Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 24(1): 165-172, 2022 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-34455442

RESUMEN

AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing cardiac pacing. METHODS AND RESULTS: Under the auspice of the Clinical Practice Guideline Quality Indicator Committee of the European Society of Cardiology (ESC), the Working Group for cardiac pacing QIs was formed. The Group comprised Task Force members of the 2021 ESC Clinical Practice Guidelines on Cardiac Pacing and Cardiac Resynchronization Therapy, members of the European Heart Rhythm Association, international cardiac device experts, and patient representatives. We followed the ESC methodology for QI development, which involved (i) the identification of the key domains of care by constructing a conceptual framework of the management of patients receiving cardiac pacing, (ii) the development of candidate QIs by conducting a systematic review of the literature, (iii) the selection of the final set of QIs using a modified-Delphi method, and (iv) the evaluation of the feasibility of the developed QIs. Four domains of care were identified: (i) structural framework, (ii) patient assessment, (iii) pacing strategy, and (iv) clinical outcomes. In total, seven main and four secondary QIs were selected across these domains and were embedded within the 2021 ESC Guidelines on Cardiac Pacing and Cardiac Resynchronization therapy. CONCLUSION: By way of a standardized process, 11 QIs for cardiac pacing were developed. These indicators may be used to quantify adherence to guideline-recommended clinical practice and have the potential to improve the care and outcomes of patients receiving cardiac pacemakers.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiología , Marcapaso Artificial , Adulto , Comités Consultivos , Terapia de Resincronización Cardíaca/efectos adversos , Humanos , Indicadores de Calidad de la Atención de Salud
2.
J Cardiovasc Electrophysiol ; 32(10): 2729-2736, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34374160

RESUMEN

BACKGROUND: Patients with wire and catheter refractory venous occlusion are traditionally referred for pectoral transvenous lead extraction (TLE) to obtain venous access. TLE causes 1-2 mm circumferential mechanical or laser destruction of tissue surrounding the lead(s). This not only exposes the patient to the risk of major complications but also can damage nontargeted leads. We present a series of patients where retained wire femoral lead removal and fibroplasty was used to obtain venous access in patients with refractory obstruction. METHODS: Between 2008 and 2021, we identified 17 patients where retained wire lead removal followed by fibroplasty was used to retain venous access. Demographic and procedural data were obtained by retrospective review of patient charts. RESULTS: We were able to successfully obtain venous access in all 17 patients in whom this technique was attempted. In two patients the target lead was less than or equal to 1 year old. In the remaining 15 patients, the average dwell time of the target lead(s) was 6 years. There were no procedure-related complications, and no changes in the parameters of other leads were noted. CONCLUSION: Retained wire femoral lead removal and fibroplasty is safe and highly efficacious at obtaining venous access in patients with refractory venous occlusion. If the target lead(s) is less than or equal to 1 year old, this technique can help obtain venous access at the time of the initial surgery, hence avoiding the need for TLE. Furthermore, in patients referred for TLE to obtain venous access, this technique by avoiding the use of TLE tools spares the patient of the associated risks.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Remoción de Dispositivos/efectos adversos , Arteria Femoral , Humanos , Estudios Retrospectivos
3.
Europace ; 21(10): 1603-1604, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31353412

RESUMEN

Despite major therapeutic advances over the last decades, complex supraventricular and ventricular arrhythmias (VAs), particularly in the emergency setting or during revascularization for acute myocardial infarction (AMI), remain an important clinical problem. Although the incidence of VAs has declined in the hospital phase of acute coronary syndromes (ACS), mainly due to prompt revascularization and optimal medical therapy, still up to 6% patients with ACS develop ventricular tachycardia and/or ventricular fibrillation within the first hours of ACS symptoms. Despite sustained VAs being perceived predictors of worse in-hospital outcomes, specific associations between the type of VAs, arrhythmia timing, applied treatment strategies and long-term prognosis in AMI are vague. Atrial fibrillation (AF) is the most common supraventricular tachyarrhythmia that may be asymptomatic and/or may be associated with rapid haemodynamic deterioration requiring immediate treatment. It is estimated that over 20% AMI patients may have a history of AF, whereas the new-onset arrhythmia may occur in 5% patients with ST elevation myocardial infarction. Importantly, patients who were treated with primary percutaneous coronary intervention for AMI and developed AF have higher rates of adverse events and mortality compared with subjects free of arrhythmia. The scope of this position document is to cover the clinical implications and pharmacological/non-pharmacological management of arrhythmias in emergency presentations and during revascularization. Current evidence for clinical relevance of specific types of VAs complicating AMI in relation to arrhythmia timing has been discussed.


Asunto(s)
Síndrome Coronario Agudo/cirugía , Terapia de Resincronización Cardíaca/normas , Cardiología , Consenso , Intervención Coronaria Percutánea/normas , Sociedades Médicas , Taquicardia Ventricular/terapia , Síndrome Coronario Agudo/complicaciones , Europa (Continente) , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Pronóstico , Factores de Riesgo , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología
4.
Scand Cardiovasc J ; 53(1): 9-13, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30761919

RESUMEN

OBJECTIVES: To compare the contemporary practice of CRT implantation in Scandinavia and Europe. DESIGN: We used data from The European CRT Survey II to highlight similarities and differences in the practice of CRT implantation between Europe (EUR) and Scandinavia (SCAND) and between the Scandinavian countries Denmark, Norway and Sweden. Implant data from the national pacemaker registries were used to calculate coverage. RESULTS: The coverage was 24% in SCAND and 11% in EUR. SCAND patients were more often referred from another centre and follow-up was less often to be performed at the operating centre. Telemonitoring was more commonly used. More patients had AV-block or pacemaker dependency/expected high RV pacing percentage as indication for CRT. A CRT-P was more commonly used, and ischaemic aetiology was slightly less common. Echocardiography was more often used to determine LVEF, as well as occlusive venography and placing the RV lead first. In DK implanters tended to choose a septal RV position. Quadripolar leads were more often and a test shock less often used. The paced QRS duration was slightly longer and the narrowing of QRS with CRT more limited. Procedure times and preoperative LVEF were similar. CONCLUSIONS: In Scandinavia AV-conduction disturbance and/or a ventricular pacing indication was a more common indication for CRT, suggesting adaptation of the most recent guidelines ahead of their publication. A test shock was almost never performed, in agreement with recent scientific evidence. CRT-P was more often used, the procedures seem more centralized and quadripolar leads were preferred.


Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca/tendencias , Terapia de Resincronización Cardíaca/tendencias , Insuficiencia Cardíaca/terapia , Evaluación de Procesos y Resultados en Atención de Salud/tendencias , Pautas de la Práctica en Medicina/tendencias , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Benchmarking/tendencias , Toma de Decisiones Clínicas , Femenino , Adhesión a Directriz/tendencias , Encuestas de Atención de la Salud , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Sistema de Registros , Países Escandinavos y Nórdicos , Resultado del Tratamiento
10.
Int J Cardiol ; 400: 131809, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38272129

RESUMEN

BACKGROUND: Evidence-based guidelines for cardiac sarcoidosis (CS) regarding use of second- and third-line agents, treatment duration, surveillance and prognostic factors are lacking. OBJECTIVE: To analyze the clinical presentation, diagnostics, treatment, monitoring and clinical outcomes in a Norwegian cohort. METHODS: Using discharge diagnoses between 2017 through 2020 from a large tertiary center, we identified 52 patients with CS. We performed a systematic chart review following a pre-specified checklist. The primary outcome of major cardiovascular events (MACE) was defined as a composite of cardiovascular hospitalization, defibrillator therapy, cardiac transplantation, or death. RESULTS: 18-fluorodeoxyglucose positron emission tomography (FDG-PET) showed pathological tracer uptake in 35/36 (97%) of immunosuppression-naïve patients. Immunosuppressive treatment was administered to 49/52 patients (94%) for a median of 43 (IQR 34) months; 69% were treated with second-line (methotrexate, azathioprine, mycophenolate mofetil) and 25% with third-line (rituximab, infliximab) agents, respectively. Rituximab reduced inflammation as assessed by interval FDG-PET imaging and was overall well tolerated. Median duration to first MACE was 6 (IQR 10) months and 17/23 patients (74%) experienced a MACE within 12 months from CS diagnosis. No mortality was recorded and 20% achieved full remission. Age below the median of 53 years at time of diagnosis was associated with an increased risk of a MACE. CONCLUSION: Long-term immunosuppression including a liberal use of non-steroidal agents, appeared essential in treating CS. Although the burden of cardiovascular events was substantial, the survival was excellent in this contemporary cohort. Prospective randomized studies are urgently needed to define the best therapy for these patients.


Asunto(s)
Cardiomiopatías , Miocarditis , Sarcoidosis , Humanos , Persona de Mediana Edad , Cardiomiopatías/diagnóstico , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones/métodos , Radiofármacos , Rituximab/uso terapéutico , Sarcoidosis/diagnóstico por imagen , Sarcoidosis/epidemiología , Resultado del Tratamiento
11.
Heart Rhythm O2 ; 4(4): 232-240, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37124554

RESUMEN

Background: Transvenous lead extraction (TLE) procedures can be complicated and are associated with a small but significant risk of cardiovascular complications. However, methods and tools vary among centers. Objective: The purpose of this study was to the present the methods and results of pacemaker and implantable cardioverter-defibrillator TLE procedures in our center over a 24-year period. Methods: From April 1997 through 2020, we attempted to extract 2964 leads in 1780 procedures and 1642 patients. We mainly utilized single sheath technique using snaring or mechanical rotational sheaths and steel sheaths when necessary. Difficult procedures were performed by an experienced cardiologist, and close supervision was emphasized. Most of the extractions were performed using local anesthesia with sedation. Results: Median age of patients was 65.0 [interquartile range 20.00] years, and median dwelling time of leads was 5.0 [7.0] years. Clinical success was achieved in 1739 procedures (97.7%) and complete technical success in 2841 leads (95.8%). Clinical success (leaving <4 cm of the lead in the body and achieving the clinical goal for the patient) was achieved for 79 leads (2.7%). TLE failed in 44 leads (1.1%) and 41 procedures (2.3%) among 36 patients (2.2%). There were 23 cases (1.3%) of major complications, with only 1 death directly related to the procedure (<0.1%). In addition, 2 patients with sepsis died within the first 24 hours after the procedure. No caval tears occurred. Conclusion: Single sheath lead extractions utilizing snaring or mechanical rotational sheaths were effective and safe in our high-volume center as performed by experienced operators.

12.
JACC Case Rep ; 3(16): 1769-1773, 2021 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-34825207

RESUMEN

Arrhythmic mitral valve prolapse syndrome is associated with a high risk of death. A 60-year-old man with arrhythmic mitral valve prolapse syndrome was monitored with an implantable loop recorder. Nine months later dyspnea developed, followed by cardiac arrest. Echocardiography showed mitral valve chordal rupture. He underwent successful surgical mitral valve repair. (Level of Difficulty: Intermediate.).

13.
Heart Rhythm ; 18(7): 1064-1073, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33971333

RESUMEN

BACKGROUND: Coronary sinus (CS) ostial atresia/abnormalities prevent access to the CS from the right atrium (RA) for left ventricular (LV) lead implantation. Some patients with CS ostial abnormalities also have a small persistent left superior vena cava (sPLSVC). OBJECTIVE: The purpose of this study was to describe CS ostial abnormalities and sPLSVC as an opportunity for LV lead implantation and unrecognized source of stroke. METHODS: Twenty patients with CS ostial abnormalities and sPLSVC were identified. Clinical information, imaging methods, LV lead implantation techniques, and complications were summarized. RESULTS: Forty percent had at least 1 previously unsuccessful LV lead placement. In 70%, sPLSVC was identified by catheter manipulation and contrast injection in the left brachiocephalic vein, and in 30% by levophase CS venography. In 30%, sPLSVC was associated with drainage from the CS into the left atrium (LA). When associated with CS ostial abnormalities, the sPLSVC diameter averaged 5.6 ± 3 mm. sPLSVC was used for successful LV lead implantation in 90% of cases. In 80%, the LV lead was implanted down sPLSVC, and in 20%, sPLSVC was used to access the CS from the RA. Presumably because of unrecognized drainage from the CS to the LA, 1 patient had a stroke during implantation via sPLSVC. CONCLUSION: When CS ostial abnormalities prevent access to the CS from the RA, sPLSVC can be used to successfully implant LV leads. In some, the CS partially drains into the LA and stroke can occur spontaneously or during lead intervention. It is important to distinguish sPLSVC associated with CS ostial abnormalities from isolated PLSVC.


Asunto(s)
Anomalías Múltiples , Seno Coronario/anomalías , Embolia Intracraneal/prevención & control , Marcapaso Artificial , Vena Cava Superior Izquierda Persistente/terapia , Adulto , Anciano , Seno Coronario/diagnóstico por imagen , Femenino , Humanos , Embolia Intracraneal/etiología , Masculino , Persona de Mediana Edad , Vena Cava Superior Izquierda Persistente/diagnóstico , Radiografía Torácica , Estudios Retrospectivos
20.
JACC Cardiovasc Imaging ; 3(3): 247-56, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20223421

RESUMEN

OBJECTIVES: The aim of this study was to investigate whether myocardial strain echocardiography can predict ventricular arrhythmias in patients after myocardial infarction (MI). BACKGROUND: Left ventricular (LV) ejection fraction (EF) is insufficient for selecting patients for implantable cardioverter-defibrillator (ICD) therapy after MI. Electrical dispersion in infarcted myocardium facilitates malignant arrhythmia. Myocardial strain by echocardiography can quantify detailed regional and global myocardial function and timing. We hypothesized that electrical abnormalities in patients after MI will lead to LV mechanical dispersion, which can be measured as regional heterogeneity of contraction by myocardial strain. METHODS: We prospectively included 85 post-MI patients, 44 meeting primary and 41 meeting secondary ICD prevention criteria. After 2.3 years (range 0.6 to 5.5 years) of follow-up, 47 patients had no and 38 patients had 1 or more recorded arrhythmias requiring appropriate ICD therapy. Longitudinal strain was measured by speckle tracking echocardiography. The SD of time to maximum myocardial shortening in a 16-segment LV model was calculated as a parameter of mechanical dispersion. Global strain was calculated as average strain in a 16-segment LV model. RESULTS: The EF did not differ between ICD patients with and without arrhythmias occurring during follow-up (34 +/- 11% vs. 35 +/- 9%, p = 0.70). Mechanical dispersion was greater in ICD patients with recorded ventricular arrhythmias compared with those without (85 +/- 29 ms vs. 56 +/- 13 ms, p < 0.001). By Cox regression, mechanical dispersion was a strong and independent predictor of arrhythmias requiring ICD therapy (hazard ratio: 1.25 per 10-ms increase, 95% confidence interval: 1.1 to 1.4, p < 0.001). In patients with an EF >35%, global strain showed better LV function in those without recorded arrhythmias (-14.0% +/- 4.0% vs. -12.0 +/- 3.0%, p = 0.05), whereas the EF did not differ (44 +/- 8% vs. 41 +/- 5%, p = 0.23). CONCLUSIONS: Mechanical dispersion was more pronounced in post-MI patients with recurrent arrhythmias. Global strain was a marker of arrhythmias in post-MI patients with relatively preserved ventricular function. These novel parameters assessed by myocardial strain may add important information about susceptibility for ventricular arrhythmias after MI.


Asunto(s)
Arritmias Cardíacas/diagnóstico por imagen , Ecocardiografía , Contracción Miocárdica , Infarto del Miocardio/diagnóstico por imagen , Función Ventricular Izquierda , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/prevención & control , Bélgica , Estudios de Casos y Controles , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Electrocardiografía , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Infarto del Miocardio/fisiopatología , Noruega , Valor Predictivo de las Pruebas , Prevención Primaria , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Recurrencia , Medición de Riesgo , Factores de Riesgo , Prevención Secundaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA