1.
J Orthop Sci ; 24(1): 128-135, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30322622

RESUMEN

PURPOSE: Several navigation-based kinematic studies of the knee have been published recently, but little information is available about reproducibility and reliability of the acquired data. The aim of the present study first is to determine reproducibility and reliability of kinematical measurements of healthy knees and knees after TKA (total knee arthroplasty) with regards to rotational and translational measurement parameters. Second the mathematical background, applicability, and limitations of investigating navigation-based kinematics should be compiled. METHODS: Using cadavers fixed by the Thiel method, in ten knees reproducibility of obtained angular and translational kinematic parameters were investigated before and after total knee arthroplasty. For this reason agreement of obtained data of a first and a second movement cycle and the same after a surgical intervention was assessed using a commercially available navigational device. RESULTS: For both angular and translational parameters in healthy knees and knees after total knee arthroplasty mean differences between measured parameters of the first and second movement cycle and after surgical intervention of less than 0.5° or millimeters (standard deviation 1.3 or less) or a inter class correlation of 0.92 and more, respectively, was found. DISCUSSION: Use of a commercial navigation system allows highly accurate investigations of knee kinematics in cadavers before and after TKA. This technique, which does not require any specific technical knowledge of the investigator, is in accordance with current accepted biomechanical methods.


Asunto(s)
Articulación de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/diagnóstico por imagen , Rango del Movimiento Articular/fisiología , Anciano , Artroplastia de Reemplazo de Rodilla , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Masculino , Osteoartritis de la Rodilla/fisiopatología , Reproducibilidad de los Resultados
2.
Int Orthop ; 41(10): 2037-2044, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28550426

RESUMEN

PURPOSE: Our aim was to compare the long-term outcome between navigated and conventional total knee arthroplasty (TKA), which is currently not known. METHODS: Long-term survivorship, clinical scores and radiographic results of a matched-pair group of 350 patients (350 knees) treated with navigated (n = 157) or conventional (n = 188) TKA for osteoarthritis over a period of 11 years were reviewed retrospectively. RESULTS: The mean clinical follow-up was ten years. There were no clinically relevant differences with respect to any clinical outcome, patient satisfaction or pain between the two groups. Coronal leg alignment was closer (1.7-3.1°) to the neutral mechanical axis in the navigated group compared with the conventional group (2.6-4.7°). A total of 12 knees (6.4%) in the conventional group and three (1.9%) in the navigated group underwent revision surgery (p = 0.04), resulting in an absolute risk reduction of 4.5% for revision surgery by using navigation. Using any revision as an end point, the ten-year Kaplan-Meier survivorship was 98.1% in the navigated and 92.5% in the conventional group. CONCLUSIONS: Navigated TKA improves implant survivorship compared with conventional TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/cirugía , Cirugía Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Masculino , Análisis por Apareamiento , Persona de Mediana Edad , Osteoartritis de la Rodilla/mortalidad , Satisfacción del Paciente/estadística & datos numéricos , Falla de Prótesis , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Análisis de Supervivencia , Supervivencia , Resultado del Tratamiento
3.
Knee Surg Sports Traumatol Arthrosc ; 24(8): 2407-14, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25399346

RESUMEN

PURPOSE: Component malrotation has a major impact on patellar kinematics in total knee arthroplasty. The influence of natural rotational limb alignment on patellar kinematics is unclear so far. Based on recent clinical investigations, we hypothesized that rotational limb alignment significantly influences patellar kinematics. METHODS: Patellar kinematics of ten cadaveric knees was measured using computer navigation during passive motion. Data were correlated with different rotational limb alignment parameters of preoperative CT scans. RESULTS: Femoral antetorsion showed a significant influence on patellar rotation, while tibial tubercle-posterior cruciate ligament distance additionally displayed a significant influence on patellar mediolateral shift (p < 0.05). Femoral posterior condylar angle was sensitive to patellar epicondylar distance, rotation and tilt (p < 0.05). Patellar rotation was influenced by five out of eight rotational limb alignment parameters (p < 0.05). CONCLUSIONS: Rotational limb alignment should be paid more attention in terms of clinical evaluation of patellar tracking and future biomechanical and clinical investigations.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Desviación Ósea , Rótula/fisiología , Rotación , Anciano , Fenómenos Biomecánicos , Femenino , Fémur/cirugía , Humanos , Técnicas In Vitro , Rodilla/cirugía , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Rótula/cirugía , Ligamento Cruzado Posterior/cirugía , Rango del Movimiento Articular , Tibia/cirugía , Tomografía Computarizada por Rayos X
4.
Knee Surg Sports Traumatol Arthrosc ; 24(3): 823-9, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26820967

RESUMEN

PURPOSE: Patellar maltracking due to incorrect component alignment is considered as a main reason for anterior knee pain after total knee arthroplasty (TKA). In contrast to coronal and axial component placement, the influence of sagittal component alignment on patellar kinematics has not been investigated so far. METHODS: In ten lower cadaveric limbs, TKAs were implanted using a commercial computer navigation system. In six knees, the femoral component was aligned in 5° and in four knees in 0° of flexion, respectively. Patellar kinematics were registered by means of a computer navigation system using an additional patella tracking array and correlated with femoral and tibial sagittal component alignment. RESULTS: Sagittal component alignment significantly altered patellar mediolateral shift (p < 0.05). In contrast, patellar epicondylar distance, rotation and tilt were not significantly influenced. CONCLUSIONS: Sagittal component alignment in TKA has a major impact on patellar kinematics and should therefore be considered while addressing tibiofemoral kinematics intraoperatively.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Rótula/fisiología , Ajuste de Prótesis , Fenómenos Biomecánicos/fisiología , Cadáver , Humanos , Modelos Lineales , Cirugía Asistida por Computador
5.
Knee Surg Sports Traumatol Arthrosc ; 24(8): 2453-60, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25682166

RESUMEN

PURPOSE: The intraoperative sagittal cutting block alignment when intramedullary alignment rods are used was investigated. Its absolute orthogonal orientation in relation to the mechanical femoral axis should be analysed. It was hypothesized that (1) alignment rods do not ensure a desired deviation within a range between 0° and 3° flexion as it has been shown to be favourable for clinical and functional outcome. Further, the degree of flexion cannot be (2) foreseen by the surgeon or (3) estimated by clinical or radiological parameters. METHODS: Forty knees allocated to total knee arthroplasty were included. The distal femoral cutting block was aligned using an intramedullary rod. By means of a navigation device, the sagittal alignment of the cutting block in degrees of flexion was measured. RESULTS: The mean measured flexion of the cutting block was 4.4° (3.6 SD). Twenty-five per cent (10/40) of the values were within a corridor between 0° and 3° of flexion. The mean difference between expected and measured flexion was -1.5° (-7.6 to 4.7 95 % limits of agreement). The dorsoventral diameter of the distal femur showed a significant influence on measured flexion (R (2) = 0.112, p = 0.035). CONCLUSION: Intramedullary alignment rods used in the present study do not ensure a distal cutting block alignment between 0° and 3° of flexion in relation to the femoral mechanical axis. The extent of flexion could not be foreseen either by the surgeon. The dorsoventral diameter of the distal femur correlated with measured flexion. However, only limited data is available on influence of femoral component flexion on implant failure or clinical and functional outcome. LEVEL OF EVIDENCE: Diagnostic study, Level II.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Desviación Ósea , Fémur/cirugía , Fijadores Internos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Rango del Movimiento Articular
6.
Int Orthop ; 40(4): 673-80, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26728611

RESUMEN

PURPOSE: This study investigated whether etoricoxib (COX-II blocker) has a superior efficacy of preventing heterotopic ossification (HO) after total hip arthroplasty (THA) compared to diclofenac (non-selective NSAID). METHODS: One hundred patients were included (50 in each group) in this single centre, prospective, double-blinded, randomized, controlled trial. Etoricoxib (90 mg) was administered once and diclofenac (75 mg) twice per day for a perioperative period of nine days. The incidence of HO was evaluated on radiographs of the pelvis six months after surgery. RESULTS: Eighty nine of 100 (89 %) patients could be analysed. The overall HO incidence was 37.8 %. There was no significant difference between both study groups. Twelve patients (27.3 %) of the DIC group and 13 patients (28.9 %) of the ETO group showed Brooker grade I ossifications. Five patients (11.4 %) of the DIC and four patients of the ETO (8.9 %) group showed grade II HO formations. No class III or IV HO formations occured in both groups. Ad hoc analysis detected a negative correlation between HO incidence and limited abduction and internal rotation of the hip. CONCLUSIONS: Etoricoxib and diclofenac are equally effective for oral HO prophylaxis after primary cementless THA when given for nine peri-operative days to ensure a full recovery and high patient satisfaction.


Asunto(s)
Antiinflamatorios no Esteroideos/uso terapéutico , Artroplastia de Reemplazo de Cadera/efectos adversos , Inhibidores de la Ciclooxigenasa 2/uso terapéutico , Diclofenaco/uso terapéutico , Osificación Heterotópica/prevención & control , Piridinas/uso terapéutico , Sulfonas/uso terapéutico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Antiinflamatorios no Esteroideos/efectos adversos , Inhibidores de la Ciclooxigenasa 2/efectos adversos , Diclofenaco/efectos adversos , Método Doble Ciego , Etoricoxib , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Osificación Heterotópica/etiología , Pelvis/diagnóstico por imagen , Pelvis/patología , Periodo Perioperatorio , Estudios Prospectivos , Piridinas/efectos adversos , Sulfonas/efectos adversos
7.
Int Orthop ; 40(12): 2495-2504, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27106215

RESUMEN

PURPOSE: In this prospective study of 135 patients undergoing cementless total hip arthroplasty (THA) we asked whether six current definitions of combined anteversion prevent impingement and increase postoperative patient individual impingement-free range-of-motion (ROM). METHODS: Implant position was measured by an independent, external institute on 3D-CT performed six weeks post-operatively. Post-operative ROM was calculated using a CT-based algorithm detecting osseous and/or prosthetic impingement by virtual hip movement. Additionally, clinical ROM was evaluated pre-operatively and one-year post-operatively by a blinded observer. RESULTS: Combined component position of cup and stem according to the definitions of Ranawat, Widmer, Dorr, Hisatome and Yoshimine inhibited prosthetic impingement in over 90 %, while combined osseous and prosthetic impingement still occurred in over 40 % of the cases. The recommendations by Jolles, Widmer, Dorr, Yoshimine and Hisatome enabled higher flexion (p ≤ 0.001) and internal rotation (p ≤ 0.006). Clinically, anteversion rules of Widmer and Yoshimine provided one-year post-operatively statistically but not clinically relevant higher internal rotation (p ≤0.034). CONCLUSION: Standard rules of combined anteversion detect prosthetic but fail to prevent combined osseous and prosthetic impingement in THA. Future models will have to account for the patient-individual anatomic situation to ensure impingement-free ROM.


Asunto(s)
Artroplastia de Reemplazo de Cadera/normas , Articulación de la Cadera/cirugía , Prótesis de Cadera/efectos adversos , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Articulación de la Cadera/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Artropatías/diagnóstico por imagen , Artropatías/etiología , Artropatías/prevención & control , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Rango del Movimiento Articular , Rotación , Técnicas Estereotáxicas , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X
8.
Arch Orthop Trauma Surg ; 136(5): 709-13, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26891850

RESUMEN

INTRODUCTION: Trabecular properties in osteonecrosis of the femoral head (ONFH) are altered for bone volume and structure in the femoral head and proximal femoral canal. We analysed the periprosthetic bone mineral density (BMD) as a correlate to bony ingrowth in patients with ONFH who received a cementless THA. MATERIALS AND METHODS: We performed a matched-pair analysis of 100 patients with ONFH (n = 50) and primary osteoarthritis (n = 50) who received the same, unilateral cementless THA. We compared the periprosthetic BMD 5 years after surgery by means of dual energy X-ray absorptiometry (DXA) analysing the seven femoral regions of interest (ROIs) according to Gruen. RESULTS: Within the ONFH group, significantly lower BMD values were found in the ROI 1 and 7 (p < 0.05). No statistically significant difference was found for ROIs 2-6. CONCLUSIONS: An altered periprosthetic bone stock in the proximal femur in patients with prior ONFH might be a possible risk factor for premature loosening of the femoral stem in THA. Surgeons need to consider coating and fixation philosophy of cementless implants when choosing the right stem for patients with ONFH.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Densidad Ósea , Necrosis de la Cabeza Femoral/cirugía , Fémur/fisiopatología , Fémur/cirugía , Osteoartritis de la Cadera/cirugía , Absorciometría de Fotón , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Enfermedades Óseas Metabólicas , Femenino , Fémur/diagnóstico por imagen , Cabeza Femoral/cirugía , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Necrosis de la Cabeza Femoral/fisiopatología , Estudios de Seguimiento , Articulación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/fisiopatología , Complicaciones Posoperatorias
9.
Brain Behav Immun ; 46: 180-91, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25736064

RESUMEN

OBJECTIVE: Density of sympathetic nerve fibers decreases in inflamed arthritic tissue tested by immunoreactivity towards tyrosine-hydroxylase (TH, catecholaminergic key enzyme). Since sympathetic nerve fibers may change phenotype from catecholaminergic to cholinergic (example: sweat glands), loss of nerve fibers may relate to undetectable TH. We aimed to investigate possible catecholaminergic-to-cholinergic transition of sympathetic nerve fibers in synovial tissue of animals with arthritis, and patients with rheumatoid arthritis (RA) and osteoarthritis (OA), and we wanted to find a possible transition factor. METHODS: Nerve fibers were detected by immunofluorescence towards TH (catecholaminergic) and vesicular acetylcholine transporter (cholinergic). Co-culture experiments with sympathetic ganglia and lymphocytes or osteoclast progenitors were designed to find stimulators of catecholaminergic-to-cholinergic transition (including gene expression profiling). RESULTS: In mouse joints, an increased density of cholinergic relative to catecholaminergic nerve fibers appeared towards day 35 after immunization, but most nerve fibers were located in healthy joint-adjacent skin or muscle and almost none in inflamed synovial tissue. In humans, cholinergic fibers are more prevalent in OA synovial tissue than in RA. Co-culture of sympathetic ganglia with osteoclast progenitors obtained from healthy but not from arthritic animals induced catecholaminergic-to-cholinergic transition. Osteoclast mRNA microarray data indicated that leukemia inhibitory factor (LIF) is a candidate transition factor, which was confirmed in ganglia experiments, particularly, in the presence of progesterone. CONCLUSION: In humans and mice, catecholaminergic-to-cholinergic sympathetic transition happens in less inflamed tissue but not in inflamed arthritic tissue. Under healthy conditions, presence of cholinergic sympathetic nerve fibers may support the cholinergic anti-inflammatory influence recently described.


Asunto(s)
Acetilcolina/metabolismo , Fibras Adrenérgicas/metabolismo , Artritis Reumatoide/metabolismo , Catecolaminas/metabolismo , Osteoartritis/metabolismo , Animales , Humanos , Masculino , Ratones , Sistema Nervioso Simpático/metabolismo , Membrana Sinovial
10.
BMC Musculoskelet Disord ; 16: 313, 2015 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-26494270

RESUMEN

BACKGROUND: Heterotopic ossification (HO) is a complication after tissue trauma, fracture and surgery (i.e. total hip arthroplasty). Prophylaxis is the most effective therapy. If HO formations become symptomatic and limit patients' quality of life, revision surgery is indicated and is usually combined with a perioperative oral prophylaxis (NSAIDs) and/or irradiation. However, a long-term use of NSAIDs can induce gastro-intestinal or cardiac side-effects and possible bony non-unions during fracture healing. Subject of this study was to assess the current status of HO prophylaxis after injuries or fractures and to evaluate current indications and strategies for excision of symptomatic HO. METHODS: Between 2013 and 2014, a questionnaire was sent to 119 orthopaedic and trauma surgery departments in Germany. Participation was voluntary and all acquired data was given anonymously. RESULTS: The cumulative feedback rate was 71 %. Trauma and orthopaedic surgery departments in Germany recommend oral HO prophylaxis after acetabulum and femoral neck fractures, elbow dislocation, and fracture or dislocation of the radial head. Pain upon movement and an increasing loss of range of motion in the affected joint are considered to be clear indications for HO surgery. A partial removal of ROM-limiting HO formations was also considered important. The vast majority of all departments include perioperative oral HO prophylaxis and/or irradiation if surgical HO removal is planned. The choice and duration of NSAIDs is highly variable. CONCLUSION: HO is of clinical significance in current traumatology and orthopaedics. Certain fractures and injuries are prone to HO, and prophylactic measures should be taken. The respondents in this survey assessed current therapeutic strategies for HO formations similarly. These concepts are in line with the literature. However, the duration of perioperative oral HO prophylaxis varied greatly among the specialist centres. This is significant as a long-term use of NSAIDs fosters a potential risk for the patients' safety and could influence the clinical outcome. National and international guidelines need to be developed to further reduce HO rates and improve patients' safety in trauma and orthopaedic surgery.


Asunto(s)
Osificación Heterotópica/prevención & control , Humanos , Ortopedia/estadística & datos numéricos , Encuestas y Cuestionarios , Centros Traumatológicos/estadística & datos numéricos
11.
Knee Surg Sports Traumatol Arthrosc ; 23(6): 1591-7, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24888221

RESUMEN

PURPOSE: The purpose of this prospective, randomised, double-blind study was to test the hypotheses that patients with high-flexion total knee arthroplasty (TKA) have (1) a wider/greater range of motion (ROM) post-operatively and (2) higher levels of knee society score (KSS) and WOMAC score post-operatively compared to standard TKA. METHODS: In this study, 28 high flexion with 31 standard TKAs were compared. We measured ROM, pre-operatively, on day 3, 7, 28, and after 6 and 36 months post-operatively as well as KSS and WOMAC score pre-operatively, on day 28 and after 6 and 36 months post-operatively. RESULTS: No statistically significant differences were found between both groups with regard to the target parameters. The mean ROM was 113° (range 80°-140°, SD 13.4°) in the control group (standard TKA) and 117° (range 90°-140°, SD 12.3) in the study group (high-flexion TKA) at 36 months follow-up [p = not significant (n.s.)]. The KSS pre-operatively was 38.2 (range 8-64, SD 15.8) in the control group and 45.9 (range 8-74, SD 16.0) in the study group (n.s.) increasing to 157.6 in the control group and 156.7 in the study group (p = n.s) at 36 months follow-up. CONCLUSION: This study could not confirm significant benefits of high-flexion TKA compared to standard TKA with regard to ROM and higher levels of KSS and WOMAC score. LEVEL OF EVIDENCE: I.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla , Evaluación del Resultado de la Atención al Paciente , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/instrumentación , Método Doble Ciego , Femenino , Humanos , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Rango del Movimiento Articular/fisiología
12.
Int Orthop ; 39(3): 455-60, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25242460

RESUMEN

PURPOSE: Restoring a neutral mechanical axis in total knee arthroplasty (TKA) (within ±3° of varus/valgus) is associated with superior functional outcome and reduced early implant failure. Using conventional alignment jigs results in malalignment in >20 % of cases. In this study, we investigated the reduction of outliers within the threshold of ±3° of leg alignment using a "pinless" navigation system in comparison with conventional alignment jigs investigated. METHODS: In this randomised prospective study, 80 patients were randomly assigned/allocated to the pinless or conventional control group. After surgery, the two groups were compared regarding outliers > ±3° by means of hip-knee-ankle angle (HKA), mechanical medial proximal tibia angle (mMPTA), mechanical lateral distal femoral angle (mLDFA) and duration of surgery. Student's unpaired t test was used for quantitative variables, Fisher's exact test compared groups (pinless vs. control) and a two-sided p value of ≤0.05 was considered statistically significant. RESULTS: In the pinless group, outliers regarding HKA and mLDFA > ±3° was significantly reduced (p = 0.025 and p = 0.002 respectively). In the pinless group, the surgery duration was significantly longer (75.6 vs. 64.5 minutes, p < 0.001). CONCLUSION: Pinless navigation is effective in reducing outliers > ±3° regarding HKA without risking pin-related complications, such as fractures, infections or breaking screws. However, not all tools for conventional navigation in TKA, such as real-time measurements of the tibiofemoral axis and gap balancing, are available.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Cirugía Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Femenino , Fémur/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tibia/cirugía
13.
Knee Surg Sports Traumatol Arthrosc ; 22(12): 2982-8, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25253236

RESUMEN

PURPOSE: Rotation of the lower limbs in long-leg radiographs has a significant impact on imaging the mechanical femorotibial angle, the femoral anatomic mechanical angle, the mechanical lateral distal femoral angle (mLDFA) and the mechanical medial proximal tibial angle (mMPTA). In this study, we assessed the rotation of the lower limbs in conventional radiographs and hypothesized that the relative position of the proximal fibula to the proximal tibia on long-leg radiographs is related to the rotation of the knee joint. METHODS: Radiological examinations in different rotational positions of the knee joint (incremental 40° internal to 40° external rotation) were imitated by 50 computed tomography scans (50 patients, 25 men and 25 women). The extent of the projection overlaps of the fibula, the fibular tip and the distance from the fibular tip to the lateral cortex were determined for every rotational position. RESULTS: Multiple regression analysis showed a very strong correlation between the measured fibular parameters and knee rotation between 20° of internal rotation and 40° of external rotation (R (2) ~ 0.94, p < 0.001). By means of these results, we created a formula for predicting knee rotation: [Formula: see text]This strong correlation could not be found between 20° and 40° of internal rotation. DISCUSSION: Because incorrect internal and external rotation negatively influence the correct measurement of angles (mechanical femorotibial angle, femoral anatomic mechanical angle, the mLDFA and the mMPTA), long-leg radiographs should be assessed for proper rotation angles before measurement. Using the provided formula rotation of the lower limb in weight-bearing, long-leg radiographs can be reliably predicted. LEVEL OF EVIDENCE: Diagnostic study, Level II.


Asunto(s)
Peroné/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/diagnóstico por imagen , Tibia/diagnóstico por imagen , Anciano , Femenino , Fémur/diagnóstico por imagen , Humanos , Extremidad Inferior/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Rotación
14.
J Arthroplasty ; 29(8): 1661-5, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24857334

RESUMEN

Successful biomechanical reconstruction is a major goal in total hip arthroplasty (THA). We measured leg length (LL), global (GO) and femoral offset (FO) change on anteroposterior pelvis radiographs and on three-dimensional computed-tomography (3D-CT) with fiducial landmarks after cementless THA on 18 hips of cadaveric specimens. Measurements on radiographs were performed twice by four examiners and showed high interobserver (mean CCC ≥0.79) and intraobserver agreements (mean ICC ≥0.88). Mean differences between radiographic and 3D-CT measurements were 1.0 (SD 2.0) mm for LL, 0.6 (SD 3.6) mm for GO and 1.4 (SD 5.2) mm for FO. 1% of radiographic LL-, 15% of GO- and 35% of FO measurements were outside a tolerance limit of 5mm. Radiographs seem acceptable for measuring LL/GO change but fail to reflect FO change in THA.


Asunto(s)
Artrografía/normas , Artroplastia de Reemplazo de Cadera/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Tomografía Computarizada por Rayos X/normas , Artrografía/métodos , Artrografía/estadística & datos numéricos , Cadáver , Marcadores Fiduciales , Humanos , Imagenología Tridimensional/métodos , Imagenología Tridimensional/normas , Imagenología Tridimensional/estadística & datos numéricos , Variaciones Dependientes del Observador , Pelvis/diagnóstico por imagen , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos
15.
J Arthroplasty ; 29(11): 2197-201, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25108734

RESUMEN

Despite different surgical patellar interventions, the decision how to treat the patella during TKA remains controversial. The purpose of this study was to quantify the effect of different reconstructive patellar interventions on patellar kinematics during TKA using optical computer navigation. We implanted ten navigated TKAs in full body specimens. During passive motion, the effect of different surgical patellar interventions on patellar kinematics was analysed. A contrarily tilt behaviour was observed in the TKA group without patellar intervention compared to the natural knee. Lateral release led to similar tilt values (P < 0.05). All surgical interventions led to a 3 to 5mm medial shift of the patella (P < 0.05). None of the analysed surgical patellar interventions could restore natural patellar kinematics after TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Rótula/cirugía , Anciano , Fenómenos Biomecánicos , Cadáver , Humanos , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Masculino , Rótula/fisiopatología , Rango del Movimiento Articular , Cirugía Asistida por Computador
16.
Int Orthop ; 38(6): 1173-81, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24570152

RESUMEN

PURPOSE: Restoring the joint line (JL) improves clinical and functional outcome in total knee arthroplasty (TKA). Therefore, anatomical landmarks to approximate the JL have been published. So far, the natural deviation of the JL 90° to the mechanical tibial axis has not been considered. Thus, we designed this study to: (1) determine the natural JL of knees in healthy persons in respect to the mechanical tibial axis, (2) validate and double-check intra-operative bony landmarks already been published in respect to the natural JL and (3) find possible correlations between distances from bony landmarks to the JL and femoral and tibial width. METHODS: Eighty MRI scans of knees of healthy persons were examined by two independent observers. Distances from the tip of the fibular head (FH), the medial (ME) and lateral (LE) epicondyles and the adductor tubercle (AT) to the JL within the medial and lateral compartment were measured. Further, we determined the orientation of the JL in respect to the mechanical axis of the tibia. Interobserver correlations were calculated. Differences were analyzed using Student's t test. Linear regression models were calculated to analyze correlations. RESULTS: Interobserver correlation was excellent. Mean JL deviation was 4.2° varus. Distance between the FH, ME, LE and AT to the JL within the medial compartment was 12.2, 33.9, 33.4 and 45.4 mm, respectively. Within in the lateral compartment, distances were 15.3, 31.0, 30.6 and 42.3 mm to the JL. Strong correlation was found between femoral width and distances from the AT, ME and LE to the JL. CONCLUSION: In TKA, the JL is usually altered due to the classic resection technique, which does not respect the natural deviation of the JL. Estimating the natural JL by adding absolute values to bony landmarks, as proposed in the literature, is not recommended. According to our data, the JL can be best estimated by adding the calculated value: 6.40 + (width femur [mm] × 0.49) to the AT.


Asunto(s)
Traumatismos de la Rodilla/diagnóstico , Articulación de la Rodilla , Ligamentos Articulares/lesiones , Imagen por Resonancia Magnética , Lesiones de Menisco Tibial , Adulto , Femenino , Fémur , Humanos , Traumatismos de la Rodilla/cirugía , Ligamentos Articulares/cirugía , Masculino , Meniscos Tibiales/cirugía , Tibia
17.
J Clin Med ; 13(13)2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38999284

RESUMEN

Background: Periprosthetic joint infection (PJI) following total knee arthroplasty is a serious complication lacking evidence-based diagnostic and treatment protocols, particularly in ruling out persisting infection before reimplantation. Methods: This retrospective analysis assessed the mid-term outcomes of 66 patients undergoing septic two-stage knee revision surgeries from 2007 to 2013, diagnosed as per the Musculoskeletal Infection Society criteria. After implant removal and antibiotic treatment, reimplantation decisions were based on either joint aspiration, blood counts, and clinical examination (group A) or an open biopsy (group B). Both groups underwent meticulous debridement and spacer exchange during the interim period. Results: Late re-infection occurred in 12.1% of all patients. In group A, 13.8% experienced late re-infection, with 14.3% in subgroup A1 and 13.3% in subgroup A2. In group B, 10% had a late re-infection. No significant difference in re-infection or complication rates was found between the groups. Conclusions: The study did not demonstrate the superiority of group B's approach of open biopsy over group A's joint aspiration, clinical examination, and blood counts in preventing re-infection or reducing complications.

18.
Open Med (Wars) ; 19(1): 20241028, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39247443

RESUMEN

Background: Chronic lateral ankle instability is a relatively frequent consequence after acute ankle sprain. In case of unsuccessful conservative treatment, surgical therapy is recommended to prevent osteoarthritis of the ankle joint. To date, different surgical methods have evolved. Yet, it remains unclear which approach reveals the best results. We hypothesized that the modified Broström-Gould procedure with suture anchor ligament fixation leads to superior postoperative results compared to the Broström-Gould procedure or the periosteal flap technique. Material and methods: In a prospective study, we examined the three surgical techniques. For this purpose, we performed a matched-pair analysis with four groups according to age, sex, and body mass index: periosteal flap technique (G1), Broström-Gould procedure (G2), modified Broström-Gould procedure with suture anchor ligament fixation (G3), and a control group (G4). Results were compared with the American Orthopaedic Foot & Ankle Society (AOFAS) score, a functional analysis as well as measuring postural stability with the Biodex balance system. Results: No significant differences were found between all four groups concerning AOFAS score, functional results, as well as postural stability. Conclusion: All three surgical methods revealed satisfactory results. No significant differences could be detected in clinical and functional categories. The Broström-Gould method as well as the modified procedure with anchor can be recommended as surgical therapy for chronic lateral ankle instability. Additional anchors do not seem to have a significant positive impact on the results.

19.
J Orthop Sci ; 18(6): 955-61, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24077758

RESUMEN

BACKGROUND: Revision total knee arthroplasties (TKA) have been performed with increasing frequency over the last 25 years. METHODS: In this study, we retrospectively analyzed 78 patients who underwent 78 revision TKAs during the years 2003­2007 with an average follow-up of 81 months (range 60­108 months). All patients were treated with a standard rotating hinge prosthesis (TC3, DePuy, Warsaw, IN, USA) due to significant instability. We evaluated the postoperative results using the Knee Society clinical rating system and the WOMAC rating system. RESULTS: Clinical results revealed significant improvements in both scores. Complications occurred in almost one-third of the cases, with a reoperation rate of 26 %. CONCLUSION: Our mid-term findings show that revision TKAs lead to an improvement in patient-perceived outcomes of physical variables. While revision TKA is a useful option for patients, procedure-associated complications should not be neglected. During the course of the procedure, it is important to collect patient-oriented data and focus on responsive and valid scores.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Osteoartritis de la Rodilla/cirugía , Dolor Postoperatorio/fisiopatología , Falla de Prótesis , Autoevaluación (Psicología) , Factores de Edad , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/métodos , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Alemania , Humanos , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico , Dimensión del Dolor , Satisfacción del Paciente/estadística & datos numéricos , Rango del Movimiento Articular/fisiología , Reoperación/métodos , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
20.
Int Orthop ; 37(3): 407-14, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23361937

RESUMEN

PURPOSE: Individual physiological knee kinematics are highly variable in normal knees and are altered following cruciate-substituting (PS) and cruciate-retaining (CR) total knee arthroplasty (TKA). We wanted to know whether knee kinematics are different choosing two different knee designs, CR and PS TKA, during surgery using computer navigation. METHODS: For this purpose, 60 consecutive TKA were randomised, receiving either CR (37 patients) or PS TKA (23 patients). All patients underwent computer navigation, and kinematics were assessed prior to making any cuts or releases and after implantation. Outcome measures were relative rotation between femur and tibia, measured medial and lateral gaps and medial and lateral condylar lift-off. RESULTS: We were not able to demonstrate a significant difference in femoral external rotation between either group prior to implantation (7.9° CR vs. 7.4° PS) or after implantation (9.0° CR vs. 11.3° PS), both groups showed femoral roll-back. It significantly increased pre- to postoperatively in PS TKA. In the CR group both gaps increased, the change of the medial gap was significantly attributable to medial release. In the PS group both gaps increased and the change of the medial and of the lateral gap was significant. Condylar lift-off was observed in the CR group during 20° and 60° of flexion. CONCLUSION: This study did not reveal significant differences in navigation-based knee kinematics between CR and PS implants. Femoral roll-back was observed in both implant designs, but significantly increased pre- to postoperatively in PS TKA. A slight midflexion instability was observed in CR TKA. Intra-operative computer navigation can measure knee kinematics during surgery before and after TKR implantation and may assist surgeons to optimise knee kinematics or identify abnormal knee kinematics that could be corrected with ligament releases to improve the functional result of a TKR, whether it is a CR or PS design. Our intra-operative finding needs to be confirmed using fluoroscopic or radiographic 3D matching after complete recovery from surgery.


Asunto(s)
Articulación de la Rodilla/fisiopatología , Osteoartritis de la Rodilla/cirugía , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla , Fenómenos Biomecánicos , Femenino , Fémur/cirugía , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/fisiopatología , Estudios Prospectivos , Rotación , Técnicas Estereotáxicas , Cirugía Asistida por Computador , Tibia/cirugía