Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
J Synchrotron Radiat ; 31(Pt 3): 508-516, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38530832

RESUMEN

Coherent X-ray imaging is an active field at synchrotron sources. The images rely on the available coherent flux over a limited field of view. At many synchrotron beamlines a double-crystal monochromator (DCM) is employed in a standard nondispersive arrangement. For coherent diffraction imaging it is advantageous to increase the available field of view by increasing the spatial coherence length (SCL) of a beam exiting such a DCM. Here, Talbot interferometry data together with ray-tracing simulations for a (+ - - +) four-reflection experimental arrangement are presented, wherein the first two reflections are in the DCM and the final fourth reflection is asymmetric at grazing exit. Analyses of the interferometry data combined with the simulations show that compared with the beam exiting the DCM a gain of 76% in the SCL was achieved, albeit with a factor of 20 reduction in flux density, which may not be a severe penalty at a synchrotron beamline. Previous efforts reported in the literature to increase the SCL that employed asymmetric crystal diffraction at grazing incidence are also discussed. A much reduced SCL is found presently in simulations wherein the same asymmetric crystal is set for grazing incidence instead of grazing exit. In addition, the present study is compared and contrasted with two other means of increasing the SCL. These are (i) focusing the beam onto an aperture to act as a secondary source, and (ii) allowing the beam to propagate in vacuum an additional distance along the beamline.

2.
J Synchrotron Radiat ; 31(Pt 4): 751-762, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38904936

RESUMEN

A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation. CBXFEL cavities require low-loss wavefront-preserving optical components: near-100%-reflectivity X-ray diamond Bragg-reflecting crystals, outcoupling devices such as thin diamond membranes or X-ray gratings, and aberration-free focusing elements. In the framework of the collaborative CBXFEL research and development project of Argonne National Laboratory, SLAC National Accelerator Laboratory and SPring-8, we report here the design, manufacturing and characterization of X-ray optical components for the CBXFEL cavity, which include high-reflectivity diamond crystal mirrors, a diamond drumhead crystal with thin membranes, beryllium refractive lenses and channel-cut Si monochromators. All the designed optical components have been fully characterized at the Advanced Photon Source to demonstrate their suitability for the CBXFEL cavity application.

3.
Pestic Biochem Physiol ; 200: 105807, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38582579

RESUMEN

Recently, nanotechnology is among the most promising technologies used in all areas of research. The production of metal nanoparticles using plant parts has received significant attention for its environmental friendliness and effectiveness. Therefore, we investigated the possible applications of biological synthesized nickel oxide nanoparticles (NiONPs). In this study, NiONPs were synthesized through biological method using an aqueous extract of saffron stigmas (Crocus sativus L). The structure, morphology, purity, and physicochemical properties of the obtained NPs were confirmed through Scanning/Transmission Electron Microscopy attached with Energy Dispersive Spectrum, X-ray Diffraction, and Fourier transform infrared. The spherically shaped NiONPs were found by Debye Scherer's formula to have a mean dimension of 41.19 nm. The application of NiONPs in vitro at 50, 100, and 200 µg/mL, respectively, produced a clear region of 2.0, 2.2, and 2.5 cm. Treatment of Xoo cell with NiONPs reduced the growth and biofilm formation, respectively, by 88.68% and 83.69% at 200 µg/mL. Adding 200 µg/mL NiONPs into Xoo cells produced a significant amount of ROS in comparison with the control. Bacterial apoptosis increased dramatically from 1.05% (control) to 99.80% (200 µg/mL NiONPs). When compared to the control, rice plants treated with 200 µg/mL NiONPs significantly improved growth characteristics and biomass. Interestingly, the proportion of diseased leaf area in infected plants with Xoo treated with NiONPs reduced to 22% from 74% in diseased plants. Taken together, NiONPs demonstrates its effectiveness as a promising tool as a nano-bactericide in managing bacterial infection caused by Xoo.


Asunto(s)
Nanopartículas del Metal , Níquel , Oryza , Xanthomonas , Oryza/microbiología , Enfermedades de las Plantas/prevención & control , Enfermedades de las Plantas/microbiología
4.
J Synchrotron Radiat ; 30(Pt 5): 902-909, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37610344

RESUMEN

The mutual optical intensity (MOI) model is a partially coherent radiation propagation tool that can sequentially simulate beamline optics and provide beam intensity, local degree of coherence and phase distribution at any location along a beamline. This paper extends the MOI model to non-ideal two-dimensional (2D) optical systems, such as ellipsoidal and toroidal mirrors with 2D figure errors. Simulation results show that one can tune the trade-off between calculation efficiency and accuracy by varying the number of wavefront elements. The focal spot size of an ellipsoidal mirror calculated with 100 × 100 elements gives less than 0.4% deviation from that with 250 × 250 elements, and the computation speed is nearly two orders of magnitude faster. Effects of figure errors on 2D focusing are also demonstrated for a non-ideal ellipsoidal mirror and by comparing the toroidal and ellipsoidal mirrors. Finally, the MOI model is benchmarked against the multi-electron Synchrotron Radiation Workshop (SRW) code showing the model's high accuracy.

5.
J Synchrotron Radiat ; 30(Pt 1): 57-64, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36601926

RESUMEN

Adaptive X-ray mirrors are being adopted on high-coherent-flux synchrotron and X-ray free-electron laser beamlines where dynamic phase control and aberration compensation are necessary to preserve wavefront quality from source to sample, yet challenging to achieve. Additional difficulties arise from the inability to continuously probe the wavefront in this context, which demands methods of control that require little to no feedback. In this work, a data-driven approach to the control of adaptive X-ray optics with piezo-bimorph actuators is demonstrated. This approach approximates the non-linear system dynamics with a discrete-time model using random mirror shapes and interferometric measurements as training data. For mirrors of this type, prior states and voltage inputs affect the shape-change trajectory, and therefore must be included in the model. Without the need for assumed physical models of the mirror's behavior, the generality of the neural network structure accommodates drift, creep and hysteresis, and enables a control algorithm that achieves shape control and stability below 2 nm RMS. Using a prototype mirror and ex situ metrology, it is shown that the accuracy of our trained model enables open-loop shape control across a diverse set of states and that the control algorithm achieves shape error magnitudes that fall within diffraction-limited performance.

6.
J Synchrotron Radiat ; 30(Pt 6): 1100-1107, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37815375

RESUMEN

The advent of next-generation synchrotron radiation sources and X-ray free-electron lasers calls for high-quality Bragg-diffraction crystal optics to preserve the X-ray beam coherence and wavefront. This requirement brings new challenges in characterizing crystals in Bragg diffraction in terms of Bragg-plane height errors and wavefront phase distortions. Here, a quantitative methodology to characterize crystal optics using a state-of-the-art at-wavelength wavefront sensing technique and statistical analysis is proposed. The method was tested at the 1-BM-B optics testing beamline at the Advanced Photon Source for measuring silicon and diamond crystals in a self-referencing single-crystal mode and an absolute double-crystal mode. The phase error sensitivity of the technique is demonstrated to be at the λ/100 level required by most applications, such as the characterization of diamond crystals for cavity-based X-ray free-electron lasers.

7.
Opt Express ; 31(2): 2977-2988, 2023 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-36785299

RESUMEN

In a full-field transmission X-ray microscopy (TXM) setup, a condenser X-ray optical element is used to illuminate the sample by condensing the X-ray beam delivered by the synchrotron storage ring. On-going and future upgrades of synchrotron facilities to diffraction-limited storage rings will pose new challenges to these TXM setups, such as much smaller X-ray beams on the condenser. Here, we demonstrate that a refractive axicon can be used as an X-ray beam shaper to match the ring-shaped aperture of the condenser. Aiming at more efficient use of the incoming X-ray intensity, we explore several axicon designs both analytically and with numerical simulations. The axicons were produced by two-photon polymerization 3D printing on thin silicon nitride membrane substrates. The first characterization of the axicon was carried out at the TOMCAT beamline of the Swiss Light Source (Switzerland).

8.
Opt Express ; 31(13): 21264-21279, 2023 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-37381230

RESUMEN

A neural-network machine learning model is developed to control a bimorph adaptive mirror to achieve and preserve aberration-free coherent X-ray wavefronts at synchrotron radiation and free electron laser beamlines. The controller is trained on a mirror actuator response directly measured at a beamline with a real-time single-shot wavefront sensor, which uses a coded mask and wavelet-transform analysis. The system has been successfully tested on a bimorph deformable mirror at the 28-ID IDEA beamline of the Advanced Photon Source at Argonne National Laboratory. It achieved a response time of a few seconds and maintained desired wavefront shapes (e.g., a spherical wavefront) with sub-wavelength accuracy at 20 keV of X-ray energy. This result is significantly better than what can be obtained using a linear model of the mirror's response. The developed system has not been tailored to a specific mirror and can be applied, in principle, to different kinds of bending mechanisms and actuators.

9.
Opt Express ; 31(24): 39514-39527, 2023 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-38041271

RESUMEN

We describe the application of an AI-driven system to autonomously align complex x-ray-focusing mirror systems, including mirrors systems with variable focus spot sizes. The system has been developed and studied on a digital twin of nanofocusing X-ray beamlines, built using advanced optical simulation tools calibrated with wavefront sensing data collected at the beamline.We experimentally demonstrated that the system is reliably capable of positioning a focused beam on the sample, both by simulating the variation of a beamline with random perturbations due to typical changes in the light source and optical elements over time, and by conducting similar tests on an actual focusing mirror system.

10.
J Synchrotron Radiat ; 29(Pt 1): 159-166, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34985433

RESUMEN

Rigorous dynamical theory calculations show that four-beam diffraction (4BD) can be activated only by a unique photon energy and a unique incidence direction. Thus, 4BD may be used to precisely calibrate X-ray photon energies and beam positions. Based on the principles that the forbidden-reflection 4BD pattern, which is typically an X-shaped cross, can be generated by instant imaging using the divergent beam from a point source without rocking the crystal, a detailed real-time high-resolution beam (and source) position monitoring scheme is illustrated for monitoring two-dimensional beam positions and directions of modern synchrotron light sources, X-ray free-electron lasers and nano-focused X-ray sources.

11.
Arch Microbiol ; 204(6): 299, 2022 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-35513559

RESUMEN

Microbiologically influenced corrosion (MIC) is becoming a knotty problem for transmission pipelines. Developing MIC mitigation strategies for pipelines is increasingly urgent. In this study, MIC resistance against Pseudomonas aeruginosa of the X65 pipeline steels with (X65Cu) and without (X65) Cu addition was comparatively studied by electrochemical measurements and surface observation. Experimental results demonstrated that the corrosion rate of X65Cu steel was lower than that of X65 steel no matter in sterile or bacteria-containing media. Cu addition is helpful to the formation of the rust layer in the sterile medium. Surface observation showed that X65Cu steel exhibited a better MIC resistance against P. aeruginosa than that of X65 steel. Cu ions released from the X65Cu steel could effectively kill the P. aeruginosa attached on the steel surface, thus evidently decreased the pit depth and diameter.


Asunto(s)
Pseudomonas aeruginosa , Acero , Biopelículas , Corrosión , Acero/farmacología
12.
J Synchrotron Radiat ; 28(Pt 1): 125-130, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33399561

RESUMEN

Side-bounce beamlines with fixed-exit angles have been intended to operate with only one selected energy. However, a tunable monochromator in a new geometry is presented here that will make side-bounce beamlines energy tunable. It requires the addition of two more rotations. Analytic solutions for the values of these two rotation angles are provided. The validity of the new concept was checked by ray tracing and two-dimensional searches in the additional angles. Operational details on the new scheme, including the exit offset and steering of the beams, were determined. In addition to tunability, the new monochromator will reduce the loss from the polarization factor at low energies.

13.
J Synchrotron Radiat ; 27(Pt 5): 1108-1120, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32876585

RESUMEN

The OASYS suite and its powerful integration features are used to implement a ray-tracing algorithm to accurately calculate the thermal load in any component of an undulator-based synchrotron beamline. This is achieved by sampling and converting the SRW source of a given energy into a Shadow source and using the latter code to ray trace the full beamline. The accuracy of the algorithm is proved by reconstructing the full undulator radiation distribution through an aperture and comparing the result with direct calculaton of the total power using SRW. The algorithm is particularly suited to analyze cases with complex beamline layouts and optical elements, such as crystals, multilayers, and compound refractive lenses. Examples of its use to calculate the power load on elements of two of the feature beamlines at the Advanced Photon Source Upgrade Project and a comparison of the results with analytical calculations are presented.

14.
J Synchrotron Radiat ; 27(Pt 2): 254-261, 2020 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32153264

RESUMEN

Wavefront sensing at X-ray free-electron lasers is important for quantitatively understanding the fundamental properties of the laser, for aligning X-ray instruments and for conducting scientific experimental analysis. A fractional Talbot wavefront sensor has been developed. This wavefront sensor enables measurements over a wide range of energies, as is common on X-ray instruments, with simplified mechanical requirements and is compatible with the high average power pulses expected in upcoming X-ray free-electron laser upgrades. Single-shot measurements were performed at 500 eV, 1000 eV and 1500 eV at the Linac Coherent Light Source. These measurements were applied to study both mirror alignment and the effects of undulator tapering schemes on source properties. The beamline focal plane position was tracked to an uncertainty of 0.12 mm, and the source location for various undulator tapering schemes to an uncertainty of 1 m, demonstrating excellent sensitivity. These findings pave the way to use the fractional Talbot wavefront sensor as a routine, robust and sensitive tool at X-ray free-electron lasers as well as other high-brightness X-ray sources.

15.
Opt Express ; 28(22): 33053-33067, 2020 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-33114975

RESUMEN

We introduce a new X-ray speckle-vector tracking method for phase imaging, which is based on the wavelet transform. Theoretical and experimental results show that this method, which is called wavelet-transform-based speckle-vector tracking (WSVT), has stronger noise robustness and higher efficiency compared with the cross-correlation-based method. In addition, the WSVT method has the controllable noise reduction and can be applied with fewer scan steps. These unique features make the WSVT method suitable for measurements of large image sizes and phase shifts, possibly under low-flux conditions, and has the potential to broaden the applications of speckle tracking to new areas requiring faster phase imaging and real-time wavefront sensing, diagnostics, and characterization.

16.
Opt Express ; 28(13): 19242-19254, 2020 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-32672205

RESUMEN

This article describes the development and testing of a novel, water-cooled, active optic mirror system (called "REAL: Resistive Element Adjustable Length") that combines cooling with applied auxiliary heating, tailored to the spatial distribution of the thermal load generated by the incident beam. This technique is theoretically capable of sub-nanometer surface figure error control even at high power density. Tests conducted in an optical metrology laboratory and at synchrotron X-ray beamlines showed the ability to maintain the mirror profile to the level needed for the next generation storage rings and FEL mirrors.

17.
J Synchrotron Radiat ; 26(Pt 6): 1863-1871, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31721728

RESUMEN

The recently developed vertical phase-space beam position and size monitor (ps-BPM) system has proven to be able to measure the electron-source position, angle, size and divergence simultaneously in the vertical plane at a single location of a beamline. The optimization of the ps-BPM system is performed by ray-tracing simulation to maximize the instrument sensitivity and resolution. The contribution of each element is studied, including the monochromator, the K-edge filter, the detector and the source-to-detector distance. An optimized system is proposed for diffraction-limited storage rings, such as the Advanced Photon Source Upgrade project. The simulation results show that the ps-BPM system can precisely monitor the source position and angle at high speed. Precise measurements of the source size and divergence will require adequate resolution with relatively longer integration time.

18.
J Synchrotron Radiat ; 26(Pt 4): 1198-1207, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31274444

RESUMEN

The MOI (Mutual Optical Intensity) code for propagating partially coherent radiation through beamline optics is updated by including the in-plane wavevector in the wavefield calculation. The in-plane wavevector is a local function and accurately describes the average phase distribution in a partially coherent wavefield. The improved MOI code is demonstrated by beam propagation through free space and non-ideal mirrors. The improved MOI code can provide more accurate results with lower numbers of elements, and thus has a higher calculation efficiency. Knowledge of the in-plane wavevector also enables detailed studies of wavefield information under different coherence conditions. The improved MOI code is available at http://www.moixray.cn.

19.
J Synchrotron Radiat ; 26(Pt 4): 1213-1219, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31274446

RESUMEN

An electron beam position and angle monitoring system, ps-BPM, has been shown to be able to measure the electron source position and angle at a single location in a beamline at a synchrotron source. This system uses a monochromator to prepare a photon beam whose energy is at that of the K-edge of an absorber filter. The divergence of the beam from the source gives an energy range that will encompass the K-edge of the filter. A measurement of the centre of the monochromatic beam and the K-edge location through the absorber filter gives the position and angle of the electron source. Here, it is shown that this system is also capable of measuring the source size and divergence at the same time. This capability is validated by measurement as the beam size in the storage ring was changed and by ray-tracing simulations. The system operates by measuring the photon beam spatial distribution as well as a K-edge filtered beam distribution. These additional measurements result in the ability to also determine the electron source size and divergence.

20.
J Synchrotron Radiat ; 26(Pt 6): 1887-1901, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31721731

RESUMEN

Different approaches to simulate a modern X-ray beamline are considered. Several methodologies with increasing complexity are applied to discuss the relevant parameters that quantify the beamline performance. Parameters such as flux, dimensions and intensity distribution of the focused beam, and coherence properties are obtained from simple analytical calculations to sophisticated computer simulations using ray-tracing and wave optics techniques. A latest-generation X-ray nanofocusing beamline for coherent applications (ID16A at the ESRF) has been chosen to study in detail the issues related to highly demagnifying synchrotron sources and exploiting the beam coherence. The performance of the beamline is studied for two storage rings: the old ESRF-1 (emittance 4000 pm) and the new ESRF-EBS (emittance 150 pm). In addition to traditional results in terms of flux and beam sizes, an innovative study on the partial coherence properties based on the propagation of coherent modes is presented. The different algorithms and methodologies are implemented in the software suite OASYS. These are discussed with emphasis placed upon the their benefits and limitations of each.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA