Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
MMWR Morb Mortal Wkly Rep ; 67(11): 333-336, 2018 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-29565842

RESUMEN

Hurricane Maria made landfall in Puerto Rico on September 20, 2017, causing major damage to infrastructure and severely limiting access to potable water, electric power, transportation, and communications. Public services that were affected included operations of the Puerto Rico Department of Health (PRDOH), which provides critical laboratory testing and surveillance for diseases and other health hazards. PRDOH requested assistance from CDC for the restoration of laboratory infrastructure, surveillance capacity, and diagnostic testing for selected priority diseases, including influenza, rabies, leptospirosis, salmonellosis, and tuberculosis. PRDOH, CDC, and the Association of Public Health Laboratories (APHL) collaborated to conduct rapid needs assessments and, with assistance from the CDC Foundation, implement a temporary transport system for shipping samples from Puerto Rico to the continental United States for surveillance and diagnostic and confirmatory testing. This report describes the initial laboratory emergency response and engagement efforts among federal, state, and nongovernmental partners to reestablish public health laboratory services severely affected by Hurricane Maria. The implementation of a sample transport system allowed Puerto Rico to reinitiate priority infectious disease surveillance and laboratory testing for patient and public health interventions, while awaiting the rebuilding and reinstatement of PRDOH laboratory services.


Asunto(s)
Tormentas Ciclónicas , Desastres , Laboratorios/organización & administración , Práctica de Salud Pública , Centers for Disease Control and Prevention, U.S. , Enfermedades Transmisibles/diagnóstico , Enfermedades Transmisibles/epidemiología , Pruebas Diagnósticas de Rutina , Humanos , Vigilancia de la Población , Puerto Rico/epidemiología , Estados Unidos
2.
Public Health Rep ; 138(3): 428-437, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36960828

RESUMEN

Early during the COVID-19 pandemic, the Centers for Disease Control and Prevention (CDC) leveraged an existing surveillance system infrastructure to monitor COVID-19 cases and deaths in the United States. Given the time needed to report individual-level (also called line-level) COVID-19 case and death data containing detailed information from individual case reports, CDC designed and implemented a new aggregate case surveillance system to inform emergency response decisions more efficiently, with timelier indicators of emerging areas of concern. We describe the processes implemented by CDC to operationalize this novel, multifaceted aggregate surveillance system for collecting COVID-19 case and death data to track the spread and impact of the SARS-CoV-2 virus at national, state, and county levels. We also review the processes established to acquire, process, and validate the aggregate number of cases and deaths due to COVID-19 in the United States at the county and jurisdiction levels during the pandemic. These processes include time-saving tools and strategies implemented to collect and validate authoritative COVID-19 case and death data from jurisdictions, such as web scraping to automate data collection and algorithms to identify and correct data anomalies. This topical review highlights the need to prepare for future emergencies, such as novel disease outbreaks, by having an event-agnostic aggregate surveillance system infrastructure in place to supplement line-level case reporting for near-real-time situational awareness and timely data.


Asunto(s)
COVID-19 , Humanos , Estados Unidos/epidemiología , COVID-19/epidemiología , SARS-CoV-2 , Pandemias/prevención & control , Brotes de Enfermedades , Centers for Disease Control and Prevention, U.S.
3.
J Am Med Inform Assoc ; 29(10): 1807-1809, 2022 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-35666140

RESUMEN

During the coronavirus disease-2019 (COVID-19) pandemic, the Centers for Disease Control and Prevention (CDC) supplemented traditional COVID-19 case and death reporting with COVID-19 aggregate case and death surveillance (ACS) to track daily cumulative numbers. Later, as public health jurisdictions (PHJs) revised the historical COVID-19 case and death data due to data reconciliation and updates, CDC devised a manual process to update these records in the ACS dataset for improving the accuracy of COVID-19 case and death data. Automatic data transfer via an application programming interface (API), an intermediary that enables software applications to communicate, reduces the time and effort in transferring data from PHJs to CDC. However, APIs must meet specific content requirements for use by CDC. As of March 2022, CDC has integrated APIs from 3 jurisdictions for COVID-19 ACS. Expanded use of APIs may provide efficiencies for COVID-19 and other emergency response planning efforts as evidenced by this proof-of-concept. In this article, we share the utility of APIs in COVID-19 ACS.


Asunto(s)
COVID-19 , Centers for Disease Control and Prevention, U.S. , Humanos , Pandemias/prevención & control , Salud Pública , Programas Informáticos , Estados Unidos/epidemiología
4.
J Clin Microbiol ; 49(6): 2210-5, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21471339

RESUMEN

Swine origin 2009 H1N1 influenza virus has spread globally to cause the first influenza pandemic of the 21st century. Serological studies can improve our understanding of the extent of human infection and risk factors associated with the transmission of this pandemic virus. The "gold standard" for serodiagnosis of human influenza virus infection is the detection of seroconversion between acute- and convalescent-stage samples. However, the timing of seroepidemiological investigations often precludes the collection of truly acute-phase sera, requiring development of serological criteria for evaluating convalescent-phase sera that optimize detection of true positives and true negatives. To guide seroepidemiological investigations into the spread of the novel 2009 pandemic H1N1 virus, we characterized serum antibody responses to 2009 H1N1 virus in 87 individuals with confirmed viral infection and 227 nonexposed U.S. individuals using microneutralization (MN) and hemagglutination inhibition (HI) assays. Sensitivity and specificity were determined for each assay alone and in combination for detection of 2009 H1N1 virus-specific antibodies in convalescent-phase sera. Although the HI assay was more specific for detecting antibody to 2009 H1N1, the MN assay was more sensitive, particularly for detecting low-titer seroconversions. A combination of titers (MN ≥ 40 and HI ≥ 20) provided the highest sensitivity (90%) and specificity (96%) for individuals aged <60 years and 92% specificity for adults aged ≥ 60 years for detection of serologically confirmed 2009 H1N1 infections in U.S. populations during the first pandemic waves. These studies provide an approach to optimize timely serological investigations for future pandemics or outbreaks of novel influenza viruses among humans.


Asunto(s)
Subtipo H1N1 del Virus de la Influenza A/aislamiento & purificación , Gripe Humana/diagnóstico , Virología/métodos , Adolescente , Adulto , Anciano , Animales , Anticuerpos Antivirales/sangre , Niño , Preescolar , Pruebas de Inhibición de Hemaglutinación , Humanos , Lactante , Subtipo H1N1 del Virus de la Influenza A/inmunología , Persona de Mediana Edad , Pruebas de Neutralización , Sensibilidad y Especificidad , Pruebas Serológicas/métodos , Estados Unidos , Adulto Joven
5.
Public Health Rep ; 136(5): 554-561, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34139910

RESUMEN

OBJECTIVES: Federal open-data initiatives that promote increased sharing of federally collected data are important for transparency, data quality, trust, and relationships with the public and state, tribal, local, and territorial partners. These initiatives advance understanding of health conditions and diseases by providing data to researchers, scientists, and policymakers for analysis, collaboration, and use outside the Centers for Disease Control and Prevention (CDC), particularly for emerging conditions such as COVID-19, for which data needs are constantly evolving. Since the beginning of the pandemic, CDC has collected person-level, de-identified data from jurisdictions and currently has more than 8 million records. We describe how CDC designed and produces 2 de-identified public datasets from these collected data. METHODS: We included data elements based on usefulness, public request, and privacy implications; we suppressed some field values to reduce the risk of re-identification and exposure of confidential information. We created datasets and verified them for privacy and confidentiality by using data management platform analytic tools and R scripts. RESULTS: Unrestricted data are available to the public through Data.CDC.gov, and restricted data, with additional fields, are available with a data-use agreement through a private repository on GitHub.com. PRACTICE IMPLICATIONS: Enriched understanding of the available public data, the methods used to create these data, and the algorithms used to protect the privacy of de-identified people allow for improved data use. Automating data-generation procedures improves the volume and timeliness of sharing data.


Asunto(s)
COVID-19/epidemiología , Centers for Disease Control and Prevention, U.S./organización & administración , Confidencialidad/normas , Anonimización de la Información/normas , Centers for Disease Control and Prevention, U.S./normas , Humanos , Pandemias , SARS-CoV-2 , Estados Unidos/epidemiología
6.
Biologicals ; 38(6): 675-83, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20875951

RESUMEN

A two-stage, multilevel assay quality control (QC) system was designed and implemented for two high stringency QC anthrax serological assays; a quantitative anti-PA IgG enzyme-linked immunosorbent assay (ELISA) and an anthrax lethal toxin neutralization activity (TNA) assay. The QC system and the assays were applied for the congressionally mandated Centers for Disease Control and Prevention (CDC) Phase 4 human clinical trial of anthrax vaccine adsorbed (AVA, BioThrax). A total of 57,284 human serum samples were evaluated by anti-PA enzyme-linked immunosorbent assay (ELISA) and 11,685 samples by anthrax lethal toxin neutralization activity (TNA) assay. The QC system demonstrated overall sample acceptance rates of 86% for ELISA and 90% for the TNA assays respectively. Monitoring of multiple assay and test sample variables showed no significant long term trends or degradation in any of the critical assay reagents or reportable values for both assays. Assay quality control data establish the functionality of the quality control system and demonstrates the reliability of the serological data generated using these assays.


Asunto(s)
Vacunas contra el Carbunco/uso terapéutico , Ensayos Clínicos como Asunto , Control de Calidad , Vacunas contra el Carbunco/administración & dosificación , Vacunas contra el Carbunco/inmunología , Antígenos Bacterianos/inmunología , Toxinas Bacterianas/inmunología , Centers for Disease Control and Prevention, U.S. , Ensayo de Inmunoadsorción Enzimática , Humanos , Pruebas de Neutralización , Estados Unidos
7.
J Immunol Methods ; 333(1-2): 89-106, 2008 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-18304568

RESUMEN

Quantification of anthrax lethal toxin (LTx) neutralization activity (TNA) is pivotal in assessing protective antibody responses to anthrax vaccines and for evaluation of immunotherapies for anthrax. We have adapted and redesigned the TNA assay to establish a unifying, standardized, quantitative and validated technology platform for LTx neutralization in the J774A.1 murine cell line. Critical design features of this platform are 1) the application of a free-form or constrained 4 parameter logistic (4-PL) function to model neutralization responses within and between boundary limits of 100% cell survival and 95% cell lysis and 2) to exploit innovative assay curve recognition algorithms for interpretive endpoints. The assay was validated using human serum ED50 (dilution of serum effecting 50% neutralization) as the primary reportable value (RV). Intra-operator and intermediate precision, expressed as the coefficient of variation (%CV), were high at 10.5-15.5%CV and 13.5-14.5%CV respectively. TNA assay dilutional linearity was demonstrated for human sera using linear regression analysis of log(10) transformed data with slope=0.99, intercept=-0.03 and r(2)=0.985. Assay accuracy, inferred from the precision and linearity data and using a spike-recovery approach, was high with a percent error (%E) range of only 3.4-20.5%E. The lower limit of detection (LLOD) was ED50=12 and the lower limit of quantification (LLOQ) was ED50=36. The cell-based assay was robust, tolerating incubation temperatures from 35 to 39 degrees C, CO(2) concentrations from 3% to 7% and reporter substrate (MTT) concentrations of 2.5-7.5 mg/ml. Strict assay quality control parameters were met for up to 25 cell culture passages. The long term (50 month) assay stability, determined using human reference standards AVR414 and AVR801, indicated high precision, consistent accuracy and no detectable assay drift. A customized software program provided two additional assay metrics, Quantification Titer (QT) and Threshold Titer (TT), both of which demonstrate acceptable accuracy, precision and dilutional linearity. The TT was also used to establish the assay reactivity threshold (RT). The application of the assay to sera from humans, Rhesus macaques and rabbits was demonstrated separately and by aggregate dilutional linearity analysis of the ED50 (slope=0.98, intercept=0.003, r(2)=0.989). We propose this TNA assay format with a qualified standard reference serum and customized interpretive software as a unifying platform technology for determination of functional serologic responses to anthrax vaccines and for evaluation of anthrax immunotherapeutics.


Asunto(s)
Carbunco/inmunología , Anticuerpos Antibacterianos/inmunología , Antígenos Bacterianos/inmunología , Bacillus anthracis/inmunología , Toxinas Bacterianas/inmunología , Modelos Inmunológicos , Pruebas de Neutralización/métodos , Animales , Carbunco/prevención & control , Vacunas contra el Carbunco/inmunología , Línea Celular , Humanos , Macaca mulatta , Ratones , Conejos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
JAMA ; 300(13): 1532-43, 2008 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-18827210

RESUMEN

CONTEXT: In 1999, the US Congress directed the Centers for Disease Control and Prevention to conduct a pivotal safety and efficacy study of anthrax vaccine adsorbed (AVA). OBJECTIVE: To determine the effects on serological responses and injection site adverse events (AEs) resulting from changing the route of administration of AVA from subcutaneous (s.q.) to intramuscular (i.m.) and omitting the week 2 dose from the licensed schedule. DESIGN, SETTING, AND PARTICIPANTS: Assessment of the first 1005 enrollees in a multisite, randomized, double-blind, noninferiority, phase 4 human clinical trial (ongoing from May 2002). INTERVENTION: Healthy adults received AVA by the s.q. (reference group) or i.m. route at 0, 2, and 4 weeks and 6 months (4-SQ or 4-IM; n = 165-170 per group) or at a reduced 3-dose schedule (3-IM; n = 501). A control group (n = 169) received saline injections at the same time intervals. MAIN OUTCOME MEASURES: Noninferiority at week 8 and month 7 of anti-protective antigen IgG geometric mean concentration (GMC), geometric mean titer (GMT), and proportion of responders with a 4-fold rise in titer (%4 x R). Reactogenicity outcomes were proportions of injection site and systemic AEs. RESULTS: At week 8, the 4-IM group (GMC, 90.8 microg/mL; GMT, 1114.8; %4 x R, 97.7) was noninferior to the 4-SQ group (GMC, 105.1 microg/mL; GMT, 1315.4; %4 x R, 98.8) for all 3 primary end points. The 3-IM group was noninferior for only the %4 x R (GMC, 52.2 microg/mL; GMT, 650.6; %4 x R, 94.4). At month 7, all groups were noninferior to the licensed regimen for all end points. Solicited injection site AEs assessed during examinations occurred at lower proportions in the 4-IM group compared with 4-SQ. The odds ratio for ordinal end point pain reported immediately after injection was reduced by 50% for the 4-IM vs 4-SQ groups (P < .001). Route of administration did not significantly influence the occurrence of systemic AEs. CONCLUSIONS: The 4-IM and 3-IM regimens of AVA provided noninferior immunological priming by month 7 when compared with the 4-SQ licensed regimen. Intramuscular administration significantly reduced the occurrence of injection site AEs. Trial Registration clinicaltrials.gov Identifier: NCT00119067.


Asunto(s)
Vacunas contra el Carbunco/administración & dosificación , Vacunas contra el Carbunco/inmunología , Adulto , Vacunas contra el Carbunco/efectos adversos , Anticuerpos Antibacterianos/inmunología , Bacillus anthracis/inmunología , Método Doble Ciego , Esquema de Medicación , Femenino , Humanos , Inmunoglobulina G/inmunología , Inyecciones Intramusculares , Inyecciones Subcutáneas , Masculino , Persona de Mediana Edad
9.
Hemodial Int ; 11(3): 349-53, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17576301

RESUMEN

Guidelines recommend that > or =50% of patients starting dialysis have a fistula. We reviewed our experience in consecutive incident patients over a 1-year period. Only 30 of the 93 patients starting hemodialysis had a fistula that was accessed. Late referral (nephrology contact <90 days) was a significant issue in 48% (30/63) of the patients without a fistula. Most (n=21) of the late referrals were acute disease; only 9 were late referrals of chronic disease. Nephrology follow-up exceeded 200 days in the remaining (33/63) without this access. In the cohort with sufficient nephrology referral, we explored variables associated with a fistula (n=30) compared with those without one (n=33). In multivariate logistic regression analysis, peripheral vascular disease (odds ratio [OR] 0.026, 95% confidence interval [CI] 0.002-0.286) and rapid loss of estimated glomerular filtration rate (eGFR) (OR 0.745 per mL/min/1.73 m(2)/year, 95% CI 0.625-0.888) in the year preceding dialysis were significant negative predictors for a fistula. Patients without access experienced faster declines in GFR in the year preceding dialysis (12.1+/-9.9 vs. 4.7+/-3.5 mL/min 1.73 m(2) with access, p<0.001). Glomerular filtration rate loss in the 2 years before starting dialysis was the same between the 2 groups (-0.54+/-10.4 vs. 1.42+/-3.9 mL/min 1.73 m(2)). Age, sex, diabetes, other comorbidity, length of nephrology follow-up, eGFR at dialysis start, hemoglobin, and albumin were not significant. At our center, rapid loss of renal function in otherwise stable chronic kidney disease (CKD) patients is more important than late referral of CKD for the lack of access. Improvements in rapid referral for access creation could help reduce this barrier.


Asunto(s)
Cateterismo , Tasa de Filtración Glomerular , Diálisis Renal , Insuficiencia Renal Crónica/fisiopatología , Insuficiencia Renal Crónica/terapia , Adulto , Anciano , Cateterismo/efectos adversos , Catéteres de Permanencia/efectos adversos , Femenino , Estudios de Seguimiento , Hemoglobinas/análisis , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Diálisis Renal/efectos adversos , Insuficiencia Renal Crónica/sangre , Insuficiencia Renal Crónica/complicaciones , Albúmina Sérica/análisis , Enfermedades Vasculares/sangre , Enfermedades Vasculares/etiología , Enfermedades Vasculares/fisiopatología
10.
J Clin Virol ; 27(1): 90-6, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12727534

RESUMEN

BACKGROUND: The use of pooled specimens has been proposed as a means of expanding testing for human immunodeficiency virus (HIV) antibodies in population studies and in blood screening, while reducing laboratory costs. OBJECTIVES: To develop a strategic specimen pooling method to be used with rapid HIV antibody assays to detect positive specimens and to evaluate its performance in comparison with testing with commercial EIA and WB. STUDY DESIGN: Two lateral flow rapid HIV antibody assays, Seroz*Strip HIV-1/2(1) and Determine HIV-1/2, were evaluated for their ability to detect HIV-1 antibodies in serum and/or plasma specimens pooled in sizes ranging from two to 20 following the respective manufacturers' protocols. One thousand prospectively collected specimens and 55 seroconversion specimens were prepared in pools of five for evaluation by the two rapid HIV assays. RESULTS: Optimal detection and discrimination of HIV-1 antibody-positive and HIV-1 antibody-negative specimens was observed in pool sizes of five to ten for both assays. The ability of the two rapid assays to detect HIV-1 antibody-positive samples from commercial HIV-1 seroconversion panels contained in the pools was equivalent to that of commercial enzyme immunoassays (EIAs) and Western blot (WB) to detect HIV-1 antibody in the non-pooled samples. Application of the pooling method in prospectively collected specimens yielded excellent concordance with EIA/WB results in both sensitivity (98.88% for Seroz*Strip HIV-1/2, 100% for Determine HIV-1/2) and specificity (99.56% for Seroz*Strip HIV-1/2, 99.45% for Determine HIV-1/2). CONCLUSION: Use of a pooling strategy with either assay reduced the number of tests required by almost 50% and could provide substantial cost reductions for HIV screening in settings where HIV-1 prevalence is less than 10%.


Asunto(s)
Serodiagnóstico del SIDA , Anticuerpos Anti-VIH/sangre , Infecciones por VIH/diagnóstico , VIH-1/inmunología , VIH-2/inmunología , Serodiagnóstico del SIDA/economía , Western Blotting , Infecciones por VIH/epidemiología , Seropositividad para VIH , Seroprevalencia de VIH , Humanos , Técnicas para Inmunoenzimas , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad , Factores de Tiempo
11.
J Immunol Methods ; 408: 78-88, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24857756

RESUMEN

Inhalation anthrax is a rare but acute infectious disease following adsorption of Bacillus anthracis spores through the lungs. The disease has a high fatality rate if untreated, but early and correct diagnosis has a significant impact on case patient recovery. The early symptoms of inhalation anthrax are, however, non-specific and current anthrax diagnostics are primarily dependent upon culture and confirmatory real-time PCR. Consequently, there may be a significant delay in diagnosis and targeted treatment. Rapid, culture-independent diagnostic tests are therefore needed, particularly in the context of a large scale emergency response. The aim of this study was to evaluate the ability of monoclonal antibodies to detect anthrax toxin proteins that are secreted early in the course of B. anthracis infection using a time-resolved fluorescence (TRF) immunoassay. We selected monoclonal antibodies that could detect protective antigen (PA), as PA83 and also PA63 and LF in the lethal toxin complex. The assay reliable detection limit (RDL) was 6.63×10(-6)µM (0.551ng/ml) for PA83 and 2.51×10(-5)µM (1.58ng/ml) for PA63. Despite variable precision and accuracy of the assay, PA was detected in 9 out of 10 sera samples from anthrax confirmed case patients with cutaneous (n=7), inhalation (n=2), and gastrointestinal (n=1) disease. Anthrax Immune Globulin (AIG), which has been used in treatment of clinical anthrax, interfered with detection of PA. This study demonstrates a culture-independent method of diagnosing anthrax through the use of monoclonal antibodies to detect PA and LF in the lethal toxin complex.


Asunto(s)
Carbunco/diagnóstico , Anticuerpos Monoclonales , Antígenos Bacterianos/sangre , Bacillus anthracis/inmunología , Toxinas Bacterianas/sangre , Europio , Inmunoensayo/métodos , Carbunco/sangre , Carbunco/inmunología , Vacunas contra el Carbunco/inmunología , Biomarcadores/sangre , Estudios de Casos y Controles , Diagnóstico Precoz , Fluoroinmunoensayo , Humanos , Límite de Detección , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
12.
Clin Diagn Lab Immunol ; 12(8): 918-21, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16085908

RESUMEN

Assay protocols of three rapid human immunodeficiency virus (HIV) assays, OraQuick-1/2, SeroStrip-1/2, and Determine-1/2, were modified to detect recent HIV seroconversion using a higher dilution of serum specimens. Optimal predilution of specimens resulted in negative test results during early periods of seroconversion (about 6 months), when antibody levels were low. A total of 269 seropositive specimens from routine HIV type 1 testing and from commercial sources (low-titer and seroconversion panels) were tested, and results were recorded as negative (score=0) or positive using intensity scores from 0.5 (weak positive) to 4 (strongly positive). The same specimens were previously tested by a less sensitive (LS) enzyme immunoassay (EIA), Abbott 3A 11-LS, and were classified as recent or long-term infections based on the standardized optical density (SOD) cutoff of 0.75. Overall concordance of >94% was observed between 3A 11-LS and modified rapid tests (RT-LSs) for detecting and distinguishing recent HIV seroconversion from long-term HIV infection (kappa statistics=0.894 to 0.901). Moreover, intensity scores on RT-LSs correlated well with median 3A 11-LS SOD values (R(2)>0.98). Our results indicate that rapid HIV tests can be modified to detect recent seroconversion with results comparable to those from less sensitive EIA.


Asunto(s)
Anticuerpos Anti-VIH/sangre , Infecciones por VIH/diagnóstico , Infecciones por VIH/inmunología , Seropositividad para VIH/diagnóstico , VIH-1/inmunología , Anticuerpos Antivirales/sangre , Seropositividad para VIH/inmunología , Humanos , Juego de Reactivos para Diagnóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Pruebas Serológicas/métodos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA