Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Arch Otorhinolaryngol ; 280(4): 1565-1579, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36625869

RESUMEN

AIM: This European multicentric study aimed to prove safety and performance of the Bonebridge BCI 602 in children and adults suffering from either conductive hearing loss (CHL), mixed hearing loss (MHL), or single-sided sensorineural deafness (SSD). METHODS: 33 patients (13 adults and 10 children with either CHL or MHL and 10 patients with SSD) in three study groups were included. Patients were their own controls (single-subject repeated measures), comparing the unaided or pre-operative to the 3-month post-operative outcomes. Performance was evaluated by sound field thresholds (SF), word recognition scores (WRS) and/or speech reception thresholds in quiet (SRT) and in noise (SNR). Safety was demonstrated with a device-specific surgical questionnaire, adverse event reporting and stable pure-tone measurements. RESULTS: The Bonebridge BCI 602 significantly improved SF thresholds (+ 25.5 dB CHL/MHL/SSD), speech intelligibility in WRS (+ 68.0% CHL/MHL) and SRT in quiet (- 16.5 dB C/MHL) and in noise (- 3.51 dB SNR SSD). Air conduction (AC) and bone conduction (BC) thresholds remained stable over time. All adverse events were resolved, with none unanticipated. Mean audio processor wearing times in hours [h] per day for the CHL/MHL group were ~ 13 h for adults, ~ 11 h for paediatrics and ~ 6 h for the SSD group. The average surgical length was 57 min for the CHL/MHL group and 42 min for the SSD group. The versatility of the BCI 602 (reduced drilling depth and ability to bend the transition for optimal placement) allows for treatment of normal, pre-operated and malformed anatomies. All audiological endpoints were reached. CONCLUSIONS: The Bonebridge BCI 602 significantly improved hearing thresholds and speech understanding. Since implant placement follows the patient's anatomy instead of the shape of the device and the duration of surgery is shorter than with its predecessor, implantation is easier with the BCI 602. Performance and safety were proven for adults and children as well as for the CHL/MHL and SSD indications 3 months post-operatively.


Asunto(s)
Interfaces Cerebro-Computador , Sordera , Audífonos , Perdida Auditiva Conductiva-Sensorineural Mixta , Pérdida Auditiva Sensorineural , Pérdida Auditiva , Percepción del Habla , Adulto , Humanos , Niño , Conducción Ósea , Audición , Perdida Auditiva Conductiva-Sensorineural Mixta/cirugía , Pérdida Auditiva Conductiva/cirugía , Sordera/cirugía , Pérdida Auditiva/cirugía , Pérdida Auditiva Sensorineural/cirugía , Resultado del Tratamiento , Estudios Multicéntricos como Asunto
2.
Neuroradiology ; 64(5): 1021-1031, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34787698

RESUMEN

PURPOSE: Aging is the most significant determinant for brain iron accumulation in the deep grey matter. Data on brain iron evolution during brain maturation in early childhood are limited. The purpose of this study was to investigate age-related iron deposition in the deep grey matter in children using quantitative susceptibility (QSM) and R2* mapping. METHODS: We evaluated brain MRI scans of 74 children (age 6-154 months, mean 40 months). A multi-echo gradient-echo sequence obtained at 3 Tesla was used for the QSM and R2* calculation. Susceptibility of the pallidum, head of caudate nucleus, and putamen was correlated with age and compared between sexes. RESULTS: Susceptibility changes in all three nuclei correlated with age (correlation coefficients for QSM/R2*: globus pallidus 0.955/0.882, caudate nucleus 0.76/0.65, and putamen 0.643/0.611). During the first 2 years, the R2* values increased more rapidly than the QSM values, indicating a combined effect of iron deposition and myelination, followed by a likely dominating effect of iron deposition. There was no significant gender difference. CONCLUSION: QSM and R2* can monitor myelin maturation processes and iron accumulation in the deep grey nuclei of the brain in early life and may be a promising tool for the detection of deviations of this normal process. Susceptibility in the deep nuclei is almost similar early after birth and increases more quickly in the pallidum. The combined use of QSM and R2* analysis is beneficial.


Asunto(s)
Mapeo Encefálico , Sustancia Gris , Encéfalo , Niño , Preescolar , Sustancia Gris/diagnóstico por imagen , Humanos , Hierro , Imagen por Resonancia Magnética
3.
Eur Arch Otorhinolaryngol ; 274(2): 751-756, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27783138

RESUMEN

The exact pathomechanism of deafening in Meniere's disease (MD) is still unknown; intoxication of hair cells and neural damage from endolymphatic hydrops is discussed. In the literature, there are only a few reports on hearing outcome of MD patients after treatment with cochlear implantation (CI) whereby especially the comparison of MD vs. non-MD patients with CI differs. In this retrospective study, results in speech understanding [Freiburger Einsilber (FES65) and Hochmair-Schulz-Moser test in quiet (HSM) and in noise (HSM + 10 dB)] of 27 implanted MD patients were collected and compared to a matched standard CI cohort. Alternative diagnoses were excluded as far as possible by re-analyzing neuroradiologic imaging. After first fitting, MD patients showed significantly better results in FES and HSM testing compared to controls. At 1-year refitting, this effect could not be seen anymore. To conclude, cochlear implantation is a safe and effective treatment for deafness in MD patients. Results in speech understanding are at least equal compared to general CI recipients. To the best of our knowledge, this retrospective study examined the largest collective of CI users deafened by MD so far.


Asunto(s)
Implantes Cocleares , Sordera/cirugía , Enfermedad de Meniere/complicaciones , Audiometría de Tonos Puros , Estudios de Casos y Controles , Implantación Coclear , Sordera/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Percepción del Habla , Hueso Temporal/diagnóstico por imagen
4.
Eur Arch Otorhinolaryngol ; 273(11): 3641-3646, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27015665

RESUMEN

The objective of the study was to examine the impact of the surgical wound closure technique as protection of the obliterated tympanomastoid cavity on the revision surgery rate after subtotal petrosectomy (SP). This is a retrospective case series conducted in a tertiary care referral center. 199 patients (212 ears) with recurrent chronic otitis media underwent SP followed by tympanomastoid obliteration with abdominal fat at a single tertiary referral center between 2005 and 2015. 124 SP were carried out without (group A), 74 with temporalis muscle flap (group B) and 14 with reinforcing material like polydioxanone foil or bovine pericardium or allogenic fascia lata (group C) for wound closure. The evaluated follow-up was either until the scheduled device implantation or 6 months postoperatively. We assessed the rate of postoperative wound healing disorder with revision surgery according to the surgical technique for closure of the obliterated cleft. Revision surgery due to impaired wound healing was necessary in 16 % of the total cases (group A: 18.5 %, group B: 10.8 %, group C: 21.4 %). Further analysis concerning the dehiscent area in both sites (retroauricular and blind sac of the external auditory canal) was conducted and discussed. There was no significant difference observed in the rate of revision surgery between the three groups. The wound healing process after SP is determined by many factors and cannot be significantly influenced solely by reinforcing tissue like the temporalis muscle flap or supporting materials.


Asunto(s)
Otitis Media/cirugía , Procedimientos Quirúrgicos Otológicos , Técnicas de Cierre de Heridas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Animales , Bovinos , Niño , Enfermedad Crónica , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Herida Quirúrgica , Resultado del Tratamiento , Cicatrización de Heridas , Adulto Joven
5.
Audiol Neurootol ; 20(2): 136-146, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25824716

RESUMEN

OBJECTIVES: The principal aim of this study was to assess the safety and effectiveness of the middle ear implant Vibrant Soundbridge (VSB) in patients with moderate-to-severe sensorineural hearing loss up to a mean (± standard deviation) duration of 11.1 ± 2.1 years (min. = 8.2, max. = 13.9, n = 16) after the intervention. DESIGN: This was a retrospective, single-subject repeated-measurements study over a long-term period. A total of 104 German-speaking adults (for 122 implants) were included in this study (54 male, 50 female). The mean age at implantation was 54.5 years (min. = 19.0, max. = 80.4). Audiological outcome and speech intelligibility were assessed in all VSB patients at different time points in non-overlapping groups. RESULTS: Bone conduction (BC) thresholds were preserved after the implantation and no indication was found of an increase over time of the small air-bone gaps introduced by the implantation. BC and air conduction thresholds worsened similarly in both implanted and non-implanted ears over time. The decrease in audiological benefit provided by the VSB was moderate and the Word Recognition Score in quiet conditions at 65 dB SPL was still largely improved with the VSB in the longest observed group. CONCLUSIONS: These results confirm that the VSB does not affect the integrity of the inner/middle ear and is still beneficial in long-term follow-up.


Asunto(s)
Yunque/cirugía , Prótesis Osicular , Reemplazo Osicular/métodos , Adulto , Anciano , Anciano de 80 o más Años , Audiometría de Tonos Puros , Conducción Ósea , Femenino , Pérdida Auditiva Sensorineural , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Percepción del Habla , Resultado del Tratamiento , Adulto Joven
6.
Laryngoscope ; 134(4): 1854-1860, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37676060

RESUMEN

OBJECTIVES: The aim was to analyze the long-term hearing results after simultaneous microsurgical extirpation via enlarged cochleostomy and cochlear implantation in intracochlear schwannoma as compared with non-tumor single-side deafness patients. METHODS: Microsurgical extirpation via enlarged cochleostomy with simultaneous cochlear implantation was performed in 15 cases of intracochlear schwannoma between 2014 and 2021. Speech recognition tests in German language and impedance performances were collected over 36 months of observation and compared with an internal cohort of 52 age matched non-tumor single-side deafness patients. Retrospective cohort study in a tertiary referral center. RESULTS: The surgery proved feasible and uneventful in all cases. In the case of intracochlear schwannoma, the hearing rehabilitation results were highly satisfactory and comparable to those of the non-tumor single-side deafness cohort. The speech recognition performance improved steadily in the first 12 months; afterward, it remained stable, providing indirect evidence against tumor recurrence during the follow-up. One patient required implant revision surgery related to device failure, but no recurrence was registered in the 36 months of observation. CONCLUSIONS: Cochlear implantation is the strategy of choice for hearing rehabilitation in case of intracochlear schwannomas in the long term. In particular, the combination of tumor extirpation via cochleostomy with a cochlear implantation in the same surgical time offers a viable therapy for intracochlear schwannoma, granting a sufficient degree of radicality without compromising the cochlear integrity. This technique allows for revision surgery if required. LEVEL OF EVIDENCE: 4 Laryngoscope, 134:1854-1860, 2024.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Neurilemoma , Neuroma Acústico , Humanos , Implantación Coclear/métodos , Sordera/cirugía , Audición , Recurrencia Local de Neoplasia/cirugía , Neurilemoma/cirugía , Neuroma Acústico/complicaciones , Neuroma Acústico/cirugía , Neuroma Acústico/patología , Estudios Retrospectivos
7.
Trends Hear ; 28: 23312165241248973, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38717441

RESUMEN

To preserve residual hearing during cochlear implant (CI) surgery it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring). A promising method is electrocochleography (ECochG). Within this project the relations between intracochlear ECochG recordings, position of the recording contact in the cochlea with respect to anatomy and frequency and preservation of residual hearing were investigated. The aim was to better understand the changes in ECochG signals and whether these are due to the electrode position in the cochlea or to trauma generated during insertion. During and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed using the CI electrode (MED-EL). During insertion, the recordings were performed at discrete insertion steps on electrode contact 1. After insertion as well as postoperatively the recordings were performed at different electrode contacts. The electrode location in the cochlea during insertion was estimated by mathematical models using preoperative clinical imaging, the postoperative location was measured using postoperative clinical imaging. The recordings were analyzed from six adult CI recipients. In the four patients with good residual hearing in the low frequencies the signal amplitude rose with largest amplitudes being recorded closest to the generators of the stimulation frequency, while in both cases with severe pantonal hearing losses the amplitude initially rose and then dropped. This might be due to various reasons as discussed in the following. Our results indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.


Asunto(s)
Audiometría de Respuesta Evocada , Cóclea , Implantación Coclear , Implantes Cocleares , Humanos , Cóclea/cirugía , Cóclea/fisiología , Cóclea/fisiopatología , Implantación Coclear/instrumentación , Implantación Coclear/métodos , Audiometría de Respuesta Evocada/métodos , Persona de Mediana Edad , Anciano , Masculino , Femenino , Audición/fisiología , Adulto , Resultado del Tratamiento , Valor Predictivo de las Pruebas , Estimulación Eléctrica , Personas con Deficiencia Auditiva/rehabilitación , Personas con Deficiencia Auditiva/psicología , Umbral Auditivo/fisiología
8.
Cancers (Basel) ; 16(13)2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-39001523

RESUMEN

Background: After two decades from its introduction in the lateral skull base paraganglioma surgery, the indications and results of preoperative internal carotid artery stenting should be critically assessed. Materials and Methods: Monocentric retrospective study on 26 patients affected by head and neck paragangliomas (19 tympanojugular paragangliomas, 4 carotid body paragangliomas, 3 vagal paragangliomas) preoperatively treated with internal carotid artery stents between 2008 and 2023. The preoperative findings, the intraoperative complications and the final surgical results were analyzed. Results: The stent complication rate was less than 3.1%. Self-expanding highly flexible intracranial nitinol stents were applied. In all cases, it was possible to completely mobilize the internal carotid artery and perform a vascular dissection of the tumor. Gross total tumor resection was possible in 85% of cases. The median follow up was 7.83 y (SD +/- 3.93 y). No local recurrence was observed. Conclusions: The preoperative vascular stent facilitates tumor dissection from the internal carotid artery without risk of vascular damage, helping the surgeon to achieve surgical radicality. The vascular stent is indicated in the case of revision surgeries, circumferential involvement of the vessel and in cases with non-insufficient intracerebral crossflow. Procedural complications, temporary antiplatelet therapy and delay of surgery are the limitations of the procedure.

9.
Front Neurol ; 15: 1400455, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38711559

RESUMEN

Purpose: The significance of atraumatic electrode array (EA) insertion in cochlear implant (CI) surgery is widely acknowledged, with consensus that forces due to EA insertion are directly correlated with insertion trauma. Unfortunately, the manual perception of these forces through haptic feedback is inherently limited, and techniques for in vivo force measurements to monitor the insertion are not yet available. Addressing this gap, we developed of a force-sensitive insertion tool capable of capturing real-time insertion forces during standard CI surgery. Methods: This paper describes the tool and its pioneering application in a clinical setting and reports initial findings from an ongoing clinical study. Data and experiences from five patients have been evaluated so far, including force profiles of four patients. Results: The initial intraoperative experiences are promising, with successful integration into the conventional workflow. Feasibility of in vivo insertion force measurement and practicability of the tool's intraoperative use could be demonstrated. The recorded in vivo insertion forces show the expected rise with increasing insertion depth. Forces at the end of insertion range from 17.2 mN to 43.6 mN, while maximal peak forces were observed in the range from 44.8 mN to 102.4 mN. Conclusion: We hypothesize that this novel method holds the potential to assist surgeons in monitoring the insertion forces and, thus, minimizing insertion trauma and ensuring better preservation of residual hearing. Future data recording with this tool can form the basis of ongoing research into the causes of insertion trauma, paving the way for new and improved prevention strategies.

10.
Otol Neurotol ; 45(8): 887-894, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39052893

RESUMEN

OBJECTIVE: To prospectively evaluate the association between hearing preservation after cochlear implantation (CI) and intracochlear electrocochleography (ECochG) amplitude parameters. STUDY DESIGN: Multi-institutional, prospective randomized clinical trial. SETTING: Ten high-volume, tertiary care CI centers. PATIENTS: Adults (n = 87) with sensorineural hearing loss meeting CI criteria (2018-2021) with audiometric thresholds of ≤80 dB HL at 500 Hz. METHODS: Participants were randomized to CI surgery with or without audible ECochG monitoring. Electrode arrays were inserted to the full-depth marker. Hearing preservation was determined by comparing pre-CI, unaided low-frequency (125-, 250-, and 500-Hz) pure-tone average (LF-PTA) to LF-PTA at CI activation. Three ECochG amplitude parameters were analyzed: 1) insertion track patterns, 2) magnitude of ECochG amplitude change, and 3) total number of ECochG amplitude drops. RESULTS: The Type CC insertion track pattern, representing corrected drops in ECochG amplitude, was seen in 76% of cases with ECochG "on," compared with 24% of cases with ECochG "off" ( p = 0.003). The magnitude of ECochG signal drop was significantly correlated with the amount of LF-PTA change pre-CI and post-CI ( p < 0.05). The mean number of amplitude drops during electrode insertion was significantly correlated with change in LF-PTA at activation and 3 months post-CI ( p ≤ 0.01). CONCLUSIONS: ECochG amplitude parameters during CI surgery have important prognostic utility. Higher incidence of Type CC in ECochG "on" suggests that monitoring may be useful for surgeons in order to recover the ECochG signal and preventing potentially traumatic electrode-cochlear interactions.


Asunto(s)
Audiometría de Respuesta Evocada , Implantación Coclear , Pérdida Auditiva Sensorineural , Humanos , Audiometría de Respuesta Evocada/métodos , Implantación Coclear/métodos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Pérdida Auditiva Sensorineural/cirugía , Pérdida Auditiva Sensorineural/fisiopatología , Estudios Prospectivos , Implantes Cocleares , Cóclea/cirugía , Cóclea/fisiopatología , Adulto , Audición/fisiología , Audiometría de Tonos Puros
11.
Front Neurosci ; 17: 1202429, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37564369

RESUMEN

Introduction: In a previous study, an inner ear catheter was used to deliver low- and high-dose steroids into the cochlea prior to cochlear implant electrode insertion. With this approach, more apical regions of the cochlea could be reached and a reduction of electrode impedances in the short term was achieved in cochlear implant recipients. Whether intracochlear application of drugs via the catheter is a safe method also for patients with residual hearing has not been investigated hitherto. The aim of the present study was therefore to investigate the effect of intracochlear triamcinolone application in cochlear implant recipients with residual hearing. Patients and methods: Patients with residual hearing were administered triamcinolone-acetonide (4 mg/ml; n = 10) via an inner ear catheter just prior to insertion of a MED-EL FLEX28 electrode. Impedances were measured at defined time points (intra-operatively, post-operatively and at first fitting) and retrospectively compared with a control group (no steroid application) and low- and high-dose group. Hearing thresholds were measured preoperatively, 3 days after surgery and at first fitting by pure tone audiometry. Pre- to postoperative hearing loss was determined at first fitting and compared to results from a previous study. Results: The median hearing loss after implantation (125-1,500 Hz) was 20.6 dB. Four patients (40%) showed a median hearing loss of less than 15 dB, three patients (30%) between 15 and 30 dB and three patients (30%) more than 30 dB. The median hearing loss was similar to the results obtained from our previous study showing a median hearing loss of 24 dB when using FLEX28 electrode arrays. Conclusion: No difference in residual hearing loss was found when comparing application of triamcinolone-acetonide using an inner ear catheter prior to the insertion of a FLEX28 electrode array to the use of the FLEX28 electrode array without the catheter. Thus, we conclude that application of drugs to the cochlea with an inner ear catheter could be a feasible approach in patients with residual hearing.

12.
Int J Comput Assist Radiol Surg ; 18(11): 2117-2124, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37310560

RESUMEN

PURPOSE: Trauma that may be inflicted to the inner ear (cochlea) during the insertion of an electrode array (EA) in cochlear implant (CI) surgery can significantly decrease the hearing outcome of patients with residual hearing. Interaction forces between the EA and the cochlea are a promising indicator for the likelihood of intracochlear trauma. However, insertion forces have only been measured in laboratory setups. We recently developed a tool to measure the insertion force during CI surgery. Here, we present the first ex vivo evaluation of our tool with a focus on usability in the standard surgical workflow. METHODS: Two CI surgeons inserted commercially available EAs into three temporal bone specimens. The insertion force and the orientation of the tool were recorded together with camera footage. The surgeons answered a questionnaire after each insertion to evaluate the surgical workflow with respect to CI surgery. RESULTS: The EA insertion using our tool was rated successful in all 18 trials. The surgical workflow was evaluated to be equivalent to standard CI surgery. Minor handling challenges can be overcome through surgeon training. The peak insertion forces were 62.4 mN ± 26.7 mN on average. Peak forces significantly correlated to the final electrode insertion depth, supporting the assumption that the measured forces mainly correspond to intracochlear events and not extracochlear friction. Gravity-induced forces of up to 28.8 mN were removed from the signal, illustrating the importance of the compensation of such forces in manual surgery. CONCLUSION: The results show that the tool is ready for intraoperative use. In vivo insertion force data will improve the interpretability of experimental results in laboratory settings. The implementation of live insertion force feedback to surgeons could further improve residual hearing preservation.

13.
Hear Res ; 433: 108765, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37094529

RESUMEN

OBJECTIVES: Test feasibility of a means to distinguish artifact from relevant signal in an experimental method for pre-clinical assessment of bone conduction (BC) stimulation efficiency based on measurement of intracochlear pressure (ICP). METHODS: Experiments were performed on fresh-frozen human temporal bones and cadaver heads. In a first step, fiber optic pressure sensors inserted into the cochlea through cochleostomies were intentionally vibrated to generate relative motion versus the stationary specimen, and the resulting ICP artifact recorded, before and after attaching the sensor fiber to the bone with glue. In a second step, BC stimulation was applied in the conventional location for a commercial bone anchored implant, as well as two alternative locations closer to the otic capsule. Again, ICP was recorded and compared with an estimated artifact, calculated from the previous measurements with intentional vibration of the fiber. RESULTS: Intentional vibration of the sensor fiber creates relative motion between fiber and bone, as intended, and causes an ICP signal. The stimulus does not create substantial promontory vibration, indicating that the measured ICP is all artifact, i.e. would not occur if the sensor were not in place. Fixating the sensor fiber to the bone with glue reduces the ICP artifact by at least 20 dB. BC stimulation also creates relative motion between sensor fiber and bone, as expected, from which an estimated ICP artifact level can be calculated. The ICP signal measured during BC stimulation is well above the estimated artifact, at least in some specimens and at some frequencies, indicating "real" cochlear stimulation, which would result in an auditory percept in a live subject. Stimulation at the alternative locations closer to the otic capsule appear to result in higher ICP (no statistical analysis performed), indicating a trend towards more efficient stimulation than at the conventional location. CONCLUSIONS: Intentional vibration of the fiber optic sensor for measurement of ICP can be used to derive an estimate of the artifact to be expected when measuring ICP during BC stimulation, and to characterize the effectiveness of glues or other means of reducing the artifact caused by relative motion of fiber and bone.


Asunto(s)
Artefactos , Vibración , Humanos , Estimulación Acústica/métodos , Cóclea/fisiología , Conducción Ósea/fisiología , Cadáver
14.
PLoS One ; 17(4): e0266077, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35452461

RESUMEN

Access to low-frequency acoustic information in cochlear implant patients leads to better speech understanding in noise. Electrocochleography (ECochG) can provide real-time feedback about the health of the cochlea during the insertion process with the potential to reduce insertion trauma. We describe our experiences of using this technique. Data from 47 adult subjects with measurable residual hearing and an Advanced Bionics (Valencia, CA) SlimJ (46) or MidScala (1) electrode array were analyzed. ECochGs were recorded intraoperatively via the implant. The surgeon adjusted the course of the electrode insertion based on drops in the ECochG. The final array position was assessed using postoperative imaging and pure tone thresholds were measured before and after surgery. Three different patterns of ECochG response amplitude were observed: Growth, Fluctuating and Total Loss. Subjects in the growth group showed the smallest postoperative hearing loss. However, the group with fluctuating amplitudes showed no meaningful correlation between the ECochG responses and the postoperative hearing loss, indicating that amplitude alone is insufficient for detecting damage. Considering the phase of the signal additionally to the amplitude and reclassifying the data by both the phase and amplitude of the response into three groups Type I-Type III produced statistically significant correlations between postoperative hearing loss and the grouping based on amplitude and phase respectively. We showed significantly better hearing preservation for Type I (no drop in amplitude) and Type II (drop with a concurrent phase shift), while Type III (drop without concurrent phase shift) had more surgery induced hearing loss. ECochG potentials measured through the implant could provide valuable feedback during the electrode insertion. Both the amplitude and phase of the ECochG response are important to consider. More data needs to be evaluated to better understand the impact of the different signal components to design an automated system to alert the surgeon ahead of damaging the cochlea.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Pérdida Auditiva , Adulto , Audiometría de Respuesta Evocada/métodos , Cóclea/cirugía , Implantación Coclear/métodos , Sordera/cirugía , Audición , Pérdida Auditiva/cirugía , Humanos
15.
Front Neurol ; 13: 829478, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35547379

RESUMEN

A minimally-invasive surgical (MIS) approach to cochlear implantation, if safe, practical, simple in surgical handling, and also affordable has the potential to replace the conventional surgical approaches. Our MIS approach uses patient-specific drilling templates (positioning jigs). While the most popular MIS approaches use robots, the robotic aspect is literally put aside, because our high-precision parallel kinematics is only used to individualize a positioning jig. This jig can then be mounted onto a bone-anchored mini-stereotactic frame at the patient's skull and used to create a drill-hole through the temporal bone to the patient's cochlea. We present the first clinical experience where we use sham drill bits of different diameters instead of drilling into the bone in order to demonstrate the feasibility and accuracy.

16.
Sci Rep ; 12(1): 5047, 2022 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-35322066

RESUMEN

Cochlear variability is of key importance for the clinical use of cochlear implants, the most successful neuroprosthetic device that is surgically placed into the cochlear scala tympani. Despite extensive literature on human cochlear variability, few information is available on the variability of the modiolar wall. In the present study, we analyzed 108 corrosion casts, 95 clinical cone beam computer tomographies (CTs) and 15 µCTs of human cochleae and observed modiolar variability of similar and larger extent than the lateral wall variability. Lateral wall measures correlated with modiolar wall measures significantly. ~ 49% of the variability had a common cause. Based on these data we developed a model of the modiolar wall variations and related the model to the design of cochlear implants aimed for perimodiolar locations. The data demonstrate that both the insertion limits relevant for lateral wall damage (approximate range of 4-9 mm) as well as the dimensions required for optimal perimodiolar placement of the electrode (the point of release from the straightener; approximate range of 2-5mm) are highly interindividually variable. The data demonstrate that tip fold-overs of preformed implants likely result from the morphology of the modiolus (with radius changing from base to apex), and that optimal cochlear implantation of perimodiolar arrays cannot be guaranteed without an individualized surgical technique.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Cóclea/anatomía & histología , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Implantación Coclear/métodos , Tomografía Computarizada de Haz Cónico , Electrodos Implantados , Humanos , Rampa Timpánica/cirugía
17.
Hear Res ; 421: 108369, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34728110

RESUMEN

OBJECTIVES: The output performance of a novel semi-implantable transcutaneous bone conduction device was compared to an established percutaneous bone-anchored hearing system device using cadaver heads. The influence of actuator position, tissue growth below the actuator and mounting it on the surface or in a flattened bone bed on the performance of the implanted actuator was investigated. MATERIALS AND METHODS: The percutaneous and the new transcutaneous device were sequentially implanted at two sites in five human cadaver heads: 55 mm superior-posterior to the ear canal opening (position A) and, closer to the cochlea, about 20 mm inferior-posterior to the ear canal opening behind the pinna on the mastoid (position B). The ipsi- and contralateral cochlear promontory (CP) velocity magnitude responses to percutaneous and transcutaneous stimulation were measured using laser Doppler vibrometry. In addition, the CP vibration of the transcutaneous device placed directly on the skull bone surface was compared with the placement in a flattened bone bed at a depth of about 3 mm. Finally, the influence of placing a thin silicone interposition layer under the implanted transducer was also explored. RESULTS: The percutaneous device provided about an 11 dB higher average CP vibration level than the transcutaneous device at frequencies between 0.5 and 10 kHz. The ipsilateral CP vibration responses with stimulations at position B were on average 13 dB higher compared to stimulation at position A. The placement of the transcutaneous transducer at position B provided similar or higher average vibration magnitudes than the percutaneous transducer at position A. The 3 mm deep flattened bone bed had no significant effects on the output performance. Placing a thin silicone layer under the transcutaneous transducer had no significant influence on the output of the transcutaneous device. CONCLUSIONS: Our results using the CP vibration responses show that at frequencies above 500 Hz the new transcutaneous device at position B provides similar output levels as the percutaneous device at position A. The results also indicated that neither a bone bed for the placement of the transcutaneous transducer nor a simulated tissue growth between the actuator and the bone affect the output performance of the device.


Asunto(s)
Conducción Ósea , Audífonos , Conducción Ósea/fisiología , Cadáver , Cóclea/fisiología , Humanos , Siliconas , Vibración
18.
J Clin Med ; 11(20)2022 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-36294411

RESUMEN

Anatomical malformations, obliterations of the cochlea, or re-implantations pose particular challenges in cochlear implantation. Treatment methods rely on radiological and intraoperative findings and include incomplete insertion, the implantation of a double array, and radical cochleostomy. In addition, a stiff electrode array, e.g., the IE stiff (IES) custom-made device (CMD, MED-EL), was prescribed individually for those special cases and pre-inserted prior to facilitate cochlear implantation in challenging cases. Data on outcomes after implantation in obliterated cochleae are usually based on individual case reports since standardised procedures are lacking. A retrospective analysis was conducted to analyse our cases on obliterated cochleae treated with MED-EL devices in order to allow the different cases to be compared. Impedances and speech perception data of patients treated with the IES CMD and the double array were retrospectively compared to patients treated with a STANDARD or FLEX electrode array (the REGULAR group). Patients with a Split-Array CMD had a poor speech perception when compared to patients treated with the IES CMD device. Thus, the IES CMD can successfully be used in patients with obliterated cochleae who would otherwise be non-users, candidates for a Split-Array CMD, or candidates for partial insertion with insufficient cochlear coverage.

19.
Otol Neurotol ; 43(7): 789-796, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35861647

RESUMEN

OBJECTIVES: To evaluate the utility of intracochlear electrocochleography (ECochG) monitoring during cochlear implant (CI) surgery on postoperative hearing preservation. STUDY DESIGN: Prospective, randomized clinical trial. SETTING: Ten high-volume, tertiary care CI centers. PATIENTS: Adult patients with sensorineural hearing loss meeting the CI criteria who selected an Advanced Bionics CI. METHODS: Patients were randomized to CI surgery either with audible ECochG monitoring available to the surgeon during electrode insertion or without ECochG monitoring. Hearing preservation was determined by comparing preoperative unaided low-frequency (125-, 250-, and 500-Hz) pure-tone average (LF-PTA) to postoperative LF-PTA at CI activation. Pre- and post-CI computed tomography was used to determine electrode scalar location and electrode translocation. RESULTS: Eighty-five adult CI candidates were enrolled. The mean (standard deviation [SD]) unaided preoperative LF-PTA across the sample was 54 (17) dB HL. For the whole sample, hearing preservation was "good" (i.e., LF-PTA change 0-15 dB) in 34.5%, "fair" (i.e., LF-PTA change >15-29 dB) in 22.5%, and "poor" (i.e., LF-PTA change ≥30 dB) in 43%. For patients randomized to ECochG "on," mean (SD) LF-PTA change was 27 (20) dB compared with 27 (23) dB for patients randomized to ECochG "off" ( p = 0.89). Seven percent of patients, all of whom were randomized to ECochG off, showed electrode translocation from the scala tympani into the scala vestibuli. CONCLUSIONS: Although intracochlear ECochG during CI surgery has important prognostic utility, our data did not show significantly better hearing preservation in patients randomized to ECochG "on" compared with ECochG "off."


Asunto(s)
Implantación Coclear , Implantes Cocleares , Adulto , Audiometría de Respuesta Evocada/métodos , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Implantación Coclear/métodos , Implantes Cocleares/efectos adversos , Audición , Humanos , Estudios Prospectivos
20.
Otol Neurotol ; 42(2): 242-250, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33026778

RESUMEN

OBJECTIVE: Cochlear implants are the gold standard for patients with severe sensorineural hearing loss. A focused electrical stimulation of individual spiral ganglion neurons has not been achieved yet because the scala tympani is a fluid-filled compartment and does not offer a matrix for neuritic outgrowth. Coating of the electrode contacts with swelling hydrogels could fill that gap between the electrode array and the medial wall of the cochlea. Therefore, the exact position of the electrode array within the scala tympani has to be known. STUDY DESIGN: Retrospective analysis of patient data sets. SETTING: Tertiary referral center. A total of 95 patients with cochlear implants from one manufacturer were included in this study. The lateral wall, the modiolar wall, and the cochlear implant electrode were segmented using OsiriX MD. For repositioning and reconstructing the respective contours and measuring distances, files were analyzed in MATLAB. The distances from the edge of each electrode contact to the cochlear walls showed no significant differences. But between the different contacts within each patient, there were significant differences. Around 180 degree insertion, electrodes start to get in contact with the lateral wall. The tip of the electrode array was always facing toward the modiolar wall independent of the length of the electrode. We established a method to analyze the position of electrodes within the cochlea.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Cóclea/cirugía , Electrodos , Electrodos Implantados , Humanos , Estudios Retrospectivos , Rampa Timpánica/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA