Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur Radiol ; 34(9): 5588-5594, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38345608

RESUMEN

OBJECTIVES: In the presence of escalating global concerns regarding physician burnout, this study aims to analyze the prevalence and associated factors of burnout among radiologists in Germany. METHODS: A comprehensive online survey, inclusive of 73 targeted questions including a German-modified version of the Maslach Burnout Inventory, was distributed among all members of the German Radiological Society and the German Interventional Radiological Society between May and August 2023. The survey encompassed aspects of employment, workload, well-being, and coping mechanisms. Data from 172 completed surveys were analyzed, with correlations explored via crosstabs and the Pearson-chi-square test. RESULTS: In total, 76.7% of participating radiologists were identified to be burnt out. The prevalence was significantly associated with increased workload, reduced sleep quality, suboptimal working conditions, reduced job satisfaction, and the negative interplay between work, family life, and health. Median work satisfaction was described as "satisfied" while median workload was assessed as "frequently overwhelming of work." A total of 41.9% of respondents noted facing daily time pressure. Radiologists' concerns about work interfering with private family life were voiced by approximately 70%, and 73.3% highlighted the perceived negative effects on their health. CONCLUSION: The pronounced prevalence of burnout among German radiologists demonstrates an urgent, unmet need for comprehensive interventions and systemic changes. Our findings act as a catalyst for initiating targeted, multifaceted strategies and dialogs, essential for fostering a resilient and effective healthcare ecosystem. Further large-scale systematic studies should follow to analyze the findings in broad. CLINICAL RELEVANCE STATEMENT: Consistent with other countries, there is a high prevalence of burnout among radiologists in Germany. A call for further investigation is recommended to help mitigate adverse outcomes associated with physician burnout. KEY POINTS: • The prevalence of burnout has yet not been evaluated for German radiologists. • German radiologists have a high prevalence of burnout. • Steps must be implemented to engage this problem to prevent worsening.


Asunto(s)
Agotamiento Profesional , Satisfacción en el Trabajo , Radiólogos , Carga de Trabajo , Agotamiento Profesional/epidemiología , Humanos , Alemania/epidemiología , Radiólogos/psicología , Prevalencia , Femenino , Masculino , Encuestas y Cuestionarios , Persona de Mediana Edad , Adulto
2.
Acta Radiol ; 65(7): 774-783, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38841768

RESUMEN

BACKGROUND: Image quality and diagnostic accuracy in computed tomography angiography (CTA) reach their limits in imaging of below-the-knee vessels. PURPOSE: To evaluate whether image quality in CTA of lower limbs is further improvable by combining side-separate reconstruction with a larger matrix size and whether resulting noise can be compromised with iterative reconstruction (IR). MATERIAL AND METHODS: From CTA of the lower extremities of 26 patients (5 women, 21 men; mean age = 68.5 ± 10.3 years), the lower legs were reconstructed side-separately with different reconstruction algorithms and matrix sizes including filtered back projection (FBP) with a 512 × 512 matrix, FBP with a 1024 × 1024 matrix, IR (SAFIRE) with a 512 × 512 matrix, and IR (SAFIRE) with a 1024 × 1024 matrix. A total of 208 CT series were evaluated. Subjective image quality was assessed by two readers using a 5-point Likert scale. Image noise was assessed by measuring signal-to-noise and contrast-to-noise ratios. RESULTS: Subjective image quality was rated significantly higher when using a 1024 × 1024 matrix (P < 0.001) and could further be increased with IR. Vessel sharpness was rated significantly better with a larger matrix (P < 0.001). Visible and measured image noise was significantly higher with a 1024 × 1024 matrix but could be reduced by using IR (P < 0.001), even to a level below FBP with a 512 × 512 matrix while reconstructing with a larger matrix (P < 0.001). CONCLUSION: Image quality, image noise, and vessel sharpness can be further improved in CTA of the lower extremities with side-separate reconstruction using a 1024 × 1024 matrix size and IR.


Asunto(s)
Angiografía por Tomografía Computarizada , Extremidad Inferior , Interpretación de Imagen Radiográfica Asistida por Computador , Humanos , Femenino , Masculino , Angiografía por Tomografía Computarizada/métodos , Anciano , Extremidad Inferior/irrigación sanguínea , Extremidad Inferior/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Persona de Mediana Edad , Relación Señal-Ruido , Algoritmos , Anciano de 80 o más Años , Medios de Contraste , Procesamiento de Imagen Asistido por Computador/métodos
3.
Cardiovasc Intervent Radiol ; 47(2): 245-250, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37872295

RESUMEN

PURPOSE: This study explores the utility of the large language models, GPT-3 and GPT-4, for in-depth patient education prior to interventional radiology procedures. Further, differences in answer accuracy between the models were assessed. MATERIALS AND METHODS: A total of 133 questions related to three specific interventional radiology procedures (Port implantation, PTA and TACE) covering general information as well as preparation details, risks and complications and post procedural aftercare were compiled. Responses of GPT-3 and GPT-4 were assessed for their accuracy by two board-certified radiologists using a 5-point Likert scale. The performance difference between GPT-3 and GPT-4 was analyzed. RESULTS: Both GPT-3 and GPT-4 responded with (5) "completely correct" (4) "very good" answers for the majority of questions ((5) 30.8% + (4) 48.1% for GPT-3 and (5) 35.3% + (4) 47.4% for GPT-4). GPT-3 and GPT-4 provided (3) "acceptable" responses 15.8% and 15.0% of the time, respectively. GPT-3 provided (2) "mostly incorrect" responses in 5.3% of instances, while GPT-4 had a lower rate of such occurrences, at just 2.3%. No response was identified as potentially harmful. GPT-4 was found to give significantly more accurate responses than GPT-3 (p = 0.043). CONCLUSION: GPT-3 and GPT-4 emerge as relatively safe and accurate tools for patient education in interventional radiology. GPT-4 showed a slightly better performance. The feasibility and accuracy of these models suggest their promising role in revolutionizing patient care. Still, users need to be aware of possible limitations.


Asunto(s)
Educación del Paciente como Asunto , Radiología Intervencionista , Humanos , Estudios de Factibilidad , Concienciación , Certificación
4.
Rofo ; 196(11): 1161-1165, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38408472

RESUMEN

PURPOSE: Endovascular interventional radiological procedures have become the mainstay for the treatment of critical limb ischemia (CLI) due to arterial stenosis or occlusion. Open surgical or endovascular procedures, such as percutaneous transluminal angioplasty (PTA) or stenting can be used as a treatment strategy. The aim is to evaluate the success and major complication rates of interventional radiology treatments for CLI in Germany in 2021, and to compare these results with internationally published data. MATERIALS AND METHODS: Data for PTA and stenting in CLI for 2021 was obtained from the quality management system of the German Society of Interventional Radiology (DeGIR). 16 393 PTA procedures, 701 stenting procedures, and 8110 combined procedures were documented for 2021. Data was analyzed for technical and clinical success rates, as well as major complication rates documented mainly as major bleeding, distal embolization, and aneurysm formation. RESULTS: PTA had technical and clinical success rates of 96.3 % and 92.33 %, respectively. Stenting had technical and clinical success rates of 98.7 % and 96.15 %, respectively. PTA and stenting combined had success rates of 98.71 % and 96.91 %, respectively. The major complications were mainly: major bleeding (PTA: 0.40 %; stenting: 1.28 %; PTA and stenting: 0.54 %), distal embolization (PTA: 0.48 %; stenting: 1 %; PTA and stenting: 0.96 %), and aneurysm formation (PTA: 0.19 %; stenting: 0.43 %; PTA and stenting: 0.19 %). All procedures showed high technical and clinical success rates, while the complication rates were low. CONCLUSION: Interventional radiologists in Germany perform effective and safe treatment for CLI, achieving outcomes that tend to surpass internationally published data. KEY POINTS: · German interventional radiologists provide safe and effective critical limb ischemia treatment.. · Major complications occurred at maximum in 1.28 % of cases.. · Outcomes tend to surpass international data, indicating strong performance.. CITATION FORMAT: · Bastian M, Scheschenja M, Wessendorf J et al. Assessment of Efficacy and Complications of Endovascular Interventions for Critical Limb Ischemia in Germany: A Nationwide Study. Fortschr Röntgenstr 2024; 196: 1161 - 1165.


Asunto(s)
Procedimientos Endovasculares , Isquemia , Stents , Isquemia/diagnóstico por imagen , Isquemia/terapia , Isquemia/cirugía , Humanos , Alemania , Procedimientos Endovasculares/métodos , Masculino , Femenino , Complicaciones Posoperatorias/diagnóstico por imagen , Anciano , Resultado del Tratamiento , Angioplastia , Persona de Mediana Edad , Anciano de 80 o más Años , Radiografía Intervencional
5.
Rofo ; 196(11): 1155-1160, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38408473

RESUMEN

PURPOSE: Endovascular treatment has emerged as the gold standard for managing chronic mesenteric ischemia (CMI) resulting from arterial stenosis or occlusion. This study aimed to assess the efficacy and complication rates of continuous interventional radiology treatment for CMI in Germany between 2018 and 2021, comparing these findings with international quality standards. MATERIALS AND METHODS: Data for CMI therapy with stenting and percutaneous transluminal angioplasty (PTA) was obtained from the quality management system of the German Interventional Radiological Society (DeGIR). A total of 3752 endovascular procedures for CMI performed from 2018 to 2021 were documented (PTA: n = 675; stenting: n = 3077). Data was analyzed for technical and clinical success rates, as well as major complication rates. RESULTS: Overall technical and clinical success rates for PTA and stenting procedures were 92.03 %/85.9 % and 98.76 %/96.62 %, respectively. The most common major complications were: arterial occlusion (PTA: 0.73 %; stenting: 0.63), major bleeding (PTA: 1.05 %; stenting: 0.68 %), aneurysm formation (PTA: 0.29 %; stenting: 0.72 %), stent dislodgment (PTA: 0 %; stenting: 0.06 %), and organ failure (PTA: 0.43 %; stenting: 0.96 %). Technical and clinical success rates were higher, while complication rates were lower than the corresponding threshold recommended by the Society of Interventional Radiology for the percutaneous management of chronic mesenteric ischemia. CONCLUSION: Treatment of CMI performed by interventional radiologists in Germany is safe and effective during daily and on-call shifts with results exceeding internationally accepted standards. KEY POINTS: · Treatment of CMI by interventional radiologists in Germany is effective and safe.. · The interventions are safe and effective regardless of whether they are performed during on-call shifts or the daily routine.. · The clinical and technical success rates favorably surpass the thresholds presented by SIR.. · Different major complications occurred in under 1.1 % of CMI interventions.. CITATION FORMAT: · Bastian M, Wessendorf J, Scheschenja M et al. Retrospective evaluation of interventional radiological treatments for chronic mesenteric ischemia in Germany based on a four-year period of the DeGIR Registry: comparison of outcomes with international quality standards . Fortschr Röntgenstr 2024; 196: 1155 - 1160.


Asunto(s)
Isquemia Mesentérica , Sistema de Registros , Stents , Alemania , Isquemia Mesentérica/diagnóstico por imagen , Isquemia Mesentérica/terapia , Humanos , Estudios Retrospectivos , Enfermedad Crónica , Masculino , Femenino , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Angioplastia , Radiología Intervencionista/normas , Procedimientos Endovasculares , Complicaciones Posoperatorias , Anciano de 80 o más Años
6.
Cardiovasc Intervent Radiol ; 47(11): 1527-1531, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38987424

RESUMEN

PURPOSE: The study aims to show how the "Puncture Cube" (PC) (Medical Templates, Egg, Switzerland) compares to the freehand method (FHM) for CT-guided punctures. METHODS: The PC is a patient-mounted disassemblable cube consisting of an upper and lower template with multiple holes each to predefine puncture trajectory. A total of 80 punctures (FHM in-plane, FHM off-plane, PC in-plane, PC off-plane) was performed by 4 radiologists on a target 9.1 cm below surface level of a neoprene covered elliptical cylinder gelatin phantom. The PC was never disassembled. Evaluated parameters were procedure time, number of CT-scans, euclidean distance (ED) and normal distance (ND). Respective parameters of FHM and PC were compared using the Wilcoxon signed-rank test and Levene test with significance levels of 5%. RESULTS: PC achieved smaller ED and ND values after initial needle insertion without corrections for both in-plane and off-plane punctures (P > 0.05). Variance of initial NDs was off-plane significantly larger for FHM. Final ED after needle path corrections was smaller for FHM both in- and off-plane (P < 0.05). Final off-plane ND was significantly lower for FHM with no significant difference in final in-plane ND. FHM off-plane punctures were significantly faster. There was no significant difference in CT-scans between both methods. CONCLUSION: Utilizing the PC may improve initial needle positioning and safety especially off-plane. However, better final needle positioning after correction with the greater freedom of movement method may suggest need for disassembly of the cube.


Asunto(s)
Gelatina , Agujas , Fantasmas de Imagen , Punciones , Radiografía Intervencional , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Radiografía Intervencional/métodos
7.
Curr Probl Diagn Radiol ; 53(4): 488-493, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38670921

RESUMEN

OBJECTIVE: This study aimed to assess the feasibility of GPT-4 for answering questions related to contrast media with and without the context of the European Society of Urogenital Radiology (ESUR) guideline on contrast agents. The overarching goal was to determine whether contextual enrichment by providing guideline information improves answers of GPT-4 for clinical decision-making in radiology. METHODS: A set of 64 questions, based on the ESUR guideline on contrast agents mirroring pertinent sections, was developed and posed to GPT-4 both directly and after providing the guideline using a plugin. Responses were graded by experienced radiologists for quality of information and accuracy in pinpointing information from the guideline as well as by radiology residents for utility, using Likert-scales. RESULTS: GPT-4's performance improved significantly with the guideline. Without the guideline, average quality rating was 3.98, which increased to 4.33 with the guideline (p = 0036). In terms of accuracy, 82.3% of answers matched the information from the guideline. Utility scores also reflected a significant improvement with the guideline, with average scores of 4.1 (without) and 4.4 (with) (p = 0.008) with a Fleiss´ Kappa of 0.44. CONCLUSION: GPT-4, when contextually enriched with a guideline, demonstrates enhanced capability in providing guideline-backed recommendations. This approach holds promise for real-time clinical decision-support, making guidelines more actionable. However, further refinements are necessary to maximize the potential of large language models (LLMs). Inherent limitations need to be addressed.


Asunto(s)
Medios de Contraste , Guías de Práctica Clínica como Asunto , Humanos , Estudios de Factibilidad , Toma de Decisiones Clínicas/métodos , Radiología/normas , Encuestas y Cuestionarios , Sociedades Médicas , Europa (Continente)
8.
Eur Radiol Exp ; 7(1): 56, 2023 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-37749303

RESUMEN

BACKGROUND: We evaluated the feasibility of a chick chorioallantoic membrane (CAM) tumor model for preclinical research on tumor radiofrequency ablation (RFA). METHODS: Fertilized chicken eggs were incubated and divided into five cohorts: RFA for 30 s (n = 5), RFA for 60 s (n = 5), RFA for 120 s (n = 4), sham (n = 8), and controls (n = 6). Xenografting using pancreatic neuroendocrine tumor cells of the BON-1 cell line was performed on embryonic day (ED) 8. The RFA was performed on ED 12. Survival, stereomicroscopic observations, and histological observations using hematoxylin-eosin (H&E) and Ki67 staining were evaluated. RESULTS: The survival rates in the 30-s, 60-s, and 120-s, sham and control cohort were 60%, 60%, 0%, 100%, and 50%, respectively. Signs of bleeding and heat damage were common findings in the evaluation of stereomicroscopic observations. Histological examination could be performed in all but one embryo. Heat damage, bleeding, thrombosis, and leukocyte infiltration and hyperemia were regular findings in H&E-stained cuts. A complete absence of Ki67 staining was recorded in 33.3% and 50% of embryos in the 30-s and 60-s cohorts that survived until ED 14, respectively. CONCLUSIONS: The CAM model is a feasible and suiting research model for tumor RFA with many advantages over other animal models. It offers the opportunity to conduct in vivo research under standardized conditions. Further studies are needed to optimize this model for tumor ablations in order to explore promising but unrefined strategies like the combination of RFA and immunotherapy. RELEVANCE STATEMENT: The chick chorioallantoic membrane model allows in vivo research on tumor radiofrequency ablation under standardized conditions that may enable enhanced understanding on combined therapies while ensuring animal welfare in concordance with the "Three Rs." KEY POINTS: • The chorioallantoic membrane model is feasible and suiting for tumor radiofrequency ablation. • Radiofrequency ablation regularly achieved reduction but not eradication of Ki67 staining. • Histological evaluation showed findings comparable to changes in humans after RFA. • The chorioallantoic membrane model can enable studies on combined therapies after optimization.


Asunto(s)
Pollos , Neoplasias Pancreáticas , Humanos , Animales , Membrana Corioalantoides , Estudios de Factibilidad , Antígeno Ki-67 , Eosina Amarillenta-(YS)
9.
CVIR Endovasc ; 6(1): 43, 2023 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-37632599

RESUMEN

PURPOSE: Interventional procedures have become a mainstay in the therapy of acute limb ischemia caused by embolism or arterial thrombosis. Treatment options include pharmacological thrombolysis (PT) and mechanical thrombectomy (MT). The aim of this study was to evaluate success and major complication rates of interventional radiological treatments of arterial embolism and thrombosis in Germany in 2021 and to compare their results with accepted international quality standards. MATERIALS AND METHODS: Data for PT and MT for 2021 was obtained from the quality management system of the German interventional radiological society (DeGIR). 2431 PT and 1582 MT procedures were documented for 2021, with 459 combinations of PT and MT. Data was analysed for technical and clinical success rates, as well as major complication rates such as intracranial bleeding, major bleeding, distal embolization, aneurysm formation, organ-failure and cardiac-decompensation. RESULTS: PT alone had technical and clinical success rate of 90.21% and 81.08%, respectively. MT alone had technical and clinical success rates of 97.41% and 95.39%, respectively. MT&PT had technical and clinical success rates of 91.07% and 84.75%, respectively. Major complications were: distal embolization (PT:2.02%; MT:1.74%; PT&MT:2.61%), major bleeding (PT:0.94%; MT:1.14%; PT&MT:0.87%), aneurysm formation (PT:0.33%;MT: 1.14%;PT&MT: 0%), intracranial bleeding (PT:0.16%;MT:0%;PT&MT:0.22%), cardiac-decompensation (PT:0.21%;MT: 0.06%;PT&MT:0%) and organ-failure (PT:0%;MT:0.06%;PT&MT:0.22%). Technical and clinical success rates were higher, while complication rates were lower than the corresponding threshold recommended by the Society of Interventional Radiology for percutaneous management of acute lower-extremity ischemia. CONCLUSION: Treatment of arterial embolism and thrombosis performed by interventional radiologists in Germany is effective and safe with outcomes exceeding internationally accepted standards.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA