1.
N Engl J Med ; 368(8): 719-27, 2013 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-23425164

RESUMEN

BACKGROUND: Patients with gastroesophageal reflux disease who have a partial response to proton-pump inhibitors often seek alternative therapy. We evaluated the safety and effectiveness of a new magnetic device to augment the lower esophageal sphincter. METHODS: We prospectively assessed 100 patients with gastroesophageal reflux disease before and after sphincter augmentation. The study did not include a concurrent control group. The primary outcome measure was normalization of esophageal acid exposure or a 50% or greater reduction in exposure at 1 year. Secondary outcomes were 50% or greater improvement in quality of life related to gastroesophageal reflux disease and a 50% or greater reduction in the use of proton-pump inhibitors at 1 year. For each outcome, the prespecified definition of successful treatment was achievement of the outcome in at least 60% of the patients. The 3-year results of a 5-year study are reported. RESULTS: The primary outcome was achieved in 64% of patients (95% confidence interval [CI], 54 to 73). For the secondary outcomes, a reduction of 50% or more in the use of proton-pump inhibitors occurred in 93% of patients, and there was improvement of 50% or more in quality-of-life scores in 92%, as compared with scores for patients assessed at baseline while they were not taking proton-pump inhibitors. The most frequent adverse event was dysphagia (in 68% of patients postoperatively, in 11% at 1 year, and in 4% at 3 years). Serious adverse events occurred in six patients, and in six patients the device was removed. CONCLUSIONS: In this single-group evaluation of 100 patients before and after sphincter augmentation with a magnetic device, exposure to esophageal acid decreased, reflux symptoms improved, and use of proton-pump inhibitors decreased. Follow-up studies are needed to assess long-term safety. (Funded by Torax Medical; ClinicalTrials.gov number, NCT00776997.).


Asunto(s)
Esfínter Esofágico Inferior/cirugía , Reflujo Gastroesofágico/cirugía , Imanes , Prótesis e Implantes , Adolescente , Adulto , Anciano , Trastornos de Deglución/etiología , Esofagitis/etiología , Femenino , Reflujo Gastroesofágico/complicaciones , Reflujo Gastroesofágico/tratamiento farmacológico , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Prótesis e Implantes/efectos adversos , Diseño de Prótesis , Inhibidores de la Bomba de Protones/uso terapéutico , Calidad de Vida , Adulto Joven
2.
Clin Gastroenterol Hepatol ; 14(5): 671-7, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26044316

RESUMEN

BACKGROUND & AIMS: Based on results from year 2 of a 5-year trial, in 2012 the US Food and Drug Administration approved the use of a magnetic device to augment lower esophageal sphincter function in patients with gastroesophageal reflux disease (GERD). We report the final results of 5 years of follow-up evaluation of patients who received this device. METHODS: We performed a prospective study of the safety and efficacy of a magnetic device in 100 adults with GERD for 6 months or more, who were partially responsive to daily proton pump inhibitors (PPIs) and had evidence of pathologic esophageal acid exposure, at 14 centers in the United States and The Netherlands. The magnetic device was placed using standard laparoscopic tools and techniques. Eighty-five subjects were followed up for 5 years to evaluate quality of life, reflux control, use of PPIs, and side effects. The GERD-health-related quality of life (GERD-HRQL) questionnaire was administered at baseline to patients on and off PPIs, and after placement of the device; patients served as their own controls. A partial response to PPIs was defined as a GERD-HRQL score of 10 or less on PPIs and a score of 15 or higher off PPIs, or a 6-point or more improvement when scores on vs off PPI were compared. RESULTS: Over the follow-up period, no device erosions, migrations, or malfunctions occurred. At baseline, the median GERD-HRQL scores were 27 in patients not taking PPIs and 11 in patients on PPIs; 5 years after device placement this score decreased to 4. All patients used PPIs at baseline; this value decreased to 15.3% at 5 years. Moderate or severe regurgitation occurred in 57% of subjects at baseline, but only 1.2% at 5 years. All patients reported the ability to belch and vomit if needed. Bothersome dysphagia was present in 5% at baseline and in 6% at 5 years. Bothersome gas-bloat was present in 52% at baseline and decreased to 8.3% at 5 years. CONCLUSIONS: Augmentation of the lower esophageal sphincter with a magnetic device provides significant and sustained control of reflux, with minimal side effects or complications. No new safety risks emerged over a 5-year follow-up period. These findings validate the long-term safety and efficacy of the magnetic sphincter augmentation device for patients with GERD. ClinicalTrials.gov no: NCT00776997.


Asunto(s)
Esfínter Esofágico Inferior/cirugía , Reflujo Gastroesofágico/cirugía , Imanes , Implantación de Prótesis/métodos , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Estudios Prospectivos , Implantación de Prótesis/efectos adversos , Calidad de Vida , Encuestas y Cuestionarios , Resultado del Tratamiento , Estados Unidos , Adulto Joven