Knee Surg Sports Traumatol Arthrosc ; 32(6): 1492-1506, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38643397

RESUMEN

PURPOSE: The pivot-shift test is used to clinically assess knee instability in patients with anterior cruciate ligament (ACL) lesions; however, it has low interobserver reliability. Dynamic radiostereometry (dRSA) is a highly precise and noninvasive method for the objective evaluation of joint kinematics. The purpose of this study was to quantify precise knee kinematics during a pivot-shift test using dRSA imaging. METHOD: Eight human donor legs, including hemipelvises, were evaluated. Arthroscopic intervention was performed inducing ligament lesions in the ACL, and anterolateral ligament (ALL) section was performed as a capsular incision. The pivot-shift test was recorded with dRSA on knees with intact ligaments, ACL-deficient and ACL + ALL-deficient knees. RESULTS: A pivot-shift pattern was identifiable after ligament lesion, as a change in tibial posterior drawer velocity from 7.8 mm/s (95% CI: 3.7; 11.9) in ligament intact knees to 30.4 mm/s (95% CI 23.0; 38.8) after ACL lesion to 35.1 mm/s (95% CI 23.4; 46.7) after combined ACL-ALL lesion. The anterior-posterior drawer excursion increased from 2.8 mm (95% CI 2.1; 3.4) in ligament intact knees to 7.2 mm (95% CI 5.5; 8.9) after ACL lesion to 7.6 mm (95% CI 5.5; 9.8) after combined lesion. A statistically significant increase in tibial external rotation towards the end of the pivot-shift motion was observed when progressing from intact to ACL + ALL-deficient knees (p < 0.023). CONCLUSION: This experimental study demonstrates the feasibility of dRSA to objectively quantify the kinematic laxity patterns of the knee during the pivot-shift test. The dynamic parameters obtained through dRSA revealed the kinematic changes from ACL to combined ACL-ALL ligament lesion. LEVEL OF EVIDENCE: Not applicable.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Inestabilidad de la Articulación , Articulación de la Rodilla , Análisis Radioestereométrico , Humanos , Inestabilidad de la Articulación/fisiopatología , Inestabilidad de la Articulación/diagnóstico , Fenómenos Biomecánicos , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/diagnóstico por imagen , Lesiones del Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/fisiopatología , Rotación , Masculino , Femenino , Cadáver , Rango del Movimiento Articular/fisiología , Ligamento Cruzado Anterior/fisiopatología , Ligamento Cruzado Anterior/cirugía , Reproducibilidad de los Resultados , Persona de Mediana Edad , Anciano
2.
Clin Anat ; 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38715464

RESUMEN

The dysplastic hip is characterized by incomplete coverage of the femoral head, resulting in increased risk of early osteoarthritis. The morphological variation of the hip joint is diverse and clear differences exist between females and males. The aim of this observational study was therefore to investigate the relationship between the morphology of the hip, sex, and hip dysplasia using a three-dimensional model. Statistical shape models of the combined femur and pelvic bones were created from bilateral hips of 75 patients. Using manual angle measurements and regression analysis, the characteristic shape differences associated with sex and hip dysplasia were determined. The model showed clear differences associated with sex and hip dysplasia. We found that the acetabular anteversion in females was significantly higher (p < 0.0001) than in males while no significant difference in acetabular anteversion was found between normal and dysplastic hips (p = 0.11). The model showed that decreased acetabular anteversion resulted in the appearance of the cross-over sign and the prominent ischial spine sign commonly associated with retroversion. Sex could be predicted with an area under the curve of 0.99 and hip dysplasia could be predicted with an area under the curve of ≥0.73. Our findings suggest that retroversion is a result of decreased anteversion of the acetabulum and is primarily associated with sex. This finding should be taken into account during the reorientation of the acetabulum in the surgical treatment of hip dysplasia.

3.
Acta Orthop ; 95: 498-504, 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39240016

RESUMEN

BACKGROUND AND PURPOSE:  The duration of antibiotic coverage in hand tissues during surgery is unknown. We investigated the time the free concentration of cefuroxime was above the minimal inhibitory concentration (fT>MIC) of 4 µg/mL in hand tissues after single and repeated administration. METHODS:  In a prospective, unblinded randomized study 16 patients (13 female, age range 51-80 years) underwent trapeziectomy. Microdialysis catheters were placed in the metacarpal bone (primary effect parameter), synovial sheath, and subcutaneous tissue. Patients were randomized to postoperative administration of either intravenous single administration of cefuroxime (1,500 mg) (Group 1, n = 8) or repeated dosing (2 x 1,500 mg) with a 4 h interval (Group 2, n = 8). Samples were taken over 8 h. RESULTS: The fT>MIC of 4 µg/mL was found to be significantly longer in the metacarpal bone in Group 2 compared with Group 1 with a mean difference of 199 min (95% confidence interval 158-239). The same trend was evident in the remaining compartments. A concentration of 4 µg/mL was reached in all compartments in both groups within a mean time of 6 min (range 0-27 min). In Group 1, the mean concentrations decreased below 4 µg/mL between 3 h 59 min and 5 h 38 min. CONCLUSION:  The fT>MIC was longer after repeated administration compared with single administration in all compartments. A single administration of cefuroxime 1,500 mg provided antimicrobial hand tissue coverage for a minimum of 3 h 59 min. Cefuroxime administration in hand surgeries should be done minimum 27 min prior to incision to achieve sufficient coverage in all individuals. Cefuroxime readministration should be considered in hand surgeries lasting longer than 4 h from time of administration.


Asunto(s)
Antibacterianos , Cefuroxima , Hueso Trapecio , Humanos , Cefuroxima/administración & dosificación , Cefuroxima/farmacocinética , Femenino , Persona de Mediana Edad , Anciano , Masculino , Antibacterianos/administración & dosificación , Antibacterianos/farmacocinética , Estudios Prospectivos , Anciano de 80 o más Años , Hueso Trapecio/cirugía , Mano/cirugía , Huesos del Metacarpo/cirugía , Esquema de Medicación
4.
Acta Orthop ; 95: 121-129, 2024 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-38391197

RESUMEN

BACKGROUND AND PURPOSE: Cementless arthroplasty fixation relies on early bone ingrowth and may be poor in patients with low proximal tibial bone density or abnormal bone turnover. We aimed first to describe the baseline bone properties in patients undergoing medial unicompartmental knee replacement (UKR), and second to investigate its association with cemented and cementless tibial component migration until 2 years. METHODS: A subset investigation of 2 patient groups from a 3-armed randomized controlled trial was conducted. There were 26 cemented and 25 cementless medial UKRs with twin-pegged femoral components. Volumetric bone mineral density (vBMD) and microstructure of the excised medial tibial plateau were ascertained with µCT. Bone turnover was estimated using dynamic histomorphometry (eroded surface/bone surface = ES/BS, osteoid surface/bone surface = OS/BS, mineralizing surface/bone surface = MS/BS). Tibial component migration in 4 feature points was followed for 2 years with radiostereometry. RESULTS: At the 2-year follow-up, the cementless tibial components migrated 0.38 mm (95% confidence interval [CI] 0.14-0.62) total translation more than the cemented components at the posterior feature point. The greatest migration in the cementless group was subsidence at the posterior feature point of 0.66 mm (CI 0.48-0.84) until 6 weeks, and from 3 months the components were stable. Cemented tibial components subsided very little. Between 1- and 2-year follow-ups, no cementless but 4 cemented tibial components revealed continuous migration. OS/BS was half of the ES/BS. No µCT or histomorphometric parameters showed any clinically relevant correlation with tibial component migration at the posterior feature point for either cemented or cementless UKR at 6 weeks' or 2 years' follow-up after adjustment for age, BMI, and sex. CONCLUSION: Preoperative vBMD, bone turnover, and microstructure were not associated with postoperative tibial component migration of cemented and cementless medial UKR.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Densidad Ósea , Prótesis de la Rodilla/efectos adversos , Falla de Prótesis , Articulación de la Rodilla/cirugía , Cementos para Huesos , Diseño de Prótesis , Resultado del Tratamiento , Osteoartritis de la Rodilla/cirugía
5.
Acta Orthop ; 95: 256-267, 2024 05 30.
Artículo en Inglés | MEDLINE | ID: mdl-38819193

RESUMEN

Opening remarks: These guidelines are the result of discussions within a diverse group of RSA researchers. They were approved in December 2023 by the board and selected members of the International Radiostereometry Society to update the guidelines by Valstar et al. [1]. By adhering to these guidelines, RSA studies will become more transparent and consistent in execution, presentation, reporting, and interpretation. Both authors and reviewers of scientific papers using RSA may use these guidelines, summarized in the Checklist, as a reference. Deviations from these guidelines should have the underlying rationale stated.


Asunto(s)
Análisis Radioestereométrico , Tomografía Computarizada por Rayos X , Humanos , Falla de Prótesis , Guías de Práctica Clínica como Asunto
6.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 933-945, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35809105

RESUMEN

PURPOSE: New total knee arthroplasty implant designs attempt to normalize kinematics patterns that may improve functional performance and patient satisfaction. It was hypothesized that a more medial congruent (MC) anatomic bearing design (1) influences the tibiofemoral kinematics and (2) enhances articular congruency compared to a standard symmetrical cruciate retaining (CR) bearing design. METHODS: In this double-blinded randomized study, 66 patients with knee osteoarthritis were randomly included in two groups: MC (n = 31) and CR (n = 33). Clinical characteristics such as knee ligament lesions and knee osteoarthritis scores were graded on preoperative magnetic resonance imaging and radiography. At the 1-year follow-up, dynamic radiostereometric analysis was used to assess tibiofemoral joint kinematics and articulation congruency. Patient-reported outcome measures, Oxford Knee Score, the Forgotten Joint Score, and the Knee Osteoarthritis Outcome Score, were assessed preoperatively and at the 1-year follow-up. RESULTS: Compared to the CR bearing, the MC bearing displayed an offset with approximately 3 mm greater anterior tibial drawer (p < 0.001) during the entire motion, and up to approximately 3.5 degrees more tibial external rotation (p = 0.004) from mid-swing to the end of the gait cycle at the 1-year follow-up. Furthermore, the congruency area in the joint articulation was larger during approximately 80% of the gait cycle for the MC bearing compared to the CR. The patient-reported outcome measures improved (p < 0.001), but there were no differences between groups. In addition, there were no differences in clinical characteristics and there were no knee revisions or recognized deep infections during follow-up. CONCLUSION: The study demonstrates that the MC-bearing design changes tibiofemoral kinematics and increases the area of congruency towards more native knee kinematics than the CR bearing. In perspective this may contribute to a more stabilized knee motion, restoring the patient's confidence in knee function during daily activities.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Análisis Radioestereométrico , Osteoartritis de la Rodilla/cirugía , Polietileno , Fenómenos Biomecánicos , Articulación de la Rodilla/cirugía , Ligamento Cruzado Anterior/cirugía , Marcha , Rango del Movimiento Articular
7.
J Shoulder Elbow Surg ; 32(2): 292-301, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35998782

RESUMEN

BACKGROUND: The aim of this prospective study was to investigate bone mineral density (BMD) changes in the proximal humerus of the shoulder during a healing period of 12 months after displaced 3- or 4-part proximal humerus fractures treated with open reduction and internal fixation (ORIF) with an anatomic angular stable locking plate and the influence on fracture healing and functional outcomes. METHODS: In a prospective multicenter study, 36 patients (29F and 7M, age range: 38-83) with unilateral displaced 3- or 4-part proximal humerus fractures were included for ORIF. Dual-energy x-ray absorptiometry for osteoporosis status was employed. Postoperative and 6-week, 3-, 6-, and 12-month shoulder radiographs and dual-energy x-ray absorptiometry of the shoulder with BMD measures in 4 templated regions of interest (ROIs) were performed. Functional outcomes, Western Ontario Osteoarthritis of the Shoulder index, Constant score, visual analog scale pain (VAS), and 36-Item Short Form Survey, were collected. RESULTS: A total of 17 of 36 patients had osteoporosis. We found no differences in BMD changes, functional outcomes, radiology, or need for revision surgery between the osteoporosis and nonosteoporosis groups. The BMD values gradually declined from baseline to 3-month follow-up in all 4 ROIs of the operated shoulders. All 4 ROIs in the operated shoulder presented with a reduction in BMD at 3, 6, and 12 months compared with baseline, whereas no significant BMD changes were seen in the healthy shoulder during the study period. The functional outcomes displayed an increase in Constant score from 3 to 12 months, but a decrease in domains of the 36-Item Short Form Survey from preinjury to 12 months (physical functioning, general health, and bodily pain). Preinjury and 12-month Western Ontario Osteoarthritis of the Shoulder index, VAS pain at rest, and VAS pain at activity were comparable. CONCLUSION: BMD changes appeared swiftly in the proximal humerus, after the treatment of displaced 3- or 4-part fractures with ORIF, particularly affecting the proximal diaphysis of the humerus. Shoulder function was restored to preinjury levels for most of the patients. Osteoporosis may not be regarded as a contraindication for the treatment of displaced 3- or 4-part fractures with ORIF.


Asunto(s)
Fracturas del Húmero , Osteoartritis , Osteoporosis , Fracturas del Hombro , Humanos , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Densidad Ósea , Hombro , Estudios Prospectivos , Estudios de Seguimiento , Osteoporosis/complicaciones , Húmero , Placas Óseas , Curación de Fractura , Dolor , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía , Fijación Interna de Fracturas , Resultado del Tratamiento
8.
Arch Orthop Trauma Surg ; 143(9): 5957-5965, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36802237

RESUMEN

INTRODUCTION: Dual mobility implants have been successful in reducing postoperative hip dislocation but mid-term results of cup migration and polyethylene wear are missing in the literature. Therefore, we measured migration and wear at 5-year follow-up using radiostereometric analysis (RSA). MATERIALS AND METHODS: A cohort of 44 patients (mean age 73, 36 female) with heterogeneous indications for hip arthroplasty but all with a high risk of hip dislocation received total hip replacement (THA) with The Anatomic Dual Mobility X3 monoblock acetabular construct and a highly crosslinked polyethylene liner. RSA images and Oxford Hip Scores were obtained perioperatively and 1, 2, and 5 years postoperatively. Cup migration and polyethylene wear were calculated using RSA. RESULTS: Mean 2-year proximal cup translation was 0.26 mm (95% CI 0.17; 0.36). Proximal cup translation was stable from 1- to 5-year follow-up. Mean 2-year cup inclination (z-rotation) was 0.23° (95% CI - 0.22; 0.68) and was greater in patients with osteoporosis compared to patients without osteoporosis (p = 0.04). Using 1-year follow-up as baseline, the 3D polyethylene wear rate was 0.07 mm/year (0.05; 0.10). Oxford hip scores improved 19 (95% CI 14; 24) points from mean 21 (range 4; 39) at baseline, to 40 (9; 48) 2 years postoperatively. There were no progressive radiolucent lines > 1 mm. There was 1 revision for offset correction. CONCLUSIONS: Anatomic Dual Mobility monoblock cups were well-fixed, the polyethylene wear rate was low, and the clinical outcomes were good until 5-year follow-up suggesting good implant survival in patients of different age groups and with heterogeneous indications for THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Humanos , Femenino , Polietileno , Luxación de la Cadera/cirugía , Falla de Prótesis , Diseño de Prótesis , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Estudios de Seguimiento
9.
Arch Orthop Trauma Surg ; 143(5): 2475-2484, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35596021

RESUMEN

INTRODUCTION: Hip fracture patients are fragile, and the majority fail to fully recover to their pre-fracture functional level, resulting in an increase in institutionalization. We aimed to investigate risk factors for being dependent at discharge and for failure to return to independent living 12 months after a hip fracture. MATERIALS AND METHODS: From 2011 to 2017, all surgically treated hip fracture patients admitted from their own homes were included in this prospective cohort study. Patient characteristics were registered, including age, sex, lifestyle, comorbidities, pre-fracture New Mobility Score (NMS), biochemical measures, fracture type, and surgical method. Dependency was measured at discharge using a cumulated ambulatory score (CAS < 6) and the timed-up-and-go test (TUG > 20 s). At 12 months, patients were interviewed regarding residence, NMS, and care needs. Multivariable logistic regression was used, reporting odds ratio (OR) with 95% confidence intervals (CI). RESULTS: A total of 2006 patients were included in the study with data regarding their hospital stay and discharge. In all, 1342 patients underwent follow-up at 12 months. The risk factors found to be associated with dependency at discharge were mostly static. Modifiable variables associated with dependency at discharge (CAS < 6) were hypoalbuminemia (OR: 1.94, 95% CI 1.38-2.71), not having been mobilized to standing within 24 h (OR: 1.88, 95% CI 1.12-3.15), and general anesthesia (OR: 1.35, 95% CI 1.07-1.71). Failure to return to independent living at 12 months was found in 10% of the patients, and was primarily associated with patient characteristics and proxy variables for comorbidities, but also with dependency at discharge (CAS < 6). CONCLUSIONS: Mobilizing patients to standing within 24 h from hip fracture surgery was vital in maximizing short-term functional recovery. Failure to return to independent living was seen in the frailest patients. However, the majority remained in their own home with little increase in care needs.


Asunto(s)
Fracturas de Cadera , Vida Independiente , Humanos , Actividades Cotidianas , Estudios Prospectivos , Equilibrio Postural , Estudios de Tiempo y Movimiento , Fracturas de Cadera/cirugía , Fracturas de Cadera/complicaciones
10.
Arch Orthop Trauma Surg ; 143(2): 1071-1080, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35113240

RESUMEN

INTRODUCTION: The Exeter short stem (ESS) is 25 mm shorter than the standard length v40 Exeter stem (Stryker) and intended for a narrow femoral diaphysis. The purpose of the study was to evaluate the migration pattern of the cemented ESS. MATERIAL AND METHOD: In a prospective single-center cohort study, 23 patients (21 female) mean age 78 (range 70-89) with hip osteoarthritis and Dorr Type A femurs were included. Preoperative DXA was used to group patients into normal (> - 1) and low (< - 1) T-score. Components were the collarless polished double-tapered Exeter short stem type N°1 L125. Patients were followed for 2 years with model-based RSA (stem migration), regular hip radiographs (stem position and cementation quality), Oxford Hip Score (OHS) and VAS pain. RESULTS: At 2-year follow-up, the stems subsided 1.48 mm (CI 95% 1.69; 1.26) and retroverted 0.45° (CI 95% 0.01; 0.88). From 12 to 24 months, stem subsidence was 0.18 mm (CI 95% 0.1; 0.25) (p = 0.001) and retroversion was - 0.04° (CI 95% - 0.27; 0.18) (p = 0.70). T-score and stem subsidence correlated (rho = 0.48; p = 0.025) and patients with normal T-score (n = 7) had 0.42 mm (CI 95% - 0.01; 0.85) less subsidence as compared to patients with low T-score (n = 15) (p = 0.054). Stems in varus position (n = 9) subsided 1.7 mm (CI 95% 1.35; 2.05) compared to 1.33 mm (CI 95% 1.05; 1.60) for stems in neutral position (n = 13) (p = 0.07). Postoperative cementation quality did not influence 2-year stem migration. OHS improved to 40.7 (CI 95% 36.8; 44.7) and VAS pain at rest and activity decreased to 5 mm and 10 mm, respectively (p < 0.001). CONCLUSION: The 2-year migration pattern of the cemented ESS was similar to reports for the cemented standard length Exeter stem. Low preoperative T-score and varus stem-position showed a tendency for higher stem migration and should be studied as risk factors for failure in larger studies of cemented polished stems.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Femenino , Anciano , Análisis Radioestereométrico , Prótesis de Cadera/efectos adversos , Estudios de Seguimiento , Estudios Prospectivos , Estudios de Cohortes , Diseño de Prótesis , Dolor/etiología , Falla de Prótesis
11.
Arch Orthop Trauma Surg ; 143(9): 5919-5926, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36422666

RESUMEN

BACKGROUND: Radiostereometric Analysis (RSA) is used to measure fixation of joint prosthesis. This study compared radiation dose and image quality of a digital radiography (DR) RSA system and a computed radiography (CR) RSA system in a clinical setting. METHODS: RSA recordings of 24 hips and shoulders were analyzed. We compared two systems: (1) Arcoma T0 with ST-VI image plates and Profect CR-IR 363 reader to (2) AdoraRSA with CXDI-70C wireless DR detectors in a clinical uniplanar RSA set-up with a ± 20 degrees tube angulation and 35 cm × 43 cm detectors. Effective dose was calculated using dedicated software. Image quality was evaluated using calibration errors as calculated by the RSA software. RESULTS: The mean dose for hips was 0.14 (SD 0.04) mSv in the CR system and 0.05 (SD 0.02) mSv in the DR system. The mean dose for shoulders was 0.16 (SD 0.07) mSv in the CR system and 0.09 (SD 0.03) mSv in the DR system. Radiation dose was 64% (p < 0.001) and 43% (p = 0.03) lower in the DR system compared with the CR system for hip and shoulder RSA, respectively. Image quality was better for the DR system with 60-80% less calibration errors compared to the CR system. CONCLUSION: Owing to highly efficient detectors and added filtration at the x-ray tubes, the DR system considerably reduced radiation dose compared with the CR system without compromising image quality. Based on the findings in this study, we recommend replacing CR RSA systems with DR RSA systems. REGISTRATION: Patients were selected from clinical studies performed on the two systems and approved by the local ethics committee [20060165, M-20100112, M-20070082, M-20110224, and 20070258] and registered with ClinicalTrials.gov [NCT00408096, NCT01289834, NCT00913679, NCT02311179, and NCT00679120].


Asunto(s)
Artroplastia de Reemplazo , Prótesis Articulares , Humanos , Dosis de Radiación , Intensificación de Imagen Radiográfica , Análisis Radioestereométrico/métodos
12.
Arch Orthop Trauma Surg ; 143(9): 5967-5976, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36802238

RESUMEN

BACKGROUND: Pseudotumors and muscle atrophy have been associated with metal-on-metal (MoM) resurfacing hip arthroplasty (RHA). We aimed to investigate the influence of the anterolateral (AntLat) and the posterior (Post) surgical approach on the location, grade and prevalence of pseudotumors and muscle atrophy in MoM RHA. PATIENTS AND METHODS: Forty-nine patients were randomized to MoM RHA by the AntLat (n = 25) or the Post (n = 24) approach at Aarhus University Hospital. Patients underwent metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) scans for investigation of location, grade and prevalence of pseudotumors and muscle atrophy. Plain radiographs, metal-ions concentrations and clinical outcome scores were evaluated to compare outcomes of the surgical approaches. RESULTS: MRI-detected pseudotumors were seen in 7 of 18 patients (39%) in the AntLat group and in 12 of 22 patients (55%) in the Post group (p = 0.33). Pseudotumors were mainly located anterolaterally to the hip joint in the AntLat group and postero-lateral to the hip joint in the Post group. Higher grades of muscle atrophy of the caudal part of the gluteus medius and minimus (p < 0.004) were seen in the AntLat group, and higher grades of muscle atrophy of the small external rotators were seen in the Post group (p < 0.001). The AntLat group had higher anteversion angles of mean 15.3° (range 6.1-7.5) versus mean 11.5° (range 4.9-22.5) in the Post group (p = 0.02). Metal-ion concentrations and clinical outcome scores were similar between groups (p > 0.08). CONCLUSION: Muscle atrophy and pseudotumor location after MoM RHA follow the surgical approach used for implantation. This knowledge may help differentiate between "normal postoperative appearance" and "MoM disease."


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Metales , Imagen por Resonancia Magnética/métodos , Atrofia Muscular/diagnóstico por imagen , Atrofia Muscular/etiología , Diseño de Prótesis , Cobalto
13.
Arch Orthop Trauma Surg ; 143(12): 7169-7183, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37568057

RESUMEN

BACKGROUND: The component design and fixation method of joint arthroplasty may affect component migration and survival. The aim of this study was to compare fixation of cementless twin-peg (CLTP), cemented twin-peg (CTP) and cemented single-peg (CSP) femoral components of medial unicompartmental knee replacement (UKR). METHODS: Eighty patients (mean age = 63 years, 48 males) with medial knee osteoarthritis were randomized in three ways to CLTP (n = 25), CTP (n = 26) or CSP (n = 29) femoral UKR components. The patients were followed 5 years postoperatively with RSA, bone mineral density (BMD), PROMs and radiological evaluation of radiolucent lines (RLL), femoral component flexion angle and complications. RESULTS: At the 5-year follow-up, femoral component total translation was comparable between the three groups (p = 0.60). Femoral component internal rotation was 0.50° (95% CI 0.3; 0.69) for the CLTP group, 0.58° (95% CI 0.38; 0.77) for the CTP group and 0.25° (95% CI 0.07; 0.43) for the CSP group (p = 0.01). BMD decreased peri-prosthetically (range - 11.5%; - 14.0%) until 6-month follow-up and increased toward the 5-year follow-up (range - 3.6%; - 5.8%). BMD change did not correlate with component migration. Lower flexion angle was correlated with higher 5-year subsidence, total translation, varus rotation and maximum total point motion (p = 0.01). Two patients (1 CLTP, 1 CTP) had RLL in the posterior zone. There were two revisions. CONCLUSION: At 5-year follow-up, fixation of UKA femoral components with twin-peg was not superior to the single-peg design. Cementless and cemented twin-peg femoral components had similar fixation. A lower flexion angle was correlated with higher component migration.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Masculino , Humanos , Persona de Mediana Edad , Artroplastia de Reemplazo de Rodilla/métodos , Diseño de Prótesis , Osteoartritis de la Rodilla/cirugía , Radiografía , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Falla de Prótesis , Cementos para Huesos
14.
Pharm Res ; 39(7): 1633-1643, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35233728

RESUMEN

PURPOSE: Flucloxacillin is a ß-lactam penicillin commonly used in the treatment of bone and soft tissue infections. In a recent porcine study, we found surprisingly low time for which the free concentration was maintained above the minimal inhibitory concentration (fT>MIC) in bone and soft tissue, following flucloxacillin oral (PO) and intravenous (IV) administration at 1g every 6h (q6h). In addition to plasma, sampling was obtained from subcutaneous tissue, knee joint, cancellous bone and cortical bone, using microdialysis. To identify flucloxacillin dosing regimens that result in theoretically therapeutic concentrations, we developed a population pharmacokinetic (PK) model for the porcine data, and combined it with a human flucloxacillin population PK model for simulations. METHODS: A four-compartment model was developed, and various dosing regimens and modes of administration were simulated. Predicted concentrations were compared to %fT>MIC (0.5 mg/L and 2 mg/L). RESULTS: Continuous infusion (CI) resulted in higher %fT>MIC compared to intermittent administration. For intermittent IV dosing (4, 8 and 12g/24h), fT>MIC (0.5 mg/L) was ≥70% in plasma, and ranged between 42-96% in the sampled tissue in a typical individual. By applying CI, 4g/day was sufficient to achieve ≥98% fT>MIC (0.5 mg/L) in all sampled tissues. For MIC 2 mg/L, ≥50% fT>MIC was only achieved in plasma at CI 8 and 12g/24h and IV 3g q6h. CONCLUSIONS: To reach efficacious flucloxacillin bone and tissue concentrations, dose increment or continuous infusion needs to be considered.


Asunto(s)
Antibacterianos , Floxacilina , Animales , Infusiones Intravenosas , Pruebas de Sensibilidad Microbiana , Microdiálisis , Porcinos
15.
Clin Rehabil ; 36(6): 767-775, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35167386

RESUMEN

OBJECTIVE: To investigate if using a hip bandage is more effective than standard care in the prevention of total hip arthroplasty re-dislocation in patients with a previous total hip arthroplasty dislocation. DESIGN: randomized controlled trial. SETTING: Holstebro Regional Hospital and Viborg Regional Hospital. SUBJECTS: A total of 99 patients, 51 women, mean 70.7 (SD 9.9) years were enrolled in an un-blinded, clinical randomized controlled trial. INTERVENTIONS: Participants with at least one previous total hip arthroplasty dislocation were randomized to either wearing a bandage reducing flexion, adduction, and internal rotation of the hip (intervention group) or to standard care (control group). The participants were followed for 12 weeks. Main follow-up measures were as follows: number of re-dislocations (primary outcome), hip disability measured with the Oxford Hip Score (0-48, 48 best), quality of life measured with the 36-Item Short Form Survey (0-100, 100 best), satisfaction with treatment and serious adverse events. Statistical analyses followed the intention-to-treat principle. RESULTS: No significant group differences were observed for the primary outcome re-dislocations (9 versus 15, P = 0.143) or for disability (11.3 versus 14.4, P = 0.161), quality of life (57.7 versus 48.3, P = 0.050) or satisfaction with treatment (P = 0.562). There were 3 serious adverse events leading to total hip arthroplasty revision in the intervention group and 4 in the control group. CONCLUSION: We found that a hip bandage is not superior to standard care in the prevention of total hip arthroplasty re-dislocation in those with a previous total hip arthroplasty dislocation.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Vendajes , Femenino , Estudios de Seguimiento , Luxación de la Cadera/etiología , Luxación de la Cadera/prevención & control , Luxación de la Cadera/cirugía , Humanos , Masculino , Calidad de Vida , Estudios Retrospectivos
16.
Eur Spine J ; 31(6): 1508-1514, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35488132

RESUMEN

AIMS: Flucloxacillin is a frequently used antibiotic in the treatment of spondylodiscitis. We assessed steady-state concentrations and time above minimal inhibitory concentration (fT > MIC) of flucloxacillin in the intervertebral disc, vertebral cancellous bone, subcutaneous tissue and plasma, after intravenous and oral administration. METHODS: Sixteen pigs were randomized into two groups; Group Peroral (Group PO) and Group Intravenous (Group IV) received 1 g flucloxacillin every 6 h for 24 h orally or intravenously. Microdialysis was used for sampling in the compartments of interest. A flucloxacillin target of 50% fT > MIC was applied for three MIC targets: 0.125, 0.5 and 2.0 µg/mL. RESULTS: Intravenous administration resulted in significantly longer fT > MIC for all targets. Target attainment was only reached for the low target of 0.125 µg/mL in Group IV in vertebral cancellous bone, subcutaneous tissue, and plasma (intervertebral disc 47%). In Group IV, mean fT > MIC values in the investigated compartments were in the range of 47-67% of the dosing interval for 0.125 µg/mL, 20-35% for 0.5 µg/mL, and 0-15% for 2.0 µg/mL. In Group PO, mean fT > MIC values for 0.125 µg/mL were in the range of 1-33%. No pigs reached a concentration of 0.5 µg/mL in any of the investigated compartments in Group PO. CONCLUSION: Administration of 1 g flucloxacillin every 6 h resulted in surprisingly low steady-state fT > MIC after intravenous and oral administration. However, intravenous administration resulted in significantly higher concentrations across compartments compared to oral administration. Sufficient target tissue concentrations for treatment of spondylodiscitis may require a dose increase or alternative dosing regimens.


Asunto(s)
Discitis , Disco Intervertebral , Administración Intravenosa , Animales , Antibacterianos/farmacología , Hueso Esponjoso , Discitis/tratamiento farmacológico , Floxacilina , Humanos , Pruebas de Sensibilidad Microbiana , Microdiálisis/métodos , Porcinos
17.
Knee Surg Sports Traumatol Arthrosc ; 30(9): 3100-3113, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35099597

RESUMEN

PURPOSE: Cementless tibial components migrate initially until osseointegration and preserve periprosthetic bone. Cemented tibial components are fixed from surgery but loose periprosthetic bone. Little is known about bone formation and resorption biomarkers in relation to component fixation and bone mineral density (BMD) changes of cementless and cemented total knee arthroplasty. We hypothesize a similar migration of cemented and cementless tibial components between 1- and 2-year follow-up indicating a stable long-term fixation. METHODS: In a prospective patient-blinded randomized study, we compared cementless (n = 27) and cemented (n = 26) tibial components with radiostereometry measured migration (MTPM = Maximum Total Point Motion: point of component that migrates the most) and changes in BMD and biochemical bone turnover markers (BTMs) until 24 months after surgery. RESULTS: The mean MTPM between 12 and 24 months were similar between groups with - 0.06 mm (95% CI - 0.23; 0.11) in the cementless group compared to 0.02 mm (95% CI - 0.07; 0.11) in the cemented group. However, there was a higher proportion of cementless components (16/25) than cemented components (7/24) with continuous migration (MTPM > 0.2 mm) (p = 0.02). In the medial and anterior region below the tibial components, the BMD increased by mean 1.8% and 7.4% for cementless components and decreased by mean 8.6% and 4.2% for cemented components until 24-month follow-up. In both groups, BTMs initially showed increased bone resorption (CTx) and bone formation (P1NP) followed by normalization to pre-operative levels at 6 months post-surgery. CONCLUSION: More cementless components than cemented components showed continues migration which suggest a higher risk of early revision. Bone turnover increased post-surgery in both groups, but did not explain the difference in change in periprosthetic BMD. LEVEL OF EVIDENCE: I.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Cementos para Huesos , Densidad Ósea , Remodelación Ósea , Estudios de Seguimiento , Humanos , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis
18.
Acta Orthop ; 93: 375-381, 2022 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-35347340

RESUMEN

BACKGROUND AND PURPOSE: Dual-mobility hip arthroplasty utilizes a freely rotating polyethylene acetabular liner to protect against dislocation. As liner motion has not been confirmed in vivo, we undertook this using dynamic radiostereometry (RSA). PATIENTS AND METHODS: 6 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient-reported outcome measures were obtained postoperatively and at 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER-FADIR), to end-range and at 45° hip flexion. Liner and neck movements were described as anteversion, inclination, and rotation. RESULTS: Liner movement during modified FABER-FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5-20), inclination 6° (2-12), and rotation 11° (5-48) relative to the cup. Median absolute change in the resulting liner/neck angle (small articulation) was 28° (12-46) and in liner/cup angle (larger articulation) was 6° (4-21). Static RSA showed changes in median liner anteversion from 7° (-12 to 23) postoperatively to 10° (-3 to 16) at 1-year follow-up and inclination from 42° (35-66) postoperatively to 59° (46-80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p = 0.01). INTERPRETATION: The polyethylene liner moves over time. 1 year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Humanos , Polietileno , Análisis Radioestereométrico , Rango del Movimiento Articular
19.
Acta Orthop ; 93: 658-664, 2022 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-35848733

RESUMEN

BACKGROUND AND PURPOSE: BoneMaster (BM) is a thin electrochemically applied hydroxyapatite (HA) implant coating marketed with expectations of improved osseointegration properties but less polyethylene (PE) wear. We compared the midterm cup migration and PE wear of cementless porous-coated hemispherical cups with and without BM. PATIENTS AND METHODS: In this patient-blinded, randomized controlled trial, 53 patients with a mean age of 64 years (55-75) received total hip arthroplasty with a porous-coated (P) or porous and BoneMaster (PBM) coated Exceed cup and ArCom E1 infused PE. Patients were followed with RSA, Hip Osteoarthritis Outcome Score (HOOS), and Euro-Qol-5-3L (EQ-5D) at 3 and 6 months, and 1-, 2-, and 5-year follow-up. RESULTS: At 5-year follow-up, total translation and maximum total point motion was 0.28 mm (95% CI 0.08; 0.47) and 0.52 mm (CI 0.12; 0.93) higher in the PBM group than in the P group. PE wear was comparable between PBM and P cups, and 2D wear rate from 1-year follow-up to last follow-up was 0.03 mm (CI 0.02-0.03). The 5-year anterior translation was 0.05 mm (CI -0.10 to 0.21) in the normal BMD group and 0.40 mm (CI 0.22-0.57) in the osteopenia group. INTERPRETATION: At 5-year follow-up, Exceed cups in the PBM group migrated more than in the P group but the PE wear rate was low and similar. This study does not indicate any advantage of additional BoneMaster coating compared with porous coating alone on cementless hemispherical cups with regards to migration, polyethylene wear, and clinical outcomes.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Durapatita , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Polietileno , Porosidad , Diseño de Prótesis , Falla de Prótesis , Titanio
20.
Acta Orthop ; 93: 906-913, 2022 12 16.
Artículo en Inglés | MEDLINE | ID: mdl-36545926

RESUMEN

BACKGROUND AND PURPOSE: Dual mobility (DM) articulation total hip arthroplasty (THA) is used increasingly to reduce dislocation risk. We investigated cup fixation, polyethylene (PE) wear, serum chromium and cobalt ions, and their correlation to physical activity in patients with DM cups at 6-year follow-up. PATIENTS AND METHODS: In a patient-blinded RCT, 60 patients with hip osteoarthritis at a median age of 74 years (70-82) were randomly allocated to cemented (n = 30) or cementless hydroxyapatite-coated (n = 30) fixation of Avantage DM THA with a highly-crosslinked vitamin-E PE liner. Cup migration and PE wear were measured with radiostereometric analysis (RSA), chromium and cobalt ions were measured in serum, and physical activity was measured with accelerometers. RESULTS: At 6-year follow-up, proximal cup migration was similar: 0.14 mm (95% CI 0.01-0.28) for cemented cups and 0.21 mm (0.02-0.39) for cementless cups. The PE wear rate from 1- to 6-year follow-up was also similar: 0.06 mm/year (0.04-0.09) for cemented cups and 0.07 mm/year (0.04-0.11) for cementless cups. Serum metal ion levels were undetectable or very low. Physical activity was mainly low intensity and did not correlate to PE wear rate or cup migration. CONCLUSION: Cemented and cementless DM cups with highly crosslinked vitamin-E infused liners have similar cup migration and PE wear when used for primary THA surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Anciano , Anciano de 80 o más Años , Polietileno , Análisis Radioestereométrico , Estudios de Seguimiento , Cromo , Cobalto , Vitaminas , Diseño de Prótesis , Falla de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA