Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Diagnostics (Basel) ; 12(2)2022 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-35204593

RESUMEN

The European Colonoscopy Quality Investigation (ECQI) Group aims to raise awareness for improvement in colonoscopy standards across Europe. We analyzed data collected on a sample of procedures conducted across Europe to evaluate the achievement of the European Society of Gastrointestinal Endoscopy (ESGE) mean withdrawal time (WT) target. We also investigated factors associated with WT, in the hope of establishing areas that could lead to a quality improvement. METHODS: 6445 form completions from 12 countries between 2 June 2016 and 30 April 2018 were considered for this analysis. We performed an exploratory analysis looking at WT according to the ESGE definition. Stepwise multivariable logistic regression analysis was conducted to determine the most influential associated factors after adjusting for the other pre-specified variables. RESULTS: In 1150 qualifying colonoscopies, the mean WT was 7.8 min. Stepwise analysis, including 587 procedures where all inputs were known, found that the variables most associated with mean WT were a previous total colonoscopy in the last five years (p = 0.0011) and the time of day the colonoscopy was performed (p = 0.0192). The main factor associated with a WT < 6 min was the time of day that a colonoscopy was performed. Use of sedation was the main factor associated with a higher proportion of WT > 10 min, along with a previous colonoscopy. CONCLUSIONS: On average, the sample of European practice captured by the ECQI survey met the minimum standard set by the ESGE. However, there was variation and potential for improvement.

2.
Artículo en Inglés | MEDLINE | ID: mdl-35329077

RESUMEN

Background: The European Colonoscopy Quality Investigation (ECQI) Group aims to raise awareness for improvement in colonoscopy standards across Europe. We analysed data collected on a sample of procedures conducted across Europe to evaluate the achievement of the polyp detection rate (PDR) target. We also investigated factors associated with PDR, in the hope of establishing areas that could lead to a quality improvement. Methods: 6445 form completions from 12 countries between 2 June 2016 and 30 April 2018 were considered for this analysis. We performed an exploratory analysis looking at PDR according to European Society of Gastrointestinal Endoscopy (ESGE) definition. Stepwise multivariable logistic regression analysis was conducted to determine the most influential associated factors after adjusting for the other pre-specified variables. Results: In our sample there were 3365 screening and diagnostic procedures performed in those over 50 years. The PDR was 40.5%, which is comparable with the ESGE minimum standard of 40%. The variables found to be associated with PDR were in descending order: use of high-definition equipment, body mass index (BMI), patient gender, age group, and the reason for the procedure. Use of HD equipment was associated with a significant increase in the reporting of flat lesions (14.3% vs. 5.7%, p < 0.0001) and protruded lesions (34.7% vs. 25.4%, p < 0.0001). Conclusions: On average, the sample of European practice captured by the ECQI survey meets the minimum PDR standard set by the ESGE. Our findings support the ESGE recommendation for routine use of HD colonoscopy.


Asunto(s)
Pólipos del Colon , Neoplasias Colorrectales , Pólipos del Colon/diagnóstico , Colonoscopía , Neoplasias Colorrectales/patología , Endoscopía Gastrointestinal , Humanos , Tamizaje Masivo , Mejoramiento de la Calidad
3.
Endosc Int Open ; 9(10): E1456-E1462, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34540535

RESUMEN

Background and study aims The European Colonoscopy Quality Investigation (ECQI) Group comprises expert colonoscopists and investigators with the aim of raising colonoscopy standards. We assessed the levels of monitoring and achievement of European Society of Gastrointestinal Endoscopy (ESGE) performance measures (PMs) across Europe using responses to the ECQI questionnaires. Methods The questionnaire comprises three forms: institution and practitioner questionnaires are completed once; a procedure questionnaire is completed on multiple occasions for individual total colonoscopies. ESGE PMs were approximated as closely as possible from the data collected via the procedure questionnaire. Procedure data could provide rate of adequate bowel preparation, cecal intubation rate (CIR), withdrawal time, polyp detection rate (PDR), and tattooing resection sites. Results We evaluated ECQI questionnaire data collected between June 2016 and April 2018, comprising 91 practitioner and 52 institution questionnaires. A total of 6445 completed procedure forms were received. Institution and practitioner responses indicate that routine recording of PMs is not widespread: adenoma detection rate (ADR) is routinely recorded in 29 % of institutions and by 34 % of practitioners; PDR by 42 % and 47 %, CIR by 62 % and 64 %, bowel preparation quality by 56 % and 76 %, respectively. Procedure data showed a rate of adequate bowel preparation of 84.2 %, CIR 73.4 %, PDR 40.5 %, mean withdrawal time 7.8 minutes and 12.2 % of procedures with possible removal of a non-pedunculated lesion ≥ 20 mm reporting tattooing. Conclusions Our findings clearly show areas in need of quality improvement and the importance of promoting quality monitoring throughout the colonoscopy procedure.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA