Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Sep Sci ; 37(15): 1937-43, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24824418

RESUMEN

The synthesis and chromatographic behavior of an analytical size mixed-mode bonded silica monolith was investigated. The monolith was functionalized by an in situ modification process of a bare silica rod with chloro(3-cyanopropyl)dimethyl silane and chlorodimethyl propyl phenyl silane solutions. These ligands were selected in order to combine both resonance and nonresonance π-type bonding within a single separation environment. Selectivity studies were undertaken using n-alkyl benzenes and polycyclic aromatic hydrocarbons in aqueous methanol and acetonitrile mobile phases to assess the methylene and aromatic selectivities of the column. The results fit with the linear solvent strength theory suggesting excellent selectivity of the column was achieved. Comparison studies were performed on monolithic columns that were functionalized separately with cyano and phenyl ligands, suggesting highly conjugated molecules were able to successfully exploit both of the π-type selectivities afforded by the two different ligands on the mixed-mode column.

2.
J Sep Sci ; 32(22): 3880-9, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19882627

RESUMEN

C1 and phenyl-type stationary phases were assessed in terms of their environmental impact on separations using as test solutes polycyclic aromatic hydrocarbons. Methanol (MeOH) and acetonitrile (ACN) mobile-phase gradients were employed. These stationary phases were examined to determine if different physical and chemical properties possessed by these surfaces decreased the organic solvent consumption, and yet maintained peak capacity. The cumulative energy demand (CED) was used to gauge the environmental impact of the separations. The separation of the polycyclic aromatic hydrocarbon test mixture using current methodologies (i.e. a C18/ACN combination) had a CED of 1.13 MJ-eq, and a peak capacity of 27 peaks (resolving 7 of 12 peak pairs with R(s)>1). In comparison, a butyl phenyl stationary phase with a methanol mobile phase had a peak capacity of 26, but with a CED of 0.670 MJ-eq. Monolithic columns containing C18 and C1 phases were also tested. A monolithic C18 column with MeOH had the lowest CED at 0.675 MJ-eq, a peak capacity of 28 peaks and good resolving power (resolving ten peak pairs with R(s)>1), suggesting that this is a viable option with respect to reducing environmental impact for these types of analyses.


Asunto(s)
Cromatografía de Afinidad/métodos , Compuestos Policíclicos/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA