Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Revista
País de afiliación
Intervalo de año de publicación
1.
J Urol ; 183(2): 673-7, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20022047

RESUMEN

PURPOSE: Surgical simulation technology may efficiently train and accurately assess the acquisition of many skills. Surgical simulators often lack realism and can be expensive at $3,000 to more than $60,000. We assessed the face, content and construct validity of a newly developed, anatomically accurate, reasonably priced high fidelity ureteroscopy and renoscopy trainer. MATERIALS AND METHODS: A total of 46 participants, including attending urologists, urology residents, medical students and industry representatives, assessed the face and content validity of the simulator using a standard questionnaire. Ten experienced ureteroscopists with greater than 30 procedures per year and 10 novice ureteroscopists with 0 were assessed on the ability to perform flexible ureteroscopy, renoscopy and intrarenal basket extraction of a lower pole calculus using the adult ureteroscopy trainer (Ideal Anatomic Modeling, Holt, Michigan). Subject performance was assessed by an experienced ureteroscopist using a checklist, global rating scale and time to task completion. RESULTS: Of participants 100% rated the trainer as realistic and easy to use, and thought it was a good training tool, 98% thought that it would serve as a good training format and 96% would recommend it to urology trainees. All participants recommended it for use in residency programs and 96% would or would have used it during residency. Only 37.5% vs 100% of experienced vs novice ureteroscopists would use it to practice. Of participants 9% foresaw a problem with the trainer. On the trainer experienced ureteroscopists scored significantly higher on the global rating scale (mean +/- SD 33.1 +/- 1.3 vs 15.0 +/- 2.7, p <0.0001) and checklist (4.1 +/- 1.0 vs 2.4 +/- 1.1, p = 0.004), and required less time to complete the task (141.2 +/- 40.1 vs 447.2 +/- 301.7 seconds, p = 0.01). CONCLUSIONS: Our preliminary study suggests the face, content and construct validity of the adult ureteroscopy trainer as a high fidelity ureteroscopy and renoscopy trainer.


Asunto(s)
Simulación por Computador , Instrucción por Computador , Educación Médica/métodos , Riñón , Ureteroscopía , Adulto , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA