Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Molecules ; 28(3)2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36771038

RESUMEN

Common methods for hold-up time and volume determination in Reversed-Phase Liquid Chromatography (RPLC) have been tested for Hydrophilic Interaction Liquid Chromatography (HILIC). A zwitterionic ZIC-HILIC column has been used for the testing. The pycnometric determination method, based on differences in column weight when filled with water or organic solvent, provides the overall volume of solvent inside the column. This includes the volume of eluent semi-sorbed on the packing of the column, which acts as the main stationary phase. The homologous series approach, based on the retention behavior of homologues in relation to their molecular volume, allows the determination of accurate hold-up volumes. However, the application of this method is time-consuming. In some cases, large neutral markers with poor dipolarity/polarizability and hydrogen bonding interactions can be used as hold-up volume markers. This is the case of dodecylbenzene and nonadecane-2-one in clearly HILIC behaving chromatographic systems, the use of decanophenone as a marker can be even extended to the boundary between HILIC and RPLC. The elution volume of the marker remains nearly unaffected by the concentration of ammonium acetate in the mobile phase up to 20 mM. The injection of pure solvents to produce minor base-line disturbance as hold-up markers is strongly discouraged, since solvent peaks are complex to interpret and depend on the ionic strength of the eluent.

2.
Mol Pharm ; 18(6): 2311-2321, 2021 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-33983741

RESUMEN

It is widely accepted that solubility-pH profiles of ionizable compounds follow the Henderson-Hasselbalch equation. However, several studies point out that compounds often undergo additional processes in saturated solutions, such as sub-micellar oligomerization, micellar aggregation, or drug-buffer complexation among others, which make the experimental profiles deviate from the behavior predicted by the Henderson-Hasselbalch equation. Often, the presence of additional processes is supported by the analysis of experimental data through solubility computer programs. However, the purpose of this work is to experimentally prove the aggregation phenomena for a series of bases for which deviations from the theoretical profile have been observed. To this end, five monoprotic bases (lidocaine, maprotiline, cyproheptadine, bupivacaine, and mifepristone) susceptible to form ionic aggregates in solution have been selected, and mass spectrometry has been the technique of choice to prove the presence of aggregation. High declustering potentials have been applied to prevent aggregates from forming in the ionization source of the mass spectrometer. In addition, haloperidol has been used as a negative control since according to its profile, it is not suspected to form ionic aggregates. In all instances, except for haloperidol, the analysis of the saturated solutions revealed the presence of mixed-charged dimers (aggregates formed by a neutral molecule and a charged one) and even trimers in the case of mifepristone and bupivacaine. For lidocaine, the most soluble of the compounds, the presence of neutral aggregates was also detected. These experiments support the hypothesis that the simple Henderson-Hasselbalch equation may explain the solubility-pH behavior of certain compounds, but it can be somewhat inaccurate in describing the behavior of many other substances.


Asunto(s)
Iones/química , Soluciones/química , Química Farmacéutica , Concentración de Iones de Hidrógeno , Solubilidad , Espectrometría de Masas en Tándem
3.
Electrophoresis ; 37(14): 2010-6, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27126602

RESUMEN

In the present work, several MEEKC systems are studied to assess their suitability for lipophilicity determination of acidic, neutral, and basic compounds. Thus, several microemulsion compositions over a wide range of pH values (from 2.0 to 12.0), containing heptane, 1-butanol and different types and amounts of surfactant (SDS or sodium cholate: from 1.3 to 3.3%) are characterized using Abraham's solvation model. The addition of acetonitrile (up to 10%) is also studied, since it increases the resolution of the technique for the most lipophilic compounds. The system coefficients obtained are very similar to those of the 1-octanol/water, used as the reference lipophilicity index, allowing simple and linear correlations between the 1-octanol/water partition values (log Po/w ) and MEEKC mass distribution ratios (log kMEEKC ). Variations in the microemulsion composition (aqueous buffer, surfactant, concentration of ACN) did not significantly affect the similarity of the MEEKC systems to log Po/w partition.


Asunto(s)
Cromatografía Capilar Electrocinética Micelar/métodos , Emulsiones , Concentración de Iones de Hidrógeno , Lípidos/química , Modelos Químicos
4.
PLoS Pathog ; 9(4): e1003270, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23592991

RESUMEN

Upon infection, many RNA viruses reorganize their capsid for release of the genome into the host cell cytosol for replication. Often, this process is triggered by receptor binding and/or by the acidic environment in endosomes. In the genus Enterovirus, which includes more than 150 human rhinovirus (HRV) serotypes causing the common cold, there is persuasive evidence that the viral RNA exits single-stranded through channels formed in the protein shell. We have determined the time-dependent emergence of the RNA ends from HRV2 on incubation of virions at 56°C using hybridization with specific oligonucleotides and detection by fluorescence correlation spectroscopy. We report that psoralen UV crosslinking prevents complete RNA release, allowing for identification of the sequences remaining inside the capsid. We also present the structure of uncoating intermediates in which parts of the RNA are condensed and take the form of a rod that is directed roughly towards a two-fold icosahedral axis, the presumed RNA exit point. Taken together, in contrast to schemes frequently depicted in textbooks and reviews, our findings demonstrate that exit of the RNA starts from the 3'-end. This suggests that packaging also occurs in an ordered manner resulting in the 3'-poly-(A) tail becoming located close to a position of pore formation during conversion of the virion into a subviral particle. This directional genome release may be common to many icosahedral non-enveloped single-stranded RNA viruses.


Asunto(s)
ARN Viral/genética , ARN Viral/metabolismo , Rhinovirus/fisiología , Internalización del Virus , Desencapsidación Viral , Secuencia de Bases , Cápside/química , Cápside/metabolismo , Reactivos de Enlaces Cruzados/farmacología , Ficusina/farmacología , Genoma Viral , Humanos , Conformación de Ácido Nucleico , Poli A/metabolismo , Conformación Proteica , Rhinovirus/genética , Análisis de Secuencia de ARN , Rayos Ultravioleta , Ensamble de Virus , Desencapsidación Viral/efectos de los fármacos , Desencapsidación Viral/genética
5.
J Chromatogr A ; 1713: 464529, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38029660

RESUMEN

A detailed analysis of intra-particle volumes and layer thicknesses and their effect on the diffusion of solutes in hydrophilic interaction liquid chromatography (HILIC) was made. Pycnometric measurements and the retention volume of deuterated mobile phase constituents (water and acetonitrile) were used to estimate the void volume inside the column, including not only the volume of the mobile phase but also part of the enriched water solvent acting as the stationary phase in HILIC. The mobile phase (hold-up) volume accessible to non-retained components was estimated using a homologous series approach. The joint analysis of the different approaches indicated the formation of enriched water layers on the hydrophobic silica mesopore walls with a thickness varying significantly with mobile phase composition. The maximal thickness of the enriched water layers, which corresponded to the minimum void volume accessible to unretained solutes, marked a transition in the retention behavior of the studied analytes. Discrepancies between deuterated solvent measurements and pycnometry were explained by the existence of an irreplaceable water layer adsorbed on the silica surface. Regarding the diffusion behavior in HILIC, peak parking experiments were used to interpret the influence of the acetonitrile content on the effective diffusion coefficient Deff. A systematic decrease in Deff and molecular diffusion Dm was observed with decreasing acetonitrile concentration, primarily attributed to variations in mobile phase viscosity. Notably, Deff/Dm remained nearly unaffected by variations in mobile phase composition. Finally, the effective medium theory was used to make a comprehensive analysis of Dpart/Dm to study the contribution to band broadening when the solute resides in the mesopores. The obtained data unveiled a curvature with a minimum corresponding to conditions of maximum water-layer thickness and retention. For the weakly retained compounds (k' < 0.5) the Dpart/Dm-values were found to be relatively high (order of 0.35-0.5), which directly reflects the high γsDs/Dm-values that were observed (order 0.35-7).


Asunto(s)
Dióxido de Silicio , Agua , Dióxido de Silicio/química , Cromatografía Liquida/métodos , Solventes , Interacciones Hidrofóbicas e Hidrofílicas , Acetonitrilos
6.
Electrophoresis ; 34(11): 1600-9, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23483563

RESUMEN

Human rhinoviruses (HRVs) are valuable tools in the investigation of early viral infection steps due to their far reaching (although still incomplete) characterization. During endocytosis, native virions first loose one of the four capsid proteins (VP4); corresponding particles sediment at 135S and were termed subviral A particles. Subsequently, the viral RNA genome leaves the viral shell giving rise to empty capsids. In continuation of our previous work with HRV serotype 2 (HRV2) intermediate subviral particles, in which we were able to discriminate by CE even between two intermediates (AI and AII) of virus uncoating, we further concentrated on the characterization of AI particles with the electrophoretic mobility of around -17.2 × 10(-9) m(2) /Vs at 20°C. In the course of our present work we related these particles to virions as previously described at the subviral A stage of uncoating (and as such sedimenting at 135S) by determination of their protein and RNA content--in comparison to native virions AI particles did not include VP4, however, still 93% of their initial RNA content. Binding of an mAb specific for subviral particles demonstrated antigenic rearrangements on the capsid surface at the AI stage. Furthermore, we investigated possible factors stabilizing intermediates of virus uncoating. We could exclude the influence of the previously suspected so-called contaminant of virus preparation on HRV2 subviral particle formation. Instead, we regarded other factors being part of the virus preparation system and found a dependence of AI particle formation on the presence of divalent cations.


Asunto(s)
Infecciones por Picornaviridae/virología , Rhinovirus/química , Virión/química , Anticuerpos Monoclonales/inmunología , Electroforesis Capilar , Humanos , Magnesio/química , Espectrometría de Masas , ARN Viral/análisis , Rhinovirus/inmunología , Virión/inmunología , Virión/aislamiento & purificación
7.
Anal Chim Acta ; 1277: 341672, 2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37604624

RESUMEN

The Abraham's solvation parameter model, based on linear solvation energy relationships (LSER), allows the accurate characterization of the selectivity of chromatographic systems according to solute-solvent interactions (polarizability, dipolarity, hydrogen bonding, and cavity formation). However, this method, based on multilinear regression analysis, requires the measurement of the retention factors of a considerably high number of compounds, turning it into a time-consuming low throughput method. Simpler methods such as Tanaka's scheme are preferred. In the present work, the Abraham's model is revisited to develop a fast and reliable method, similar to the one proposed by Tanaka, for the characterization of columns employed in reversed-phase liquid chromatography and particularly in hydrophilic interaction liquid chromatography. For this purpose, pairs of compounds are carefully selected in order to have in common all molecular descriptors except for a specific one (for instance, similar molecular volume, dipolarity, polarizability, and hydrogen bonding basicity features, but different hydrogen bonding acidity). Thus, the selectivity factor of a single pair of test compounds can provide information regarding the extent of the dissimilar solute-solvent interactions and their influence on chromatographic retention. The proposed characterization method includes the determination of the column hold-up volume and Abraham's cavity term by means of the injection of four alkyl ketone homologues. Therefore, five chromatographic runs in a reversed-phase column (four pairs of test solutes and a mixture of four homologues) are enough to characterize the selectivity of a chromatographic system. Tanaka's method is also analyzed from the LSER point of view.

8.
J Virol ; 85(16): 8368-75, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21680510

RESUMEN

After uptake into target cells, many nonenveloped viruses undergo conformational changes in the low-pH environment of the endocytic compartment. This results in exposure of amphipathic viral peptides and/or hydrophobic protein domains that are inserted into and either disrupt or perforate the vesicular membranes. The viral nucleic acids thereby gain access to the cytosol and initiate replication. We here demonstrate the in vitro transfer of the single-stranded positive-sense RNA genome of human rhinovirus 2 into liposomes decorated with recombinant very-low-density lipoprotein receptor fragments. Membrane-attached virions were exposed to pH 5.4, mimicking the in vivo pH environment of late endosomes. This triggered the release of the RNA whose arrival in the liposomal lumen was detected via in situ cDNA synthesis by encapsulated reverse transcriptase. Subsequently, cDNA was PCR amplified. At a low ratio between virions and lipids, RNA transfer was positively correlated with virus concentration. However, membranes became leaky at higher virus concentrations, which resulted in decreased cDNA synthesis. In accordance with earlier in vivo data, the RNA passes through the lipid membrane without causing gross damage to vesicles at physiologically relevant virus concentrations.


Asunto(s)
Membrana Celular/metabolismo , Liposomas , Infecciones por Virus ARN/virología , Rhinovirus/fisiología , Internalización del Virus , Desencapsidación Viral , Membrana Celular/virología , Genoma Viral , Concentración de Iones de Hidrógeno , Lípidos de la Membrana/metabolismo , Microscopía Electrónica de Transmisión , Nanoestructuras , ARN Viral/metabolismo , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa
9.
Electrophoresis ; 33(12): 1833-41, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22740471

RESUMEN

During infection, enteroviruses, such as human rhinoviruses (HRVs), convert from the native, infective form with a sedimentation coefficient of 150S to empty subviral particles sedimenting at 80S (B particles). B particles lack viral capsid protein 4 (VP4) and the single-stranded RNA genome. On the way to this end stage, a metastable intermediate particle is observed in the cell early after infection. This subviral A particle still contains the RNA but lacks VP4 and sediments at 135S. Native (150S) HRV serotype 2 (HRV2) as well as its empty (80S) capsid have been well characterized by capillary electrophoresis. In the present paper, we demonstrate separation of at least two forms of subviral A particles on the midway between native virions and empty 80S capsids by CE. For one of these intermediates, we established a reproducible way for its preparation and characterized this particle in terms of its electrophoretic mobility and its appearance in transmission electron microscopy (TEM). Furthermore, the conversion of this intermediate to 80S particles was investigated. Gas-phase electrophoretic mobility molecular analysis (GEMMA) yielded additional insights into sample composition. More data on particle characterization including its protein composition and RNA content (for unambiguous identification of the detected intermediate as subviral A particle) will be presented in the second part of the publication.


Asunto(s)
Electroforesis Capilar/métodos , Microscopía Electrónica/métodos , Rhinovirus/química , Espectrometría de Masa por Ionización de Electrospray/métodos , Virión/química , Células HeLa , Humanos , Concentración de Iones de Hidrógeno , Tamaño de la Partícula , Temperatura , Tiroglobulina/química
10.
Talanta ; 238(Pt 2): 123036, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-34801894

RESUMEN

The exceptional properties of 2D layered black phosphorus (BP) make it a promising candidate for electrochemical sensing applications and, even though BP is considered unstable and tends to degrade by the presence of oxygen and moisture, its oxidation can be beneficial in some situations. In this work, we present an unequivocal demonstration that the exposition of BP-based working electrodes to normal ambient conditions can indeed be advantageous, leading to an enhancement of voltammetric sensing applications. This point was proved using a BP modified screen-printed carbon electrode (BP-SPCE) for the voltammetric determination of dopamine (DA) as a model target analyte. Oxidized BP-SPCE (up to 35% of PxOy at the surface) presented an enhanced analytical performance with a 5-fold and 2-fold increase in sensitivity, as compared to bare-SPCE and non-oxidized BP-SPCE stored in anhydrous atmosphere, respectively. Good detection limit, repeatability, reproducibility, stability, selectivity, and accuracy were also achieved. Overall, the results presented herein display the prominent possibilities of preparing and working with BP based-sensors in normal ambient settings and showcase their implementation under physiological conditions.


Asunto(s)
Técnicas Electroquímicas , Fósforo , Carbono , Electrodos , Reproducibilidad de los Resultados
11.
Electrophoresis ; 32(13): 1579-90, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21647924

RESUMEN

In appropriate aqueous buffer solutions, biological particles usually exhibit a particular electric surface charge due to exposed charged or chargeable functional groups (amino acid residues, acidic carbohydrate moieties, etc.). Consequently, these bioparticles can migrate in solution under the influence of an electric field allowing separation according to their electrophoretic mobilities or their pI values. Based on these properties, electromigration methods are of eminent interest for the characterization, separation, and detection of such particles. The present review discusses the research papers published between 2008 and 2010 dealing with isoelectric focusing and zone electrophoresis of viruses, organelles and microorganisms (bacteria and yeast cells) in the capillary and the chip format.


Asunto(s)
Bacterias/aislamiento & purificación , Separación Celular/métodos , Electroforesis Capilar/métodos , Focalización Isoeléctrica/métodos , Virus/aislamiento & purificación , Electroforesis por Microchip , Orgánulos , Levaduras/aislamiento & purificación
12.
J Chromatogr A ; 1656: 462543, 2021 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-34571282

RESUMEN

Pycnometric and homologous series retention methods are used to determine the volume and mean composition of the water-rich layers partially adsorbed on the surface of several hydrophilic interaction liquid chromatography (HILIC) column fillings with acetonitrile-water and methanol-water as eluents. The findings obtained in this work confirm earlier studies using direct methods for measuring the stationary phase water content performed by Jandera's and Irgum's research groups. Water is preferentially adsorbed on the surface of the HILIC bonded phase in hydroorganic eluents containing more than 40% acetonitrile or 70% methanol, and a gradient of several water-rich transition layers between the polar bonded phase and the poorly polar bulk mobile phase is formed. These layers of reduced mobility act as HILIC stationary phases, retaining polar solutes. The volume of these layers and concentration of adsorbed water is much larger for acetonitrile-water than for methanol-water mobile phases. In hydroorganic eluents with less than 20-30% acetonitrile or 40% methanol the amount of preferentially adsorbed water is very small, and the observed retention behavior is close to the one in reversed-phase liquid chromatography (RPLC). In eluents with intermediate acetonitrile-water or methanol-water compositions a mixed HILIC-RPLC behavior is presented. Comparison of several HILIC columns shows that the highest water enrichment in the HILIC retention region for acetonitrile-water mobile phases is observed for zwitterionic and aminopropyl bonded phases, followed in minor grade for diol and polyvinyl alcohol functionalizations. Pentafluorophenyl bonded phase, usually considered a HILIC column, does not show significant water adsorption, nor HILIC retention.


Asunto(s)
Cromatografía de Fase Inversa , Agua , Adsorción , Cromatografía Liquida , Interacciones Hidrofóbicas e Hidrofílicas
13.
Anal Chem ; 82(19): 8146-52, 2010 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-20806784

RESUMEN

Permeabilization of model lipid membranes by virus-derived peptides, viral proteins, and entire virions of human rhinovirus was assessed by quantifying the release of a fluorescent dye from liposomes via a novel chip electrophoretic assay. Liposomal leakage readily occurred upon incubation with the pH-sensitive synthetic fusogenic peptide GALA and, less efficiently, with a 24mer peptide (P1-N) derived from the N-terminus of the capsid protein VP1 of human rhinovirus 2 (HRV2) at acidic pH. Negative stain transmission electron microscopy showed that liposomes incubated with the rhinovirus-derived peptide remained largely intact. At similar concentrations, the GALA peptide caused gross morphological changes of the liposomes. On a molar basis, the leakage-inducing efficiency of the P1 peptide was by about 2 orders of magnitude inferior to that of recombinant VP1 (from HRV89) and entire HRV2. This underscores the role in membrane destabilization of VP1 domains remote from the N-terminus and the arrangement of the peptide in the context of the icosahedral virion. Our method is rapid, requires tiny amounts of sample, and allows for the parallel determination of released and retained liposomal cargo.


Asunto(s)
Electroforesis/métodos , Liposomas/metabolismo , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos , Péptidos/metabolismo , Proteínas Virales/metabolismo , Virión/metabolismo , Secuencia de Aminoácidos , Colorantes Fluorescentes , Humanos , Microscopía Electrónica de Transmisión , Rhinovirus/metabolismo
14.
Anal Chim Acta ; 1130: 39-48, 2020 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-32892937

RESUMEN

A methodology for the estimation of the different phase volumes in HILIC is presented. For a ZIC-HILIC column the mobile phase volume (hold-up volume) is determined in several acetonitrile- and methanol-water compositions by a Linear Free Energy Relationships (LFER) homologous series approach involving n-alkyl-benzenes, -phenones, and -ketones. We demonstrate that the column works as a HILIC column when the mobile phase contains high and medium proportions of methanol or acetonitrile. However, for acetonitrile contents below 20%, or 40% for methanol, same column works in RPLC. In between, a mixed HILIC-RPLC behavior is observed, and solutes of low molecular volume are retained as in HILIC mode, but the largest ones show RPLC retention. From the homologous series retention data and pycnometric measurements involving the pure organic solvents and their mixtures with water, the mean solvent composition of the water-rich transition layers between column functionalization and the bulk mobile phase, which act as stationary phase, is estimated. Finally, the phase ratio between stationary and mobile phases is also estimated for each eluent composition, allowing the calculation of the corresponding stationary phase volumes. All volumes are strongly dependent on the water content in the eluent, especially when acetonitrile is selected as mobile phase constituent. In HILIC mode, when the water content in the hydroorganic mobile phase increases, the volumes of mobile phase decrease, but the volumes of stationary phase (mainly the water layer adsorbed onto the bonded-phase and the water-enriched interface) increase. However, at high water concentrations, where the column works in RPLC mode, the mobile phase volume increases and the stationary phase (which is now the bonded zwitterion) volume decreases when increasing the water percentage in the mobile phase.

15.
Eur J Pharm Sci ; 148: 105305, 2020 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-32184154

RESUMEN

The solubility of three drugs (glimepiride, pioglitazone, sibutramine) with different acid/base properties and expected supersaturation behavior was examined in detail using the shake-flask (SF) and potentiometric (CheqSol) methods. Both uncharged (free) species and hydrochloride salts were used as starting materials. On the one hand, the SF method provided information about the thermodynamic solubility at any pH value, including the counterion-dependent solubility of ionic species. Additionally, this method easily allowed the identification of the solid phase in equilibrated solutions by powder X-ray diffraction, and the detection and quantification of aggregation and complexation reactions. On the other hand, CheqSol method permitted the measurement of the equilibrium solubility of neutral species, the observation of changes in solid forms, and the extent and duration of supersaturation (kinetic solubility) for "chaser" compounds. The combined information from both methods gave an accurate picture of the solubility behavior of the studied drugs.


Asunto(s)
Preparaciones Farmacéuticas/química , Tecnología Farmacéutica/métodos , Ciclobutanos/química , Concentración de Iones de Hidrógeno/efectos de los fármacos , Pioglitazona/química , Potenciometría/métodos , Solubilidad , Compuestos de Sulfonilurea/química
16.
Anal Chim Acta ; 1092: 132-143, 2019 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-31708026

RESUMEN

The Abraham solvation parameter model, a linear free energy relationship (LFER) approach, has been used to characterize a polymeric zwitterionic (sulfobetaine) column in HILIC mode. When acetonitrile (MeCN) is used in the preparation of mobile phases the main solute characteristics affecting the chromatographic behavior of analytes are the molecular size and the hydrogen-bonding (both acidity and basicity) interactions. The former property is more favorable in the acetonitrile-rich mobile phase, reducing thus the retention, but the latter reveals a higher affinity for the water layer adsorbed on the stationary phase, enhancing retention. However, if the aprotic acetonitrile is replaced by methanol, a hydrogen-bond acidic solvent, solute hydrogen-bond basicity does not contribute any more to retention, quite the opposite. Thus, a slightly different selectivity is observed in methanol/water than in acetonitrile/water. Normal-phase mode and HILIC-MeCN share the same main factors affecting retention. For reversed-phase and immobilized artificial membrane (IAM) chromatography, the solute molecular size increase retention because of the lower amount of energy required in the formation of a cavity in the solvated stationary phase. On the contrary, the analyte hydrogen-bond basicity favors interactions with the hydroorganic mobile phase and reduces retention. The determined parameters justify the reversed selectivity commonly observed in HILIC in reference to reversed-phase. In most instances, the least retained solutes in reversed-phase are the most retained in HILIC.

17.
Anal Chim Acta ; 1050: 176-184, 2019 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-30661587

RESUMEN

The high proportion of acetonitrile used in many HILIC mobile phases significantly changes the acid-base properties of pH buffers and analytes foreseen from available data in water. In this paper, the recommended stability pH range for chromatographic columns is examined with various acetonitrile/water mixtures, resulting in a significant broadening in the operational pH window with the content of organic solvent. Additionally, the challenge of buffer selection in HILIC is also addressed. Commonly used ammonium acetate shrinks its pH buffering range in acetonitrile-rich mobile phases due to variations in the dissociation constants of the buffer constituents (acetic acid and ammonium). Thus, other organic acids such as formic acid, TFA, and succinimide have been studied as buffers in order to fully cover the pH range of use of the column. Also the retention-pH profiles of several acids and bases have been studied in 80% and 90% acetonitrile using the proposed buffers and their behavior compared to that obtained with buffers prepared from oxalic acid, pyrrolidine, and triethylamine. The latter two show additional interactions in 80% acetonitrile that distort the expected retention-pH profiles of acid analytes, but not the ones of bases. In 90% acetonitrile the profiles are affected by significant additional solute-buffer interactions that might be caused by ion pairing, homo- and heteroassociation in this low ion solvating medium.

18.
Talanta ; 201: 104-110, 2019 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-31122399

RESUMEN

A simple HPLC-EC method based on hydrophilic interaction liquid chromatography with amperometric detection through gold screen-printed electrodes has been developed and applied for the first time to the determination of aminothiols in white wines. Moreover, the coupling of the method with partial least squares discriminant analysis (PLS-DA) using the analysed aminothiols as biomarkers provides wine discrimination in terms of harvest year. White wine samples were directly injected and chromatographic areas, together with pH and redox potential values, allowed a successful discrimination of wines from different harvest years with a global classification rate of 97.8%. The developed HPLC-EC method also generated characteristic fingerprints that were combined with PLS-DA to classify wines according to three wine varieties, with a global classification rate of 95.3%.

19.
J Chromatogr A ; 1571: 176-184, 2018 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-30150116

RESUMEN

A homologous series approach derived from the Abraham's solvation model was developed for the determination of hold-up times. Firstly, it was tested from reversed-phase liquid chromatography data obtained in the literature involving several series of homologues, followed by its application in a polymeric zwitterionic HILIC column using two different homologous series (n-alkyl benzenes and n-alkyl phenones). Acetonitrile and methanol were selected as organic modifiers in a composition range between 80% and 100% in volume. Results obtained for both series were consistent, and hold-up times were found to be strongly dependent on the water content and the organic modifier nature of the mobile phase.


Asunto(s)
Derivados del Benceno/análisis , Cromatografía Líquida de Alta Presión/métodos , Cromatografía de Fase Inversa/métodos , Cetonas/análisis , Derivados del Benceno/química , Interacciones Hidrofóbicas e Hidrofílicas , Cetonas/química , Nitrosaminas/análisis , Nitrosaminas/química , Termodinámica
20.
Eur J Pharm Sci ; 122: 331-340, 2018 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-30006180

RESUMEN

In the present study three different procedures have been compared for the determination of the lipophilicity of the unionized species (log Po/w) of neutral, acidic, basic, amphoteric, and zwitterionic drugs. Shake-flask, potentiometric and chromatographic approaches have been assayed in a set of 66 representative compounds in different phases of advanced development. An excellent equivalence has been found between log Po/w values obtained by shake-flask and potentiometry, while the chromatographic approach is less accurate but very convenient for screening purposes when a high-throughput is required. In the case of zwitterionic and amphoteric compounds, either for shake-flask and chromatographic methods, the pH has to be accurately selected in order to ensure the compound to be in its neutral form.


Asunto(s)
1-Octanol/química , Preparaciones Farmacéuticas/química , Agua/química , Cromatografía Líquida de Alta Presión , Concentración de Iones de Hidrógeno , Potenciometría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA