Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Catheter Cardiovasc Interv ; 94(3): 427-435, 2019 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-30592134

RESUMEN

OBJECTIVES: To report mid-term results after MitraClip repair, according to mitral regurgitation (MR) mechanism, in a real-world single-center experience. BACKGROUND: Mid-term outcomes of percutaneous edge-to-edge mitral repair in the real world are still limited. METHODS: We assessed the follow-up results of patients treated with MitraClip at a single high-volume mitral center from 2008 to 2016. All patients underwent Heart-Team discussion, prospective data collection and enrolment in a dedicated outpatient clinic. Functional (FMR, n = 242, 68.6%) and degenerative (DMR, n = 97, 27.5%) MR patients were separately analyzed. RESULTS: 5-Year survival was 53.5 ± 4.5% in FMR vs 57.1 ± 7.5% in DMR (P = 0.087). Reduced survival was strongly associated with worse left ventricle remodeling (ESV HR 1.01, CI 1.01-1.02, P < 0.001) in FMR, and with worse symptoms (New York Heart Association IV HR 6.72, CI 1.78-25.45, P = 0.005) in DMR. 5-Year cumulative incidence function for MR ≥ 3 was 23.7 ± 3.4% in FMR vs 27.9 ± 5.9% in DMR (P = 0.39), being associated with residual MR = 2 both in FMR (HR 4.67, CI 2.49-8.74, P < 0.001) and DMR (HR 7.15, CI 2.72-18.75, P < 0.001). At 5-year, patients in NYHA class I-II increased from 17.9% to 45.3% in FMR (P < 0.001) and from 33.3% to 51.3% in DMR (P < 0.001). CONCLUSIONS: In this single-center real-world experience, 5-year after MitraClip, half of the patients were alive and 3/4 were free from MR, both in FMR and DMR. Symptoms benefit was sustained in both groups. Advanced ventricular remodeling, advanced symptoms, and suboptimal MR reduction were associated with worse results. Refined patient selection, improved efficacy and more data will be all required to improve long-term outcomes.


Asunto(s)
Cateterismo Cardíaco , Procedimientos Quirúrgicos Cardíacos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/mortalidad , Femenino , Hemodinámica , Hospitales de Alto Volumen , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Supervivencia sin Progresión , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Función Ventricular Izquierda , Remodelación Ventricular
2.
J Thorac Cardiovasc Surg ; 158(1): 86-94.e1, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30797588

RESUMEN

OBJECTIVE: To compare the outcomes of MitraClip and surgical mitral repair in low-intermediate risk elderly patients affected by degenerative mitral regurgitation (DMR). METHODS: We retrospectively selected patients aged ≥75 years, with Society of Thoracic Surgeons Predicted Risk Of Mortality (STS-PROM) <8%, submitted to MitraClip (n = 100) or isolated surgical repair (n = 206) for DMR at 2 centers between January 2005 and May 2017. To adjust for baseline imbalances, we used a propensity score model for average treatment effect on survival. RESULTS: After weighting, MitraClip showed fewer postoperative complications (P < .05) but increased residual mitral regurgitation (MR) ≥2 (27.0% vs 2.8%, P < .001) compared with surgery. One-year survival was greater after MitraClip compared with surgery (97.6% vs 95.3%, hazard ratio [HR], 0.09; confidence interval [CI], 0.02-0.37, P = .001), whereas 5-year survival was lower (34.5% vs 82.2% respectively, HR, 4.12; CI, 2.31-7.34, P < .001). Greater STS-PROM (HR, 1.18; CI, 1.12-1.24, P < .001) and MR ≥3+ recurrence (HR, 2.18; CI, 1.07-4.48, P = .033) were associated with reduced survival. 5-year MR ≥3+ was more frequent after MitraClip compared with surgery: 36.9% versus 3.9%, odds ratio, 11.4; CI, 4.40-29.68, P < .001. CONCLUSIONS: In elderly patients affected by DMR and STS-PROM <8%, the average effect of MitraClip resulted in lower acute postoperative complications and improved 1-year survival compared with surgery. However, MitraClip was associated with greater MR recurrence and reduced survival beyond 1 year. Long-term survival was impaired by patients' greater risk profile and MR recurrence. Early results are promising, but in the setting of operable patients with life expectancy beyond 1 year, the quality bar for transcatheter mitral repair needs to be raised.


Asunto(s)
Procedimientos Endovasculares/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Procedimientos Endovasculares/mortalidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Puntaje de Propensión , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Análisis de Supervivencia
3.
Eur J Cardiothorac Surg ; 52(1): 137-142, 2017 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-28329199

RESUMEN

OBJECTIVES: A single MitraClip implant is often considered enough to achieve adequate mitral regurgitation (MR) reduction. The aim of this study was to compare MR recurrence in patients with an initial optimal result treated with a single clip versus those treated with two clips. METHODS: From October 2008 to May 2016, 322 patients were treated with the MitraClip procedure at our institution. We retrospectively selected all patients treated for functional MR (FMR) and degenerative MR (DMR) aetiologies with residual MR ≤1+, excluding patients who required >2 clips. FMR and DMR were analysed separately. RESULTS: In FMR, a single clip was used in 45 patients and 2 clips in 99 patients. The single clip group had smaller coaptation depth (1.1 ± 0.3 vs 1.3 ± 0.3 mm, P = 0.022) and jet extension (10.5 ± 2.1 vs 13.0 ± 3.6 mm, P = 0.026) as well as left ventricular end-diastolic diameter (64.4 ± 7.3 vs 69.0 ± 7.9 mm, P = 0.001). Freedom from MR ≥ 3+ after 4 years was 71.9 ± 8.9% in patients receiving a single clip vs 88.0 ± 5.2% in those receiving 2 clips, single clip use being an independent predictor of MR recurrence (HR 3.48, CI 1.24-9.81, P = 0.018). In DMR, a single clip was deployed in 24 patients and 2 clips in 30 patients. The single clip group had a smaller flail gap (3.6 ± 0.7 vs 6.8 ± 2.5, P = 0.002). Freedom from MR ≥ 3+ after 2 years was 82.5 ± 8% in patients with a single clip vs 100% in those with 2 clips, P = 0.014. The residual mitral area was reduced in patients with 2 clips compared with those with single clip, both in FMR ( P = 0.015) and DMR ( P = 0.039), but it was not associated with increased death rate during the follow-up period (all P > 0.05). CONCLUSIONS: Despite favourable anatomical characteristics and an optimal initial result, implantation of a single clip was associated with an increased recurrence of MR compared with that of 2 clips, both in FMR and in DMR. Caution should be exercised with the implantation of a single clip.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Instrumentos Quirúrgicos , Anciano , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA