Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Electrophoresis ; 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38984929

RESUMEN

Glucagon plays a crucial role in regulating glucose homeostasis; unfortunately, the mechanisms controlling its release are still unclear. Capillary electrophoresis (CE)- and fluorescence anisotropy (FA)-immunoassays (IA) have been used for online measurements of hormone secretion on microfluidic platforms, although their use in glucagon assays is less common. We set out to compare a glucagon-competitive IA using these two techniques. Theoretical calibration curves were generated for both CE- and FA-IA and results indicated that CE-IA provided higher sensitivity than FA-IA. These results were confirmed in an experiment where both assays showed limits of detection (LOD) of 30 nM, but the CE-IA had ∼300-fold larger sensitivity from 0 to 200 nM glucagon. However, in online experiments where reagents were mixed within the device, the sensitivity of the CE-IA was reduced ∼3-fold resulting in a higher LOD of 70 nM, whereas the FA-IA remained essentially unchanged. This lowered sensitivity in the online CE-IA was likely due to poor sampling by electroosmotic flow from the high salt solution necessary in online experiments, whereas pressure-based sampling used in FA-IA was not affected. We conclude that FA-IA, despite lowered sensitivity, is more suitable for online mixing scenarios due to the ability to use pressure-driven flow and other practical advantages such as the use of larger channels.

2.
Artículo en Inglés | MEDLINE | ID: mdl-37976942

RESUMEN

D-amino acids (D-AAs) are important signaling molecules due to their ability to bind ionotropic N-methyl-D-aspartate receptors. D-serine (D-Ser), D-alanine (D-Ala), and D-aspartate (D-Asp) have been found individually in the endocrine portion of the pancreas, the islets of Langerhans, and/or their secretions. However, there has been no report of a comprehensive assessment of D-AAs in islet secretions. To evaluate the release of these compounds, the effectiveness of both 1-(9-fluorenyl)-ethyl chloroformate (FLEC reagent) and 1-fluoro-2,4-dinitrophenyl-5-L-alanine amide (Marfey's reagent, MR) in separation of D/L-AA enantiomeric pairs in islet-specific buffers were evaluated. MR-derivatized D/L AAs showed greater than baseline resolution (Rs ≥ 1.5) of 13 enantiomeric pairs when using a non-linear gradient and an acidic mobile phase system, while FLEC-derivatized AAs exhibited limited resolution on both biphenyl and C18 columns. The optimized MR method yielded highly reproducible separations with retention times less than 1% RSD. Excellent linearity between the analyte concentrations and response (R2 > 0.98) were obtained, with less than 15% RSD for all analyte responses. Most analytes had an LOD at or below 100 nM, except for L-Ala (200 nM). The optimized MR method was used to quantify D-AAs in secretions of 150 murine islets after incubation in 3- and 20-mM glucose. In response to both solutions, D-Ser and D-glutamine were tentatively identified via comparison of retention time and quantifier-to-qualifer ion ratios with standards, and from spiking experiments. Both were secreted in low quantities which did not differ significantly in either low (D-Ser: 44 ± 2 fmol islet-1h-1; D-Gln: 300 ± 100 fmol islet-1h-1) or high (D-Ser: 23 ± 1 fmol islet-1h-1; D-Gln: 120 ± 50 fmol islet-1h-1) glucose across 3 biological replicates. The method developed is robust and can be applied to further examine the release of D-AAs and their potential roles in islet physiology.


Asunto(s)
Aminoácidos , Islotes Pancreáticos , Animales , Ratones , Aminoácidos/análisis , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Alanina/química , Glucosa , Estereoisomerismo , Cromatografía Líquida de Alta Presión/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA