Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38885309

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD), that led to an advisory for nearly 40 000 patients. This multicentre study evaluated the incidence of PBD in a large set of S-ICD patients. METHODS AND RESULTS: Data from patients implanted with S-ICD models A209 and A219 between October 2012 and July 2023 across nine centres in Europe and the USA were reviewed. Incidence and implications of PBD, defined as clinically observed sudden drop in battery longevity, were analysed and compared to PBD with the definition of battery depletion within 60 months. Prospectively collected clinical data were obtained retrospectively from medical records, device telemetry, and manufacturer reports. This registry is listed on ClinicalTrials.gov (NCT05713708). Of the 1112 S-ICD devices analysed, 547 (49.2%) were equipped with a potentially affected capacitor linked to PBD occurrence, currently under Food and Drug Administration advisory. The median follow-up time for all patients was 46 [inter-quartile range (IQR) 24-63] months. Clinically suspected PBD was observed in 159 (29.1%) of cases, with a median time to generator removal or replacement of 65 (IQR 55-72) months, indicative of significant deviations from expected battery lifespan. Manufacturer confirmation of PBD was made in 91.7% of devices returned for analysis. No cases of PBD were observed in devices that were not under advisory. CONCLUSION: This manufacturer-independent analysis highlights a notable incidence of PBD in patients equipped with S-ICD models under advisory, and the rate of PBD in this study corresponds to the rate currently estimated by the manufacturer. To the best of our knowledge, this provides the largest contemporary peer-reviewed study cohort investigating the actual incidence of PBD in S-ICD patients. These findings emphasize the importance of post-market registries in collaboration between clinicians and the manufacturer to optimize safety and efficacy in S-ICD treatment.


Asunto(s)
Desfibriladores Implantables , Suministros de Energía Eléctrica , Sistema de Registros , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Estados Unidos/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Europa (Continente)/epidemiología , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Falla de Equipo/estadística & datos numéricos , Factores de Tiempo , Análisis de Falla de Equipo/estadística & datos numéricos , Adulto
2.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38861398

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as 'sense-B-noise.' It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. METHODS AND RESULTS: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23-64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2-70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. CONCLUSION: This multicentre analysis' findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica , Sistema de Registros , Humanos , Masculino , Estudios Retrospectivos , Femenino , Persona de Mediana Edad , Incidencia , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Anciano , Europa (Continente)/epidemiología , Falla de Equipo/estadística & datos numéricos , Estados Unidos/epidemiología , Factores de Riesgo
3.
JAMA ; 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39221629

RESUMEN

Importance: There are concerns that pulmonary vein isolation for atrial fibrillation may have a profound placebo effect, but no double-blind randomized clinical trials have been conducted. Objective: To determine whether pulmonary vein isolation is more effective than a sham procedure for improving outcomes in atrial fibrillation. Design, Setting, and Participants: Double-blind randomized clinical trial conducted at 2 tertiary centers in the UK between January 2020 and March 2024 among patients with symptomatic paroxysmal or persistent atrial fibrillation. Major exclusion criteria included long-standing persistent atrial fibrillation, prior left atrium ablation, other arrhythmias requiring ablative therapy, a left atrium of 5.5 cm or larger, and ejection fraction of less than 35%. Intervention: Participants were randomly assigned to receive pulmonary vein isolation with cryoablation (n = 64) or a sham procedure with phrenic nerve pacing (n = 62). Main Outcomes and Measures: The primary end point was atrial fibrillation burden at 6 months, excluding a 3-month blanking period. Secondary outcomes included quality-of-life measures, time to events, and safety. Atrial fibrillation burden was measured by an implantable loop recorder. Results: A total of 126 participants were randomized (mean age, 66.8 years; 89 men [70.63%]; 20.63% with paroxysmal atrial fibrillation). The absolute mean atrial fibrillation burden change from baseline to 6 months was 60.31% in the ablation group and 35.0% in the sham group (geometric mean difference, 0.25; 95% CI, 0.15-0.42; P < .001). The estimated difference in the overall Atrial Fibrillation Effect on Quality of Life score at 6 months, favoring catheter ablation, was 18.39 points (95% CI, 11.48-25.30 points). The Short Form 36 general health score also improved substantially more with ablation, with an estimated difference of 9.27 points at 6 months (95% CI, 3.78-14.76 points). Conclusions and Relevance: Pulmonary vein isolation resulted in a statistically significant and clinically important decrease in atrial fibrillation burden at 6 months, with substantial improvements in symptoms and quality of life, compared with a sham procedure. Trial Registration: ClinicalTrials.gov Identifier: NCT04272762.

4.
Indian Pacing Electrophysiol J ; 24(2): 94-104, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38159808

RESUMEN

We present the case of a 16-year-old male pediatric patient diagnosed with hypertrophic cardiomyopathy (HCM, identified as having a high risk of sudden cardiac death (SCD), who underwent a successful subcutaneous implantable cardiac defibrillator (S-ICD) implantation as a primary prevention measure in 2018. His past medical history included ADHD, Autism, and panic attacks. The patient experienced appropriate shocks that successfully terminated VF episodes. However, he also experienced multiple inappropriate shocks from the S-ICD, triggered by anxiety-induced tachycardia during panic episodes. Meticulous assessment of S-ICD tracings and electrocardiograms (ECGs) revealed the erroneous classification of sinus tachycardia as sustained ventricular tachycardia, leading to unwarranted therapeutic interventions. Clinical intervention involved reprogramming of the S-ICD, emphasizing the pivotal role of personalized device configuration in pediatric cases where fine margins matter. While literature on S-ICD use in pediatric populations remains limited, emerging registries underscore the efficacy and safety of S-ICDs in preventing sudden cardiac death while reducing complications associated with intravascular leads. This case underscores the critical nature of customized device programming in pediatric patients, underscoring S-ICDs as a practical defibrillation alternative that addresses distinct concerns within this cohort of patients.

5.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37738643

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI. METHODS AND RESULTS: Multi-centre study across 12 centres. Procedural metrics, safety profile, and procedural efficacy of the PolarX Cryoballoon with the Arctic Front Advance (AFA) Cryoballoon were compared in a cohort large enough to provide definitive comparative data. A total of 1688 patients underwent PVI with cryoablation (50% PolarX and 50% AFA). Successful PVI was achieved with 1677 (99.3%) patients with 97.2% (n = 1641) performed as day case procedures with a complication rate of <1%. Safety, procedural metrics, and efficacy of the PolarX Cryoballoon were comparable with the AFA cohort. The PolarX Cryoballoon demonstrated a nadir temperature of -54.6 ± 7.6°C, temperature at 30 s of -38.6 ± 7.2°C, time to -40°C of 34.1 ± 13.7 s, and time to isolation of 49.8 ± 33.2 s. Independent predictors for achieving PVI included time to reach -40°C [odds ratio (OR) 1.34; P < 0.001] and nadir temperature (OR 1.24; P < 0.001) with an optimal cut-off of ≤34 s [area under the curve (AUC) 0.73; P < 0.001] and nadir temperature of ≤-54.0°C (AUC 0.71; P < 0.001), respectively. CONCLUSIONS: This large-scale UK multi-centre study has shown that Cryoballoon PVI is a safe, effective day case procedure. PVI using the PolarX Cryoballoon was similarly safe and effective as the AFA Cryoballoon. The cryoablation metrics achieved with the PolarX Cryoballoon were different to that reported with the AFA Cryoballoon. Modified cryoablation targets are required when utilizing the PolarX Cryoballoon.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento , Factores de Tiempo , Venas Pulmonares/cirugía , Ablación por Catéter/métodos , Reino Unido , Recurrencia
6.
Europace ; 24(9): 1420-1429, 2022 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-35737685

RESUMEN

AIM: Evaluate the novel PolarX Cryoballoon in atrial fibrillation (AF) catheter ablation through a propensity-matched comparison with the Arctic Front Advance (AFA). The aim was also to identify cryoablation metrics that are predictive of successful pulmonary vein isolation (PVI) with the PolarX Cryoballoon. METHODS AND RESULTS: This prospective multi-centre study included patients that underwent cryoablation for AF. All patients underwent PVI with reconnection assessed after a 30-min waiting period and adenosine. Safety, efficacy, and cryoablation metrics were compared between PolarX and a propensity-matched AFA cohort. Seventy patients were included with 278 veins treated. In total, 359 cryoablations were performed (1.3 ± 0.6 per vein) to achieve initial PVI with 205 (73.7%) veins isolating with a single cryoablation. Independent predictors for achieving initial PVI included temperature at 30 s [odds ratio (OR) 1.26; P = 0.003] and time to reach -40°C (OR 1.88; P < 0.001) with an optimal cut-off of ≤-38.5°C at 30 s [area under the curve (AUC) 0.79; P < 0.001] and ≤-40°C at ≤32.5 s (AUC 0.77; P < 0.001), respectively. Of the 278 veins, 46 (16.5%) veins showed acute reconnection. Temperature at 30 s (≤-39.5°C, OR 1.24; P = 0.002), nadir temperature (≤-53.5°C, OR 1.35; P = 0.003), and time to isolation (≤38.0 s, OR 1.18; P = 0.009) were independent predictors of sustained PVI. Combining two of these three targets was associated with reconnection in only 2-5% of PVs. Efficacy and safety of the PolarX Cryoballoon were comparable to AFA Cryoballoon, however, cryoablation metrics were significantly different. CONCLUSIONS: The PolarX Cryoballoon has a different cryoablation profile to AFA Cryoballoon. Prospective testing of these proposed targets in large outcomes studies is required.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Adenosina , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Benchmarking , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
7.
Rev Cardiovasc Med ; 22(2): 415-428, 2021 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-34258908

RESUMEN

Heart failure (HF) is a complex clinical syndrome characterised by significant morbidity and mortality worldwide. Evidence-based therapies for the management of HF include several well-established neurohormonal antagonists and antiarrhythmic drug therapy to mitigate the onset of cardiac arrhythmia. However, the degree of rate and rhythm control achieved is often suboptimal and mortality rates continue to remain high. Implantable cardioverter-defibrillators (ICDs), cardiac resynchronization (CRT), and combined (CRT-D) therapies have emerged as integral and rapidly expanding technologies in the management of select patients with heart failure with reduced ejection fraction (HFrEF). ICDs treat ventricular arrhythmia and are used as primary prophylaxis for sudden cardiac death, while CRT resynchronizes ventricular contraction to improve left ventricular systolic function. Left ventricular assist device therapy has also been shown to provide clinically meaningful survival benefits in patients with advanced HF, and His-bundle pacing has more recently emerged as a safe, viable, and promising pacing modality for patients with CRT indication. Catheter ablation is another important and well-established strategy for managing cardiac arrhythmia in HF, demonstrating superior efficacy when compared with antiarrhythmic drug therapy alone. In this article, we provide a comprehensive and in-depth evaluation of the role of implantable devices and catheter ablation in patients with HFrEF, outlining current applications, recent advances, and future directions in practice.


Asunto(s)
Terapia de Resincronización Cardíaca , Ablación por Catéter , Desfibriladores Implantables , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/efectos adversos , Ablación por Catéter/efectos adversos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Volumen Sistólico , Resultado del Tratamiento
8.
Pacing Clin Electrophysiol ; 44(4): 723-725, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33140464

RESUMEN

A 52-year-old gentleman with a subcutaneous implantable cardioverter defibrillator (S-ICD) implanted in 2015 for primary prevention and a background of hypertrophic cardiomyopathy presented via remote monitoring alert (Boston Scientific Latitude NXT) with an aborted charge episode. The episode showed myopotential noise with baseline wander, and an urgent outpatient follow-up was arranged. Upon investigation the S-ICD lead had retracted to the pocket of the generator via a reel mechanism, wrapping the lead around the can. This was likely to be caused by insufficient suturing of the lead collar at the base of xiphisternum. The device had automatically disabled the SmartPass filter, which does not currently have an alert mechanism. This case highlights the rare occurrence of S-ICD lead displacement and components of the SmartPass system which can provide an early warning to lead problems.


Asunto(s)
Cardiomiopatía Hipertrófica/terapia , Desfibriladores Implantables/efectos adversos , Electrodos Implantados/efectos adversos , Falla de Prótesis , Humanos , Masculino , Persona de Mediana Edad , Prevención Primaria
9.
J Cardiovasc Electrophysiol ; 30(12): 2900-2906, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31578806

RESUMEN

INTRODUCTION: Implantable loop recorders (ILR) are predominantly implanted by cardiologists in the catheter laboratory. We developed a nurse-delivered service for the implantation of LINQ (Medtronic; Minnesota) ILRs in the outpatient setting. This study compared the safety and cost-effectiveness of the introduction of this nurse-delivered ILR service with contemporaneous physician-led procedures. METHODS: Consecutive patients undergoing an ILR at our institution between 1st July 2016 and 4th June 2018 were included. Data were prospectively entered into a computerized database, which was retrospectively analyzed. RESULTS: A total of 475 patients underwent ILR implantation, 271 (57%) of these were implanted by physicians in the catheter laboratory and 204 (43%) by nurses in the outpatient setting. Six complications occurred in physician-implants and two in nurse-implants (P = .3). Procedural time for physician-implants (13.4 ± 8.0 minutes) and nurse-implants (14.2 ± 10.1 minutes) were comparable (P = .98). The procedural cost was estimated as £576.02 for physician-implants against £279.95 with nurse-implants, equating to a 57.3% cost reduction. In our center, the total cost of ILR implantation in the catheter laboratory by physicians was £10 513.13 p.a. vs £6661.55 p.a. with a nurse-delivered model. When overheads for running, cleaning, and maintaining were accounted for, we estimated a saving of £68 685.75 was performed by moving to a nurse-delivered model for ILR implants. Over 133 catheter laboratory and implanting physician hours were saved and utilized for other more complex procedures. CONCLUSION: ILR implantation in the outpatient setting by suitably trained nurses is safe and leads to significant financial savings.


Asunto(s)
Atención Ambulatoria/economía , Costos de la Atención en Salud , Monitoreo Ambulatorio/economía , Monitoreo Ambulatorio/enfermería , Rol de la Enfermera , Rol del Médico , Tecnología de Sensores Remotos/economía , Tecnología de Sensores Remotos/enfermería , Adulto , Anciano , Competencia Clínica/economía , Ahorro de Costo , Análisis Costo-Beneficio , Bases de Datos Factuales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio/instrumentación , Valor Predictivo de las Pruebas , Tecnología de Sensores Remotos/instrumentación , Estudios Retrospectivos , Flujo de Trabajo
10.
J Cardiovasc Electrophysiol ; 30(3): 357-365, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30556609

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) using high power delivered by SmartTouch Surround Flow (STSF) catheters guided by ablation index (AI) was evaluated in a multicenter registry. METHODS: Patients with paroxysmal AF underwent PVI with STSF catheters using 30 W on the posterior wall and 40 W elsewhere. AI targets were 350 posterior walls and 450 elsewhere. Procedures were compared with controls using conventionally irrigated contact force-sensing catheters using conventional powers (25 W posterior wall and 30 W elsewhere) guided by force-time integral (no agreed targets). The waiting period of 30 minutes was observed before adenosine administration to assess acute pulmonary vein (PV) reconnection. RESULTS: One hundred patients from four centers were included: 50 patients in the high power ablation index (HPAI) group and 50 controls. Procedure time was 22% shorter in the HPAI group (156 [133.8-179] vs 199 [178.5-227] minutes; P < 0.001). Duration of the radiofrequency application was 37% shorter in the HPAI group (27.2 [21.5-35.8] vs 43.2 [35.1-52.1] minutes; P < 0.001). Acute PV reconnection was reduced (28 of 200 [14%] vs 48 of 200 [24%] veins; P = 0.015). Reconnection was predicted by a largest interlesion distance greater than 6 mm, a lesion with impedance drop less than 2.5 Ω, contact force less than 6 g, or less than 68% of the regional AI target (all P < 0.001). Freedom from atrial arrhythmia at 1 year off antiarrhythmic drugs after a single procedure was 78% in the HPAI group vs 64% in the control group ( P = 0.186). CONCLUSION: High-powered ablation guided by AI was safe and led to shorter procedure times with reduced acute PV reconnection compared with conventional ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Potenciales de Acción , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Estudios de Casos y Controles , Ablación por Catéter/efectos adversos , Inglaterra , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Tempo Operativo , Venas Pulmonares/fisiopatología , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
11.
Europace ; 21(4): 616-625, 2019 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-30500897

RESUMEN

AIMS: Differences of action potential duration (APD) in regions of myocardial scar and their borderzones are poorly defined in the intact human heart. Heterogeneities in APD may play an important role in the generation of ventricular tachycardia (VT) by creating regions of functional block. We aimed to investigate the transmural and planar differences of APD in patients admitted for VT ablation. METHODS AND RESULTS: Six patients (median age 53 years, five male); (median ejection fraction 35%), were studied. Endocardial (Endo) and epicardial (Epi) 3D electroanatomic mapping was performed. A bipolar voltage of <0.5 mV was defined as dense scar, 0.5-1.5 mV as scar borderzone, and >1.5 mV as normal. Decapolar catheters were positioned transmurally across the scar borderzone to assess differences of APD and repolarization time (RT) during restitution pacing from Endo and Epi. Epi APD was 173 ms in normal tissue vs. 187 ms at scar borderzone and 210 ms in dense scar (P < 0.001). Endocardial APD was 210 ms in normal tissue vs. 222 ms in the scar borderzone and 238 ms in dense scar (P < 0.01). This resulted in significant transmural RT dispersion (ΔRT 22 ms across dense transmural scar vs. 5 ms in normal transmural tissue, P < 0.001), dependent on the scar characteristics in the Endo and Epi, and the pacing site. CONCLUSION: Areas of myocardial scar have prolonged APD compared with normal tissue. Heterogeneity of regional transmural and planar APD result in localized dispersion of repolarization, which may play an important role in initiating VT.


Asunto(s)
Potenciales de Acción , Ablación por Catéter , Cicatriz/fisiopatología , Endocardio/fisiopatología , Pericardio/fisiopatología , Taquicardia Ventricular/cirugía , Adulto , Anciano , Displasia Ventricular Derecha Arritmogénica/complicaciones , Cardiomiopatías/complicaciones , Cicatriz/etiología , Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas , Mapeo Epicárdico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/complicaciones , Miocarditis/complicaciones , Miocardio , Recurrencia , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Factores de Tiempo
12.
Europace ; 20(4): 682-691, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-28444174

RESUMEN

Aims: Cardiac sarcoidosis (CS) is associated with a poor prognosis. Important features of CS include heart failure, conduction abnormalities, and ventricular arrhythmias. Ventricular tachycardia (VT) is often refractory to antiarrhythmic drugs (AAD) and immunosuppression. Catheter ablation has emerged as a treatment option for recurrent VT. However, data on the efficacy and outcomes of VT ablation in this context are sparse. Methods and results: A systematic search was performed on PubMed, EMBASE, and Cochrane database (from inception to September 2016) with included studies providing a minimum of information on CS patients undergoing VT ablation: age, gender, VT cycle length, CS diagnosis criteria, and baseline medications. Five studies reporting on 83 patients were identified. The mean age of patients was 50 ± 8 years, 53/30 (males/females) with a maximum of 56 patients receiving immunosuppressive therapy, mean ejection fraction was 39.1 ± 3.1% and 94% had an implantable cardioverter defibrillator in situ. The median number of VTs was 3 (2.6-4.9)/patient, mean cycle length of 360 ms (326-400 ms). Hundred percent of VTs received endocardial ablation, and 18% required epicardial ablation. The complication rates were 4.7-6.3%. Relapse occurred in 45 (54.2%) patients with an incidence of relapse 0.33 (95% confidence interval 0.108-0.551, P < 0.004). Employing a less stringent endpoint (i.e. freedom from arrhythmia or reduction of ventricular arrhythmia burden), 61 (88.4%) patients improved following ablation. Conclusions: These data support the utilization of catheter ablation in selected CS cases resistant to medical treatment. However, data are derived from observational non-controlled case series, with low-methodological quality. Therefore, future well-designed, randomized controlled trials, or large-scale registries are required.


Asunto(s)
Cardiomiopatías/complicaciones , Ablación por Catéter , Sarcoidosis/complicaciones , Taquicardia Ventricular/cirugía , Potenciales de Acción , Adulto , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Recurrencia , Factores de Riesgo , Sarcoidosis/diagnóstico , Sarcoidosis/fisiopatología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento
13.
Pacing Clin Electrophysiol ; 41(4): 353-361, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29344950

RESUMEN

INTRODUCTION: Cardiac resynchronization using a left ventricular (LV) epicardial lead placed in the coronary sinus is now routinely used in the management of heart failure patients. LV endocardial pacing is an alternative when this is not feasible, with outcomes data sparse. OBJECTIVE: To review the available evidence on the efficacy and safety of endocardial LV pacing via meta-analysis. METHODS: EMBASE, MEDLINE, and COCHRANE databases with the search term "endocardial biventricular pacing" or "endocardial cardiac resynchronization" or "left ventricular endocardial" or "endocardial left ventricular." Comparisons of pre-and post-QRS width, LV ejection fraction (LVEF), and New York Heart Association (NYHA) functional classification was performed, and mean differences (and respective 95% confidence interval [CI]) applied as a measurement of treatment effect. RESULTS: Fifteen studies, including 362 patients, were selected. During a mean follow-up of 40 ± 24.5 months, death occurred in 72 patients (11 per 100 patient-years). Significant improvements in LVEF (mean difference 7.9%, 95% CI 5-10%, P < 0.0001; I2  = 73%), QRS width (mean difference: -41% 95% -75 to -7%; P < 0.0001; I2  = 94%), and NYHA class (mean difference: -1.06, 95% CI -1.2 to -0.9, P < 0.0001; I2  = 60%), (all P < 0.0001) occurred. Stroke rate was 3.3-4.2 per 100 patient-years, which is higher than equivalent heart failure trial populations and recent meta-analysis that included small case series. CONCLUSION: LV endocardial lead implantation is a potentially efficacious alternative to CS lead placement, but preliminary data suggest a potentially higher risk of stroke during follow-up when compared to the expected incidence of stroke in similar cohorts of patients.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Endocardio/fisiopatología , Insuficiencia Cardíaca/prevención & control , Insuficiencia Cardíaca/fisiopatología , Terapia de Resincronización Cardíaca/métodos , Humanos
14.
Europace ; 19(11): 1874-1880, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-27738067

RESUMEN

AIMS: Early repolarization (ER) has been linked to poorer outcomes in idiopathic ventricular fibrillation (IVF). The role of family screening in IVF is not clear. Our aim was to review predictors for poorer outcomes and evaluate the role of family screening in IVF. METHODS AND RESULTS: This was a retrospective multicentre cohort study including all patients diagnosed with IVF. Data were collected on baseline characteristics, ECG findings, and recurrence of ventricular arrhythmia (VA) during follow-up. Electrocardiogram findings were reviewed in first-degree relatives that were screened. A total of 66 patients were included with male predominance (42/66, 64%) and Caucasian ethnicity (47/66, 71%). Mean age at cardiac arrest was 38 years ± 11. Thirty-one patients had ER (47%) predominantly with J-point amplitude ≥2 mm and horizontal ST segments (18/31, 58%). Recurrent VA was seen in 13 patients (20%). Horizontal ST segments were associated with increased rates of VA recurrence (OR 11, 95% CI 2.7-43.7; P = 0.0007). Early repolarization was seen in 20% of the 72 first-degree relatives and was more common if the proband had persistent ER pattern (OR 10.7, 95% CI 2.2-51.5; P = 0.003). CONCLUSION: Ventricular arrhythmia recurrence was lower than previously reported. Early repolarization was common in this IVF cohort, and horizontal ST segments were suggestive predictor for poorer outcomes. Persistent ER in proband was associated with ER in first-degree relatives. With better understanding of its predictive value and the relationship to IVF, this information could potentially be used to guide family screening and identify new mutations using family members with persistent ER.


Asunto(s)
Pruebas Genéticas/métodos , Mutación , Fibrilación Ventricular/diagnóstico , Adulto , Toma de Decisiones Clínicas , Muerte Súbita Cardíaca/etiología , Electrocardiografía , Femenino , Predisposición Genética a la Enfermedad , Paro Cardíaco/genética , Paro Cardíaco/mortalidad , Herencia , Humanos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Linaje , Fenotipo , Valor Predictivo de las Pruebas , Pronóstico , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Fibrilación Ventricular/genética , Fibrilación Ventricular/mortalidad , Fibrilación Ventricular/fisiopatología
15.
Europace ; 19(1): 48-57, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27267554

RESUMEN

AIM: Cryoballoon ablation (Cryoballoon) has emerged as a new alternative for the treatment of symptomatic drug-refractory atrial fibrillation (AF). Whether the results of Cryoballoon are more reproducible than those of radiofrequency (RF) ablation remains to be proved. METHODS AND RESULTS: A total of 860 consecutive patients undergoing a first ablation procedure for paroxysmal AF (467 treated with RF and 393 treated with Cryoballoon) were selected from a prospective multicentre survey of AF ablation (FrenchAF). Radiofrequency and Cryoballoon were compared regarding mid-term efficacy and safety. During a median follow-up of 14 months (interquartile range 8-23), patients treated with Cryoballoon displayed similar rates of freedom from atrial arrhythmia relapse in centres performing this technique (68-80% at 18 months). However, in centres performing RF, a greater heterogeneity in procedural results was observed (46-79% were free from atrial arrhythmia relapse at 18 months). On multivariate analysis, Cryoballoon (HR = 0.47, 95% CI 0.35-0.65, P < 0.001) and annual AF ablation caseload (HR = 0.87 per every 100 AF ablation procedures per year; 95% CI 0.80-0.96, P = 0.003) were independent predictors of procedural success. However, on sensitivity analysis, according to the ablation method, annual AF ablation caseload predicted only sinus rhythm maintenance in the subgroup of patients treated with RF. Analysis of interoperator results with Cryoballoon and RF confirmed lower reproducibility of RF, but suggested that besides caseload, other operator-related factors may play a role. CONCLUSION: Cryoballoon seems to be less operator-dependent and more reproducible than RF in the setting of paroxysmal AF ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Distribución de Chi-Cuadrado , Competencia Clínica , Criocirugía/efectos adversos , Criocirugía/instrumentación , Supervivencia sin Enfermedad , Diseño de Equipo , Femenino , Francia , Encuestas de Atención de la Salud , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Recurrencia , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Carga de Trabajo
16.
Am J Physiol Heart Circ Physiol ; 311(3): H545-54, 2016 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-27371682

RESUMEN

The spatial variation in restitution properties in relation to varying stimulus site is poorly defined. This study aimed to investigate the effect of varying stimulus site on apicobasal and transmural activation time (AT), action potential duration (APD) and repolarization time (RT) during restitution studies in the intact human heart. Ten patients with structurally normal hearts, undergoing clinical electrophysiology studies, were enrolled. Decapolar catheters were placed apex to base in the endocardial right ventricle (RVendo) and left ventricle (LVendo), and an LV branch of the coronary sinus (LVepi) for transmural recording. S1-S2 restitution protocols were performed pacing RVendo apex, LVendo base, and LVepi base. Overall, 725 restitution curves were analyzed, 74% of slopes had a maximum slope of activation recovery interval (ARI) restitution (Smax) > 1 (P < 0.001); mean Smax = 1.76. APD was shorter in the LVepi compared with LVendo, regardless of pacing site (30-ms difference during RVendo pacing, 25-ms during LVendo, and 48-ms during LVepi; 50th quantile, P < 0.01). Basal LVepi pacing resulted in a significant transmural gradient of RT (77 ms, 50th quantile: P < 0.01), due to loss of negative transmural AT-APD coupling (mean slope 0.63 ± 0.3). No significant transmural gradient in RT was demonstrated during endocardial RV or LV pacing, with preserved negative transmural AT-APD coupling (mean slope -1.36 ± 1.9 and -0.71 ± 0.4, respectively). Steep ARI restitution slopes predominate in the normal ventricle and dynamic ARI; RT gradients exist that are modulated by the site of activation. Epicardial stimulation to initiate ventricular activation promotes significant transmural gradients of repolarization that could be proarrhythmic.


Asunto(s)
Potenciales de Acción/fisiología , Endocardio/fisiología , Sistema de Conducción Cardíaco/fisiología , Ventrículos Cardíacos , Corazón/fisiología , Función Ventricular , Adulto , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miocardio
18.
Curr Cardiol Rep ; 16(8): 516, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24994568

RESUMEN

The Subcutaneous Internal Cardiac Defibrillator (S-ICD) represents a major advance in the care of patients who have an indication for an internal cardiac defibrillator without pacing indications. Its main advantage is that it can deliver a shock to cardiovert ventricular arrhythmias utilising a tunnelled subcutaneous lead, negating the risks associated with conventional transvenous systems. Initial studies have shown comparable efficacy in cardioversion of induced and spontaneous ventricular tachycardia (VT) and ventricular fibrillation (VF) when compared to conventional transvenous systems. In addition, inappropriate shocks occurred in a similar percentage of patients to conventional ICD studies. Complication rates are low and relate largely to localised wound infections, treated successfully with antibiotics. The long term efficacy of the device is yet to be ascertained, however, a randomised trial & prospective registries are currently in progress to enable direct comparison with transvenous ICDs. This article summarises the early clinical experience and trials in the implantation of the S-ICD.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/métodos , Traumatismos por Electricidad/etiología , Humanos , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia
19.
J Cardiovasc Dev Dis ; 11(4)2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38667715

RESUMEN

The management of atrial fibrillation has evolved significantly over the last ten years with advancements in medical and catheter ablation approaches, but these have limited success when used in isolation. Trends in the management of lifestyle modifications have surfaced, as it is now better understood that modifiable risk factors contribute significantly to the development and propagation of atrial fibrillation, as well as failure of treatment. International guidelines have integrated the role of lifestyle modification in the management of atrial fibrillation and specifically in the persistent form of atrial fibrillation; these guidelines must be addressed prior to considering catheter ablation. Effective risk factor modification is critical in increasing the likelihood of an arrhythmia-free survival following catheter ablation.

20.
Sci Rep ; 14(1): 8371, 2024 04 10.
Artículo en Inglés | MEDLINE | ID: mdl-38600217

RESUMEN

Cardiac resynchronisation therapy (CRT) improves prognosis in patients with heart failure (HF) however the role of ABO blood groups and Rhesus factor are poorly understood. We hypothesise that blood groups may influence clinical and survival outcomes in HF patients undergoing CRT. A total of 499 patients with HF who fulfilled the criteria for CRT implantation were included. Primary outcome of all-cause mortality and/or heart transplant/left ventricular assist device was assessed over a median follow-up of 4.6 years (IQR 2.3-7.5). Online repositories were searched to provide biological context to the identified associations. Patients were divided into blood (O, A, B, and AB) and Rhesus factor (Rh-positive and Rh-negative) groups. Mean patient age was 66.4 ± 12.8 years with a left ventricular ejection fraction of 29 ± 11%. There were no baseline differences in age, gender, and cardioprotective medication. In a Cox proportional hazard multivariate model, only Rh-negative blood group was associated with a significant survival benefit (HR 0.68 [0.47-0.98], p = 0.040). No association was observed for the ABO blood group (HR 0.97 [0.76-1.23], p = 0.778). No significant interaction was observed with prevention, disease aetiology, and presence of defibrillator. Rhesus-related genes were associated with erythrocyte and platelet function, and cholesterol and glycated haemoglobin levels. Four drugs under development targeting RHD were identified (Rozrolimupab, Roledumab, Atorolimumab, and Morolimumab). Rhesus blood type was associated with better survival in HF patients with CRT. Further research into Rhesus-associated pathways and related drugs, namely whether there is a cardiac signal, is required.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Persona de Mediana Edad , Anciano , Volumen Sistólico , Función Ventricular Izquierda , Terapia de Resincronización Cardíaca/efectos adversos , Sistema del Grupo Sanguíneo ABO , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA