Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Digit Imaging ; 36(3): 1049-1059, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36854923

RESUMEN

Deep learning (DL) has been proposed to automate image segmentation and provide accuracy, consistency, and efficiency. Accurate segmentation of lipomatous tumors (LTs) is critical for correct tumor radiomics analysis and localization. The major challenge of this task is data heterogeneity, including tumor morphological characteristics and multicenter scanning protocols. To mitigate the issue, we aimed to develop a DL-based Super Learner (SL) ensemble framework with different data correction and normalization methods. Pathologically proven LTs on pre-operative T1-weighted/proton-density MR images of 185 patients were manually segmented. The LTs were categorized by tumor locations as distal upper limb (DUL), distal lower limb (DLL), proximal upper limb (PUL), proximal lower limb (PLL), or Trunk (T) and grouped by 80%/9%/11% for training, validation and testing. Six configurations of correction/normalization were applied to data for fivefold-cross-validation trainings, resulting in 30 base learners (BLs). A SL was obtained from the BLs by optimizing SL weights. The performance was evaluated by dice-similarity-coefficient (DSC), sensitivity, specificity, and Hausdorff distance (HD95). For predictions of the BLs, the average DSC, sensitivity, and specificity from the testing data were 0.72 [Formula: see text] 0.16, 0.73 [Formula: see text] 0.168, and 0.99 [Formula: see text] 0.012, respectively, while for SL predictions were 0.80 [Formula: see text] 0.184, 0.78 [Formula: see text] 0.193, and 1.00 [Formula: see text] 0.010. The average HD95 of the BLs were 11.5 (DUL), 23.2 (DLL), 25.9 (PUL), 32.1 (PLL), and 47.9 (T) mm, whereas of SL were 1.7, 8.4, 15.9, 2.2, and 36.6 mm, respectively. The proposed method could improve the segmentation accuracy and mitigate the performance instability and data heterogeneity aiding the differential diagnosis of LTs in real clinical situations.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Inteligencia Artificial
2.
Skeletal Radiol ; 49(10): 1505-1523, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32447469

RESUMEN

The shoulder enjoys the widest range of motion of all the joints in the human body, therefore requires a delicate balance between stability and motility. The glenohumeral joint is inclined to fall into two main instability categories: macro and micro. Macroinstability can be traumatic or atraumatic, with anterior or posterior dislocation of the humeral head. Microinstability falls within the broader section of acquired instability in overstressed shoulder caused by repeated joint stress. Anterior traumatic instability is the most frequent entity and a relatively common injury in young and athletic population. While shoulder instability is a clinical diagnosis, imaging impacts the patient management by detailing the extent of injury, such as capsulo-labral-ligamentous tears, fracture, and/or dislocation, describing the predisposing anatomic conditions and guide the therapetic choice. The aim of this comprehensive review is to cover the imaging findings of shoulder instability by different imaging techniques.


Asunto(s)
Inestabilidad de la Articulación , Luxación del Hombro , Articulación del Hombro , Artrografía , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Imagen por Resonancia Magnética , Hombro , Luxación del Hombro/diagnóstico por imagen , Articulación del Hombro/diagnóstico por imagen
3.
Skeletal Radiol ; 49(6): 1005-1014, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31965239

RESUMEN

OBJECTIVES: The objectives of the study are (1) to distinguish lipoma (L) from atypical lipomatous tumor (ALT) using MRI qualitative features, (2) to assess the value of contrast enhancement, and (3) to evaluate the reproducibility and confidence level of radiological readings. MATERIALS AND METHODS: Patients with pathologically proven L or ALT, who underwent MRI within 3 months from surgical excision were included in this retrospective multicenter international study. Two radiologists independently reviewed MRI centrally. Impressions were recorded as L or ALT. A third radiologist was consulted for discordant readings. The two radiologists re-read all non-contrast sequences; impression was recorded; then post-contrast images were reviewed and any changes were recorded. RESULTS: A total of 246 patients (135 females; median age, 59 years) were included. ALT was histopathologically confirmed in 70/246 patients. In multivariable analysis, in addition to the lesion size, deep location, proximal lower limb lesions, demonstrating incomplete fat suppression, or increased architectural complexity were the independent predictive features of ALT; but not the contrast enhancement. Post-contrast MRI changed the impression in a total of 5 studies (3 for R1 and 4 for R2; 2 studies are common); all of them were incorrectly changed from Ls to ALTs. Overall, inter-reader kappa agreement was 0.42 (95% CI 0.39-0.56). Discordance between the two readers was statistically significant for both pathologically proven L (p < 0.001) and ALT (p = 0.003). CONCLUSION: Most qualitative MR imaging features can help distinguish ALTs from BLs. However, contrast enhancement may be limited and occasionally misleading. Substantial discordance on MRI readings exists between radiologists with a relatively high false positive and negative rates.


Asunto(s)
Lipoma/diagnóstico por imagen , Liposarcoma/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Medios de Contraste , Femenino , Humanos , Lipoma/patología , Liposarcoma/patología , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
4.
JBJS Case Connect ; 9(2): e0284, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31233429

RESUMEN

CASE: A 33-year-old woman presented with a six-month history of spontaneous radial nerve palsy and no identified lesion on imaging. She underwent operative exploration where an hourglass deformity was seen and resected. Pathology returned as a rare tumor, a myofibroma. The patient regained full radial nerve function. CONCLUSIONS: A trial of observation is often indicated in the cases of isolated nerve palsy where anatomic lesions have been eliminated. This case highlights that imaging studies can miss a tumor involving nerve and that painless, spontaneous nerve palsy may be a time where early surgical intervention offers a better chance of recovery.


Asunto(s)
Miofibroma/complicaciones , Miofibroma/cirugía , Nervio Radial/cirugía , Neuropatía Radial/etiología , Adulto , Descompresión Quirúrgica/métodos , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Miofibroma/patología , Miofibroma/ultraestructura , Nervio Radial/diagnóstico por imagen , Nervio Radial/fisiopatología , Recuperación de la Función , Resultado del Tratamiento
5.
J Radiol Case Rep ; 10(8): 1-11, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27761189

RESUMEN

We present a case in which intraocular silicone injection for complex retinal detachment resulted in migration and distribution of silicone along the intracranial visual pathway, and ultimately throughout the ventricular system. Misinterpretation of this material as intracranial hemorrhage on outside computed tomography imaging delayed emergent repair of a Type A aortic dissection until the diagnosis was made on repeat imaging. A discussion of this case and salient computed tomography and magnetic resonance imaging characteristics of silicone is provided.


Asunto(s)
Aneurisma de la Aorta/diagnóstico por imagen , Disección Aórtica/diagnóstico por imagen , Migración de Cuerpo Extraño/diagnóstico por imagen , Hemorragias Intracraneales/inducido químicamente , Hemorragias Intracraneales/diagnóstico por imagen , Desprendimiento de Retina/tratamiento farmacológico , Siliconas/efectos adversos , Disección Aórtica/cirugía , Aneurisma de la Aorta/cirugía , Diagnóstico Diferencial , Femenino , Humanos , Hemorragias Intracraneales/cirugía , Imagen por Resonancia Magnética , Síndrome de Marfan/complicaciones , Persona de Mediana Edad , Siliconas/administración & dosificación , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA