Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
N Z Vet J ; 65(1): 30-33, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27643681

RESUMEN

AIMS: To compare the prevalence of minor incisional complications in canine patients undergoing tibial plateau levelling osteotomy (TPLO) surgery that had a hydrogel liquid bandage (HLB) applied to their incision, with patients that had a light adhesive bandage applied. METHODS: Thirty dogs undergoing TPLO surgery were randomly assigned to either application of a light adhesive bandage to the incision, with removal 18-24 hours later, or application of a clear-drying polyethylene glycol HLB to the incision. Erythema, swelling, discharge, and dehiscence were assessed 1 day (Day 1) and 10-14 days (Days 10-14) postoperatively. All persons completing the assessment were blinded to the treatment. Outcomes were compared for the two groups using Fisher's Exact Test. RESULTS: On both Day 1 and Days 10-14, the distribution of dogs with erthemyma or swelling did not differ between the two groups (p≥0.4). The prevalence of erythema was the same in the bandage and HLB groups at Day 1 (11/15; 73%) and was similar at Days 10-14 (3/11 (27%) and 2/11 (18%), respectively). Prevalence of swelling was also the same in the two groups on Day 1 (11/15; 73%) and was similar at Days 10-14 (3/11 (27%) and 6/11 (55%), respectively). On Day 1, 2/15 (13%) dogs in the HLB group and none of the dogs in the bandage group had incisional discharge (p=0.483). No dogs were observed with discharge on Days 10-14. No dehiscence, infection, or any other major incisional complication was observed in either group at any point in the study. CONCLUSIONS: Preliminary results suggest that prevalence of minor incisional complications after TPLO surgery treated with HLB or with a traditional adhesive bandage may be comparable. No major adverse effects were seen with the use of HLB. CLINICIAL RELEVANCE: Due to several disadvantages of traditional bandaging, which can require post-operative maintenance and removal, lasts only a short time, and be painful when removed, an alternative with fewer drawbacks is desirable. HLB may present such an alternative.


Asunto(s)
Vendas Hidrocoloidales/veterinaria , Perros/cirugía , Osteotomía/veterinaria , Tibia/cirugía , Animales , Eritema/prevención & control , Eritema/veterinaria , Osteotomía/métodos , Cuidados Posoperatorios/veterinaria
2.
Vet Surg ; 34(2): 108-13, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15860100

RESUMEN

OBJECTIVE: To evaluate the accuracy of linear measurements obtained from computer tomography (CT) images of staged radio-ulnar incongruence in a canine cadaver forelimb model. STUDY DESIGN: CT evaluation of induced progressive radio-ulnar incongruence in canine cadaveric forelimbs. SAMPLE POPULATION: Eight cadaveric canine left forelimbs. PROCEDURE: A type 2 external skeletal fixator (ESF) with linear motors was attached to the radius in 8 cadaveric left canine forelimbs. Contiguous incremental and helical CT images of the proximal radio-ulnar articulation were acquired in the transverse, sagittal and dorsal planes. The radius was shortened by 1, 2, and 4 mm increments and scanning protocols were repeated at each increment. Digital caliper and CT image analysis measured the progressive change in distance between 2 marking spheres and the epiphyseal bone surfaces of the radio-ulnar articulation. Statistical analysis of measurements from incremental and helical CT acquisitions, and direct and reformatted images were compared with inter-sphere distance using Pearson product moment correlation coefficients. RESULTS: The reformatted incremental acquisition series at the mid-coronoid in the oblique plane had the highest correlation coefficient (r-value) at 0.908. The mid-coronoid in the dorsal plane had the second highest r-value (0.856). The coronoid incisure in the sagittal plane had an r-value of 0.826. The reformatted incremental acquisition series at the coronoid incisure in the oblique plane had the lowest r-value, 0.592. CONCLUSION: Measurement of radioulnar incongruence may be best performed using reformatted incremental acquisition CT in the mid-coronoid region in an oblique plane. CLINICAL RELEVANCE: Use of the technique reported in this study may enable determination of the association, if any, between radioulnar incongruence and developmental diseases of the canine elbow.


Asunto(s)
Enfermedades de los Perros/diagnóstico por imagen , Luxaciones Articulares/veterinaria , Radio (Anatomía)/diagnóstico por imagen , Tomografía Computarizada por Rayos X/veterinaria , Cúbito/diagnóstico por imagen , Animales , Cadáver , Enfermedades de los Perros/etiología , Perros , Fijadores Externos/veterinaria , Miembro Anterior/diagnóstico por imagen , Luxaciones Articulares/complicaciones , Luxaciones Articulares/diagnóstico por imagen , Osteoartritis/etiología , Osteoartritis/veterinaria , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA