Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
N Engl J Med ; 387(10): 869-881, 2022 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-36069869

RESUMEN

BACKGROUND: Open-source automated insulin delivery (AID) systems are used by many patients with type 1 diabetes. Data are needed on the efficacy and safety of an open-source AID system. METHODS: In this multicenter, open-label, randomized, controlled trial, we assigned patients with type 1 diabetes in a 1:1 ratio to use an open-source AID system or a sensor-augmented insulin pump (control). The patients included both children (defined as 7 to 15 years of age) and adults (defined as 16 to 70 years of age). The AID system was a modified version of AndroidAPS 2.8 (with a standard OpenAPS 0.7.0 algorithm) paired with a preproduction DANA-i insulin pump and Dexcom G6 CGM, which has an Android smartphone application as the user interface. The primary outcome was the percentage of time in the target glucose range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter) between days 155 and 168 (the final 2 weeks of the trial). RESULTS: A total of 97 patients (48 children and 49 adults) underwent randomization (44 to open-source AID and 53 to the control group). At 24 weeks, the mean (±SD) time in the target range increased from 61.2±12.3% to 71.2±12.1% in the AID group and decreased from 57.7±14.3% to 54.5±16.0% in the control group (adjusted difference, 14 percentage points; 95% confidence interval, 9.2 to 18.8; P<0.001), with no treatment effect according to age (P = 0.56). Patients in the AID group spent 3 hours 21 minutes more in the target range per day than those in the control group. No severe hypoglycemia or diabetic ketoacidosis occurred in either group. Two patients in the AID group withdrew from the trial owing to connectivity issues. CONCLUSIONS: In children and adults with type 1 diabetes, the use of an open-source AID system resulted in a significantly higher percentage of time in the target glucose range than the use of a sensor-augmented insulin pump at 24 weeks. (Supported by the Health Research Council of New Zealand; Australian New Zealand Clinical Trials Registry number, ACTRN12620000034932.).


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Bombas de Infusión , Insulina , Adolescente , Adulto , Anciano , Australia , Glucemia/análisis , Niño , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Persona de Mediana Edad , Adulto Joven
2.
Diabetes Technol Ther ; 26(1): 40-48, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37823890

RESUMEN

Objective: To investigate 12-month glycemic and psychosocial changes following transition from multiple daily injections (MDI) to advanced hybrid closed-loop (AHCL) therapy in youth (aged 13-25 years) with type 1 diabetes and suboptimal glycemia (glycated hemoglobin [HbA1c] ≥8.5% [69 mmol/mol]). Research Design and Methods: Prospective, single arm, dual-center study in 20 participants. Extension phase outcomes reported after 12 months, including HbA1c, time in glycemic ranges, AHCL system performance, and psychosocial questionnaires assessing quality of life, diabetes treatment, and sleep. Results: After 12 months, 19 out of 20 participants continued to use AHCL. Average time-in-range 70-180 mg/dL (3.9-10.0 mmol/L) improved from 27.6% ± 13.2% to 62.5% ± 11.4%. This translated to an average 2.5 percentage-point (27.1 mmol/mol) improvement in HbA1c from 10.5% ± 2.1% (91.2 mmol/mol) at baseline to 8.0% ± 0.9% (64.1 mmol/mol) at 12 months. Psychosocial questionnaires and very high HbA1c at study entry indicated significant diabetes-associated burden for both individuals and parents. After 12 months, improvements were observed in general and diabetes-specific health-related quality of life, as well as in diabetes treatment satisfaction. Safety data were reassuring with a diabetic ketoacidosis rate of 0.15 per participant-year after 12 months of AHCL (compared to 0.25 per participant-year in the 12 months before the study). Conclusions: After 12 months of AHCL usage, this study highlights the potential for substantial and sustained glycemic and psychosocial improvements among individuals experiencing considerable diabetes burden and suboptimal glycemia, following their switch from MDI to AHCL.


Asunto(s)
Diabetes Mellitus Tipo 1 , Humanos , Adolescente , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Hipoglucemiantes/uso terapéutico , Glucosa , Insulina/uso terapéutico , Calidad de Vida , Estudios Prospectivos , Resultado del Tratamiento , Sistemas de Infusión de Insulina , Automonitorización de la Glucosa Sanguínea , Glucemia
3.
Diabetes Care ; 46(3): 628-632, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36689621

RESUMEN

OBJECTIVE: To evaluate glycemic outcomes in youth (aged 13-25 years) with type 1 diabetes and high-risk glycemic control (HbA1c ≥8.5% [69 mmol/mol]) on multiple daily injection (MDI) therapy after transitioning to advanced hybrid closed loop (AHCL) therapy. RESEARCH DESIGN AND METHODS: This prospective, 3-month, single-arm, dual-center study enrolled 20 participants, and all completed the study. RESULTS: HbA1c decreased from 10.5 ± 2.1% (91.2 ± 22.8 mmol/mol) at baseline to 7.6 ± 1.1% (59.7 ± 11.9 mmol/mol), and time spent in target range 70-180 mg/dL (3.9-10.0 mmol/L) increased from 27.6 ± 13.2% at baseline to 66.5 ± 9.8% after 3 months of AHCL. Two episodes of diabetic ketoacidosis attributed to infusion set failure occurred. CONCLUSIONS: AHCL has the potential to improve suboptimal glycemia in youth with type 1 diabetes previously on MDI therapy.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adolescente , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Estudios Prospectivos , Adulto Joven , Adulto
4.
Diabetes Technol Ther ; 25(4): 250-259, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36763345

RESUMEN

Aim: To assess long-term efficacy and safety of open-source automated insulin delivery (AID) in children and adults (7-70 years) with type 1 diabetes. Methods: Both arms of a 24-week randomized controlled trial comparing open-source AID (OpenAPS algorithm within a modified version of AndroidAPS, preproduction DANA-i™ insulin pump, Dexcom G6 continuous glucose monitor) with sensor-augmented pump therapy (SAPT), entered a 24-week continuation phase where the SAPT arm (termed SAPT-AID) crossed over to join the open-source AID arm (termed AID-AID). Most participants (69/94) used a preproduction YpsoPump® insulin pump during the continuation phase. Analyses incorporated all 52 weeks of data, and combined between-group and within-subject differences to calculate an overall "treatment effect" of AID versus SAPT. Results: Mean time in range (TIR; 3.9-10 mmol/L [70-180 mg/dL]) was 12.2% higher with AID than SAPT (95% confidence interval [CI] 10.4 to 14.1; P < 0.001). TIR was 56.9% (95% CI 54.2 to 59.6) with SAPT and 69.1% (95% CI 67.1 to 71.1) with AID. The treatment effect did not differ by age (P = 0.39) or insulin pump type (P = 0.37). HbA1c was 5.1 mmol/mol lower [0.5%] with AID (95% CI -6.6 to -3.6; P < 0.001). There were no episodes of diabetic ketoacidosis or severe hypoglycemia with either treatment over the 48 weeks. Six participants (all in SAPT-AID) withdrew: three with hardware issues, two preferred SAPT, and one with infusion-site skin irritation. Conclusion: Further evaluation of the community derived automated insulin delivery (CREATE) trial to 48 weeks confirms that open-source AID is efficacious and safe with different insulin pumps, and demonstrates sustained glycemic improvements without additional safety concerns.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Adulto , Humanos , Niño , Insulina/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Hipoglucemia/inducido químicamente , Glucemia , Insulina Regular Humana/uso terapéutico , Sistemas de Infusión de Insulina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA