Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Cardiovasc Ultrasound ; 15(1): 9, 2017 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-28376791

RESUMEN

BACKGROUND: Mean or maximal intima-media thickness (IMT) is commonly used as surrogate endpoint in intervention studies. However, the effect of normalization by surrounding or median IMT or by diameter is unknown. In addition, it is unclear whether IMT inhomogeneity is a useful predictor beyond common wall parameters like maximal wall thickness, either absolute or normalized to IMT or lumen size. We investigated the interrelationship of common carotid artery (CCA) thickness parameters and their association with the ipsilateral internal carotid artery (ICA) stenosis degree. METHODS: CCA thickness parameters were extracted by edge detection applied to ultrasound B-mode recordings of 240 patients. Degree of ICA stenosis was determined from CT angiography. RESULTS: Normalization of maximal CCA wall thickness to median IMT leads to large variations. Higher CCA thickness parameter values are associated with a higher degree of ipsilateral ICA stenosis (p < 0.001), though IMT inhomogeneity does not provide extra information. When the ratio of wall thickness and diameter instead of absolute maximal wall thickness is used as risk marker for having moderate ipsilateral ICA stenosis (>50%), 55 arteries (15%) are reclassified to another risk category. CONCLUSIONS: It is more reasonable to normalize maximal wall thickness to end-diastolic diameter rather than to IMT, affecting risk classification and suggesting modification of the Mannheim criteria. TRIAL REGISTRATION: Clinical trials.gov NCT01208025 .


Asunto(s)
Arteria Carótida Común/patología , Grosor Intima-Media Carotídeo , Estenosis Carotídea/patología , Adulto , Anciano , Anciano de 80 o más Años , Arteria Carótida Común/diagnóstico por imagen , Estenosis Carotídea/clasificación , Estenosis Carotídea/diagnóstico por imagen , Estudios de Cohortes , Angiografía por Tomografía Computarizada , Femenino , Humanos , Masculino , Persona de Mediana Edad , Medición de Riesgo , Sensibilidad y Especificidad , Ultrasonografía
2.
Ultrasound Med Biol ; 44(5): 986-994, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29477746

RESUMEN

To properly assess morphologic and dynamic parameters of arteries and plaques, we propose the concept of orthogonal distance measurements, that is, measurements made perpendicular to the local lumen axis rather than along the ultrasound beam (vertical direction for a linear array). The aim of this study was to compare orthogonal and vertical artery and lumen diameters at the site of a plaque in the common carotid artery (CCA). Moreover, we investigated the interrelationship of orthogonal diameters and plaque size and the association of artery parameters with plaque echogenicity. In 29 patients, we acquired a longitudinal B-mode ultrasound recording of plaques at the posterior CCA wall. After semi-automatic segmentation of end-diastolic frames, diameters were extracted orthogonally along the lumen axis. To establish inter-observer variability of diameters obtained at the location of maximal plaque thickness, a second observer repeated the analysis (subset N = 21). Orthogonal adventitia-adventitia and lumen diameters could be determined with good precision (coefficient of variation: 1%-5%. However, the precision of the change in lumen diameter from diastole to systole (distension) at the site of the plaque was poor (21%-50%). The orthogonal lumen diameter was significantly smaller than the vertical lumen diameter (p <0.001). Surprisingly, the plaques did not cause outward remodeling, that is, a local increase in adventitia-adventitia distance at the site of the plaque. The intra- and inter-observer precision of diastolic-systolic plaque compression was poor and of the same order as the standard deviation of plaque compression. The orthogonal relative lumen distension was significantly lower for echogenic plaques, indicating a higher stiffness, than for echolucent plaques (p <0.01). In conclusion, we illustrated the feasibility of extracting orthogonal CCA and plaque dimensions, albeit that the proposed approach is inadequate to quantify plaque compression.


Asunto(s)
Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Arteria Carótida Común/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico por imagen , Ultrasonografía/métodos , Anciano , Enfermedades de las Arterias Carótidas/patología , Arteria Carótida Común/patología , Femenino , Humanos , Masculino , Placa Aterosclerótica/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA