RESUMEN
OBJECTIVE: Total transfemoral (TF) access has been increasingly used during fenestrated-branched endovascular aortic repair (FB-EVAR). However, it is unclear whether the potential decrease in the risk of cerebrovascular events is offset by increased procedural difficulties and other complications. The aim of this study was to compare outcomes of FB-EVAR using a TF vs upper extremity (UE) approach for target artery incorporation. METHODS: We analyzed the clinical data of consecutive patients enrolled in a prospective, nonrandomized clinical trial in two centers to investigate the use of FB-EVAR for treatment of complex abdominal aortic aneurysms (CAAA) and thoracoabdominal aortic aneurysms (TAAA) between 2013 and 2022. Patients were classified into TF or UE access group with a subset analysis of patients treated using designs with directional branches. End points were technical success, procedural metrics, 30-day cerebrovascular events defined as stroke or transient ischemic attack, and any major adverse events (MAEs). RESULTS: There were 541 patients (70% males; mean age, 74 ± 8 years) treated by FB-EVAR with 2107 renal-mesenteric TAs incorporated. TF was used in175 patients (32%) and UE in 366 patients (68%) including 146 (83%) TF and 314 (86%) UE access patients who had four or more TAs incorporated. The use of a TF approach increased from 8% between 2013 and 2017 to 31% between 2018 and 2020 and 96% between 2021 and 2022. Compared with UE access patients, TF access patients were more likely to have CAAAs (37% vs 24%; P = .002) as opposed to TAAAs. Technical success rate was 96% in both groups (P = .96). The use of the TF approach was associated with reduced fluoroscopy time and procedural time (each P < .05). The 30-day mortality rate was 0.6% for TF and 1.4% for UE (P = .67). There was no early cerebrovascular event in the TF group, but the incidence was 2.7% for UE patients (P = .035). The incidence of MAEs was also lower in the TF group (9% vs 18%; P = .006). Among 237 patients treated using devices with directional branches, there were no significant differences in outcomes except for a reduced procedural time for TF compared with UE access patients (P < .001). CONCLUSIONS: TF access was associated with a decreased incidence of early cerebrovascular events and MAEs compared with UE access for target artery incorporation. Procedural time was decreased in TF access patients irrespective of the type of stent graft design.
Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Femenino , Prótesis Vascular , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Factores de Riesgo , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/etiología , Extremidad Superior , Resultado del Tratamiento , Estudios RetrospectivosRESUMEN
OBJECTIVE: Endovascular repair of aortic dissections may be complicated by inadequate sealing zones, persistent false lumen perfusion, and limited space for catheter manipulation and target artery incorporation. The aim of this study was to describe the indications, technical success, and early outcomes of transcatheter electrosurgical septotomy (TES) during endovascular repair of aortic dissections. METHODS: We reviewed the clinical data of consecutive patients treated by endovascular repair of aortic dissections with adjunctive TES in two centers between 2021 and 2023. End points were technical success, defined by successful septotomy without dislodgment of the lamella or target artery occlusion, and 30-day rates of major adverse events (MAEs). RESULTS: Among 197 patients treated by endovascular repair for aortic dissections, 36 patients (18%) (median age, 61.5 years (interquartile range, 55.0-72.5 years; 83% male) underwent adjunctive TES for acute (n = 3 [8%]), subacute (n = 1 [3%]), or chronic postdissection aneurysms (n = 32 [89%]). Indications for TES were severe true lumen (TL) compression (≤16 mm) in 28 patients (78%), target vessel origin from false lumen in 19 (53%), creation of suitable landing zone in 12 (33%), and organ/limb malperfusion in four (11%). Endovascular repair included fenestrated-branched endovascular aortic repair (EVAR) in 18 patients (50%), thoracic EVAR/EVAR/PETTICOAT in 11 (31%), and arch branch repair in 7 (19%). All patients had dissections extending through zones 5 to 7, and 28 patients (78%) underwent TES across the renal-mesenteric segment. Technical success of TES was 92% (33/36) for all patients and 97% (32/33) among those with subacute or chronic postdissection aneurysms. There were three technical failures, including two patients with acute dissections with inadvertent superior mesenteric artery dissection in one patient and distal dislodgement of the dissection lamella in two patients. There were no arterial disruptions. The mean postseptotomy aortic lumen increased from 13.2 ± 4.8 mm to 28.4 ± 6.8 mm (P < .001). All 18 patients treated by fenestrated-branched EVAR had successful incorporation of 78 target arteries. There was one early death (3%) from stroke, and three patients (8%) had major adverse events. After a median follow-up of 8 months (interquartile range, 4.5-13.5 months), 13 patients (36%) had secondary interventions, and two (6%) died from non-aortic-related events. There were no other complications associated with TES. CONCLUSIONS: TES is an adjunctive technique that may optimize sealing zones and luminal aortic diameter during endovascular repair of subacute and chronic postdissection. Although no arterial disruptions or target vessel loss occurred, patients with acute dissections are prone to technical failures related to dislodgement of the lamella.
Asunto(s)
Disección Aórtica , Implantación de Prótesis Vascular , Electrocirugia , Procedimientos Endovasculares , Complicaciones Posoperatorias , Humanos , Disección Aórtica/cirugía , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Masculino , Femenino , Persona de Mediana Edad , Anciano , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/mortalidad , Resultado del Tratamiento , Estudios Retrospectivos , Electrocirugia/efectos adversos , Electrocirugia/métodos , Factores de Tiempo , Complicaciones Posoperatorias/etiología , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Implantación de Prótesis Vascular/métodos , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/mortalidad , Factores de RiesgoRESUMEN
OBJECTIVES: To investigate the impact of 1-year changes in aneurysm sac diameter on patient survival after fenestrated-branched endovascular aortic repair (FB-EVAR) of complex abdominal aortic aneurysms or thoracoabdominal aortic aneurysms. METHODS: We reviewed the clinical data of patients enrolled in a prospective nonrandomized study investigating FB-EVAR (2013-2022). Patients with sequential follow up computed tomography scans at baseline and 6 to 18 months after FB-EVAR were included in the analysis. Aneurysm sac diameter change was defined as the difference in maximum aortic diameter from baseline measurements obtained in centerline of flow. Patients were classified as those with sac shrinkage (≥5 mm) or failure to regress (<5 mm or expansion) according to sac diameter change. The primary end point was all-cause mortality. Secondary end points were aortic-related mortality (ARM), aortic aneurysm rupture (AAR), and aorta-related secondary intervention. RESULTS: There were 549 patients treated by FB-EVAR. Of these, 463 patients (71% male, mean age, 74 ± 8 years) with sequential computed tomography imaging were investigated. Aneurysm extent was thoracoabdominal aortic aneurysms in 328 patients (71%) and abdominal aortic aneurysms in 135 (29%). Sac shrinkage occurred in 270 patients (58%) and failure to regress in 193 patients (42%), including 19 patients (4%) with sac expansion at 1 year. Patients from both groups had similar cardiovascular risk factors, except for younger age among patients with sac shrinkage (73 ± 8 years vs 75 ± 8 years; P < .001). The median follow-up was 38 months (interquartile range, 18-51 months). The 5-year survival estimate was 69% ± 4.1% for the sac shrinkage group and 46% ± 6.2% for the failure to regress group. Survival estimates adjusted for confounders (age, chronic pulmonary obstructive disease, chronic kidney disease, congestive heart failure, and aneurysm extent) revealed a higher hazard of late mortality in patients with failure to regress (adjusted hazard ratio, 1.72; 95% confidence interval, 1.18-2.52; P = .005). The 5-year cumulative incidences of ARM (1.1% vs 3.1%; P = .30), AAR (0.6% vs 2.6%; P = .20), and aorta-related secondary intervention (17.0% ± 2.8% vs 19.0% ± 3.8%) were both comparable between the groups. CONCLUSIONS: Aneurysm sac shrinkage at 1 year is common after FB-EVAR and is associated with improved patient survival, whereas sac enlargement affects only a minority of patients. The low incidences of ARM and AAR indicate that failure to regress may serve as a surrogate marker for nonaortic-related death.
Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Femenino , Anciano , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Procedimientos Endovasculares/instrumentación , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/mortalidad , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Factores de Tiempo , Anciano de 80 o más Años , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Implantación de Prótesis Vascular/instrumentación , Factores de Riesgo , Resultado del Tratamiento , Prótesis Vascular , Diseño de Prótesis , Estudios Prospectivos , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/etiología , Angiografía por Tomografía Computarizada , Aortografía/métodos , Estudios Retrospectivos , Medición de Riesgo , Reparación Endovascular de AneurismasRESUMEN
This manuscript is intended to provide a comprehensive review of the current state of knowledge on endovascular repair of thoracoabdominal aortic aneurysms (TAAAs). The management of these complex aneurysms requires an interdisciplinary and patient-specific approach in high-volume centers. An index case is used to discuss the diagnosis and treatment of a patient undergoing fenestrated-branched endovascular aneurysm repair for a TAAA.
Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Diseño de Prótesis , Complicaciones PosoperatoriasRESUMEN
OBJECTIVE: Stenting of renal and mesenteric vessels may result in changes in velocity measurements due to arterial compliance, potentially giving rise to confusion about the presence of stenosis during follow-up. The aim of our study was to compare preoperative and postoperative changes in peak systolic velocity (PSV, cm/s) after placement of the celiac axis (CA), superior mesenteric artery (SMA) and renal artery (RAs) bridging stent grafts during fenestrated-branched endovascular aortic repair (FB-EVAR) for treatment of complex abdominal aortic aneurysms (AAA) and thoracoabdominal aortic aneurysms. METHODS: Patients were enrolled in a prospective, nonrandomized single-center study to evaluate FB-EVAR for treatment of complex AAA and thoracoabdominal aortic aneurysms between 2013 and 2020. Duplex ultrasound examination of renal-mesenteric vessels were obtained prospectively preoperatively and at 6 to 8 weeks after the procedure. Duplex ultrasound examination was performed by a single vascular laboratory team using a predefined protocol including PSV measurements obtained with <60° angles. All renal-mesenteric vessels incorporated by bridging stent grafts using fenestrations or directional branches were analyzed. Target vessels with significant stenosis in the preoperative exam were excluded from the analysis. The end point was variations in PSV poststent placement at the origin, proximal, and mid segments of the target vessels for fenestrations and branches. RESULTS: There were 419 patients (292 male; mean age, 74 ± 8 years) treated by FB-EVAR with 1411 renal-mesenteric targeted vessels, including 260 CAs, 409 SMAs, and 742 RAs. No significant variances in the mean PSVs of all segments of the CA, SMA, and RAs at 6 to 8 weeks after surgery were found as compared with the preoperative values (CA, 135 cm/s vs 141 cm/s [P = .06]; SMA, 128 cm/s vs 125 cm/s [P = .62]; RAs, 90 cm/s vs 83 cm/s [P = .65]). Compared with baseline preoperative values, the PSV of the targeted vessels showed no significant differences in the origin and proximal segment of all vessels. However, the PSV increased significantly in the mid segment of all target vessels after stent placement. CONCLUSIONS: Stent placement in nonstenotic renal and mesenteric vessels during FB-EVAR is not associated with a significant increase in PSVs at the origin and proximal segments of the target vessels. Although there is a modest but significant increase in velocity measurements in the mid segment of the stented vessel, this difference is not clinically significant. Furthermore, PSVs in stented renal and mesenteric arteries were well below the threshold for significant stenosis in native vessels. These values provide a baseline or benchmark for expected PSVs after renal-mesenteric stenting during FB-EVAR.
RESUMEN
Aortic dissection often results in chronic aneurysmal degeneration due to progressive false lumen expansion. Thoracic endovascular aortic repair and other techniques of vessel incorporation such as fenestrated-branched or parallel grafts have been increasingly used to treat chronic postdissection aneurysms. True lumen compression or a vessel origin from the false lumen can present considerable technical challenges. In these cases, the limited true lumen space can result in inadequate stent graft expansion or restrict the ability to reposition the device or manipulate catheters. Reentrance techniques can be used selectively to assist with target vessel catheterization. Transcatheter electrosurgical septotomy is a novel technique that has evolved from the cardiology experience with transseptal or transcatheter aortic valve procedures. This technique has been applied in select patients with chronic dissection to create a proximal or distal landing zone, disrupt the septum in patients with an excessively compressed true lumen, or connect the true and false lumen in patients with vessels that have separate origins. In the present report, we summarize the indications and technical pitfalls of transcatheter electrosurgical septotomy in patients treated by endovascular repair for chronic postdissection aortic aneurysms.
RESUMEN
INTRODUCTION: Repair of thoracoabdominal aortic aneurysms (TAAAs) represents a technical challenge regardless of which technique is used. Open surgical repair (OSR) is the time-tested option against which novel techniques must be compared and it is still considered the gold standard option for younger, fit patients with heritable aortic diseases. Endovascular repair offers a less-invasive alternative in patients with suitable anatomy. This article aims to present a tabular review of the contemporary published data on endovascular repair of TAAAs using fenestrated-branched techniques. EVIDENCE ACQUISITION: The published literature for single-center and multicenter studies evaluating the outcomes of FB-EVAR for TAAAs was searched using MEDLINE and Embase databases. Studies published between January 1st 2010 and July 11th 2024, in the English language which provided data on FB-EVAR of TAAAs with more than fifty reported cases were included. EVIDENCE SYNTHESIS: The average patient age at time of repair was 71 years old with majority of males (65.5%). Most patients presented with a Crawford Extent II TAAAs (21.6%), followed by Extent III (21.2%). Early mortality was 4.9% for the entire cohort. The most prevalent adverse event was acute kidney injury (9.4%), followed by spinal cord injury (8.0%). CONCLUSIONS: FB-EVAR of TAAAs continues to evolve. Pooled analysis of early mortality and morbidity is lower in this tabular review than historical outcomes of open TAAA repair.