Commun Med (Lond) ; 2: 3, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35603301

RESUMEN

Background: Tissue-engineered vascular grafts (TEVGs) have the potential to advance the surgical management of infants and children requiring congenital heart surgery by creating functional vascular conduits with growth capacity. Methods: Herein, we used an integrative computational-experimental approach to elucidate the natural history of neovessel formation in a large animal preclinical model; combining an in vitro accelerated degradation study with mechanical testing, large animal implantation studies with in vivo imaging and histology, and data-informed computational growth and remodeling models. Results: Our findings demonstrate that the structural integrity of the polymeric scaffold is lost over the first 26 weeks in vivo, while polymeric fragments persist for up to 52 weeks. Our models predict that early neotissue accumulation is driven primarily by inflammatory processes in response to the implanted polymeric scaffold, but that turnover becomes progressively mechano-mediated as the scaffold degrades. Using a lamb model, we confirm that early neotissue formation results primarily from the foreign body reaction induced by the scaffold, resulting in an early period of dynamic remodeling characterized by transient TEVG narrowing. As the scaffold degrades, mechano-mediated neotissue remodeling becomes dominant around 26 weeks. After the scaffold degrades completely, the resulting neovessel undergoes growth and remodeling that mimicks native vessel behavior, including biological growth capacity, further supported by fluid-structure interaction simulations providing detailed hemodynamic and wall stress information. Conclusions: These findings provide insights into TEVG remodeling, and have important implications for clinical use and future development of TEVGs for children with congenital heart disease.

2.
Curr Drug Saf ; 10(2): 190-2, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25986039

RESUMEN

Sulindac is a long-acting nonsteroidal anti-inflammatory drug (NSAID) widely used for the management of osteoarthritis, rheumatoid arthritis, ankylosing sponydlitis, and acute gouty arthritis. Reports of sulindac toxicity in the literature are rare. We report the case of a 22-year old male with a history of bipolar disorder who was brought to the emergency department after ingesting approximately 15 g of sulindac in a suicide attempt. He was found to have acute kidney injury and hyperbilirubinemia. Despite aggressive fluid resuscitation, his renal function progressively worsened requiring the initiation of hemodialysis. Ten days following ingestion of sulindac, he began to develop ischemic skin changes with a gangrenous appearance in his hands and feet. He continued to receive supportive treatment, and his acute kidney injury, hyperbillirubinemia, and ischemic skin necrosis eventually resolved. Clinicians should be aware of this long-acting NSAID and its ability to cause prolonged multisystem organ dysfunction.


Asunto(s)
Lesión Renal Aguda/inducido químicamente , Antiinflamatorios no Esteroideos/envenenamiento , Sobredosis de Droga , Hiperbilirrubinemia/inducido químicamente , Enfermedades de la Piel/inducido químicamente , Sulindac/envenenamiento , Lesión Renal Aguda/terapia , Trastorno Bipolar/complicaciones , Fluidoterapia , Humanos , Isquemia , Masculino , Necrosis , Diálisis Renal , Resucitación , Piel/irrigación sanguínea , Enfermedades de la Piel/patología , Intento de Suicidio , Adulto Joven
3.
Tissue Eng Part C Methods ; 21(9): 987-94, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25915105

RESUMEN

Decellularized allograft heart valves have been used as tissue-engineered heart valve (TEHV) scaffolds with promising results; however, little is known about the cellular mechanisms underlying TEHV neotissue formation. To better understand this phenomenon, we developed a murine model of decellularized pulmonary heart valve transplantation using a hemodynamically unloaded heart transplant model. Furthermore, because the hemodynamics of blood flow through a heart valve may influence morphology and subsequent function, we describe a modified loaded heterotopic heart transplant model that led to an increase in blood flow through the pulmonary valve. We report host cell infiltration and endothelialization of implanted decellularized pulmonary valves (dPV) and provide an experimental approach for the study of TEHVs using mouse models.


Asunto(s)
Prótesis Valvulares Cardíacas , Válvulas Cardíacas/fisiología , Hemodinámica , Ingeniería de Tejidos/métodos , Animales , Trasplante de Corazón , Válvulas Cardíacas/diagnóstico por imagen , Ventrículos Cardíacos , Ratones Endogámicos C57BL , Modelos Animales , Presión , Válvula Pulmonar/citología , Válvula Pulmonar/fisiología , Ultrasonografía
4.
J Vis Exp ; (89)2014 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-25079013

RESUMEN

Tissue engineered heart valves, especially decellularized valves, are starting to gain momentum in clinical use of reconstructive surgery with mixed results. However, the cellular and molecular mechanisms of the neotissue development, valve thickening, and stenosis development are not researched extensively. To answer the above questions, we developed a murine heterotopic heart valve transplantation model. A heart valve was harvested from a valve donor mouse and transplanted to a heart donor mouse. The heart with a new valve was transplanted heterotopically to a recipient mouse. The transplanted heart showed its own heartbeat, independent of the recipient's heartbeat. The blood flow was quantified using a high frequency ultrasound system with a pulsed wave Doppler. The flow through the implanted pulmonary valve showed forward flow with minimal regurgitation and the peak flow was close to 100 mm/sec. This murine model of heart valve transplantation is highly versatile, so it can be modified and adapted to provide different hemodynamic environments and/or can be used with various transgenic mice to study neotissue development in a tissue engineered heart valve.


Asunto(s)
Prótesis Vascular , Trasplante de Corazón/métodos , Válvula Pulmonar/trasplante , Animales , Femenino , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos , Modelos Animales , Recolección de Tejidos y Órganos/métodos , Trasplante Heterotópico/métodos