Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Heart Fail Rev ; 28(4): 865-878, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36872393

RESUMEN

Risk stratification for sudden cardiac death in dilated cardiomyopathy is a field of constant debate, and the currently proposed criteria have been widely questioned due to their low positive and negative predictive value. In this study, we conducted a systematic review of the literature utilizing the PubMed and Cochrane library platforms, in order to gain insight about dilated cardiomyopathy and its arrhythmic risk stratification utilizing noninvasive risk markers derived mainly from 24 h electrocardiographic monitoring. The obtained articles were reviewed in order to register the various electrocardiographic noninvasive risk factors used, their prevalence, and their prognostic significance in dilated cardiomyopathy. Premature ventricular complexes, nonsustained ventricular tachycardia, late potentials on Signal averaged electrocardiography, T wave alternans, heart rate variability and deceleration capacity of the heart rate, all have both some positive and negative predictive value to identify patients in higher likelihood for ventricular arrhythmias and sudden cardiac death. Corrected QT, QT dispersion, and turbulence slope-turbulence onset of heart rate have yet to establish a predictive correlation in the literature. Although ambulatory electrocardiographic monitoring is frequently used in clinical practice in DCM patients, no single risk marker can be used for the selection of patients at high-risk for malignant ventricular arrhythmic events and sudden cardiac death who could benefit from the implantation of a defibrillator. More studies are needed in order to establish a risk score or a combination of risk factors with the purpose of selecting high-risk patients for ICD implantation in the context of primary prevention.


Asunto(s)
Cardiomiopatía Dilatada , Electrocardiografía Ambulatoria , Humanos , Electrocardiografía Ambulatoria/efectos adversos , Cardiomiopatía Dilatada/complicaciones , Electrocardiografía , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Arritmias Cardíacas/complicaciones , Factores de Riesgo , Pronóstico
2.
Int J Mol Sci ; 24(15)2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37569484

RESUMEN

Extensive research has been conducted to elucidate and substantiate the crucial role of the Renin-Angiotensin System (RAS) in the pathogenesis of hypertension, cardiovascular disorders, and renal diseases. Furthermore, the role of oxidative stress in maintaining vascular balance has been well established. It has been observed that many of the cellular effects induced by Angiotensin II (Ang II) are facilitated by reactive oxygen species (ROS) produced by nicotinamide adenine dinucleotide phosphate (NADPH) oxidase. In this paper, we present a comprehensive overview of the role of ROS in the physiology of human blood vessels, specifically focusing on its interaction with RAS. Moreover, we delve into the mechanisms by which clinical interventions targeting RAS influence redox signaling in the vascular wall.


Asunto(s)
Hipertensión , Sistema Renina-Angiotensina , Humanos , Especies Reactivas de Oxígeno/farmacología , Hipertensión/tratamiento farmacológico , Angiotensina II/metabolismo , Homeostasis , NADPH Oxidasas/metabolismo
3.
BMC Med ; 20(1): 193, 2022 05 31.
Artículo en Inglés | MEDLINE | ID: mdl-35637488

RESUMEN

BACKGROUND: There is no consensus on the most efficient catheter ablation (CA) strategy for patients with atrial fibrillation (AF). The objective of this study was to compare the efficacy and safety of different CA strategies for AF ablation through network meta-analysis (NMA). METHODS: A systematic search of PubMed, Web of Science, and CENTRAL was performed up to October 5th, 2020. Randomized controlled trials (RCT) comparing different CA approaches were included. Efficacy was defined as arrhythmia recurrence after CA and safety as any reported complication related to the procedure during a minimum follow-up time of 6 months. RESULTS: In total, 67 RCTs (n = 9871) comparing 19 different CA strategies were included. The risk of recurrence was significantly decreased compared to pulmonary vein isolation (PVI) alone for PVI with renal denervation (RR: 0.60, CI: 0.38-0.94), PVI with ganglia-plexi ablation (RR: 0.62, CI: 0.41-0.94), PVI with additional ablation lines (RR: 0.8, CI: 0.68-0.95) and PVI in combination with bi-atrial modification (RR: 0.32, CI: 0.11-0.88). Strategies including PVI appeared superior to non-PVI strategies such as electrogram-based approaches. No significant differences in safety were observed. CONCLUSIONS: This NMA showed that PVI in combination with additional CA strategies, such as autonomic modulation and additional lines, seem to increase the efficacy of PVI alone. These strategies can be considered in treating patients with AF, since, additionally, no differences in safety were observed. This study provides decision-makers with comprehensive and comparative evidence about the efficacy and safety of different CA strategies. SYSTEMATIC REVIEW REGISTRATION: PROSPERO registry number: CRD42020169494 .


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Humanos , Metaanálisis en Red , Venas Pulmonares/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto , Sistema de Registros
4.
Ann Noninvasive Electrocardiol ; 27(5): e12946, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35795926

RESUMEN

BACKGROUND: Electrocardiographic non-invasive risk factors (NIRFs) have an important role in the arrhythmic risk stratification of post-myocardial infarction (post-MI) patients with preserved or mildly reduced left ventricular ejection fraction (LVEF). However, their specific relation to left ventricular systolic function remains unclear. We aimed to evaluate the association between NIRFs and LVEF in the patients included in the PRESERVE-EF trial. METHODS: We studied 575 post-MI ischemia-free patients with LVEF≥40% (mean age: 57.0 ± 10.4 years, 86.2% men). The following NIRFs were evaluated: premature ventricular complexes, non-sustained ventricular tachycardia (NSVT), late potentials (LPs), prolonged QTc, increased T-wave alternans, reduced heart rate variability, and abnormal deceleration capacity with abnormal turbulence. RESULTS: There was a statistically significant relationship between LPs (Chi-squared = 4.975; p < .05), nsVT (Chi-squared = 5.749, p < .05), PVCs (r= -.136; p < .01), and the LVEF. The multivariate linear regression analysis showed that LPs (p = .001) and NSVT (p < .001) were significant predictors of the LVEF. The results of the multivariate logistic regression analysis indicated that LPs (OR: 1.76; 95% CI: 1.02-3.05; p = .004) and NSVT (OR: 2.44; 95% CI: 1.18-5.04; p = .001) were independent predictors of the mildly reduced LVEF: 40%-49% versus the preserved LVEF: ≥50%. CONCLUSION: Late potentials and NSVT are independently related to reduced LVEF while they are independent predictors of mildly reduced LVEF versus the preserved LVEF. These findings may have important implications for the arrhythmic risk stratification of post-MI patients with mildly reduced or preserved LVEF.


Asunto(s)
Infarto del Miocardio , Disfunción Ventricular Izquierda , Complejos Prematuros Ventriculares , Anciano , Electrocardiografía , Femenino , Humanos , Lipopolisacáridos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Factores de Riesgo , Volumen Sistólico/fisiología , Función Ventricular Izquierda , Complejos Prematuros Ventriculares/complicaciones
5.
Ann Noninvasive Electrocardiol ; 27(2): e12908, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34873786

RESUMEN

BACKGROUND: In the PRESERVE-EF study, a two-step sudden cardiac death (SCD) risk stratification approach to detect post-myocardial infarction (MI) patients with left ventricle ejection fraction (LVEF) ≥40% at risk for major arrhythmic events (MAEs) was used. Seven noninvasive risk factors (NIRFs) were extracted from a 24-h ambulatory electrocardiography (AECG) and a 45-min resting recording. Patients with at least one NIRF present were referred for invasive programmed ventricular stimulation (PVS) and inducible patients received an Implantable Cardioverter - Defibrillator (ICD). METHODS: In the present study, we evaluated the performance of the NIRFs, as they were described in the PRESERVE-EF study protocol, in predicting a positive PVS. In the PRESERVE-EF study, 152 out of 575 patients underwent PVS and 41 of them were inducible. For the present analysis, data from these 152 patients were analyzed. RESULTS: Among the NIRFs examined, the presence of signal averaged ECG-late potentials (SAECG-LPs) ≥ 2/3 and non-sustained ventricular tachycardia (NSVT) ≥1 eposode/24 h cutoff points were important predictors of a positive PVS study, demonstrating in the logistic regression analysis odds ratios 2.285 (p = .027) and 2.867 (p = .006), respectively. A simple risk score based on the above cutoff points in combination with LVEF < 50% presented high sensitivity but low specificity for a positive PVS. CONCLUSION: Cutoff points of NSVT ≥ 1 episode/24 h and SAECG-LPs ≥ 2/3 in combination with a LVEF < 50% were important predictors of inducibility. However, the final decision for an ICD implantation should be based on a positive PVS, which is irreplaceable in risk stratification.


Asunto(s)
Infarto del Miocardio , Taquicardia Ventricular , Arritmias Cardíacas , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía/efectos adversos , Ventrículos Cardíacos , Humanos , Lipopolisacáridos , Infarto del Miocardio/complicaciones , Estudios Prospectivos , Factores de Riesgo , Volumen Sistólico/fisiología , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/diagnóstico
6.
J Cardiovasc Electrophysiol ; 32(2): 491-499, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33345428

RESUMEN

INTRODUCTION: Transvenous lead extraction (TLE) is critical in the long-term management of patients with cardiac implanted electronic devices (CIEDs). The aim of the study is to evaluate the outcomes of TLE and to investigate the impact of infection. METHODS AND RESULTS: Data of patients undergoing extraction of permanent pacemaker and defibrillator leads during October 2014-September 2019 were prospectively analyzed. Overall, 242 consecutive patients (aged 71.0 ± 14.0 years, 31.4% female), underwent an equal number of TLE operations for the removal of 516 leads. Infection was the commonest indication (n = 201, 83.1%). Mean implant-to-extraction duration was 7.6 ± 5.4 years. Complete procedural success was recorded in 96.1%, and clinical procedural success was achieved in 97.1% of attempted lead extractions. Major complications occurred in two (0.8%) and minor complications in seven (2.9%) patients. Leads were removed exclusively by using locking stylets in 65.7% of the cases. In the subgroup of noninfective patients, advanced extraction tools were more frequently required compared to patients with CIED infections, to extract leads (success only with locking stylet: 55.8% vs. 67.8%, p = .032). In addition, patients without infection demonstrated lower complete procedural success rates (90.7% vs. 97.2%, p = .004), higher major complication rates (2.4% vs. 0.5%, p = .31) and longer procedural times (136 ± 13 vs. 111 ± 15 min, p = .001). CONCLUSIONS: Our data demonstrate high procedural efficacy and safety and indicate that in patients with noninfective indications, the procedure is more demanding, thus supporting the hypothesis that leads infection dissolves and/or prohibits the formation of fibrotic adherences.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/efectos adversos , Femenino , Humanos , Masculino , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
7.
Ann Noninvasive Electrocardiol ; 26(5): e12850, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33955102

RESUMEN

Syncope represents a relatively uncommon symptom of supraventricular tachycardia (SVT). It is likely that an impaired autonomic vasomotor response to the hemodynamic stress of tachycardia is the determinant of hemodynamic changes leading to cerebral hypoperfusion and syncope. In this regard, tilt-table test may detect abnormalities in the autonomic nervous function and predict the occurrence of syncope during SVT. Electrophysiology studies may reproduce the SVT, distinguish it from other life-threatening ventricular tachyarrhythmias, and exclude other causes of syncope. Not infrequently mixed syncope mechanisms are revealed during the above diagnostic workup raising doubts about the operating mechanism in the clinical setting. In such cases of uncertainty, an implantable loop recorder, providing long-term cardiac monitoring, may play a pivotal role in the establishment of the diagnosis, confirming the association of an arrhythmic event with the symptom. Herein, we present four such cases with recurrent unexplained syncope finally attributed to paroxysmal SVT guiding them to a potentially radical treatment through radiofrequency catheter ablation.


Asunto(s)
Taquicardia Supraventricular , Taquicardia Ventricular , Electrocardiografía , Humanos , Síncope/diagnóstico , Síncope/etiología , Taquicardia Supraventricular/complicaciones , Taquicardia Supraventricular/diagnóstico , Pruebas de Mesa Inclinada
8.
Eur Heart J ; 40(35): 2940-2949, 2019 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-31049557

RESUMEN

AIMS: Sudden cardiac death (SCD) annual incidence is 0.6-1% in post-myocardial infarction (MI) patients with left ventricular ejection fraction (LVEF)≥40%. No recommendations for implantable cardioverter-defibrillator (ICD) use exist in this population. METHODS AND RESULTS: We introduced a combined non-invasive/invasive risk stratification approach in post-MI ischaemia-free patients, with LVEF ≥ 40%, in a multicentre, prospective, observational cohort study. Patients with at least one positive electrocardiographic non-invasive risk factor (NIRF): premature ventricular complexes, non-sustained ventricular tachycardia, late potentials, prolonged QTc, increased T-wave alternans, reduced heart rate variability, abnormal deceleration capacity with abnormal turbulence, were referred for programmed ventricular stimulation (PVS), with ICDs offered to those inducible. The primary endpoint was the occurrence of a major arrhythmic event (MAE), namely sustained ventricular tachycardia/fibrillation, appropriate ICD activation or SCD. We screened and included 575 consecutive patients (mean age 57 years, LVEF 50.8%). Of them, 204 (35.5%) had at least one positive NIRF. Forty-one of 152 patients undergoing PVS (27-7.1% of total sample) were inducible. Thirty-seven (90.2%) of them received an ICD. Mean follow-up was 32 months and no SCDs were observed, while 9 ICDs (1.57% of total screened population) were appropriately activated. None patient without NIRFs or with NIRFs but negative PVS met the primary endpoint. The algorithm yielded the following: sensitivity 100%, specificity 93.8%, positive predictive value 22%, and negative predictive value 100%. CONCLUSION: The two-step approach of the PRESERVE EF study detects a subpopulation of post-MI patients with preserved LVEF at risk for MAEs that can be effectively addressed with an ICD. CLINICALTRIALS.GOV IDENTIFIER: NCT02124018.


Asunto(s)
Arritmias Cardíacas/etiología , Infarto del Miocardio/complicaciones , Volumen Sistólico/fisiología , Adulto , Anciano , Arritmias Cardíacas/fisiopatología , Estimulación Cardíaca Artificial , Estudios de Cohortes , Puente de Arteria Coronaria , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio , Infarto del Miocardio/fisiopatología , Estudios Prospectivos , Medición de Riesgo , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Fibrilación Ventricular/etiología , Fibrilación Ventricular/fisiopatología
9.
J Cardiovasc Electrophysiol ; 30(3): 299-307, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30516299

RESUMEN

INTRODUCTION: Cardiac perforation of the right ventricle associated with pacemaker or implantable cardioverter defibrillator (ICD) leads' implantation is uncommon, albeit potentially life-threatening, complication. The aim of this study is to further identify the optimal therapeutic strategy, especially when lead dislocation has occurred outside the pericardial sac. METHODS AND RESULTS: The study population included 10 consecutive patients (six female, mean age: 66.5 years old) diagnosed with early ventricular lead perforation following a pacemaker or ICD implantation, with significant protrusion inside the pericardial sac (n = 2) or migration of the lead at the pleural space ( n = 3), the diaphragm ( n = 1), or the abdominal cavity ( n = 4), during the period 2013-2017. All patients were symptomatic; however, individuals presenting with hemodynamic instability were excluded. The outcome of the percutaneous therapeutic approach was retrospectively assessed. All patients underwent a successful removal of the perforating lead percutaneously at the electrophysiology lab, by direct traction, and repositioning in another location of the right ventricle. The operation was performed by a multidisciplinary team, under continuous hemodynamic and transesophageal echocardiographic monitoring and cardiac surgical backup. The periprocedural period was uneventful. Subjects were followed up for at least 1 year. Interestingly, all patients developed a type of postcardiac injury syndrome, successfully treated with a 3-month regimen of ibuprofen and colchicine. CONCLUSION: Percutaneous traction and repositioning of the perforating ventricular lead are effective, safe, and less invasive compared with the thoracotomy method in hemodynamically stable patients when dislocation has occurred outside the pericardial sac provided that there is no visceral organs injury.


Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos , Migración de Cuerpo Extraño/cirugía , Lesiones Cardíacas/cirugía , Ventrículos Cardíacos/cirugía , Marcapaso Artificial , Implantación de Prótesis/instrumentación , Anciano , Anciano de 80 o más Años , Remoción de Dispositivos/efectos adversos , Femenino , Migración de Cuerpo Extraño/diagnóstico por imagen , Migración de Cuerpo Extraño/etiología , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/lesiones , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Implantación de Prótesis/efectos adversos , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
10.
J Electrocardiol ; 51(4): 588-591, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29996995

RESUMEN

BACKGROUND: We extracted T Wave Alternans (TWA) from a 30 minute Short Resting Holter ECG (SRH ECG) in the supine position, as a Total Mortality (TM) predictor in Heart Failure (HF). METHODS: Signals from 146 HF patients (LVEF = 33 ±â€¯10%), were analyzed with Modified Moving Average method. After 42.1 months, 26 patients died. RESULTS: (Deceased vs Living group): TWA:31 ±â€¯18 µV vs 25 ±â€¯13 µV(p = 0.05), LVEF:32 ±â€¯10% vs 34 ±â€¯9% (p = 0.5), Heart Rate:73 ±â€¯11 bpm vs 69 ±â€¯12 bpm (p = 0.2), SDNN/HRV:45 ±â€¯42 ms vs 41 ±â€¯29 ms (p = 0.4), QRS:123 ±â€¯26 ms vs 119 ±â€¯29 ms (p = 0.5).Cox regression model adjusted for TWA, LVEF and QRS, revealed that the TWA was an independent TM predictor (H.R.: 1.022, 95% C.I.: 0.999-1.046, p = 0.05).The TWA ≥ 42 µV demonstrated HR: 2.521, (95% C.I.: 0.982-6.472, p = 0.05). CONCLUSIONS: In severely affected HF patients, TWA from a SRH ECG may be present even during slow resting heart rates and proved to be an important and independent TM predictor. The SRH ECG recording is an efficient and fast method for mortality risk evaluation in HF patients.


Asunto(s)
Electrocardiografía Ambulatoria , Insuficiencia Cardíaca/mortalidad , Anciano , Electrocardiografía Ambulatoria/métodos , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Pronóstico , Modelos de Riesgos Proporcionales , Descanso , Medición de Riesgo/métodos
13.
Artículo en Inglés | MEDLINE | ID: mdl-28252256

RESUMEN

BACKGROUND: Primary prevention of sudden cardiac death by means of implantable cardioverter-defibrillators constitutes the holy grail of arrhythmology. However, current risk stratification algorithms lead to suboptimal outcomes, by both allocating ICDs to patients not deriving any meaningful survival benefit and withholding them from those erroneously considered as low-risk for arrhythmic mortality. METHODS: In the present review article we will attempt to present shortcomings of contemporary guidelines regarding sudden death prevention in ischemic and dilated cardiomyopathy patients and present available data suggesting encouraging results following implementation of multifactorial approaches, by using multiple modalities, both noninvasive and invasive. Invasive electrophysiological testing, namely programmed ventricular stimulation, will be discussed in greater length to highlight both its potential usefulness and currently ongoing multicenter studies aiming to provide evidence necessary to make the next step in sudden death risk stratification. RESULTS: Promising findings have been reported by multiple study groups regarding novel strategies for both negative selection of low and positive selection of relatively preserved ejection fraction patients as candidates for ICD implantation. CONCLUSIONS: The era of ejection fraction as the sole risk stratifier for arrhythmic risk in heart failure appears to be drawing to an end, especially if current underway large studies validate previous findings.


Asunto(s)
Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/fisiopatología , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía/métodos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Humanos , Medición de Riesgo , Factores de Riesgo
14.
Europace ; 18(4): 473-8, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26516219

RESUMEN

A significant increase in the implantation of cardiac implantable electronic devices (CIEDs) is evident over the past years, while there is evidence for a disproportionate increase in CIED-related infections. The cumulative probability of device infection seems to be higher in implantable cardioverter defibrillator and in cardiac resynchronization therapy patients compared with permanent pacemaker patients. Given that more than a half of CIED infections are possibly related to the operative procedure, there is a need for effective periprocedural infection control. However, many of the current recommendations are empirical and not evidence-based, while questions, unresolved issues, and conflicting evidence arise. The perioperative systemic use of antibiotics confers significant benefit in prevention of CIED infections. However, there are no conclusive data regarding the specific value of each agent in different clinical settings, the value of post-operative antibiotic treatment as well as the optimal duration of therapy. The merit of local pocket irrigation with antibiotic and/or antiseptic agents remains unproved. Of note, recent evidence indicates that the application of antibacterial envelopes into the device pocket markedly decreases the infection risk. In addition, limited reports on strict integrated infection control protocols show a dramatic reduction in infection rates in this setting and therefore deserve further attention. Finally, the relative impact of particular factors on the infection risk, including the type of the CIED, patients' individual characteristics and comorbidities, should be further examined since it may facilitate the development of tailored prophylactic interventions for each patient.


Asunto(s)
Antibacterianos/administración & dosificación , Profilaxis Antibiótica , Desfibriladores Implantables/efectos adversos , Control de Infecciones/métodos , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/prevención & control , Esquema de Medicación , Humanos , Diseño de Prótesis , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Irrigación Terapéutica , Factores de Tiempo , Resultado del Tratamiento
17.
Pacing Clin Electrophysiol ; 39(4): 378-81, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26769172

RESUMEN

BACKGROUND: In the presence of tricuspid valve intervention, right ventricular lead implantation is associated with the potential risk of tricuspid valve malfunction leading to a tricuspid regurgitation. Few cases have been reported with successful left ventricular pacing via the coronary sinus (CS) after tricuspid valve replacement or repair. In this retrospective study, we present the long-term clinical outcomes of 17 patients who underwent CS lead implantation and left ventricular pacing. METHODS: Seventeen consecutive patients referred to our institution with an indication of postprocedural pacemaker (PM) implantation after tricuspid valve intervention were retrospectively included in the study. The indication for device implantation in all patients was atrial fibrillation with a symptomatic pause ≥ 3.0 seconds. Thus, all devices implanted were ventricular rate responsive (VVIR). RESULTS: All device implantations were successful and uncomplicated. Mean operation time was 60 ± 8 minutes. Mean fluoroscopy time was 8.3 ± 2.1 minutes. Mean R-wave sensing was 7.5 ± 2.0 mV with a mean slew rate of 2.2 V/s. A mean pacing threshold of 1.9 ± 0.3 V/0.4 ms was accepted as patients were not PM-dependent. The pacing impedance was 743.5 ± 109.71 Ohm. At 2-year follow-up, pacing sensing, threshold, and impedance values were unchanged and no lead dislodgement has been noted. CONCLUSIONS: In patients with tricuspid valve intervention, left ventricular pacing might be the treatment of choice for permanent ventricular pacing, with all the advantages of the endovenous route as a minimally invasive approach.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Seno Coronario/cirugía , Electrodos Implantados , Ventrículos Cardíacos/cirugía , Implantación de Prótesis/métodos , Válvula Tricúspide/cirugía , Estudios de Factibilidad , Humanos , Resultado del Tratamiento
18.
Pacing Clin Electrophysiol ; 39(7): 690-5, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27073123

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is often associated with conduction disturbances, followed by permanent pacemaker (PPM) implantation. Because of the potential reversibility of these conduction disorders, controversy exists regarding the right timing of PPM implantation. TAVI is routinely performed under dual-antiplatelet and antithrombotic therapy, which poses an additional hemorrhagic risk on a same-day procedure. The aim of the present study was to evaluate the safety and effectiveness of same-day PPM implantation in patients undergoing TAVI. METHODS: Consecutive patients undergoing TAVI with Medtronic Corevalve bioprosthesis (Medtronic Inc., Minneapolis, MN, USA) in a tertiary center were divided into two study groups. Group A included patients undergoing PPM implantation the same day with TAVI, and Group B patients were implanted with a PPM later after TAVI and before hospital discharge. The two study groups were compared for all complications associated with PPM implantation. RESULTS: In total, 168 patients were included in the study. PPM was implanted in 65 patients (38.7%). In 23 patients, a PPM was implanted the same day with TAVI (Group A) and in 42 patients PPM implantation was postponed at least 1 day (Group B). Cephalic vein was the access used for the leads in the majority of cases. There was only one case of pneumothorax in Group B. There were no differences in the incidence of pocket hematomas between the study groups. CONCLUSIONS: Same-day PPM implantation after TAVI is safe and feasible. Strategies reducing pocket hematomas are essential in such patients of high hemorrhagic risk.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/terapia , Marcapaso Artificial/estadística & datos numéricos , Prótesis e Implantes/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Anciano , Estenosis de la Válvula Aórtica/epidemiología , Terapia Combinada/métodos , Femenino , Grecia/epidemiología , Humanos , Masculino , Prevalencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
19.
J Innov Card Rhythm Manag ; 15(6): 5908-5910, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38948666

RESUMEN

Cardiac implantable electronic devices (CIEDs) are essential tools in cardiology for tackling rhythm disturbances and have come a long way over the last decades. Technology is shifting toward leadless devices that spare the complications and limitations of traditional intravascular CIEDs. Herein, we report the simultaneous implantation of a leadless pacemaker (LP) and a subcutaneous implantable cardioverter-defibrillator (S-ICD) in two patients with hypertrophic cardiomyopathy, as well as their 2-year follow-up results, while explaining the preventive measures taken to steer around unwanted device interaction. Implantation of an S-ICD with an LP is reserved for unique cases but is a feasible approach when there is a contraindication for intravascular CIED implantation. Furthermore, this technique may be used in younger patients with cardiomyopathies in whom multiple generator replacements are expected, along with their known adverse effects.

20.
Life (Basel) ; 14(7)2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-39063625

RESUMEN

PURPOSE: Syncope remains a common medical problem. Recently, the role of dedicated syncope units and implantable loop recorders has emerged in the investigation of unexplained syncope. This study aims to investigate the possibilities for a more rational and targeted use of various diagnostic tools. METHODS: In this retrospective single-center study, 196 patients with unexplained syncope were included between March 2019 and February 2023. Various diagnostic tools were utilized during the investigation, according to clinical judgement. Patients were retrospectively allocated into Group A (including those who, among other tests, underwent loop recorder insertion) and Group B (including patients investigated without loop recorder implantation). Data were compared with Group C, including patients assessed prior to syncope unit establishment. RESULTS: There was no difference between Group A (n = 133) and Group B (n = 63) in the diagnostic yield (74% vs. 76%, p = 0.22). There were significant differences between Groups A and B regarding age (67.3 ± 16.9 years vs. 48.3 ± 19.1 years, p < 0.001) and cause of syncope (cardiogenic in 69% of Group A, reflex syncope in 77% of Group B, p < 0.001). Electrocardiography-based diagnosis occurred in 55% and 19% of Groups A and B, respectively (p < 0.001). The time to diagnosis was 4.2 ± 2.7 months in Group A and 7.5 ± 5.6 months in Group B (p < 0.001). In Group C, the diagnostic yield was 57.9% and the electrocardiography-based diagnostic yield was 18.3%. CONCLUSIONS: A selective use of loop recorders according to clinical and electrocardiographic characteristics increases the effectiveness of the structured syncope unit approach and further preserves financial resources.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA