopatología , Calcinosis/etiología , Cardiopatías Congénitas/fisiopatología , Hemodinámica , Animales , Fenómenos Biomecánicos , Presión Sanguínea , Calcinosis/genética , Calcinosis/fisiopatología , Predisposición Genética a la Enfermedad , Cardiopatías Congénitas/genética , Técnicas In Vitro , Flujometría por Láser-Doppler , Modelos Cardiovasculares , Flujo Pulsátil , Factores de Riesgo , Estrés Mecánico , Porcinos , Factores de Tiempo
6.
J Biomech Eng ; 133(6): 061007, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21744927

RESUMEN

Aortic valve (AV) calcification is a highly prevalent disease with serious impact on mortality and morbidity. The exact cause and mechanism of the progression of AV calcification is unknown, although mechanical forces have been known to play a role. It is thus important to characterize the mechanical environment of the AV. In the current study, we establish a methodology of measuring shear stresses experienced by the aortic surface of the AV leaflets using an in vitro valve model and adapting the laser Doppler velocimetry (LDV) technique. The valve model was constructed from a fresh porcine aortic valve, which was trimmed and sutured onto a plastic stented ring, and inserted into an idealized three-lobed sinus acrylic chamber. Valve leaflet location was measured by obtaining the location of highest back-scattered LDV laser light intensity. The technique of performing LDV measurements near to biological surfaces as well as the leaflet locating technique was first validated in two phantom flow systems: (1) steady flow within a straight tube with AV leaflet adhered to the wall, and (2) steady flow within the actual valve model. Dynamic shear stresses were then obtained by applying the techniques on the valve model in a physiologic pulsatile flow loop. Results show that aortic surface shear stresses are low during early systole (<5 dyn/cm²) but elevated to its peak during mid to late systole at about 18-20 dyn/cm². Low magnitude shear stress (<5 dyn/cm²) was observed during early diastole and dissipated to zero over the diastolic duration. Systolic shear stress was observed to elevate only with the formation of sinus vortex flow. The presented technique can also be used on other in vitro valve models such as congenitally geometrically malformed valves, or to investigate effects of hemodynamics on valve shear stress. Shear stress data can be used for further experiments investigating effects of fluid shear stress on valve biology, for conditioning tissue engineered AV, and to validate numerical simulations.


Asunto(s)
Válvula Aórtica/fisiología , Animales , Fenómenos Biomecánicos , Ingeniería Biomédica , Calcinosis/fisiopatología , Enfermedades de las Válvulas Cardíacas/fisiopatología , Hemorreología , Humanos , Técnicas In Vitro , Flujometría por Láser-Doppler , Modelos Animales , Modelos Cardiovasculares , Flujo Pulsátil , Porcinos
9.
Cardiovasc Eng Technol ; 10(3): 397-422, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31240664

RESUMEN

PURPOSE: Hydrodynamic performance testing is one of the core in vitro assessments required by the ISO 5840 series of standards for all prosthetic heart valves. A round-robin study carried out in 2005 in accordance with ISO 5840:2005 revealed significant variabilities in prosthetic heart valve hydrodynamic performance measurements among the participating laboratories. In order to re-examine the inter-laboratory variability based on the "state-of-the-art" under ISO 5840-1 and 5840-2:2015, the ISO Cardiac Valve Working Groups decided in 2016 to repeat the round-robin study. METHODS: A total of 13 international laboratories participated in the study. The test valves were chosen to be the St. Jude Medical Masters Series mechanical valves (19 mm aortic, 25 mm aortic, 25 mm mitral, and 31 mm mitral), which were circulated among the laboratories. The testing was conducted according to a common test run sequence, with prespecified flow conditions. RESULTS: The study revealed improved, yet still significant variability among different laboratories as compared to the 2005 study. The coefficient of variation ranged from 7.7 to 21.6% for the effective orifice area, from 10.1 to 32.8% for the total regurgitant fraction, and from 14.7 to 45.5% for the mean transvalvular pressure gradient. CONCLUSIONS: The study revealed the ambiguities in the current versions of the ISO 5840 series of standards and the shortcomings of some participating laboratories. This information has allowed the ISO Working Group to incorporate additional clarifying language into the ISO 5840-1, -2, and -3 standards that are currently under revision to improve in vitro assessments. The results presented here can also be used by the testing laboratories to benchmark pulse duplicator systems and to train and certify testing personnel.


Asunto(s)
Prótesis Valvulares Cardíacas/normas , Ensayos de Aptitud de Laboratorios/normas , Diseño de Prótesis/normas , Flujo Pulsátil , Presión Arterial , Gasto Cardíaco , Frecuencia Cardíaca , Humanos , Hidrodinámica , Ensayo de Materiales , Variaciones Dependientes del Observador , Sístole
10.
Cardiovasc Eng Technol ; 9(3): 273-287, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29532332

RESUMEN

Experimental flow field characterization is a critical component of the assessment of the hemolytic and thrombogenic potential of heart valve substitutes, thus it is important to identify best practices for these experimental techniques. This paper presents a brief review of commonly used flow assessment techniques such as Particle image velocimetry (PIV), Laser doppler velocimetry, and Phase contrast magnetic resonance imaging and a comparison of these methodologies. In particular, recommendations for setting up planar PIV experiments such as recommended imaging instrumentation, acquisition and data processing are discussed in the context of heart valve flows. Multiple metrics such as residence time, local velocity and shear stress that have been identified in the literature as being relevant to hemolysis and thrombosis in heart valves are discussed. Additionally, a framework for uncertainty analysis and data reporting for PIV studies of heart valves is presented in this paper. It is anticipated that this paper will provide useful information for heart valve device manufacturers and researchers to assess heart valve flow fields for the potential for hemolysis and thrombosis.


Asunto(s)
Benchmarking , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Hemodinámica , Flujometría por Láser-Doppler , Imagen por Resonancia Magnética , Ensayo de Materiales/métodos , Animales , Benchmarking/normas , Velocidad del Flujo Sanguíneo , Prótesis Valvulares Cardíacas/normas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/normas , Hemólisis , Humanos , Flujometría por Láser-Doppler/normas , Imagen por Resonancia Magnética/normas , Ensayo de Materiales/normas , Modelos Estadísticos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Estrés Mecánico , Trombosis/sangre , Trombosis/etiología , Trombosis/fisiopatología , Incertidumbre
11.
Biomech Model Mechanobiol ; 14(3): 577-88, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25262451

RESUMEN

Congenital bicuspid aortic valves (BAVs) are associated with accelerated disease progression, such as leaflet calcification and ascending aorta dilatation. Although common underlying genetic factors have been implicated in accelerated disease in BAV patients, several studies have suggested that altered hemodynamics also play a role in this disease process. The present study compares turbulence and wall shear stress (WSS) measurements between various BAV and trileaflet aortic valve (TAV) models to provide information for mechanobiological models of BAV disease. BAV and TAV models were constructed from excised porcine aortic valves to simulate parametric variations in BAV stenosis, hemodynamics and geometry. Particle image velocimetry experiments were conducted at physiological pressure conditions to characterize velocity fields in the ascending aorta. The velocity fields were post-processed to calculate turbulence, viscous and wall shear stresses in the ascending aorta. Stenosed BAV models showed the presence of eccentric systolic jets, causing increased WSS. Lower cardiac output resulted in a narrower jet, lower turbulence and lower viscous shear stress (VSS). The specific severe stenosis BAV model studied here showed reduced WSS due to reduction in non-fused leaflet mobility. Dilation of the aorta did not affect any turbulence or VSS, but reduced the WSS. In comparison with BAVs, TAVs have similar VSS values, but much smaller WSS and turbulence levels. These increased turbulence  and WSS levels in BAVs may play a key role in amplifying the biological responses of the ascending aorta wall and valvular leaflets, and support the hemodynamic underpinnings of BAV disease processes.


Asunto(s)
Válvula Aórtica/anomalías , Estrés Mecánico , Válvula Aórtica/fisiología , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Humanos , Modelos Biológicos
12.
J R Soc Interface ; 12(113): 20150737, 2015 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-26674192

RESUMEN

Transcatheter aortic valve replacements (TAVRs) are a percutaneous alternative to surgical aortic valve replacements and are used to treat patients with aortic valve stenosis. This minimally invasive procedure relies on expansion of the TAVR stent to radially displace calcified aortic valve leaflets against the aortic root wall. However, these calcium deposits can impede the expansion of the device causing distortion of the valve stent and pericardial tissue leaflets. The objective of this study was to elucidate the impact of eccentric TAVR stent distortion on the dynamic deformation of the tissue leaflets of the prosthesis in vitro. Dual-camera stereophotogrammetry was used to measure the regional variation in strain in a leaflet of a TAVR deployed in nominal circular and eccentric (eccentricity index = 28%) orifices, representative of deployed TAVRs in vivo. It was observed that (i) eccentric stent distortion caused incorrect coaptation of the leaflets at peak diastole resulting in a 'peel-back' leaflet geometry that was not present in the circular valve and (ii) adverse bending of the leaflet, arising in the eccentric valve at peak diastole, caused significantly higher commissure strains compared with the circular valve in both normotensive and hypertensive pressure conditions (normotension: eccentric = 13.76 ± 2.04% versus circular = 11.77 ± 1.61%, p = 0.0014, hypertension: eccentric = 15.07 ± 1.13% versus circular = 13.56 ± 0.87%, p = 0.0042). This study reveals that eccentric distortion of a TAVR stent can have a considerable impact on dynamic leaflet deformation, inducing deleterious bending of the leaflet and increasing commissures strains, which might expedite leaflet structural failure compared to leaflets in a circular deployed valve.


Asunto(s)
Válvulas Cardíacas , Modelos Cardiovasculares , Pericardio , Stents , Reemplazo de la Válvula Aórtica Transcatéter , Humanos
13.
Artículo en Inglés | MEDLINE | ID: mdl-24059354

RESUMEN

Computational models for the heart's mitral valve (MV) exhibit several uncertainties that may be reduced by further developing these models using ground-truth data-sets. This study generated a ground-truth data-set by quantifying the effects of isolated mitral annular flattening, symmetric annular dilatation, symmetric papillary muscle (PM) displacement and asymmetric PM displacement on leaflet coaptation, mitral regurgitation (MR) and anterior leaflet strain. MVs were mounted in an in vitro left heart simulator and tested under pulsatile haemodynamics. Mitral leaflet coaptation length, coaptation depth, tenting area, MR volume, MR jet direction and anterior leaflet strain in the radial and circumferential directions were successfully quantified at increasing levels of geometric distortion. From these data, increase in the levels of isolated PM displacement resulted in the greatest mean change in coaptation depth (70% increase), tenting area (150% increase) and radial leaflet strain (37% increase) while annular dilatation resulted in the largest mean change in coaptation length (50% decrease) and regurgitation volume (134% increase). Regurgitant jets were centrally located for symmetric annular dilatation and symmetric PM displacement. Asymmetric PM displacement resulted in asymmetrically directed jets. Peak changes in anterior leaflet strain in the circumferential direction were smaller and exhibited non-significant differences across the tested conditions. When used together, this ground-truth data-set may be used to parametrically evaluate and develop modelling assumptions for both the MV leaflets and subvalvular apparatus. This novel data may improve MV computational models and provide a platform for the development of future surgical planning tools.


Asunto(s)
Insuficiencia de la Válvula Mitral/fisiopatología , Válvula Mitral/fisiopatología , Animales , Fenómenos Biomecánicos , Simulación por Computador , Dilatación Patológica , Corazón/fisiología , Hemodinámica , Modelos Cardiovasculares , Músculos Papilares/fisiopatología , Ovinos
14.
Ann Biomed Eng ; 43(8): 1815-27, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25533768

RESUMEN

Bicuspid aortic valve (BAV) is the most common congenital heart defect and can lead to severe complications. Many studies have been conducted to evaluate the potential of geometric and hemodynamic biomarkers to predict BAV-related aortopathy. This work proposes a novel semi-automatic protocol to characterize geometry and hemodynamics of aorta and aortic valve based on 2D cine and 4D flow MRI data. The protocol was applied to 12 BAV and 12 control subjects. Statistical differences between the groups were identified and linear regression models were investigated to elucidate the potential of this protocol to investigate the risk of disease progression. Statistical differences between the groups were found for orifice eccentricity, aorta diameter, velocity, jet angle and flow displacement. Key findings of the regression analysis include the association in the proximal ascending aorta between aorta diameter and mean velocity (negative), jet angle (positive) and flow displacement (positive), in the combined cohort. Positive association between flow displacement in the proximal aorta and orifice jet angle in TAV subjects was found. This study represents a pilot application of a protocol for standardized assessment of aortic geometry and hemodynamics associated with BAV disease. Its limited need for user input is advantageous for large cohort studies.


Asunto(s)
Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas , Angiografía por Resonancia Magnética , Modelos Cardiovasculares , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiología , Enfermedad de la Válvula Aórtica Bicúspide , Velocidad del Flujo Sanguíneo , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Radiografía
15.
Ann Biomed Eng ; 42(3): 526-40, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24085344

RESUMEN

A number of clinical, in vitro and computational studies have shown the potential for thromboembolic complications in bileaflet mechanical heart valves (BMHV), primarily due to the complex and unsteady flows in the valve hinges. These studies have focused on quantitative and qualitative parameters such as velocity magnitude, turbulent shear stresses, vortex formation, and platelet activation to identify potential for blood damage. However, experimental characterization of the whole flow fields within the valve hinges has not yet been conducted. This information can be utilized to investigate instantaneous damage to blood elements and also to validate numerical studies focusing on the hinge's complex fluid dynamics. The objective of this study was therefore to develop a high-resolution imaging system to characterize the flow fields and global velocity maps in a BMHV hinge. In this study, the steady leakage hinge flow fields representing the diastolic phase during the cardiac cycle in a 23 mm St. Jude Medical regent BMHV in the aortic position were characterized using a two-dimensional micro particle image velocimetry system. Diastolic flow was simulated by imposing a static pressure head on the aortic side. Under these conditions, a reverse flow jet from the aortic to the ventricular side was observed with velocities in the range of 1.47-3.24 m/s, whereas low flow regions were observed on the ventricular side of the hinge with viscous shear stress magnitude up to 60 N/m². High velocities and viscous shearing may be associated with platelet activation and hemolysis, while low flow zones can cause thrombosis due to increased residence time in the hinge. Overall, this study provides a high spatial resolution experimental technique to map the fluid velocity in the BMHV hinge, which can be extended to investigate micron-scale flow domains in various prosthetic devices under different hemodynamic conditions.


Asunto(s)
Plaquetas , Viscosidad Sanguínea , Diagnóstico por Imagen/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Modelos Cardiovasculares , Activación Plaquetaria , Velocidad del Flujo Sanguíneo , Plaquetas/metabolismo , Plaquetas/patología , Humanos
16.
Ann Biomed Eng ; 42(6): 1195-206, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24719050

RESUMEN

Patients with aortic stenosis present with calcium deposits on the native aortic valve, which can result in non-concentric expansion of Transcatheter Aortic Valve Replacement (TAVR) stents. The objective of this study is to evaluate whether eccentric deployment of TAVRs lead to turbulent blood flow and blood cell damage. Particle Image Velocimetry was used to quantitatively characterize fluid velocity fields, shear stress and turbulent kinetic energy downstream of TAVRs deployed in circular and eccentric orifices representative of deployed TAVRs in vivo. Effective orifice area (EOA) and mean transvalvular pressure gradient (TVG) values did not differ substantially in circular and eccentric deployed valves, with only a minor decrease in EOA observed in the eccentric valve (2.0 cm(2) for circular, 1.9 cm(2) for eccentric). Eccentric deployed TAVR lead to asymmetric systolic jet formation, with increased shear stresses (circular = 97 N/m(2) vs. eccentric = 119 N/m(2)) and regions of turbulence intensity (circular = 180 N/m(2) vs. eccentric = 230 N/m(2)) downstream that was not present in the circular deployed TAVR. The results of this study indicate that eccentric deployment of TAVRs can lead to altered flow characteristics and may potentially increase the hemolytic potential of the valve, which were not captured through hemodynamic evaluation alone.


Asunto(s)
Válvula Aórtica/fisiopatología , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Modelos Cardiovasculares , Flujo Pulsátil , Humanos , Reología
17.
Ann Biomed Eng ; 41(2): 305-15, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22965640

RESUMEN

Numerical models of the mitral valve have been used to elucidate mitral valve function and mechanics. These models have evolved from simple two-dimensional approximations to complex three-dimensional fully coupled fluid structure interaction models. However, to date these models lack direct one-to-one experimental validation. As computational solvers vary considerably, experimental benchmark data are critically important to ensure model accuracy. In this study, a novel left heart simulator was designed specifically for the validation of numerical mitral valve models. Several distinct experimental techniques were collectively performed to resolve mitral valve geometry and hemodynamics. In particular, micro-computed tomography was used to obtain accurate and high-resolution (39 µm voxel) native valvular anatomy, which included the mitral leaflets, chordae tendinae, and papillary muscles. Three-dimensional echocardiography was used to obtain systolic leaflet geometry. Stereoscopic digital particle image velocimetry provided all three components of fluid velocity through the mitral valve, resolved every 25 ms in the cardiac cycle. A strong central filling jet (V ~ 0.6 m/s) was observed during peak systole with minimal out-of-plane velocities. In addition, physiologic hemodynamic boundary conditions were defined and all data were synchronously acquired through a central trigger. Finally, the simulator is a precisely controlled environment, in which flow conditions and geometry can be systematically prescribed and resultant valvular function and hemodynamics assessed. Thus, this work represents the first comprehensive database of high fidelity experimental data, critical for extensive validation of mitral valve fluid structure interaction simulations.


Asunto(s)
Válvula Mitral/fisiología , Modelos Biológicos , Animales , Fenómenos Biomecánicos , Ecocardiografía Tridimensional , Hemodinámica , Reología , Ovinos , Microtomografía por Rayos X
18.
Ann Biomed Eng ; 41(6): 1258-68, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23460042

RESUMEN

Patient-specific models of the heart's mitral valve (MV) exhibit potential for surgical planning. While advances in 3D echocardiography (3DE) have provided adequate resolution to extract MV leaflet geometry, no study has quantitatively assessed the accuracy of their modeled leaflets vs. a ground-truth standard for temporal frames beyond systolic closure or for differing valvular dysfunctions. The accuracy of a 3DE-based segmentation methodology based on J-splines was assessed for porcine MVs with known 4D leaflet coordinates within a pulsatile simulator during closure, peak closure, and opening for a control, prolapsed, and billowing MV model. For all time points, the mean distance error between the segmented models and ground-truth data were 0.40 ± 0.32 mm, 0.52 ± 0.51 mm, and 0.74 ± 0.69 mm for the control, flail, and billowing models. For all models and temporal frames, 95% of the distance errors were below 1.64 mm. When applied to a patient data set, segmentation was able to confirm a regurgitant orifice and post-operative improvements in coaptation. This study provides an experimental platform for assessing the accuracy of an MV segmentation methodology at phases beyond systolic closure and for differing MV dysfunctions. Results demonstrate the accuracy of a MV segmentation methodology for the development of future surgical planning tools.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Animales , Humanos , Modelos Biológicos , Porcinos
19.
Ann Thorac Surg ; 95(2): 621-8, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23141528

RESUMEN

BACKGROUND: Ischemic mitral valve (MV) repair for patients with severe left ventricular dilation remains challenging. The objective of this study was to investigate the efficacy of papillary muscle (PM) relocation to restore physiologic MV function. METHODS: Fresh ovine MVs (n = 6) were studied in a left-heart simulator under physiologic hemodynamics. Ischemic MV disease was simulated by annular dilation and PM displacement. Initial valvular repair was performed with mitral annuloplasty; further PM displacement simulated progressive left ventricular dilation. Basal PM repositioning (Kron procedure), performed to alleviate leaflet tethering, consisted of relocating (1) both PMs toward the commissures; (2) both PMs toward the trigones; (3) the posteromedial PM toward the ipsilateral commissure; and (4) the posteromedial PM toward the ipsilateral trigone. Coaptation length and tenting area were measured using three-dimensional echocardiography as surrogates of MV function. RESULTS: Papillary muscle relocation as an adjunct to mitral annuloplasty statistically improved coaptation length and tenting area compared with the disease condition. No statistical differences in coaptation length and tenting area were observed between final repaired conditions and control conditions. No statistical differences were observed between commissural and trigonal repairs at any incremental repair step. Coaptation length and tenting area were plotted against PM distance; the data were fit to linear regressions. CONCLUSIONS: In a realistic in vitro model of ischemic left ventricular dilation, apical-basal PM relocation, as an adjunct procedure to mitral annuloplasty, restored optimal MV closure. Trigonal or commissural traction suture location did not significantly affect the degree of restored coaptation. Linear relationships between PM positions and leaflet variables were established, which could be used to inform surgical repairs.


Asunto(s)
Válvula Mitral/cirugía , Músculos Papilares/trasplante , Animales , Procedimientos Quirúrgicos Cardíacos/métodos , Válvula Mitral/fisiología , Recuperación de la Función , Ovinos
20.
J Biomech ; 46(14): 2550-3, 2013 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-23948375

RESUMEN

Mitral annuloplasty has been a keystone to the success of mitral valve repair in functional mitral regurgitation. Understanding the complex interplay between annular-ring stresses and left ventricular function has significant implications for patient-ring selection, repair failure, and patient safety. A step towards assessing these challenges is developing a transducer that can be implanted in the exact method as commercially available rings and can quantify multidirectional ring loading. An annuloplasty ring transducer was developed to measure stresses at eight locations on both the in-plane and out-of-plane surfaces of an annuloplasty ring's titanium core. The transducer was implanted in an ovine subject using 10 sutures at near symmetric locations. At implantation, the ring was observed to undersize the mitral annulus. The flaccid annulus exerted both compressive (-) and tensile stresses (+) on the ring ranging from -3.17 to 5.34 MPa. At baseline hemodynamics, stresses cyclically changed and peaked near mid-systole. Mean changes in cyclic stress from ventricular diastole to mid-systole ranged from -0.61 to 0.46 MPa (in-plane direction) and from -0.49 to 1.13 MPa (out-of-plane direction). Results demonstrate the variability in ring stresses that can be introduced during implantation and the cyclic contraction of the mitral annulus. Ring stresses at implantation were approximately 4 magnitudes larger than the cyclic changes in stress throughout the cardiac cycle. These methods will be extended to ring transducers of differing size and geometry. Upon additional investigation, these data will contribute to improved knowledge of annulus-ring stresses, LV function, and the safer development of mitral repair techniques.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral , Animales , Ovinos , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA