Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Comput Assist Tomogr ; 46(4): 633-637, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35483097

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the association between 4-dimensional computed tomography (4DCT)-derived measurements of tibiofibular syndesmosis during active dorsiflexion-plantarflexion motion and the presence of tibiotalar osteoarthritis (OA). METHODS: Sixteen ankle joints underwent 4DCT imaging during active dorsiflexion-plantarflexion. Syndesmotic anterior distance (SAD) and syndesmotic translation (ST) were obtained by a foot-and-ankle surgeon. We used Kellgren-Lawrence (KL) grading to determine tibiotalar OA. RESULTS: Of 16 scanned ankles, 12 ankles had KL ≥2 at the tibiotalar joint. In these ankles, SAD (-0.4, P = 0.02) and ST (-0.9, P = 0.006) measurements significantly changed during the dorsiflexion-plantarflexion motion. Changes in SAD measurements were significantly correlated with the KL grades (correlation coefficient: -0.688, P = 0.003); however, the changes in ST measurements were not significantly correlated with the KL grade. CONCLUSIONS: Our exploratory cross-sectional analysis shows that SAD measurement changes during motion using 4DCT are correlated with the tibiotalar OA grading. This measurement may be used but requires confirmation in larger studies including patients with actual syndesmotic injuries.


Asunto(s)
Articulación del Tobillo , Osteoartritis , Articulación del Tobillo/diagnóstico por imagen , Fenómenos Biomecánicos , Estudios Transversales , Tomografía Computarizada Cuatridimensional , Humanos
2.
Radiology ; 300(1): 110-119, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33876973

RESUMEN

Background Dual-energy CT (DECT) shows promising performance in detecting bone marrow edema (BME) associated with vertebral body fractures. However, the optimal technical and image interpretation parameters are not well described. Purpose To conduct a systematic review and meta-analysis to determine the diagnostic performance of DECT in detecting BME associated with vertebral fractures (VFs), using different technical and image interpretation parameters, compared with MRI as the reference standard. Materials and Methods A systematic literature search was performed on July 9, 2020, to identify studies evaluating DECT performance for in vivo detection of vertebral BME. A random-effects model was used to derive estimates of the diagnostic accuracy parameters of DECT. The impact of relevant covariates in technical, image interpretation, and study design parameters on the diagnostic performance of DECT was investigated using subgroup analyses. Results Seventeen studies (with 742 of 2468 vertebrae with BME at MRI) met inclusion criteria. Pooled estimates of sensitivity, specificity, and area under the curve of DECT for vertebral body BME were 89% (95% CI: 84%, 92%), 96% (95% CI: 92%, 98%), and 96% (95% CI: 94%, 97%), respectively. Single-source consecutive scanning showed poor specificity (78%) compared with the dual-source technique (98%, P < .001). Specificity was higher using bone and soft-tissue kernels (98%) compared with using only soft-tissue kernels (90%, P = .001). Qualitative assessment had a better specificity (97%) versus quantitative assessment (90%) of DECT images (P = .01). Experienced readers showed considerably higher specificity (96%) compared with trainees (79%, P = .01). DECT sensitivity improved using a higher difference between low- and high-energy spectra (90% vs 83%, P = .04). Conclusion Given its high specificity, the detection of vertebral bone marrow edema with dual-energy CT (DECT) associated with vertebral fracture may obviate confirmatory MRI in an emergency setting. Technical parameters, such as the dual-source technique, both bone and soft-tissue kernels, and qualitative assessment by experienced readers, can ensure the high specificity of DECT. © RSNA, 2021 Online supplemental material is available for this article.


Asunto(s)
Enfermedades de la Médula Ósea/complicaciones , Enfermedades de la Médula Ósea/diagnóstico por imagen , Edema/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Fracturas de la Columna Vertebral/complicaciones , Tomografía Computarizada por Rayos X/métodos , Médula Ósea/diagnóstico por imagen , Edema/etiología , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Foot Ankle Surg ; 27(2): 201-206, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32475795

RESUMEN

BACKGROUND: Optimal characterization of Adult acquired flatfoot deformity (AAFD) on two-dimensional radiograph can be challenging. Weightbearing Cone Beam CT (CBCT) may improve characterization of the three-dimensional (3D) structural details of such dynamic deformity. We compared and validated AAFD measurements between weightbearing radiograph and weightbearing CBCT images. METHODS: 20 patients (20 feet, right/left: 15/5, male/female: 12/8, mean age: 52.2) with clinical diagnosis of flexible AAFD were prospectively recruited and underwent weightbearing dorsoplantar (DP) and lateral radiograph as well as weightbearing CBCT. Two foot and ankle surgeons performed AAFD measurements at parasagittal and axial planes (lateral and DP radiographs, respectively). Intra- and Inter-observer reliabilities were calculated by Intraclass correlation (ICC) and Cohen's kappa. Mean values of weightbearing radiograph and weightbearing CBCT measurements were also compared. RESULTS: Except for medial-cuneiform-first-metatarsal-angle, adequate intra-observer reliability (range:0.61-0.96) was observed for weightbearing radiographic measurements. Moderate to very good interobserver reliability between weightbearing radiograph and weightbearing CBCT measurements were observed for the following measurements: Naviculocuneiform-angle (ICC:0.47), Medial-cuneiform-first-metatarsal-gapping (ICC:0.58), cuboid-to-floor-distance (ICC:0.68), calcaneal-inclination-angle(ICC:0.7), axial Talonavicular-coverage-angle(ICC:0.56), axial Talus-first-metatarsal-angle(ICC:0.62). Comparing weightbearing radiograph and weightbearing CBCT images, statistically significant differences in the mean values of parasagittal talus-first-metatarsal-angle, medial-cuneiform-first-metatarsal-angle, medial-cuneiform-to-floor-distance and navicular-to-floor-distance was observed (P < 0.05). CONCLUSION: Moderate to very good correlation was observed between certain weightbearing radiograph and weightbearing CBCT measurements, however, significant difference was observed between a number of AAFD measurements, which suggest that 2D radiographic evaluation could potentially underestimate the severity of AAFD, when compared to 3D weightbearing CT assessment.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Pie Plano/diagnóstico por imagen , Pie Plano/fisiopatología , Soporte de Peso , Adulto , Femenino , Pie Plano/cirugía , Humanos , Masculino , Huesos Metatarsianos , Persona de Mediana Edad , Examen Físico , Estudios Prospectivos , Reproducibilidad de los Resultados , Astrágalo , Adulto Joven
4.
Radiology ; 290(2): 435-445, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30457479

RESUMEN

Purpose To investigate the diagnostic performance of three-dimensional (3D) MRI for depicting meniscal injuries of the knee by using surgery as the standard of reference. Materials and Methods A literature search was performed to identify original studies published between 1985 and 2017. Summary receiver operating characteristic curve and sensitivity analyses were performed to compare the diagnostic performance of 3D versus two-dimensional (2D) MRI for the assessment of knee meniscal injuries and to evaluate the impact of relevant covariates on the diagnostic performance for assessment of knee meniscal injuries. Results Of identified records, 31 studies (1743 3D knee MRI examinations) were included (23 studies also reported the results of 2D MRI). All studies before 2008 used gradient-echo (GRE) sequences, whereas all studies after 2011 used fast spin-echo (FSE) sequences. By comparing FSE and GRE sequences with 2D MRI, pooled estimate of sensitivity (90.0%; P = .2 and 90.1%; P = .2 vs 88.5%) and pooled estimate of specificity (91%; P = .3 and 89.8% vs 90.1%; P = .7) were comparable. The 3D FSE sequences demonstrated similar diagnostic performance as 3D GRE sequences, except for slightly improved sensitivity for depicting lateral meniscal injuries (FSE, 84.6%; GRE, 75%; P = .01). The specificity of 3D sequences improved when multiplanar reformatting was performed (P = .02). Conclusion Both three-dimensional (3D) fast spin-echo (FSE) and 3D gradient-echo (GRE) sequences had similar diagnostic performance as two-dimensional sequences, with slight superior sensitivity of 3D FSE sequences compared with 3D GRE sequences for depicting lateral meniscal injuries of the knee. © RSNA, 2018 Online supplemental material is available for this article.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Meniscos Tibiales/diagnóstico por imagen , Lesiones de Menisco Tibial/diagnóstico por imagen , Adulto , Humanos , Masculino , Adulto Joven
5.
J Magn Reson Imaging ; 50(5): 1545-1560, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-30950549

RESUMEN

BACKGROUND: Despite the advantages of 3D MRI in evaluation of cruciate ligament injuries, its use in clinical practice is still a matter of debate due to controversy regarding its diagnostic performance. PURPOSE: To evaluate the diagnostic performance of 3D MRI for detecting cruciate ligament injuries, using surgery or arthroscopy as the reference standard. STUDY TYPE: Meta-analysis. POPULATION: Patients with knee pain. FIELD STRENGTH/SEQUENCE: 3D and 2D MRI. ASSESSMENT: Four databases were reviewed according to PRISMA guidelines. STATISTICAL TESTS: Pooled values of sensitivity, specificity, and diagnostic odds ratio (DOR) were calculated using a random-effects model. To investigate the effect of relevant covariates on the diagnostic performance of 3D MRI, sensitivity analysis was performed using meta-regression to calculate relative DOR. RESULTS: Of 731 initially identified reports, 22 (1298 3D MRI examinations) met our criteria and were included. Pooled estimates of sensitivity and specificity for 3D sequences were 91.4% (95% confidence interval [CI]: 87.4-94.2%) and 96.1% (95% CI: 93.8-97.6%), respectively. Fourteen studies also reported the results of 2D MRI, with pooled sensitivity of 90.6% (95% CI: 84.1-94.6%) and specificity of 97.1% (95% CI: 94.7-98.4%), which were not significantly different from 3D sequences. 3D MRI sequences performed using 3T scanners had significantly higher DOR compared with 3D sequences performed on 1.5T or lower scanners (relative DOR: 6.04, P = 0.01). DATA CONCLUSION: 3D MRI is equivalent to 2D MRI in the diagnosis of cruciate ligament injuries. The use of 3T scanners improves the performance of 3D MRI for detecting cruciate ligament injuries. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1545-1560.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior/diagnóstico por imagen , Artroscopía , Imagenología Tridimensional , Traumatismos de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética , Área Bajo la Curva , Bases de Datos Factuales , Humanos , Rodilla/diagnóstico por imagen , Oportunidad Relativa , Dolor , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
J Comput Assist Tomogr ; 43(3): 392-398, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30762658

RESUMEN

PURPOSE: The aim of this study was to determine the normal measurement values and interobserver performance of the distal radioulnar joint during wrist pronation-supination using 4-dimensional computed tomography (CT). METHODS: Four-dimensional CT examinations were performed on the asymptomatic contralateral wrists of 10 patients with unilateral chronic wrist pain. Measurements were conducted using the modified radioulnar (mRU) line and epicenter (Epi) methods. Volar subluxation of the ulnar head was demonstrated with negative values. Wilcoxon rank sum test was used to determine the measurement changes. Interobserver agreements were assessed using interclass correlation coefficients. RESULTS: In pronation, mRU line measurements (median, 0.09; interquartile range, 0-0.15) were significantly larger than in supination (median, -0.1; interquartile range, -0.18 to 0; P = 0.008).The Epi measurements were not significantly different in pronation (median, 0.03; interquartile range, 0.01-0.07) and supination (median, 0.06; interquartile range, 0.01-0.1; P = 0.799). There was an excellent inter-observer agreement between the two readers using mRU and Epi methods in pronation (0.982, 0.898), midpoint (0.994, 0.827) and supination (0.989, 0.972) positions, respectively. CONCLUSIONS: Using 4-dimensional CT examination, distal radioulnar joint kinematics in asymptomatic wrists demonstrate excellent interobserver agreements with increased volar ulnar subluxation with supination as detected using mRU, but not the Epi method.


Asunto(s)
Tomografía Computarizada Cuatridimensional/métodos , Articulación de la Muñeca/diagnóstico por imagen , Articulación de la Muñeca/fisiología , Adolescente , Adulto , Fenómenos Biomecánicos , Femenino , Tomografía Computarizada Cuatridimensional/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Adulto Joven
7.
Skeletal Radiol ; 48(12): 1999-2007, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31172206

RESUMEN

OBJECTIVES: To evaluate the improvement in extremity cone-beam computed tomography (CBCT) image quality in datasets with motion artifact using a motion compensation method based on maximizing image sharpness. METHODS: Following IRB approval, retrospective analysis of 308 CBCT scans of lower extremities was performed by a fellowship-trained musculoskeletal radiologist to identify images with moderate to severe motion artifact. Twenty-four scans of 22 patients (18 male, four female; mean, 32 years old, range, 21-74 years old) were chosen for inclusion. Sharp (bone) and smooth (soft tissue) reconstructions were processed using the motion compensation algorithm. Two experts rated visualization of trabecular bone, cortical bone, joint spaces, and tendon on a nine-level Likert scale with and without motion compensation (a total of 96 datasets). Visual grading characteristics (VGC) was used to quantitatively determine the difference in image quality following motion compensation. Intra-class correlation coefficient (ICC) was obtained to assess inter-observer agreement. RESULTS: Motion-compensated images exhibited appreciable reduction in artifacts. The observer study demonstrated the associated improvement in diagnostic quality. The fraction of cases receiving scores better than "Fair" increased from less than 10% without compensation to 40-70% following compensation, depending on the task. The area under the VGC curve was 0.75 (tendon) to 0.85 (cortical bone), confirming preference for motion compensated images. ICC values showed excellent agreement between readers before (ICC range, 0.8-0.91) and after motion compensation (ICC range, 0.92-0.97). CONCLUSIONS: The motion compensation algorithm significantly improved the visualization of bone and soft tissue structures in extremity CBCT for cases exhibiting patient motion.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Extremidad Inferior/diagnóstico por imagen , Adulto , Anciano , Algoritmos , Artefactos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos
8.
Skeletal Radiol ; 48(4): 583-594, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30242446

RESUMEN

OBJECTIVE: To evaluate the influence of weight-bearing (WB) load in standard axial ankle syndesmotic measurements using cone beam CT (CBCT) examination of asymptomatic uninjured ankles. MATERIALS AND METHODS: In this IRB approved, prospective study, patients with previous unilateral ankle fractures were recruited. We simultaneously scanned the injured ankles and asymptomatic contralateral ankles of 27 patients in both WB and NWB modes. For this study, only asymptomatic contralateral ankles with normal plain radiographs were included. Twelve standardized syndesmosis measurements at two axial planes (10 mm above the tibial plafond and 5 mm below the talar dome) were obtained by two expert readers using a custom CBCT viewer with the capability for geometric measurements between user-identified anatomical landmarks. Inter-reader reliability between two readers was obtained using the intra-class correlation coefficient (ICC). We compared the WB and NWB measurements using paired t test. RESULTS: Significant agreement was observed between two readers for both WB and NWB measurements (p <0.05). ICC values for WB and NWB measurements had a range of 50-95 and 31-71 respectively. Mean values of the medial clear space on WB images (1.75, 95% confidence interval [95% CI]: 1.6, 1.9) were significantly lower than on NWB images (2.05, 95% CI: 1.8, 2.2) measurements (p <0.001). There was no significant difference between the remaining WB and NWB measurements. CONCLUSION: Measurements obtained from WB images are reliable. Except for the medial clear space, no significant difference in syndesmotic measurements were observed during the WB mode of CBCT acquisition, implying that the tibio-fibular relationship remains unchanged when the physiological axial weight-bearing load is applied.


Asunto(s)
Articulación del Tobillo/diagnóstico por imagen , Articulación del Tobillo/fisiopatología , Tomografía Computarizada de Haz Cónico , Soporte de Peso/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
9.
Foot Ankle Surg ; 25(6): 790-797, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30455094

RESUMEN

BACKGROUND: Clinical assessment of hindfoot alignment (HA) in adult acquired flatfoot deformity (AAFD) can be challenging and weightbearing (WB) cone beam CT (CBCT) may potentially better demonstrate this three-dimensional (3D) deformity. Therefore, we compared clinical and WB CBCT assessment of HA in patients with AAFD. METHODS: In this prospective study, we included 12 men and 8 women (mean age: 52.2, range: 20-88) with flexible AAFD. All subjects also underwent WB CBCT and clinical assessment of hindfoot alignment. Three fellowship-trained foot and ankle surgeons performed six hindfoot alignment measurements on the CT images. Intra- and Inter-observer reliabilities were calculated using intra-class correlation (ICC). Measurements were compared by paired T-tests, and p-values of less than 0.05 were considered significant. RESULTS: The mean of clinically measured hindfoot valgus was 15.2 (95% confidence interval [CI]: 11.5-18.8) degrees. It was significantly different from the mean values of all WB CBCT measurements: Clinical Hindfoot Alignment Angle, 9.9 (CI: 8.9-11.1) degrees; Achilles tendon/Calcaneal Tuberosity Angle, 3.2 (CI: 1.3-5.0) degrees; Tibial axis/Calcaneal Tuberosity Angle, 6.1 (CI: 4.3-7.8) degrees; Tibial axis/Subtalar Joint Angle 7.0 (CI: 5.3-8.8) degrees, and Hindfoot Alignment Angle 22.8 (CI: 20.4-25.3) degrees. We found overall substantial to almost perfect intra- (ICC range: 0.87-0.97) and inter-observer agreements (ICC range: 0.51-0.88) for all WB CBCT measurements. CONCLUSIONS: Using 3D WB CBCT can help characterize the valgus hindfoot alignment in patients with AAFD. We found the different CT measurements to be reliable and repeatable, and to significantly differ from the clinical evaluation of hindfoot valgus alignment. LEVEL OF EVIDENCE: Level II-prospective comparative study.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Pie Plano/diagnóstico , Deformidades Adquiridas del Pie/diagnóstico , Pie/diagnóstico por imagen , Examen Físico , Soporte de Peso , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
10.
Foot Ankle Surg ; 25(4): 495-502, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30321961

RESUMEN

BACKGROUND: Our purpose was to assess the reliability of measurements of adult-acquired flatfoot deformity (AAFD) taken by investigators of different levels of clinical experience using weightbearing computed tomography (WBCT). METHODS: Nineteen AAFD patients underwent WBCT. Three investigators with different levels of clinical experience made AAFD measurements in axial, coronal, and sagittal planes. Intra- and interobserver reliability were assessed. Mean values for each measurement were compared between investigators. RESULTS: After a training protocol, substantial to perfect intra- and interobserver reliability was observed for most measures, regardless of the investigator's experience level. Significant differences between investigators were observed in 2 of 21 measured parameters: medial cuneiform-first metatarsal angle (P=0.003) and navicular-medial cuneiform angle (P=0.001). CONCLUSIONS: AAFD radiographic measurements can be performed reliably by investigators with different levels of clinical experience using WBCT. LEVEL OF EVIDENCE: Level II, prospective comparative study.


Asunto(s)
Competencia Clínica , Pie Plano/diagnóstico por imagen , Soporte de Peso , Adulto , Pesos y Medidas Corporales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
11.
Foot Ankle Surg ; 25(6): 771-781, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30442425

RESUMEN

BACKGROUND: To investigate the reliability and reproducibility of syndesmosis measurements on weightbearing (WB) cone-beam computed tomography (CBCT) images and compare them with measurements obtained using non-weightbearing (NWB) images. METHODS: In this IRB-approved, retrospective study of 5 men and 9 women with prior ankle injuries, simultaneous WB and NWB CBCT scans were taken. A set of 21 syndesmosis measurements using WB and NWB images were performed by 3 independent observers. Pearson/Spearman correlation and intra-class correlation (ICC) were used to assess intra- and inter-observer reliability, respectively. RESULTS: We observed substantial to perfect intra-observer reliability (ICC=0.72-0.99) in 20 measurements. Moderate to perfect agreement (ICC=0.45-0.97) between observers was noted in 19 measurements. CONCLUSION: Measurements evaluating the distance between tibia and fibula in the axial plane 10mm above the plafond had high intra- and inter-observer reliability. Mean posterior tibio-fibular distance, diastasis, and angular measurement were significantly different between WB and NWB images.


Asunto(s)
Articulación del Tobillo/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico , Inestabilidad de la Articulación/diagnóstico por imagen , Soporte de Peso/fisiología , Adulto , Anciano , Traumatismos del Tobillo/fisiopatología , Articulación del Tobillo/fisiopatología , Diástasis Ósea/diagnóstico por imagen , Diástasis Ósea/fisiopatología , Femenino , Humanos , Inestabilidad de la Articulación/fisiopatología , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Rotación , Adulto Joven
12.
Radiology ; 289(1): 71-82, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30015587

RESUMEN

Purpose To determine the diagnostic performance of three-dimensional (3D) MRI for the depiction and characterization of cartilage defects within the knee joint by using arthroscopy and/or open surgery as the standard of reference. Materials and Methods A systematic literature search was performed to extract diagnostic studies published between January 1985 and October 2017. Two independent investigators assessed the methodologic quality of each study by using Quality Assessment of Diagnostic Accuracy Studies 2. Bivariate random-effects model was used to compare the diagnostic odds ratio (DOR) of 3D and two-dimensional (2D) MRI for helping to detect knee cartilage defects and to assess the effect of relevant covariates on diagnostic performance of 3D MRI. Meta-regression analysis was performed to assess DOR of 3D MRI during the last 3 decades. Results Twenty-seven studies (composed of 1710 MRI examinations) were included. Of those, 16 (59%) studies compared the diagnostic performance of 3D and 2D MRI. The diagnostic performance of 3D MRI statistically significantly improved over the last 3 decades (P = .003). Three-dimensional MRI obtained by using 3.0-T field strength had higher DOR relative to 1.5-T or lower field strength (relative DOR, 4.05; P = .01). Three-dimensional multiplanar reformation was associated with higher specificity (P = .001) compared with conventional axial, sagittal, and coronal 2D MRI planes. Three-dimensional fast-spin-echo sequences provided higher sensitivity and specificity (P < .05) than did 2D MRI. Conclusion Three-dimensional MRI currently provides comparable diagnostic performance to two-dimensional MRI, with improvement in diagnostic performance achieved by using 3.0-T field strength, three-dimensional fast-spin-echo sequences, and multiplanar reformation. © RSNA, 2018 Online supplemental material is available for this article.


Asunto(s)
Enfermedades de los Cartílagos/diagnóstico por imagen , Imagenología Tridimensional/estadística & datos numéricos , Articulación de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Cartílago Articular/diagnóstico por imagen , Humanos , Persona de Mediana Edad , Oportunidad Relativa , Estudios Retrospectivos , Adulto Joven
13.
AJR Am J Roentgenol ; 211(1): W52-W63, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29792743

RESUMEN

OBJECTIVE: The purpose of this study is to determine the diagnostic performance of MRI and MR arthrography for depicting ligamentum teres lesions. MATERIALS AND METHODS: A literature search was performed. Original studies reporting the diagnostic accuracy of MRI examinations for the depiction of ligamentum teres lesions were included. RESULTS: Eight studies entailing 1456 MRI examinations were included (frequency of median ligamentum teres injury, 25.9%; interquartile range, 14.1-45.3%). Two studies reported the results of unenhanced MRI examinations, and their diagnostic performance could not be estimated. Sensitivity, specificity, and diagnostic odds ratio (DOR) of all MRI examinations were 64.7%, 86.9%, and 12.2, respectively, whereas the sensitivity, specificity, and DOR of MR arthrography examinations were 82.2%, 88.6%, and 35.9, respectively. The heterogeneity (I2) for all MRI and MR arthrography examinations was 92.3% and 88.2%, respectively. Five blinded MR arthrography studies with 643 MR arthrography examinations found an appropriate threshold effect for summary ROC construction (AUC, 0.95). The summary estimate of these studies yielded a sensitivity of 87.8%, a specificity of 91%, and DOR of 73.1. The heterogeneity (I2) for this group was 64.3%. In patients with low pretest probability (25%), MR arthrography enabled the exclusion of ligamentum teres lesion (postprobability for a negative result, 4%; negative likelihood ratio, 0.13). CONCLUSION: MR arthrography can depict ligamentum teres lesions with high accuracy. However, its diagnostic performance for differentiating various types of ligamentum teres lesions (partial, complete ligamentum teres tears, and hypertrophic ligamentum teres), as well as the diagnostic performance of unenhanced MRI for the depiction of ligamentum teres lesions, is yet to be determined because of the paucity of reported data in the literature.


Asunto(s)
Articulación de la Cadera/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Ligamentos Redondos/diagnóstico por imagen , Diagnóstico Diferencial , Articulación de la Cadera/patología , Humanos , Ligamentos Redondos/patología , Sensibilidad y Especificidad
14.
Emerg Med J ; 32(7): 516-9, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25147364

RESUMEN

BACKGROUND: Numerous drugs have been proposed to alleviate ischaemic limb pain, but none have been successful in relieving ischaemic pain thoroughly and rapidly. OBJECTIVE: To compare the effectiveness of intravenous lidocaine and intravenous morphine in decreasing pain in patients with critical limb ischaemia. METHODS: A randomised double-blind controlled trial was performed in 63 patients with critical limb ischaemia recruited from the emergency department between October 2012 and December 2013; 23 patients were excluded and the remainder were randomly divided into two groups of 20 patients. Patients in the lidocaine group received lidocaine infusion (2 mg/kg) while patients in the morphine group received morphine (0.1 mg/kg). Patients' visual analogue pain scores (VAS), from 0 to 10, were reported before and 15 and 30 min after the infusion. RESULTS: Before the infusion the mean±SD VAS score was 7.50±1.93 in the lidocaine group and 7.65±1.92 in the morphine group. At 15 min the mean±SD VAS score in the lidocaine group was lower than in the morphine group (5.75±1.77 vs 7.00±1.83; mean difference 1.25, 95% CI 0.095 to 2.405) and, at 30 min, the mean±SD VAS score in the lidocaine group was again lower (4.25±1.48 vs 6.50±1.73; mean difference 2.25, 95% CI 1.218 to 3.282). CONCLUSIONS: Lidocaine may be helpful in decreasing ischaemic pain in patients with critical limb ischaemia. TRIAL REGISTRATION NUMBER: http://www.irct.irIRCT201210148872N2.


Asunto(s)
Analgésicos Opioides/administración & dosificación , Extremidades/irrigación sanguínea , Isquemia/complicaciones , Lidocaína/administración & dosificación , Morfina/administración & dosificación , Dolor/tratamiento farmacológico , Administración Intravenosa , Adulto , Anciano , Enfermedad Crítica , Método Doble Ciego , Servicio de Urgencia en Hospital/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dolor/etiología , Dimensión del Dolor
15.
Clin Imaging ; 101: 133-136, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37331151

RESUMEN

The goal of this study was to perform a pilot study to assess user-interface of radiologists with an artificial-intelligence (AI) centric workflow for detection of intracranial hemorrhage (ICH) and cervical spine fractures (CSFX). Over 12-month period, interaction and usage of AI software implemented in our institution, Aidoc, on head and cervical spine CT scans were obtained. Several interaction variables were defined, assessing different types of interaction between readers of different training level and AI software. The median usage of AI-centric workflow for detection of ICH and CSFX were 28.8% and 21.8%, respectively, demonstrating a significant additional engagement beyond Native workflow (worklist and PACS). Further studies are warranted to expand interaction assessments to further understand the value unlocked by the AI-centric workflows.


Asunto(s)
Inteligencia Artificial , Fracturas de la Columna Vertebral , Humanos , Flujo de Trabajo , Urgencias Médicas , Proyectos Piloto , Programas Informáticos
16.
Invest Radiol ; 58(1): 99-110, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-35976763

RESUMEN

ABSTRACT: Although musculoskeletal magnetic resonance imaging (MRI) plays a dominant role in characterizing abnormalities, novel computed tomography (CT) techniques have found an emerging niche in several scenarios such as trauma, gout, and the characterization of pathologic biomechanical states during motion and weight-bearing. Recent developments and advancements in the field of musculoskeletal CT include 4-dimensional, cone-beam (CB), and dual-energy (DE) CT. Four-dimensional CT has the potential to quantify biomechanical derangements of peripheral joints in different joint positions to diagnose and characterize patellofemoral instability, scapholunate ligamentous injuries, and syndesmotic injuries. Cone-beam CT provides an opportunity to image peripheral joints during weight-bearing, augmenting the diagnosis and characterization of disease processes. Emerging CBCT technologies improved spatial resolution for osseous microstructures in the quantitative analysis of osteoarthritis-related subchondral bone changes, trauma, and fracture healing. Dual-energy CT-based material decomposition visualizes and quantifies monosodium urate crystals in gout, bone marrow edema in traumatic and nontraumatic fractures, and neoplastic disease. Recently, DE techniques have been applied to CBCT, contributing to increased image quality in contrast-enhanced arthrography, bone densitometry, and bone marrow imaging. This review describes 4-dimensional CT, CBCT, and DECT advances, current logistical limitations, and prospects for each technique.


Asunto(s)
Enfermedades de la Médula Ósea , Gota , Humanos , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada de Haz Cónico/métodos , Imagen por Resonancia Magnética/métodos , Edema
17.
J Clin Orthop Trauma ; 34: 102042, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36263249

RESUMEN

Background: To determine the mid-term outcomes of conventional cementless Total Hip Arthroplasty (THA) in patients with avascular necrosis (AVN) of the femoral head and compare to patients with primary hip osteoarthritis (OA). Method: A total of 330 consecutive primary THA procedures (AVN and OA) performed between 2010 and 2013 by a single surgeon and in a single center using the direct anterior approach (DAA) were included. Assessments including SF-36, WOMAC, and Harris Hip Scores (HHS) were retrieved from patients before the surgery and at the latest follow-up. Clinical and functional outcomes were compared between the AVN and OA groups. Results: A total of 294 consecutive THA (AVN = 107, OA = 187) with 104.4 ± 6.2 months follow-up were analyzed, which AVN patients were significantly younger (32.0 vs. 59.6 y/o). Corticosteroid 34 (31.8%), idiopathic AVN 31 (29.0%) and use of unapproved weight gain supplements (UWGS) 23 (21.5%) were the main reasons for AVN. Despite that preoperative scores were comparable (P > 0.05), the HHS, SF-36, and WOMAC scores are significantly higher in the AVN group after THA surgery (P < 0.05). Moreover, flexion and abduction ROM were significantly higher in the AVN group (P < 0.05). Regarding each complication, no significant difference was observed between groups. In the whole sample, there were 5 (1.7%) revisions due to loosening of acetabular components, all the OA group (P > 0.05). Conclusion: Conventional cementless THA with highly cross-linked polyethylene provides satisfactory mid-term results in patients with AVN with a low rate of postoperative complications. Compared to primary OA patients, this group reaches superior postoperative scores.

18.
Int J Ophthalmol ; 14(8): 1225-1230, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34414088

RESUMEN

AIM: To compare outcomes of applying preservative free artificial tears (PFAT) with and without hyaluronic acid (HA) in early postoperative course following photorefractive keratectomy (PRK). METHODS: In this triple-blinded randomized clinical trial, PRK procedure was performed on both eyes of 230 patients. Following PRK, patients were divided into three groups: the HA+ group, 44 patients PFAT containing HA; the HA- group, 71 patients PFAT without HA were administered 5 times per day (every 4h); the third group, 115 patients received no PFAT before lens removal. On the 1st and 4th postoperative day, Visual Analogue Score (VAS) was utilized to evaluate patient's level of pain. Participants were asked to complete a questionnaire about the severity of eye discomfort ranked from 0 to 10 (0=no complaint; 10=most severe complaint experienced). RESULTS: In eyes receiving PFAT with or without HA (Drop group), mean scores for epiphora, foreign body sensation, and blurred vision on the 1st postoperative day were statistically lower (P<0.05). Filamentous keratitis (FK) was detected in 11 (4.7%) eyes, and recurrent corneal erosion (RCE) was observed in 5 (2.1%) eyes. In the control group, FK was noted in 16 (6.9%) eyes while 13 (5.6%) eyes had RCE and 5 (2.1%) eyes had corneal haze. The rate of complications was statistically lower in Drop group (P=0.009). However, the aforementioned scores were not statically different between HA+ and HA- group one and two (P=0.29). CONCLUSION: Following PRK, applying PFAT with and without HA yields faster visual recovery, decreases postoperative ocular discomfort and haze formation; however there is no additive effect for HA.

19.
Endosc Int Open ; 8(3): E281-E290, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32118102

RESUMEN

Background and study aims Endoscopic stent placement is used for palliative management of unresectable malignant hilar obstruction, which could be achieved by either unilateral or bilateral stent insertion. Materials and methods A literature search was performed to identify studies that reported outcomes of metallic biliary stent placement in patients with malignant hilar obstruction. Weighted pooled rates (WPR) along with 95 % confidence intervals (95 %CI) were calculated to determine and compare outcomes including technical and functional success, early and late adverse events, post procedure cholangitis, and stent occlusion between two groups. Results A total of 21 studies with 1292 patients were included. WPR of technical success was significantly higher in the unilateral group (97 %, 95 %CI: 93 -98 %) vs. bilateral group (89 %, 95 %CI: 84 -92 %) ( P  = 0.0.003). WPR for functional success in the unilateral and bilateral groups were 96 % (95 %CI: 91 -98 %) and 94 % (95 %CI: 91 -97 %), respectively ( P  = 0.48). The rate of early and late complications was comparable between the two groups. Conclusion In patients with unresectable malignant hilar obstruction, unilateral and bilateral metallic stenting techniques are comparable in terms of efficacy and safety.

20.
Endosc Int Open ; 7(3): E322-E329, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30842971

RESUMEN

Background and aim Clinical management of patients with gastroparesis is challenging. Prior pyloric targeted procedures are either invasive or have questionable long-term efficacy. Gastric per-oral endoscopic myotomy (G-POEM) has been recently introduced as a minimally invasive approach. In this review, we performed a meta-analysis to evaluate the feasibility and efficacy of this technique in the management of patients with refractory gastroparesis. Methods PubMed, Embase, and Scopus databases were searched to identify relevant studies published through May 2018. Weighted pool rates (WPR) of the clinical resolution were calculated. Pooled values of Gastroparesis Cardinal Symptom Index (GCSI) before and after the procedure were compared. Pooled difference in means comparing gastric emptying before and after the procedure was calculated. Fixed or random effect model was used according to the level of heterogeneity. Results Seven studies with 196 patients were included in the meta-analysis. The mean value of procedure duration was 69.7 (95 % confidence interval [95 % CI]: 39 - 99 minutes) and average estimate of hospital stay was 1.96 (95 % CI: 1.22 - 2.95) days. The WPR for clinical success was 82 % (95 % CI: 74 % - 87 %, I 2  = 0). Compared with pre-procedure GCSI values, mean values of GCSI were reduced significantly at 5 days (-1.57 (95 % CI:-2.2,-0.9), I 2  = 80 %) ( P  < 0.001). Mean values of gastric emptying were significantly decreased 2 - 3 months after the procedure (-22.3 (95 %CI: -32.9, - 11.6), I 2  = 67 %) ( P  < 0.05). Conclusion Due to the high rate of clinical success and low rate of adverse events, G-POEM should be considered in management of refractory gastroparesis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA