J Endovasc Ther
; 22(4): 564-7, 2015 Aug.
Artículo
en Inglés
| MEDLINE
| ID: mdl-26045463
RESUMEN
PURPOSE: To present a novel method of preparing carbon dioxide (CO2) for contrast enhancement. TECHNIQUE: CO2 angiography can often produce poor image enhancement, especially in dependent vessels due to buoyancy of the gas. A new technique for premixing the CO2 gas with the patient's blood and dispersing it into the bubble mixture before injection was developed. Comparative dynamic images showed bubble-mixed CO2 angiography had less fragmentation, more even distribution, and more sustainability than the same volume of pure CO2. CONCLUSION: The alteration of CO2 gas toward a semiliquid form demonstrates an easy and reproducible concept to improve the dynamic image quality of traditional CO2 angiography.