Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Alzheimers Dement ; 17(4): 716-725, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33480157

RESUMEN

The MarkVCID consortium was formed under cooperative agreements with the National Institute of Neurologic Diseases and Stroke (NINDS) and National Institute on Aging (NIA) in 2016 with the goals of developing and validating biomarkers for the cerebral small vessel diseases associated with the vascular contributions to cognitive impairment and dementia (VCID). Rigorously validated biomarkers have consistently been identified as crucial for multicenter studies to identify effective strategies to prevent and treat VCID, specifically to detect increased VCID risk, diagnose the presence of small vessel disease and its subtypes, assess prognosis for disease progression or response to treatment, demonstrate target engagement or mechanism of action for candidate interventions, and monitor disease progression during treatment. The seven project sites and central coordinating center comprising MarkVCID, working with NINDS and NIA, identified a panel of 11 candidate fluid- and neuroimaging-based biomarker kits and established harmonized multicenter study protocols (see companion paper "MarkVCID cerebral small vessel consortium: I. Enrollment, clinical, fluid protocols" for full details). Here we describe the MarkVCID neuroimaging protocols with specific focus on validating their application to future multicenter trials. MarkVCID procedures for participant enrollment; clinical and cognitive evaluation; and collection, handling, and instrumental validation of fluid samples are described in detail in a companion paper. Magnetic resonance imaging (MRI) has long served as the neuroimaging modality of choice for cerebral small vessel disease and VCID because of its sensitivity to a wide range of brain properties, including small structural lesions, connectivity, and cerebrovascular physiology. Despite MRI's widespread use in the VCID field, there have been relatively scant data validating the repeatability and reproducibility of MRI-based biomarkers across raters, scanner types, and time intervals (collectively defined as instrumental validity). The MRI protocols described here address the core MRI sequences for assessing cerebral small vessel disease in future research studies, specific sequence parameters for use across various research scanner types, and rigorous procedures for determining instrumental validity. Another candidate neuroimaging modality considered by MarkVCID is optical coherence tomography angiography (OCTA), a non-invasive technique for directly visualizing retinal capillaries as a marker of the cerebral capillaries. OCTA has theoretical promise as a unique opportunity to visualize small vessels derived from the cerebral circulation, but at a considerably earlier stage of development than MRI. The additional OCTA protocols described here address procedures for determining OCTA instrumental validity, evaluating sources of variability such as pupil dilation, and handling data to maintain participant privacy. MRI protocol and instrumental validation The core sequences selected for the MarkVCID MRI protocol are three-dimensional T1-weighted multi-echo magnetization-prepared rapid-acquisition-of-gradient-echo (ME-MPRAGE), three-dimensional T2-weighted fast spin echo fluid-attenuated-inversion-recovery (FLAIR), two-dimensional diffusion-weighted spin-echo echo-planar imaging (DWI), three-dimensional T2*-weighted multi-echo gradient echo (3D-GRE), three-dimensional T2 -weighted fast spin-echo imaging (T2w), and two-dimensional T2*-weighted gradient echo echo-planar blood-oxygenation-level-dependent imaging with brief periods of CO2 inhalation (BOLD-CVR). Harmonized parameters for each of these core sequences were developed for four 3 Tesla MRI scanner models in widespread use at academic medical centers. MarkVCID project sites are trained and certified for their instantiation of the consortium MRI protocols. Sites are required to perform image quality checks every 2 months using the Alzheimer's Disease Neuroimaging Initiative phantom. Instrumental validation for MarkVCID MRI-based biomarkers is operationally defined as inter-rater reliability, test-retest repeatability, and inter-scanner reproducibility. Assessments of these instrumental properties are performed on individuals representing a range of cerebral small vessel disease from mild to severe. Inter-rater reliability is determined by distribution of an independent dataset of MRI scans to each analysis site. Test-retest repeatability is determined by repeat MRI scans performed on individual participants on a single MRI scanner after a short (1- to 14-day) interval. Inter-scanner reproducibility is determined by repeat MRI scans performed on individuals performed across four MRI scanner models. OCTA protocol and instrumental validation The MarkVCID OCTA protocol uses a commercially available, Food and Drug Administration-approved OCTA apparatus. Imaging is performed on one dilated and one undilated eye to assess the need for dilation. Scans are performed in quadruplicate. MarkVCID project sites participating in OCTA validation are trained and certified by this biomarker's lead investigator. Inter-rater reliability for OCTA is assessed by distribution of OCTA datasets to each analysis site. Test-retest repeatability is assessed by repeat OCTA imaging on individuals on the same day as their baseline OCTA and a different-day repeat session after a short (1- to 14-day) interval. Methods were developed to allow the OCTA data to be de-identified by the sites before transmission to the central data management system. The MarkVCID neuroimaging protocols, like the other MarkVCID procedures, are designed to allow translation to multicenter trials and as a template for outside groups to generate directly comparable neuroimaging data. The MarkVCID neuroimaging protocols are available to the biomedical community and intended to be shared. In addition to the instrumental validation procedures described here, each of the neuroimaging MarkVCID kits will undergo biological validation to determine its ability to measure important aspects of VCID such as cognitive function. The analytic methods for the neuroimaging-based kits and the results of these validation studies will be published separately. The results will ultimately determine the neuroimaging kits' potential usefulness for multicenter interventional trials in small vessel disease-related VCID.


Asunto(s)
Biomarcadores , Enfermedades de los Pequeños Vasos Cerebrales/diagnóstico por imagen , Disfunción Cognitiva/diagnóstico por imagen , Neuroimagen/normas , Anciano , Angiografía , Encéfalo , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Tomografía de Coherencia Óptica
2.
Proc Natl Acad Sci U S A ; 113(17): E2430-9, 2016 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-27071080

RESUMEN

The brain continuously influences and perceives the physiological condition of the body. Related cortical representations have been proposed to shape emotional experience and guide behavior. Although previous studies have identified brain regions recruited during autonomic processing, neurological lesion studies have yet to delineate the regions critical for maintaining autonomic outflow. Even greater controversy surrounds hemispheric lateralization along the parasympathetic-sympathetic axis. The behavioral variant of frontotemporal dementia (bvFTD), featuring progressive and often asymmetric degeneration that includes the frontoinsular and cingulate cortices, provides a unique lesion model for elucidating brain structures that control autonomic tone. Here, we show that bvFTD is associated with reduced baseline cardiac vagal tone and that this reduction correlates with left-lateralized functional and structural frontoinsular and cingulate cortex deficits and with reduced agreeableness. Our results suggest that networked brain regions in the dominant hemisphere are critical for maintaining an adaptive level of baseline parasympathetic outflow.


Asunto(s)
Demencia Frontotemporal/fisiopatología , Lateralidad Funcional/fisiología , Sistema Nervioso Parasimpático/fisiología , Adulto , Anciano , Estudios de Casos y Controles , Femenino , Neuroimagen Funcional , Giro del Cíngulo/fisiología , Corazón/fisiopatología , Frecuencia Cardíaca/fisiología , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Red Nerviosa/fisiología
3.
Aging Dis ; 2023 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-37307817

RESUMEN

The diffusion tensor image analysis along the perivascular space (DTI-ALPS) method was proposed to evaluate glymphatic system (GS) function. However, few studies have validated its reliability and reproducibility. Fifty participants' DTI data from the MarkVCID consortium were included in this study. Two pipelines by using DSI studio and FSL software were developed for data processing and ALPS index calculation. The ALPS index was obtained by the average of bilateral ALPS index and was used for testing the cross-vendor, inter-rater and test-retest reliability by using R studio software. The ALPS index demonstrated favorable inter-scanner reproducibility (ICC=0.77 to 0.95, P < 0.001), inter-rater reliability (ICC=0.96 to 1, P< 0.001) and test-retest repeatability (ICC=0.89 to 0.95, P< 0.001), offering a potential biomarker for in vivo evaluation of GS function.

4.
Alzheimers Dement (Amst) ; 14(1): e12261, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35382232

RESUMEN

Introduction: To describe the protocol and findings of the instrumental validation of three imaging-based biomarker kits selected by the MarkVCID consortium: free water (FW) and peak width of skeletonized mean diffusivity (PSMD), both derived from diffusion tensor imaging (DTI), and white matter hyperintensity (WMH) volume derived from fluid attenuation inversion recovery and T1-weighted imaging. Methods: The instrumental validation of imaging-based biomarker kits included inter-rater reliability among participating sites, test-retest repeatability, and inter-scanner reproducibility across three types of magnetic resonance imaging (MRI) scanners using intra-class correlation coefficients (ICC). Results: The three biomarkers demonstrated excellent inter-rater reliability (ICC >0.94, P-values < .001), very high agreement between test and retest sessions (ICC >0.98, P-values < .001), and were extremely consistent across the three scanners (ICC >0.98, P-values < .001). Discussion: The three biomarker kits demonstrated very high inter-rater reliability, test-retest repeatability, and inter-scanner reproducibility, offering robust biomarkers suitable for future multi-site observational studies and clinical trials in the context of vascular cognitive impairment and dementia (VCID).

5.
Alzheimers Dement (Amst) ; 14(1): e12362, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36523847

RESUMEN

Introduction: To evaluate the clinical validity of free water (FW), a diffusion tensor imaging-based biomarker kit proposed by the MarkVCID consortium, by investigating the association between mean FW (mFW) and executive function. Methods: Baseline mFW was related to a baseline composite measure of executive function (EFC), adjusting for relevant covariates, in three MarkVCID sub-cohorts, and replicated in five, large, independent legacy cohorts. In addition, we tested whether baseline mFW predicted accelerated EFC score decline (mean follow-up time: 1.29 years). Results: Higher mFW was found to be associated with lower EFC scores in MarkVCID legacy and sub-cohorts (p-values < 0.05). In addition, higher baseline mFW was associated significantly with accelerated decline in EFC scores (p = 0.0026). Discussion: mFW is a sensitive biomarker of cognitive decline, providing a strong clinical rational for its use as a marker of white matter (WM) injury in multi-site observational studies and clinical trials of vascular cognitive impairment and dementia (VCID).

6.
Breast J ; 14(6): 574-80, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-19000051

RESUMEN

To assess which specific morphologic features, enhancement patterns, or pharmacokinetic parameters on breast Magnetic Resonance Imaging (MRI) could predict a false-negative outcome of Proton MR Spectroscopy ((1)H MRS) exam in patients with invasive breast cancer. Sixteen patients with invasive ductal carcinoma of the breast were prospectively included and underwent both, contrast-enhanced breast MRI and (1)H MRS examination of the breast. The MR images were reviewed and the lesions morphologic features, enhancement patterns and pharmacokinetic parameters (k21-value) were scored according to the ACR BI-RADS-MRI lexicon criteria. For the in vivo MRS studies, each spectrum was evaluated for the presence of choline based on consensus reading. Breast MRI and (1)H MRS data were compared to histopathologic findings. In vivo (1)H MRS detected a choline peak in 14/16 (88%) cancers. A false-negative (1)H MRS study occurred in 2/16 (14%) cancer patients. K21 values differed between both groups: the 14 choline positive cancers had k21 values ranging from 0.01 to 0.20/second (mean 0.083/second), whereas the two choline-negative cancers showed k21 values of 0.03 and 0.05/second, respectively (mean 0.040/second). Also enhancement kinetics did differ between both groups; typically both cancers that were choline-negative showed a late phase plateau (100%), whereas this was only shown in 5/14 (36%) of the choline positive cases. There was no difference between both groups with regard to morphologic features on MRI. This study showed that false-negative (1)H MRS examinations do occur in breast cancer patients, and that the presence of a choline peak on (1)H MRS as malignancy marker is related to the k21 value of the invasive tumor being imaged.


Asunto(s)
Biomarcadores de Tumor/análisis , Neoplasias de la Mama/diagnóstico , Carcinoma Ductal de Mama/patología , Colina/análisis , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Adulto , Anciano , Neoplasias de la Mama/patología , Reacciones Falso Negativas , Femenino , Humanos , Aumento de la Imagen , Persona de Mediana Edad , Invasividad Neoplásica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
Invest Radiol ; 40(7): 436-41, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15973135

RESUMEN

OBJECTIVE: The objective of this study was to identify magnetic resonance imaging (MRI) characteristics of fibrocystic change (FCC) of the breast. MATERIALS AND METHODS: Fourteen patients with a histopathologic diagnosis of solitary FCC of the breast underwent x-ray mammography and MRI of the breast. Three experienced breast imaging radiologists retrospectively reviewed the MRI findings and categorized the lesions on morphologic and kinetic criteria according to the ACR BI-RADS-MRI Lexicon. RESULTS: The most striking morphologic feature of fibrocystic change was nonmass-like regional enhancement found in 6 of 14 (43%) FCC lesions. Based on morphologic criteria alone, 12 of 14 (86%) lesions were correctly classified as benign. According to analysis of the time-intensity curves, 10 of 14 (71%) FCC lesions were correctly classified as benign. CONCLUSION: Although FCC has a wide spectrum of morphologic and kinetic features on MRI, it most often presents as a mass or a nonmass-like regional enhancing lesion with benign enhancement kinetics.


Asunto(s)
Mama/patología , Enfermedad Fibroquística de la Mama/diagnóstico , Aumento de la Imagen , Imagen por Resonancia Magnética , Adulto , Medios de Contraste , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Mamografía , Persona de Mediana Edad , Estudios Retrospectivos
8.
Med Phys ; 32(6): 1524-8, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16013709

RESUMEN

We developed a fast method to obtain T1 relaxation maps in magnetic resonance imaging (MRI) based on two inversion recovery acquisitions and a reference acquisition, while maintaining high sensitivity by utilizing the full dynamic range of the MRI signal. Optimal inversion times for estimating T1 in the human brain were predicted using standard error propagation theory. In vivo measurements on nine healthy volunteers yielded T1 values of 1094+/-18 ms in gray matter and 746+/-40 ms in white matter, in reasonable agreement with literature values using conventional approaches. The proposed method should be useful for clinical studies because the T1 maps can be obtained within a few seconds.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/patología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Humanos , Procesamiento de Imagen Asistido por Computador , Modelos Estadísticos , Radiografía , Sensibilidad y Especificidad
9.
J Magn Reson Imaging ; 22(4): 520-6, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16142701

RESUMEN

PURPOSE: To identify morphologic and dynamic enhancement magnetic resonance imaging (MRI) features of pure ductal carcinoma in situ (DCIS) by using a new intensity-modulated parametric mapping technique, and to correlate the MRI features with histopathologic findings. MATERIALS AND METHODS: Fourteen patients with pure DCIS on pathology underwent conventional mammography and contrast-enhanced (CE) MRI using the intensity-modulated parametric mapping technique. The MR images were reviewed and the lesions were categorized according to morphologic and kinetic criteria from the ACR BI-RADS-MRI Lexicon, with BI-RADS 4 and 5 lesions classified as suspicious. RESULTS: With the use of a kinetic curve shape analysis, MRI classified seven of 14 lesions (50%) as suspicious, including four with initial-rapid/late-washout and three with initial-rapid/late-plateau. Using morphologic criteria, MRI classified 10/14 (71%) as suspicious, with the most prominent morphologic feature being a regional enhancement pattern. Using the intensity modulated parametric mapping technique, MRI classified 12/14 cases (86%) as suspicious. Parametric mapping identified all intermediate- and high-grade DCIS lesions. CONCLUSION: The intensity-modulated parametric mapping technique for breast MRI resulted in the highest detection rate for the DCIS cases. Furthermore, the parametric mapping technique identified all intermediate- and high-grade DCIS lesions, suggesting that a negative MRI using the parametric mapping technique may exclude intermediate- and high-grade DCIS. This finding has potential clinical implications.


Asunto(s)
Carcinoma in Situ/patología , Carcinoma Ductal/patología , Imagen por Resonancia Magnética/métodos , Adulto , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen , Persona de Mediana Edad , Estudios Retrospectivos
10.
Magn Reson Med ; 48(1): 128-36, 2002 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12111940

RESUMEN

SENSitivity Encoding (SENSE) greatly enhances the quality of diffusion-weighted echo-planar imaging (EPI) by reducing blurring and off-resonance artifacts. Such improvement would also be desirable for diffusion tensor imaging (DTI), but measures derived from the diffusion tensor can be extremely sensitive to any kind of image distortion. Whether DTI is feasible in combination with SENSE has not yet been explored, and is the focus of this study. Using a SENSE-reduction factor of 2, DTI scans in eight healthy volunteers were carried out with regular- and high-resolution acquisition matrices. To further improve the stability of the SENSE reconstruction, a new coil-sensitivity estimation technique based on variational calculus and the principles of matrix regularization was applied. With SENSE, maps of the trace of the diffusion tensor and of fractional anisotropy (FA) had improved spatial resolution and less geometric distortion. Overall, the geometric distortions were substantially removed and a significant resolution enhancement was achieved with almost the same scan time as regular EPI. DTI was even possible without the use of quadrature body coil (QBC) reference scans. Geometry-factor-related noise enhancement was only discernible in maps generated with higher-resolution matrices. Error boundaries for residual fluctuations in SENSE reconstructions are discussed. Our results suggest that SENSE can be combined with DTI and may present an important adjunct for future neuroimaging applications of this technique.


Asunto(s)
Imagen Eco-Planar/métodos , Encéfalo/anatomía & histología , Humanos , Matemática , Modelos Teóricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA