1.
Biomed Chromatogr ; 35(5): e5050, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33314228

RESUMEN

A simple and sensitive preconcentration strategy using sequential electrokinetic and hydrodynamic injection modes in micellar electrokinetic chromatography with diode array detection was developed and applied for the separation and determination of anticancer agent, 5-fluorouracil and its metabolite, 5-fluoro-2'-deoxyuridine, in human plasma. Sequential injection modes with increased analyte loading capacity using the anionic pseudo-stationary phase facilitated collection of the dispersed neutral and charged analytes into narrow zones and improved sensitivity. Several important parameters affecting sample enrichment performance were evaluated and optimized in this study. Under the optimized experimental conditions, 614- and 643-fold and 782- and 803-fold sensitivity improvement were obtained for 5-fluorouracil and its metabolite when compared with normal hydrodynamic and electrokinetic injection, respectively. The method has good linearity (1-1,000 ng/ml) with acceptable coefficient of determination (r2 > 0.993), low limits of detection (0.11-0.14 ng/ml) and satisfactory analyte relative recovery (97.4-99.7%) with relative standard deviations of 4.6-9.3% (n = 6). Validation results as well as the application to analysis of human plasma samples from cancer patients demonstrate the applicability of the proposed method to clinical studies.


Asunto(s)
Antineoplásicos/sangre , Cromatografía Capilar Electrocinética Micelar/métodos , Desoxiuridina/análogos & derivados , Fluorouracilo/sangre , Desoxiuridina/sangre , Humanos
2.
J Chromatogr A ; 1685: 463616, 2022 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-36335907

RESUMEN

Realising the need to devise a simple, sensitive, and reliable detection method, this study investigated the development of a dual-stacking transient isotachophoresis (t-ITP) and sweeping in micellar electrokinetic chromatography with diode array detector (t-ITP/sweeping-MEKC-DAD) for the determination of selected non-steroidal anti-inflammatory drugs (NSAIDs); ketoprofen, diclofenac and naproxen from aqueous matrices. Prior to the system setup, various parameters were optimised to assess the potential use of the t-ITP paired with the sweeping stacking technique in micellar background electrolyte for dual preconcentration and separation of trace amounts of NSAIDs. Once the optimum conditions have been established, the method performance was validated and applied to 17 environmental water samples. Based on the results, the combined t-ITP and sweeping approach significantly improved the stacking and separation sensitivity. A large volume of samples could also be introduced and subsequently separated by MEKC with greater focusing effects due to the sweeping. Under optimised conditions, the developed method exhibited excellent linearity at a high range (0.1-500 ng/mL, r2 ≥ 0.998), low limits of detection (LODs) of 0.01-0.07 ng/mL, and a remarkable relative recovery (RR) of 99.6-101.9% with a relative standard deviation (RSD) of 1.4-8.6% (n = 9). Ultimately, the sensitivity enhancement factors improved up to 666-fold using the optimised method. Therefore, the proposed method presents a simplified yet effective and suitable for the determination of NSAIDs from aqueous matrices.


Asunto(s)
Cromatografía Capilar Electrocinética Micelar , Isotacoforesis , Cromatografía Capilar Electrocinética Micelar/métodos , Micelas , Antiinflamatorios no Esteroideos , Agua
3.
Talanta ; 236: 122833, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34635223

RESUMEN

A dynamic pH junction was used in capillary electrophoresis (CE-DAD) to on-line preconcentrate, separate, and determine trace amounts of sulfonamide antibiotics (SAs) in milk and yoghurt samples in this study. A sample matrix with 0.15% acetic acid and 10% methanol (MeOH) at a pH of 4.0, and a background electrolyte (BGE) that contained 35 mM sodium citrate with 10% MeOH at a pH of 8.5, and an acidic barrage of 0.4% acetic acid with 10% MeOH at a pH of 2.5 were utilised to achieve a stacking effect for SAs through a dynamic pH junction. Under optimised conditions, the proposed preconcentration method showed good linearity (30-500 ng/mL, r2 ≥ 0.9940), low limits of detection (LODs) of 4.1-6.3 ng/mL, and acceptable analytes recovery (81.2-106.9%) with relative standard deviations (RSDs) within 5.3-13.7 (n = 9). The limits of quantification (LOQs) were below the maximum residue limit approved by the European Union (EU) in this type of matrices. Sensitivity enhancement factors of up to 129 were reached with the optimised dynamic pH junction using CE with a diode array detector (DAD). The method was used to determine SAs in fresh milk, low-fat milk, full-cream milk, and yoghurt samples.


Asunto(s)
Antibacterianos , Yogur , Animales , Electroforesis Capilar , Concentración de Iones de Hidrógeno , Leche , Sulfonamidas
4.
Talanta ; 199: 522-531, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-30952293

RESUMEN

Molecularly imprinted silica gel (MISG) was incorporated through dispersion in agarose polymer matrix to form a mixed matrix membrane (MMM) and was applied for the determination of three sulfonamide antibiotic compounds (i.e. sulfamethoxazole (SMX), sulfamonomethoxine (SMM), and sulfadiazine (SDZ)) from environmental water samples. Several important microextraction conditions, such as type of desorption solvent, extraction time, amount of sorbent, sample volume, pH, and effect of desorption time, were comprehensively optimized. A preconcentration factors of ≥ 20 was achieved by the extraction of 12.5 mL of water samples using the developed method. This microextraction-HPLC method demonstrated good linearity (1-500 µg L-1) with a coefficient of determination (R2) of 0.9959-0.9999, low limits of detection (0.06-0.17 µg L-1) and limits of quantification (0.20-0.56 µg L-1), good analyte recoveries (80-96%), and acceptable relative standard deviations (< 10%) under the optimized conditions. The method is systematically compared to those reported in the literature.


Asunto(s)
Antibacterianos/aislamiento & purificación , Impresión Molecular , Polímeros/química , Sefarosa/química , Dióxido de Silicio/química , Sulfonamidas/aislamiento & purificación , Contaminantes Químicos del Agua/aislamiento & purificación , Agua/química , Antibacterianos/química , Geles/química , Tamaño de la Partícula , Sulfonamidas/química , Propiedades de Superficie , Contaminantes Químicos del Agua/química