Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Anal Chem ; 94(45): 15781-15789, 2022 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-36377427

RESUMEN

Partitions in digital PCR (dPCR) assays do not reach the detection threshold at the same time. This heterogeneity in amplification results in intermediate endpoint fluorescence values (i.e., rain) and misclassification of partitions, which has a major impact on the accuracy of nucleic acid quantification. Rain most often results from a reduced amplification efficiency or template inaccessibility; however, exactly how these contribute to rain has not been described. We developed and experimentally validated an analytical model that mechanistically explains the relationship between amplification efficiency, template accessibility, and rain. Using Monte Carlo simulations, we show that a reduced amplification efficiency leads to broader threshold cycle (Ct) distributions that can be fitted using a log-normal probability distribution. From the fit parameters, the amplification efficiency can be calculated. Template inaccessibility, on the other hand, leads to a different rain pattern, in which a distinct exponential tail in the Ct distribution can be observed. Using our model, it is possible to determine if the amplification efficiency, template accessibility, or another source is the main contributor of rain in dPCR assays. We envision that this model will facilitate and speed up dPCR assay optimization and provide an indication for the accuracy of the assay.


Asunto(s)
Lluvia , Reacción en Cadena de la Polimerasa/métodos , Método de Montecarlo
2.
Anal Bioanal Chem ; 411(6): 1127-1134, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30637438

RESUMEN

Sulfite is often added to beverages as an antioxidant and antimicrobial agent. In fermented beverages, sulfite is also naturally produced by yeast cells. However, sulfite causes adverse health effects in asthmatic patients and accurate measurement of the sulfite concentration is therefore very important. Current sulfite analysis methods are time- and reagent-consuming and often require costly equipment. Here, we present a system allowing sensitive, ultralow-volume sulfite measurements based on a reusable glass-silicon microdroplet platform on which microdroplet generation, addition of enzymes through chemical-induced emulsion destabilization and pillar-induced droplet merging, emulsion restabilization, droplet incubation, and fluorescence measurements are integrated. In a first step, we developed and verified a fluorescence-based enzymatic assay for sulfite by measuring its analytical performance (LOD, LOQ, the dynamic working range, and the influence of salts, colorant, and sugars) and comparing fluorescent microplate readouts of fermentation samples with standard colorimetric measurements using the 5,5'-dithiobis-(2-nitrobenzoic acid) assay of the standard Gallery Plus Beermaster analysis platform. Next, samples were analyzed on the microdroplet platform, which also showed good correlation with the standard colorimetric analysis. Although the presented platform does not allow stable reinjection of droplets due to the presence of a tight array of micropillars at the fluidics entrances to prevent channel clogging by dust, removing the pillars, and integrating miniaturized pumps and optics in a future design would allow to use this platform for high-throughput, automated, and portable screening of microbes, plant, or mammalian cells. Graphical abstract ᅟ.


Asunto(s)
Bebidas/análisis , Vidrio/química , Técnicas Analíticas Microfluídicas/instrumentación , Silicio/química , Sulfitos/análisis , Diseño de Equipo , Espectrometría de Fluorescencia
3.
Langmuir ; 34(4): 1400-1409, 2018 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-29290116

RESUMEN

N3-functionalized monolayers on silicon wafer substrates are prepared via the controlled vapor-phase deposition of 11-azidoundecyltrimethoxysilanes at reduced pressure and elevated temperature. The quality of the layer is assessed using contact angle, attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR), and ellipsometry measurements. At 60 °C, longer deposition times are needed to achieve monolayers with similar N3 density compared to depositions at 145 °C. The monolayers formed via the vapor phase are denser compared to those formed via a solvent-based deposition process. ATR-FTIR measurements confirm the incorporation of azido-alkyl chains in the monolayer and the formation of siloxane bridges with the underlying oxide at both deposition temperatures. X-ray photon spectroscopy shows that the N3 group is oriented upward in the grafted layer. Finally, the density was determined using total reflection X-ray fluorescence after a click reaction with chlorohexyne and amounts to 2.5 × 1014 N3 groups/cm2. In summary, our results demonstrate the formation of a uniform and reproducible N3-containing monolayer on silicon wafers, hereby providing a functional coating that enables click reactions at the substrate.

4.
Analyst ; 143(11): 2596-2603, 2018 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-29741175

RESUMEN

Clinical laboratory-based nucleic acid amplification tests (NAT) play an important role in diagnosing viral infections. However, laboratory infrastructure requirements and their failure to diagnose at the point-of-need (PON) limit their clinical utility in both resource-rich and -limited clinical settings. The development of fast and sensitive PON viral NAT may overcome these limitations. The scalability of silicon microchip manufacturing combined with advances in silicon microfluidics present an opportunity for development of rapid and sensitive PON NAT on silicon microchips. In the present study, we present rapid and sensitive NAT for a number of RNA and DNA viruses on the same silicon microchip platform. We first developed sensitive (4 copies per reaction) one-step RT-qPCR and qPCR assays detecting HCV, HIV, Zika, HPV 16, and HPV 18 on a benchtop real-time PCR instrument. A silicon microchip was designed with an etched 1.3 µL meandering microreactor, integrated aluminum heaters, thermal insulation trenches and microfluidic channels; this chip was used in all on-chip experiments. Melting curve analysis confirmed precise and localized heating of the microreactor. Following minimal optimization of reaction conditions, the bench-scale assays were successfully transferred to 1.3 µL silicon microreactors with reaction times of 25 min with no reduction in sensitivity, reproducibility, or reaction efficiencies. Taken together, these results demonstrate that rapid and sensitive detection of multiple viruses on the same silicon microchip platform is feasible. Further development of this technology, coupled with silicon microchip-based nucleic acid extraction solutions, could potentially shift viral nucleic acid detection and diagnosis from centralized clinical laboratories to the PON.


Asunto(s)
ADN Viral/análisis , Técnicas Analíticas Microfluídicas , ARN Viral/análisis , Silicio , Técnicas de Amplificación de Ácido Nucleico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Nucleic Acids Res ; 42(7): e50, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24452797

RESUMEN

We demonstrate an approach to optical DNA mapping, which enables near single-molecule characterization of whole bacteriophage genomes. Our approach uses a DNA methyltransferase enzyme to target labelling to specific sites and copper-catalysed azide-alkyne cycloaddition to couple a fluorophore to the DNA. We achieve a labelling efficiency of ∼70% with an average labelling density approaching one site every 500 bp. Such labelling density bridges the gap between the output of a typical DNA sequencing experiment and the long-range information derived from traditional optical DNA mapping. We lay the foundations for a wider-scale adoption of DNA mapping by screening 11 methyltransferases for their ability to direct sequence-specific DNA transalkylation; the first step of the DNA labelling process and by optimizing reaction conditions for fluorophore coupling via a click reaction. Three of 11 enzymes transalkylate DNA with the cofactor we tested (a readily prepared s-adenosyl-l-methionine analogue).


Asunto(s)
Química Clic , Metilasas de Modificación del ADN/metabolismo , ADN/química , Genómica/métodos , Alquilación , ADN/metabolismo , Daño del ADN , Colorantes Fluorescentes , S-Adenosilmetionina/análogos & derivados , S-Adenosilmetionina/química
6.
Nano Lett ; 15(1): 776-82, 2015 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-25514824

RESUMEN

Fast and reversible modulation of ion flow through nanosized apertures is important for many nanofluidic applications, including sensing and separation systems. Here, we present the first demonstration of a reversible plasmon-controlled nanofluidic valve. We show that plasmonic nanopores (solid-state nanopores integrated with metal nanocavities) can be used as a fluidic switch upon optical excitation. We systematically investigate the effects of laser illumination of single plasmonic nanopores and experimentally demonstrate photoresistance switching where fluidic transport and ion flow are switched on or off. This is manifested as a large (∼ 1-2 orders of magnitude) increase in the ionic nanopore resistance and an accompanying current rectification upon illumination at high laser powers (tens of milliwatts). At lower laser powers, the resistance decreases monotonically with increasing power, followed by an abrupt transition to high resistances at a certain threshold power. A similar rapid transition, although at a lower threshold power, is observed when the power is instead swept from high to low power. This hysteretic behavior is found to be dependent on the rate of the power sweep. The photoresistance switching effect is attributed to plasmon-induced formation and growth of nanobubbles that reversibly block the ionic current through the nanopore from one side of the membrane. This explanation is corroborated by finite-element simulations of a nanobubble in the nanopore that show the switching and the rectification.


Asunto(s)
Dispositivos Laboratorio en un Chip , Membranas Artificiales , Nanoporos , Resonancia por Plasmón de Superficie
7.
Nano Lett ; 13(4): 1724-9, 2013 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-23458167

RESUMEN

The ionic properties of a metal-coated silicon nanopore were examined in a nanofluidic system. We observed a strong increase of the ionic noise upon laser light illumination. The effect appeared to be strongly mediated by the resonant excitation of surface plasmons in the nanopore as was demonstrated by means of ionic mapping of the plasmonic electromagnetic field. Evidence from both simulations and experiments ruled out plasmonic heating as the main source of the noise, and point toward photoinduced electrochemical catalysis at the semiconductor-electrolyte interface. This ionic mapping technique described is opening up new opportunities on noninvasive applications ranging from biosensing to energy conversion.


Asunto(s)
Nanopartículas del Metal/química , Nanoporos , Nanoestructuras/química , Silicio/química , Técnicas Biosensibles/métodos , Iones/química , Luz , Resonancia por Plasmón de Superficie
8.
J Biophotonics ; 17(1): e202300279, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37703421

RESUMEN

We demonstrate a portable, compact system to perform absorption-based enzymatic assays at a visible wavelength of 639 nm on a photonic waveguide-based sensor chip, suitable for lab-on-a-chip applications. The photonic design and fabrication of the sensor are described, and a detailed overview of the portable measurement system is presented. In this publication, we use an integrated photonic waveguide-based absorbance sensor to run a full enzymatic assay. An assay to detect creatinine in plasma is simultaneously performed on both the photonic sensor on the portable setup and on a commercial microplate reader for a clinically relevant creatinine concentration range. We observed a high correlation between the measured waveguide propagation loss and the optical density measurement from the plate reader and measured a limit-of-detection of 4.5 µM creatinine in the sensor well, covering the relevant clinical range for creatinine detection.


Asunto(s)
Sistemas de Atención de Punto , Carrera , Creatinina , Diseño de Equipo , Óptica y Fotónica
9.
J Control Release ; 352: 61-73, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36208793

RESUMEN

Intracellular delivery is critical for a plethora of biomedical applications, including mRNA transfection and gene editing. High transfection efficiency and low cytotoxicity, however, are often beyond the capabilities of bulk techniques and synonymous with extensive empirical optimization. Moreover, bulk techniques are not amenable to large screening applications. Here, we propose an expeditious workflow for achieving optimal electroporation-based intracellular delivery. Using the multiplexing ability of a high-definition microelectrode array (MEA) chip, we performed a sequence of carefully designed experiments, multiple linear regression modelling and validation to obtain optimal conditions for on-chip electroporation of primary fibroblasts. Five electric pulse parameters were varied to generate 32 different electroporation conditions. The effect of the parameters on cytotoxicity and intracellular delivery could be evaluated with just two experiments. Most successful electroporation conditions resulted in no cell death, highlighting the low cytotoxicity of on-chip electroporation. The resulting delivery models were then used to achieve dosage-controlled delivery of small molecules, delivery of Cas9-GFP single-guide RNA complexes and transfection with an mCherry-encoding mRNA, resulting in previously unreported high-efficiency, single-cell transfection on MEAs: cells expressed mCherry on 81% of the actuated electrodes, underscoring the vast potential of CMOS MEA technology for the transfection of primary cells.


Asunto(s)
Electroporación , ARN Guía de Kinetoplastida , Microelectrodos , Electroporación/métodos , Transfección , ARN Mensajero
10.
Int J Infect Dis ; 123: 25-33, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35932968

RESUMEN

OBJECTIVES: We performed exhaled breath (EB) and nasopharyngeal (NP) quantitative polymerase chain reaction (qPCR) and NP rapid antigen testing (NP RAT) of SARS-CoV-2 infections with different variants. METHODS: We included immuno-naïve alpha-infected (n = 11) and partly boosted omicron-infected patients (n = 8) as high-risk contacts. We compared peak NP and EB qPCR cycle time (ct) values between cohorts (Wilcoxon-Mann-Whitney test). Test positivity was compared for three infection phases using Cochran Q test. RESULTS: Peak median NP ct was 11.5 (interquartile range [IQR] 10.1-12.1) for alpha and 12.2 (IQR 11.1-15.3) for omicron infections. Peak median EB ct was 25.2 (IQR 24.5-26.9) and 28.3 (IQR 26.4-30.8) for alpha and omicron infections, respectively. Distributions did not differ between cohorts for NP (P = 0.19) or EB (P = 0.09). SARS-CoV-2 shedding peaked on day 1 in EB (confidence interval [CI] 0.0 - 4.5) and day 3 in NP (CI 1.5 - 6.0). EB qPCR positivity equaled NP qPCR positivity on D0-D1 (P = 0.44) and D2-D6 (P = 1.0). It superseded NP RAT positivity on D0-D1 (P = 0.003) and D2-D6 (P = 0.008). It was inferior to both on D7-D10 (P < 0.001). CONCLUSION: Peak EB and nasopharynx shedding were comparable across variants. EB qPCR positivity matched NP qPCR and superseded NP RAT in the first week of infection.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Prueba de COVID-19 , Humanos , Nasofaringe , Sistema Respiratorio
11.
Biosens Bioelectron ; 217: 114663, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36150327

RESUMEN

The SARS-CoV-2 pandemic has highlighted the need for improved technologies to help control the spread of contagious pathogens. While rapid point-of-need testing plays a key role in strategies to rapidly identify and isolate infectious patients, current test approaches have significant shortcomings related to assay limitations and sample type. Direct quantification of viral shedding in exhaled particles may offer a better rapid testing approach, since SARS-CoV-2 is believed to spread mainly by aerosols. It assesses contagiousness directly, the sample is easy and comfortable to obtain, sampling can be standardized, and the limited sample volume lends itself to a fast and sensitive analysis. In view of these benefits, we developed and tested an approach where exhaled particles are efficiently sampled using inertial impaction in a micromachined silicon chip, followed by an RT-qPCR molecular assay to detect SARS-CoV-2 shedding. Our portable, silicon impactor allowed for the efficient capture (>85%) of respiratory particles down to 300 nm without the need for additional equipment. We demonstrate using both conventional off-chip and in-situ PCR directly on the silicon chip that sampling subjects' breath in less than a minute yields sufficient viral RNA to detect infections as early as standard sampling methods. A longitudinal study revealed clear differences in the temporal dynamics of viral load for nasopharyngeal swab, saliva, breath, and antigen tests. Overall, after an infection, the breath-based test remains positive during the first week but is the first to consistently report a negative result, putatively signalling the end of contagiousness and further emphasizing the potential of this tool to help manage the spread of airborne respiratory infections.


Asunto(s)
Técnicas Biosensibles , COVID-19 , COVID-19/diagnóstico , Humanos , Estudios Longitudinales , ARN Viral/análisis , Aerosoles y Gotitas Respiratorias , SARS-CoV-2 , Silicio
12.
Anal Chem ; 83(4): 1307-14, 2011 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-21261273

RESUMEN

We investigated fluorescence quenching and enhancement near gold nanoparticles (GNP) of various sizes using fluorescently labeled hairpin DNA probes of different lengths. A closed hairpin caused intimate contact between the fluorophore and the gold, resulting in an efficient energy transfer (quenching). Upon hybridization with complementary DNA, the DNA probes were stretched yielding a strong increase in fluorescence signal. By carefully quantifying the amount of bound fluorescent probes and the GNP concentrations, we were able to determine the quenching and enhancement efficiencies. We also studied the size and distance dependence theoretically, using both FDTD simulations and the Gersten-Nitzan model and obtained a good agreement between experiments and theory. On the basis of experimental and theoretical studies, we report over 96.8% quenching efficiency for all particle sizes tested and a maximal signal increase of 1.23 after DNA hybridization. The described results also demonstrate the potential of gold nanoparticles for label free DNA sensing.


Asunto(s)
Técnicas Biosensibles/métodos , ADN/análisis , Colorantes Fluorescentes/química , Oro/química , Nanopartículas del Metal/química , Secuencia de Bases , ADN/genética , Sondas de ADN/química , Sondas de ADN/genética , Tamaño de la Partícula , Espectrometría de Fluorescencia
13.
Biosens Bioelectron ; 180: 113135, 2021 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-33690100

RESUMEN

The demand for forensic DNA profiling at the crime scene or at police stations is increasing. DNA profiling is currently performed in specialized laboratories by PCR amplification of Short Tandem Repeats (STR) followed by amplicon sizing using capillary electrophoresis. The need for bulky equipment to identify alleles after PCR presents a challenge for shifting to a decentralized workflow. We devised a novel hybridization-based STR-genotyping method, using Short Tandem Repeat Identification (STRide) probes, which could help tackle this issue. STRide probes are fluorescently labeled oligonucleotides that rely on the quenching properties of guanine on fluorescein derivatives. Mismatches between STRide probes and amplicons can be detected by melting curve analysis after asymmetric PCR. The functionality of the STRide probes was demonstrated by analyzing synthetic DNA samples for the D16S539 locus. Next, STRide probes were developed for five different CODIS core loci (D16S539, TH01, TPOX, FGA, and D7S820). These probes were validated by analyzing 13 human DNA samples. Successful genotyping was obtained using inputs as low as 31 pg of DNA, demonstrating high sensitivity. The STRide probes are ideally suited to be implemented in a microarray and present an important step towards a portable device for fast on-site forensic DNA fingerprinting.


Asunto(s)
Técnicas Biosensibles , Alelos , Dermatoglifia del ADN , Humanos , Repeticiones de Microsatélite/genética , Reacción en Cadena de la Polimerasa
14.
Pharmaceutics ; 13(9)2021 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-34575570

RESUMEN

The use of multimodal contrast agents can potentially overcome the intrinsic limitations of individual imaging methods. We have validated synthetic antiferromagnetic nanoparticles (SAF-NPs) as bimodal contrast agents for in vitro cell labeling and in vivo cell tracking using magnetic resonance imaging (MRI) and computed tomography (CT). SAF-NP-labeled cells showed high contrast in MRI phantom studies (r2* = 712 s-1 mM-1), while pelleted cells showed clear contrast enhancement in CT. After intravenous SAF-NP injection, nanoparticles accumulated in the liver and spleen, as visualized in vivo by significant MRI contrast enhancement. Intravenous injection of SAF-NP-labeled cells resulted in cell accumulation in the lungs, which was clearly detectable by using CT but not by using MRI. SAF-NPs proved to be very efficient cell labeling agents for complementary MRI- and CT-based cell tracking. Bimodal monitoring of SAF-NP labeled cells is in particular of interest for applications where the applied imaging methods are not able to visualize the particles and/or cells in all organs.

15.
J Appl Lab Med ; 6(3): 688-701, 2021 04 29.
Artículo en Inglés | MEDLINE | ID: mdl-33241282

RESUMEN

BACKGROUND: Enzymatic assays are among the most common diagnostic tests performed in the clinical laboratory. Enzymatic substrate analysis is most commonly measured using endpoint methods; however, modulating the reaction kinetics allows fine control of the reaction rate, which can be adjusted based on specific monitoring technologies. METHODS: We developed and optimized an enzymatic method for measurement of creatinine in plasma, using commonly paired enzymes of creatininase (Crtnnase), creatinase (Crtase), sarcosine oxidase (SOX), ascorbate oxidase (AOX), and horseradish peroxidase (HRP). The novel aspect of the assay is that it is fast and uses SOX as the limiting enzyme. The assay performance was assessed with respect to precision, accuracy, and interferences. RESULTS: The intrarun %CV (n = 12) was approximately 5% for each concentration tested, with biases ranging from -3 to -9%. The interrun %CV (n = 39) ranged from 5 to 8%, with biases ranging from -2 to -6%. During the accuracy assessment (n = 127), only 4 samples did not meet the minimum acceptability criteria. Minimal interference was observed, except at low creatinine concentrations with elevated creatine. CONCLUSION: Our novel and versatile enzymatic assay to measure plasma creatinine using kinetic analysis with SOX as the limiting enzyme is rapid (<2 mins), sensitive, and specific and demonstrates excellent concordance with the laboratory standard. We anticipate this rapid kinetic assay to be compatible with emerging technologies in the field of portable diagnostic devices, such as the usage of silicon photonics to monitor biochemical reactions.


Asunto(s)
Pruebas de Enzimas , Creatinina , Humanos , Cinética , Sarcosina-Oxidasa/metabolismo
16.
Nanomaterials (Basel) ; 10(11)2020 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-33114177

RESUMEN

Gold nanoparticles offer the possibility to combine both imaging and therapy of otherwise difficult to treat tumors. To validate and further improve their potential, we describe the use of gold nanostars that were functionalized with a polyethyleneglycol-maleimide coating for in vitro and in vivo photoacoustic imaging (PAI), computed tomography (CT), as well as photothermal therapy (PTT) of cancer cells and tumor masses, respectively. Nanostar shaped particles show a high absorption coefficient in the near infrared region and have a hydrodynamic size in biological medium around 100 nm, which allows optimal intra-tumoral retention. Using these nanostars for in vitro labeling of tumor cells, high intracellular nanostar concentrations could be achieved, resulting in high PAI and CT contrast and effective PTT. By injecting the nanostars intratumorally, high contrast could be generated in vivo using PAI and CT, which allowed successful multi-modal tumor imaging. PTT was successfully induced, resulting in tumor cell death and subsequent inhibition of tumor growth. Therefore, gold nanostars are versatile theranostic agents for tumor therapy.

17.
Talanta ; 192: 220-225, 2019 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-30348381

RESUMEN

PCR enables sensitive and specific detection of infectious disease agents, but application in point-of-care diagnostic testing remains scarce. A compact tool that runs PCR assays in less than a few minutes and that relies on mass-producible, disposable reactors could revolutionize while-you-wait molecular testing. We here exploit well-established semiconductor manufacturing processes to produce silicon ultra-fast quantitative PCR (UF-qPCR) chips that can run PCR protocols with limited assay optimization. A total of 110 clinical samples were analyzed for the detection of group B streptococci using both a validated benchtop and an on-chip qPCR assay. For the on-chip assay, the total reaction time was reduced after optimization to less than 5 min. The standard curve, spanning a concentration range of 5 log units, yielded a PCR efficiency of 94%. The sensitivity obtained was 96% (96/100; CI: 90-98%) and the specificity 70% (7/10; CI: 40-90%). We show that if melting analyses would be integrated, the obtained sensitivity would drop slightly to 93% (CI: 86-96%), while the specificity would increase to 100% (CI: 72% - 100%). In comparison to the benchtop reference qPCR assay performed on a LightCycler©96, the on-chip assay demonstrated a highly significant qualitative (Spearman's rank correlation) and quantitative (linear regression) correlation. Using a mass-producible qPCR chip and limited assay optimization, we were able to develop a validated qPCR protocol that can be carried out in less than five minutes. The analytical performance of the microchip-based UF-qPCR system was shown to match that of a benchtop assay. This is the first report to provide UF-qPCR validation using clinical samples. We demonstrate that qPCR-based while-you-wait testing is feasible without jeopardizing assay performance.


Asunto(s)
ADN/análisis , Dispositivos Laboratorio en un Chip , Reacción en Cadena de la Polimerasa/métodos , Streptococcus agalactiae/aislamiento & purificación , Adulto , Antígenos Bacterianos/genética , Calibración , ADN/genética , Femenino , Humanos , Límite de Detección , Embarazo , Sensibilidad y Especificidad , Streptococcus agalactiae/genética
18.
Sci Rep ; 9(1): 7341, 2019 05 14.
Artículo en Inglés | MEDLINE | ID: mdl-31089203

RESUMEN

The demand to perform forensic DNA profiling outside of centralized laboratories and on the crime scene is increasing. Several criminal investigations would benefit tremendously from having DNA based information available in the first hours rather than days or weeks. However, due to the complexity and time-consuming nature of standard DNA fingerprinting methods, rapid and automated analyses are hard to achieve. We here demonstrate the implementation of an alternative DNA fingerprinting method in a single microchip. By combining PCR amplification and HyBeacon melting assays in a silicon Lab-on-a-chip (LoC), a significant step towards rapid on-site DNA fingerprinting is taken. The small form factor of a LoC reduces reagent consumption and increases portability. Additional miniaturization is achieved through an integrated heating element covering 24 parallel micro-reactors with a reaction volume of 0.14 µl each. The high level of parallelization allows the simultaneous analysis of 4 short tandem repeat (STR) loci and the amelogenin gender marker commonly included in forensic DNA analysis. A reference and crime scene sample can be analyzed simultaneously for direct comparison. Importantly, by using industry-standard semiconductor manufacturing processes, mass manufacturability can be guaranteed. Following assay design and optimization, complete 5-loci profiles could be robustly generated on-chip that are on par with those obtained using conventional benchtop real-time PCR thermal cyclers. Together, our results are an important step towards the development of commercial, mass-produced, portable devices for on-site testing in forensic DNA analysis.


Asunto(s)
Dermatoglifia del ADN/instrumentación , Genética Forense/instrumentación , Dispositivos Laboratorio en un Chip , Reacción en Cadena de la Polimerasa/instrumentación , ADN/análisis , ADN/genética , Diseño de Equipo , Humanos , Desnaturalización de Ácido Nucleico , Silicio/química
19.
Biosens Bioelectron ; 24(1): 72-7, 2008 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-18440798

RESUMEN

The immobilization of DNA strands is an essential step in the development of any DNA biosensor. Self-assembled mixed DNA/alkanethiol films are often used for coupling DNA probes covalently to the sensor surface. Although this strategy is well accepted, the effect of introducing a spacer molecule to increase the distance between the specific DNA sequence and the surface has rarely been assessed. The major goal of this work was to evaluate a number of such spacers and to assess their impact on for example the sensitivity and the reproducibility. Besides the commonly used mercaptohexyl (C(6)) spacer, a longer mercapto-undecyl (C(11)) spacer was selected. The combination of both spacers with tri(ethylene)glycol (TEG) and hexa(ethylene)glycol (HEG) was studied as well. The effect of the different spacers on the immobilization degree as well as on the consecutive hybridization was studied using surface plasmon resonance (SPR). When using the longer C(11) spacer the mixed DNA/alkanethiol films were found to be more densely packed. Further hybridization studies have indicated that C(11) modified probes improve the sensitivity, the corresponding detection limit as well as the reproducibility. In addition two different immobilization pathways, i.e. flow vs. diffusion controlled, were compared with respect to the hybridization efficiency. These data suggest that a flow-assisted approach is beneficial for DNA immobilization and hybridization events. In conclusion, this work demonstrates the considerable impact of spacers on the biosensor performance but also shows the importance of a flow-assisted immobilization approach.


Asunto(s)
Técnicas Biosensibles/métodos , ADN/análisis , Hibridación de Ácido Nucleico/métodos , Cuarzo/química , Sensibilidad y Especificidad , Resonancia por Plasmón de Superficie
20.
Nat Commun ; 9(1): 1733, 2018 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-29712902

RESUMEN

Solid-state nanopores promise a scalable platform for single-molecule DNA analysis. Direct, real-time identification of nucleobases in DNA strands is still limited by the sensitivity and the spatial resolution of established ionic sensing strategies. Here, we study a different but promising strategy based on optical spectroscopy. We use an optically engineered elongated nanopore structure, a plasmonic nanoslit, to locally enable single-molecule surface enhanced Raman spectroscopy (SERS). Combining SERS with nanopore fluidics facilitates both the electrokinetic capture of DNA analytes and their local identification through direct Raman spectroscopic fingerprinting of four nucleobases. By studying the stochastic fluctuation process of DNA analytes that are temporarily adsorbed inside the pores, we have observed asynchronous spectroscopic behavior of different nucleobases, both individual and incorporated in DNA strands. These results provide evidences for the single-molecule sensitivity and the sub-nanometer spatial resolution of plasmonic nanoslit SERS.


Asunto(s)
ADN/análisis , Nanotecnología/métodos , Espectrometría Raman/métodos , Adsorción , Nucleótidos de Desoxiadenina/análisis , Desoxicitidina Monofosfato/análisis , Nucleótidos de Desoxiguanina/análisis , Nanoporos/ultraestructura , Nanotecnología/instrumentación , Espectrometría Raman/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA