Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 19(11): 1781-1789, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-27707782

RESUMEN

AIMS: Identifying patients who benefit from restored sinus rhythm (SR) would optimize the selection of candidates for ablation of long-standing persistent atrial fibrillation (LSPAF). This prospective study sought to identify the hitherto unknown factors associated with global functional improvement after successful radiofrequency catheter ablation of LSPAF. METHODS AND RESULTS: In 171 LSPAF patients (84% of the total consecutive 203 patients) who were examined in SR 12 months after ablation, the individual per cent change from baseline value in maximum oxygen consumption at exercise test (VO2 max), left ventricular ejection fraction (LVEF), N-terminal prohormone of brain natriuretic peptide (NT-proBNP), and five-dimensional descriptive system (EQ-5D) of quality-of-life questionnaire were classified in quartiles by 0 (worse) to 3 (best) grades. The individual grades were summed into a composite score (SCORE, 0 … 12) reflecting global functional improvement. Significant improvement in VO2 max (3.4 ± 4.7 mL/kg/min), LVEF (7.5 ± 9.1%), NT-proBNP (-861 ± 809 pg/mL), and EQ-5D (0.7 ± 0.12) was observed (all P < 0.0001). On multivariable analysis, younger age (P = 0.001), male gender (P = 0.02), timely post-ablation left atrial appendage (LAA) outflow (P = 0.005) with improvement in outflow velocity (P = 0.0002), and withdrawal of Class I/III antiarrhythmic drugs (P < 0.05) were positively and independently correlated with the SCORE. CONCLUSIONS: Younger male patients benefited most from catheter ablation of LSPAF. Delayed or non-improved LAA outflow and inability to discontinue Class I/III antiarrhythmic medication reduced the post-ablation functional improvement.


Asunto(s)
Fibrilación Atrial/cirugía , Función del Atrio Izquierdo , Ablación por Catéter , Tolerancia al Ejercicio , Función Ventricular Izquierda , Adulto , Factores de Edad , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Biomarcadores/sangre , Ablación por Catéter/efectos adversos , Distribución de Chi-Cuadrado , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Péptido Natriurético Encefálico/sangre , Consumo de Oxígeno , Fragmentos de Péptidos/sangre , Estudios Prospectivos , Calidad de Vida , Recuperación de la Función , Sistema de Registros , Factores de Riesgo , Factores Sexuales , Volumen Sistólico , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento
2.
Europace ; 16(1): 15-25, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23851514

RESUMEN

AIMS: Clinical benefit from ablation for long-standing persistent atrial fibrillation has remained unknown. We hypothesized that successful ablation of long-standing persistent atrial fibrillation would improve haemodynamics, functional status, and quality of life. METHODS AND RESULTS: A total of 160 patients (aged 59 ± 9 years, 23% females) undergoing ablation of long-standing (median of 28 months) persistent atrial were enrolled in this prospective study. Morphological and functional echocardiographic parameters, N-terminal prohormone of brain natriuretic peptide (NT-proBNP), maximum oxygen consumption during exercise test (VO2 max), and quality of life were assessed at baseline and 1 year after the ablation.  At the 1-year follow-up visit, 81% patients were examined in sinus rhythm (after repeat ablation in 38% patients). Left atrial appendage outflow velocity increased from 44 ± 20 to 58 ± 23 cm/s, left ventricular ejection fraction from 54 ± 9 to 59 ± 5%, and VO2 max from 20.4 ± 6.4 to 23.7 ± 8.1 mL/kg/min; NT-proBNP decreased from median 897 (interquartile range 603-1424) to 230 (interquartile range 120-420) pg/mL (all P < 0.0001). These beneficial effects of ablation were predominantly associated with the presence of sinus rhythm. Quality of life (range 0-100) increased significantly (EQ-5D index: from 68.8 ± 12.5 to 75.4 ± 14.4; EQ-VAS score: from 62.8 ± 13.2 to 70.6 ± 13.8; both P < 0.0001). CONCLUSION: Ablation of long-standing persistent atrial fibrillation was associated with significant recovery of haemodynamics and exercise capacity that projected onto the long-term improvement in quality of life.


Asunto(s)
Fibrilación Atrial/psicología , Fibrilación Atrial/cirugía , Ablación por Catéter/psicología , Depresión/psicología , Complicaciones Posoperatorias/psicología , Calidad de Vida/psicología , Recuperación de la Función , Actividades Cotidianas/psicología , Adulto , Anciano , Fibrilación Atrial/diagnóstico , Ablación por Catéter/efectos adversos , Enfermedad Crónica , Depresión/etiología , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Resultado del Tratamiento
3.
J Clin Med ; 13(17)2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39274510

RESUMEN

This review examines the relationship between the physiological demands of diving and premature ventricular complexes (PVCs) in divers. In the general population, some individuals have a greater tendency to experience PVCs, often without awareness or a clear understanding of the triggering factors. With the increasing availability and popularity of both scuba and apnoea diving, more people, including those with a predisposition to PVCs, are engaging in these activities. The underwater environment, with its unique stressors, may increase the risk of arrhythmogenic events, particularly PVCs. Here, we review the prevalence, pathophysiology, and aggravating factors of PVCs in divers, emphasising the need for a comprehensive cardiovascular assessment. Evidence suggests a higher prevalence of PVCs in divers compared with the general population, influenced by factors such as age, dive depth, gas bubbles, cold water immersion, pre-existing cardiovascular diseases, and lifestyle factors. The change in environment during diving could potentially trigger an increased frequency of PVCs, especially in individuals with a pre-existing tendency. We discuss diagnostic strategies, management approaches, and preventive measures for divers with PVCs, noting that although guidelines for athletes can be adapted, individual assessment is crucial. Significant knowledge gaps are identified, highlighting the need for future research to develop evidence-based guidelines and understand the long-term significance of PVCs in divers. This work aims to evaluate potential contributing factors to PVCs in divers and identify individuals who may be at higher risk of experiencing major adverse cardiovascular events (MACEs). This work aims to improve diver safety by promoting collaboration between cardiologists and diving medicine specialists and by identifying key areas for future investigation in this field. This work aims to improve the safety and well-being of divers by understanding the cardiovascular challenges they face, including pressure changes, cold water immersion, and hypoxia. We seek to elucidate the relationship between these challenges and the occurrence of PVCs. By synthesising current evidence, identifying knowledge gaps, and proposing preliminary recommendations, we aim to encourage collaboration between cardiologists and diving medicine specialists to optimise the screening, management, and risk stratification of PVCs in the diving population.

4.
Healthcare (Basel) ; 12(10)2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38786387

RESUMEN

INTRODUCTION: Education of patients prior to an invasive procedure is pivotal for good cooperation and knowledge retention. Virtual reality (VR) is a fast-developing technology that helps educate both medical professionals and patients. OBJECTIVE: To prove non-inferiority of VR education compared to conventional education in patients prior to the implantation of a permanent pacemaker (PPM). METHODS: 150 participants scheduled for an elective implantation of a PPM were enrolled in this prospective study and randomized into two groups: the VR group (n = 75) watched a 360° video about the procedure using the VR headset Oculus Meta Quest 2, while the conventional group (n = 75) was educated by a physician. Both groups filled out a questionnaire to assess the quality of education pre- and in-hospital, their knowledge of the procedure, and their subjective satisfaction. RESULTS: There was no significant difference in the quality of education. There was a non-significant trend towards higher educational scores in the VR group. The subgroup with worse scores was older than the groups with higher scores (82 vs. 76 years, p = 0.025). Anxiety was reduced in 92% of participants. CONCLUSION: VR proved to be non-inferior to conventional education. It helped to reduce anxiety and showed no adverse effects.

5.
Hellenic J Cardiol ; 73: 24-35, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37088344

RESUMEN

BACKGROUND: For the treatment of patients with electrical storm (ES), we established a two-step algorithm comprising standard anti-arrhythmic measures and early ultrasound-guided stellate ganglion blockade (SGB). In this single-center study, we evaluated the short-term efficacy of the algorithm and tested the hypothesis that early SGB might prevent the need for intubations. METHODS: Overall, we analyzed data for 70 ES events in 59 patients requiring SGB (mean age 67.7 ± 12.4 years, 80% males, left ventricular ejection fraction 30.0% ± 9.1%), all with implantable cardioverter-defibrillators (ICDs). RESULTS: The mean time from ES onset to SGB was 13.2 ± 12.3 hours. Percentage and mean absolute reduction in shocks at 48 hours after SGB reached 86.8% (-6.3 shocks), and anti-tachycardiac pacing (ATP) declined by 65.9% (-51.1 ATPs; all P < 0.001). Patients with the highest sustained ventricular arrhythmia (VA) burden (shocks ≥10/48 h; ATPs 10-99/48 h and ≥100/48 h) experienced the highest percentage decrease in ICD therapy (shocks -99.1%; ATPs -92.1% and -100.0%, respectively). For clinical response by defined criteria and two outcome periods (1/no sustained VA ≤48 hours post SGB, and 2/no ICD shock or <3 ATPs/day from day 3 to discharge/catheter ablation/day 8), 75.7% and 76.1% experienced complete response, respectively. Catecholamine support, no/low-dose ß-blocker therapy, polymorphic/mixed-type VA, and baseline sinus rhythm versus atrial fibrillation were more frequent in patients with early arrhythmia recurrence. Temporary Horner's syndrome occurred in 67.1%, and no other adverse events were recorded. Intubation and general anesthesia during and after SGB were not needed. CONCLUSION: The presented two-step algorithm for treating ES proved efficacious and safe. The results support implementation of early SGB in routine ES management.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Taquicardia Ventricular , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Taquicardia Ventricular/etiología , Volumen Sistólico , Función Ventricular Izquierda , Fibrilación Atrial/etiología , Desfibriladores Implantables/efectos adversos , Intubación Intratraqueal/efectos adversos , Resultado del Tratamiento
6.
J Cardiovasc Dev Dis ; 10(4)2023 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-37103062

RESUMEN

Sudden cardiac death (SCD) is a leading cause of death among athletes, and those with a positive family history (FH) of SCD and/or cardiovascular disease (CVD) may be at increased risk. The primary objective of this study was to assess the prevalence and predictors of positive FH of SCD and CVD in athletes using four widely used preparticipation screening (PPS) systems. The secondary objective was to compare the functionality of the screening systems. In a cohort of 13,876 athletes, 1.28% had a positive FH in at least one PPS system. Multivariate logistic regression analysis identified the maximum heart rate as significantly associated with positive FH (OR = 1.042, 95% CI = 1.027-1.056, p < 0.001). The highest prevalence of positive FH was found using the PPE-4 system (1.20%), followed by FIFA, AHA, and IOC systems (1.11%, 0.89%, and 0.71%, respectively). In conclusion, the prevalence of positive FH for SCD and CVD in Czech athletes was found to be 1.28%. Furthermore, positive FH was associated with a higher maximum heart rate at the peak of the exercise test. The findings of this study revealed significant differences in detection rates between PPS protocols, so further research is needed to determine the optimal method of FH collection.

7.
Int J Cardiol ; 372: 71-75, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36473604

RESUMEN

BACKGROUND: Anderson-Fabry disease (AFD) is an X-linked inherited lysosomal disease caused by a defect in the gene encoding lysosomal enzyme α-galactosidase A (GLA). Atrio-ventricular (AV) nodal conduction defects and sinus node dysfunction are common complications of the disease. It is not fully elucidated how frequently AFD is responsible for acquired AV block or sinus node dysfunction and if some AFD patients could manifest primarily with spontaneous bradycardia in general population. The purpose of study was to evaluate the prevalence of AFD in male patients with implanted permanent pacemaker (PM). METHODS: The prospective multicentric screening in consecutive male patients between 35 and 65 years with implanted PM for acquired third- or second- degree type 2 AV block or symptomatic second- degree type 1 AV block or sinus node dysfunction was performed. RESULTS: A total of 484 patients (mean age 54 ± 12 years at time of PM implantation) were enrolled to the screening in 12 local sites in Czech Republic. Out of all patients, negative result was found in 481 (99%) subjects. In 3 cases, a GLA variant was found, classified as benign: p.Asp313Tyr, p.D313Y). Pathogenic GLA variants (classical or non-classical form) or variants of unclear significance were not detected. CONCLUSION: The prevalence of pathogenic variants causing AFD in a general population sample with implanted permanent PM for AV conduction defects or sinus node dysfunction seems to be low. Our findings do not advocate a routine screening for AFD in all adult males with clinically significant bradycardia.


Asunto(s)
Bloqueo Atrioventricular , Enfermedad de Fabry , Marcapaso Artificial , Adulto , Humanos , Masculino , Persona de Mediana Edad , Anciano , Bradicardia/complicaciones , Bradicardia/terapia , Enfermedad de Fabry/diagnóstico , Enfermedad de Fabry/epidemiología , Enfermedad de Fabry/genética , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/terapia , Síndrome del Seno Enfermo/diagnóstico , Síndrome del Seno Enfermo/epidemiología , Síndrome del Seno Enfermo/terapia , Estudios Prospectivos , Marcapaso Artificial/efectos adversos
8.
J Cardiovasc Dev Dis ; 10(12)2023 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-38132648

RESUMEN

Blood pressure (BP) dynamics during graded exercise testing provide important insights into cardiovascular health, particularly in athletes. These measurements, taken during intense physical exertion, complement and often enhance our understanding beyond traditional resting BP measurements. Historically, the challenge has been to distinguish 'normal' from 'exaggerated' BP responses in the athletic environment. While basic guidelines have served their purpose, they may not fully account for the complex nature of BP responses in today's athletes, as illuminated by contemporary research. This review critically evaluates existing guidelines in the context of athletic performance and cardiovascular health. Through a rigorous analysis of the current literature, we highlight the multifaceted nature of exercise-induced BP fluctuations in athletes, emphasising the myriad determinants that influence these responses, from specific training regimens to inherent physiological nuances. Our aim is to advocate a tailored, athlete-centred approach to BP assessment during exercise. Such a paradigm shift is intended to set the stage for evidence-based guidelines to improve athletic training, performance and overall cardiovascular well-being.

9.
Eur Heart J Case Rep ; 5(8): ytab184, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34514297

RESUMEN

BACKGROUND: Refractory angina pectoris (AP) significantly impairs quality of life in patients with chronic coronary syndrome. Several minimally invasive methods (coronary sinus reducer, cell therapy, laser or shockwave revascularization, and spinal cord stimulation) or non-invasive methods (external counterpulzation) have been studied. However, their routine clinical use has not been widely implemented. Surgical or endoscopic sympathectomy is feasible for permanently relieving angina, but is often contraindicated due to the extent of complications associated with it. Neuromodulation by anaesthetic blockade of the left-sided stellate ganglion (SG) has been shown to relieve angina for days or weeks. To provide a long-term anti-anginal effect, novel pharmacological (phenol-based) or radiofrequency ablation techniques have been individually used to permanently destroy sympathetic pathways. CASE SUMMARY: We describe a first-in-man use of stereotactic radiosurgical SG ablation using a linear accelerator (CyberKnife) in a heart failure patient after myocardial infarction with chronic refractory AP. Repeated anaesthetic SG blockade in this patient resulted in a significant, but only short-term, clinical improvement. The left, and subsequently the right, SG was ablated by targeted irradiation. During the 1-year follow-up, the patient remained without angina. We did not observe any clinically relevant early or late complications. Atrial fibrillation that developed 2 months after the second procedure was deemed to be associated with a natural progression of co-existing heart failure. DISCUSSION: We conclude that stereotactic radiosurgical SG ablation has the potential to become a minimally invasive and low-risk procedure to treat refractory angina patients. However, this procedure needs to be evaluated in larger patient populations.

11.
J Interv Card Electrophysiol ; 22(1): 13-21, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18418704

RESUMEN

PURPOSE: We tested the hypothesis that electroanatomic pulmonary vein (PV) antra encircling for the PV isolation will improve the outcome in treatment of paroxysmal atrial fibrillation (PAF), compared with segmental PV isolation. METHODS: Fifty-four patients underwent segmental PV isolation (group 1) and 56 patients circumferential PV isolation (group 2) for symptomatic PAF in a randomized study. RESULTS: Following single ablation procedure, at the 48 +/- 8 month follow-up, 30 (56%) and 32 (57%) patients in groups 1 and 2 remained free of arrhythmia (P = 0.41). After repeat ablation, 43 (80%) and 45 (80%) patients in groups 1 and 2 were free of arrhythmia without antiarrhythmic drugs (AADs); 48 (89%) and 51 (91%) patients in groups 1 and 2 did not have arrhythmia recurrences without or with AADs. CONCLUSION: This study demonstrates no advantage in long-term arrhythmia-free clinical outcome after circumferential PV isolation in patients with frequent PAF.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Adulto , Anciano , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Retratamiento
12.
J Interv Card Electrophysiol ; 23(3): 189-98, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18839297

RESUMEN

PURPOSE: The aim of the study was to identify variables associated with successful long-term maintenance of sinus rhythm (SR) after a single ablation of long-lasting persistent atrial fibrillation (AF). METHODS: Complex left atrial (LA) ablation was performed in 100 patients. Restoration of SR by ablation was the desired procedure endpoint. RESULTS: SR was restored by ablation in 38 patients during the first procedure. Following one ablation, 50 patients remained in SR for 31 +/- 14 months. SR maintenance was associated with shorter duration of the persistent AF (median 14 vs. 22 months; P = 0.05), lower proportion of the LA points exhibiting voltage <0.2 mV (median 20% vs. 33%; P = 0.006), and higher proportion of LA points showing voltage >1 mV (median 15% vs. 11%; P = 0.02). CONCLUSION: Among clinical variables, shorter duration of persistent AF and higher voltage recorded around the LA predicted long-term maintenance of SR after single ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Adulto , Anciano , Fibrilación Atrial/fisiopatología , Distribución de Chi-Cuadrado , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadísticas no Paramétricas , Resultado del Tratamiento
13.
J Cardiovasc Electrophysiol ; 18(8): 824-32, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17537207

RESUMEN

INTRODUCTION: Atrial macroreentry tachycardia (AMRT) in patients without obvious structural heart disease or previous surgical or catheter intervention has not been characterized in detail. METHODS AND RESULTS: Electroanatomical mapping and ablation of right or left AMRT were performed in 33 patients. Right atrial central conduction obstacle was formed by an electrically silent area (ESA) in 15 (68%) patients and by a line of double potentials (DPs) in seven (32%) patients. Left atrial ESAs were found in all 11 patients with the left AMRT. Reentry circuit was reconstructed in 19 (86%) patients with right AMRT and seven (64%) patients with left AMRT. Of the ESA-related right AMRT, eight (50%) were double-loop reentry circuits utilizing a narrow critical isthmus within the ESA and eight (50%) were single-loop reentry circuits with a critical isthmus bounded by ESA and either ostium of the vena cava. Single-loop DP-related AMRTs had the critical isthmus between the DP line and the ostium of the inferior vena cava (IVC). Left AMRTs included a variety of single-, double-, or triple-loop reentry circuits and their critical isthmuses. During the 37 +/- 15 month follow-up, atrial tachyarrhythmia-free clinical outcome was achieved in 21 (95%) patients (18 patients, 82%, without antiarrhythmic drugs) with the right AMRT and in nine (82%) patients (six patients, 55%, without antiarrhythmic drugs) with the left AMRT. CONCLUSION: The majority of right and left AMRTs were related to the presence of ESA. Ablation can be successful with a favorable risk of atrial tachyarrhythmia recurrence.


Asunto(s)
Mapeo del Potencial de Superficie Corporal , Ablación por Catéter , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Conducción Cardíaco/cirugía , Taquicardia Atrial Ectópica/fisiopatología , Taquicardia Atrial Ectópica/cirugía , Anciano , Cateterismo Cardíaco , Femenino , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Atrial Ectópica/complicaciones , Resultado del Tratamiento , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/fisiopatología
14.
PLoS One ; 11(3): e0152553, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27023918

RESUMEN

BACKGROUND: Left atrial (LA) enlargement is a predictor of worse outcome after catheter ablation for atrial fibrillation (AF). Widely used two-dimensional (2D)-echocardiography is inaccurate and underestimates real LA volume (LAV). We hypothesized that baseline clinical characteristics of patients can be used to adjust 2D-ECHO indices of LAV in order to minimize this disagreement. METHODS: The study enrolled 535 patients (59 ± 9 years; 67% males; 43% paroxysmal AF) who underwent catheter ablation for AF in three specialized centers. We investigated multivariately the relationship between 2D-echocardiographic indices of LA size, specifically LA diameter in M-mode in the parasternal long-axis view (LAD), LAV assessed by the prolate-ellipsoid method (LAVEllipsoid), LAV by the planimetric method (LAVPlanimetry), and LAV derived from 3D-electroanatomic mapping (LAVCARTO). RESULTS: Cubed LAD of 106 ± 45 ml, LAVEllipsoid of 72 ± 24 ml and LAVPlanimetry of 88 ± 30 ml correlated only modestly (r = 0.60, 0.69, and 0.53, respectively) with LAVCARTO of 137 ± 46 ml, which was significantly underestimated with a bias (±1.96 standard deviation) of -31 (-111; +49) ml, -64 (-132; +2) ml, and -49 (-125; +27) ml, respectively; p < 0.0001 for their mutual difference. LA enlargement itself, age, gender, type of AF, and the presence of structural heart disease were independent confounders of measurement error of 2D-echocardiographic LAV. CONCLUSION: Accuracy and precision of all 2D-echocardiographic LAV indices are poor. Their agreement with true LAV can be significantly improved by multivariate adjustment to clinical characteristics of patients.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Ecocardiografía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Imagenología Tridimensional , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Tamaño de los Órganos , Curva ROC , Análisis de Regresión
15.
Heart Rhythm ; 12(4): 687-98, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25576779

RESUMEN

BACKGROUND: The impact of restoring sinus rhythm (SR) by initial ablation in patients with long-standing persistent atrial fibrillation (LSPAF) is not fully established. OBJECTIVE: The purpose of this study was to investigate the prognostic value of SR restoration at the initial procedure and arrhythmia noninducibility at the final repeat procedure for long-term outcome. METHODS: A total of 203 patients (22% female; age 59 ± 9 years) underwent stepwise catheter ablation for LSPAF. RESULTS: The procedural end-point of SR restoration was achieved in 50% of patients. During follow-up (median 48 months) and after 1.7 procedures per patient, 72% of patients were free from arrhythmia off antiarrhythmic drugs. Failure to restore SR was independently predicted by left atrial (LA) long-axis diameter ≥68 mm (relative risk [RR] 1.55, P = .03], proportion of high-voltage LA sites <20% (RR 1.62, P = .02), and left atrial appendage (LAA) atrial fibrillation cycle length (AFCL) <155 ms (RR 1.5, P = .05). Arrhythmia recurrence after the initial procedure was predicted by SR nonrestoration (RR 2.99, P <.000001) and LAA AFCL ≥155 ms (RR 1.90, P = .0002). Arrhythmia recurrence after the final procedure was predicted by SR nonrestoration at the initial procedure (RR 2.83, P = .0007), persistent AF duration ≥24 months (RR 2.74, P = .002), LAA outflow velocity <40 cm/s (RR 2.21, P = .006), and LAA AFCL ≥155 ms (RR 1.92, P = .02). In 115 patients with repeat procedure(s), failure to achieve arrhythmia noninducibility at the final procedure (19% of patients) was associated with arrhythmia recurrence (RR 8.9, P < .000001). CONCLUSION: SR restoration at the initial procedure and arrhythmia noninducibility at the last repeat procedure were major predictors of arrhythmia-free outcome after ablation for LSPAF.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial , Ablación por Catéter , Complicaciones Posoperatorias , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , República Checa/epidemiología , Supervivencia sin Enfermedad , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/terapia , Pronóstico , Estudios Prospectivos , Recurrencia , Sistema de Registros , Reoperación , Medición de Riesgo , Tiempo , Resultado del Tratamiento
16.
J Am Heart Assoc ; 3(4)2014 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-25037195

RESUMEN

BACKGROUND: Changes in quality of life (QoL) after catheter ablation for long-standing persistent atrial fibrillation (LSPAF) are not well described. We sought to compare QoL improvement after catheter ablation of paroxysmal atrial fibrillation (PAF) versus that after LSPAF. METHODS AND RESULTS: A total of 261 PAF and 126 LSPAF ablation recipients were prospectively followed for arrhythmia recurrence, QoL, hospital stay, and sick leave. In PAF versus LSPAF groups, 1.3±0.6 versus 1.6±0.7 procedures were performed per patient (P<0.00001) during a 3-year follow-up. Good arrhythmia control was achieved in 86% versus 87% of patients (P=0.69) and in 69% versus 69% of patients not receiving antiarrhythmic drugs (P=0.99). The baseline QoL was better in the PAF than in the LSPAF group (European Quality of Life Group instrument self-report questionnaire visual analog scale: 66.4±14.2 versus 61.0±14.2, P=0.0005; European Quality of Life Group 3-level, 5-dimensional descriptive system: 71.4±9.2 versus 67.7±13.8, P=0.002). Postablation 3-year increase in QoL was significant in both groups (all P<0.00001) and significantly lower in PAF versus LSPAF patients (visual analog scale: +5.0±14.5 versus +10.2±12.8, P=0.001; descriptive system: +5.9±14.3 versus +9.3±13.9, P=0.03). In multivariate analysis, LSPAF, less advanced age, shorter history of AF and good arrhythmia control were consistently associated with postablation 3-year improvement in QoL. Days of hospital stay for cardiovascular reasons and days on sick leave per patient/year were significantly reduced in both groups. CONCLUSIONS: Patients with LSPAF had worse baseline QoL. The magnitude of QoL improvement after ablation of LSPAF was significantly greater compared with after ablation of PAF, particularly when good arrhythmia control was achieved without the use of antiarrhythmic drugs.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Calidad de Vida , Ausencia por Enfermedad/estadística & datos numéricos , Actividades Cotidianas , Adulto , Anciano , Ansiedad , Fibrilación Atrial/fisiopatología , Estudios de Cohortes , Depresión , Femenino , Estudios de Seguimiento , Hospitalización/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA