RESUMEN
BACKGROUND: Real-time prediction of histologic features of small colorectal polyps may prevent resection and/or pathologic evaluation and therefore decrease colonoscopy costs. Previous studies showed that computer-aided diagnosis (CADx) was highly accurate, though it did not outperform expert endoscopists. OBJECTIVE: To assess the diagnostic performance of histologic predictions by general endoscopists before and after assistance from CADx in a real-life setting. DESIGN: Prospective, multicenter, single-group study. (ClinicalTrials.gov: NCT04437615). SETTING: 6 centers across the United States. PARTICIPANTS: 1252 consecutive patients undergoing colonoscopy and 49 general endoscopists with variable experience in real-time prediction of polyp histologic features. INTERVENTION: Real-time use of CADx during routine colonoscopy. MEASUREMENTS: The primary end points were the sensitivity and specificity of CADx-unassisted and CADx-assisted histologic predictions for adenomas measuring 5 mm or less. For clinical purposes, additional estimates according to location and confidence level were provided. RESULTS: The CADx device made a diagnosis for 2695 polyps measuring 5 mm or less (96%) in 1252 patients. There was no difference in sensitivity between the unassisted and assisted groups (90.7% vs. 90.8%; P = 0.52). Specificity was higher in the CADx-assisted group (59.5% vs. 64.7%; P < 0.001). Among all 2695 polyps measuring 5 mm or less, 88.2% and 86.1% (P < 0.001) in the CADx-assisted and unassisted groups, respectively, could be resected and discarded without pathologic evaluation. Among 743 rectosigmoid polyps measuring 5 mm or less, 49.5% and 47.9% (P < 0.001) in the CADx-assisted and unassisted groups, respectively, could be left in situ without resection. LIMITATION: Decision making based on CADx might differ outside a clinical trial. CONCLUSION: CADx assistance did not result in increased sensitivity of optical diagnosis. Despite a slight increase, the specificity of CADx-assisted diagnosis remained suboptimal. PRIMARY FUNDING SOURCE: Olympus America Corporation served as the clinical study sponsor.
Asunto(s)
Inteligencia Artificial , Pólipos del Colon , Colonoscopía , Diagnóstico por Computador , Sensibilidad y Especificidad , Humanos , Pólipos del Colon/patología , Estudios Prospectivos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Adenoma/patología , Adenoma/diagnóstico , Neoplasias Colorrectales/patología , Competencia Clínica , AdultoRESUMEN
This joint ASGE-ESGE guideline provides an evidence-based summary and recommendations regarding the role of endoscopic bariatric and metabolic therapies (EBMTs) in the management of obesity. The document was developed using the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) framework. It evaluates the efficacy and safety of EBMT devices and procedures that currently have CE mark or FDA-clearance/approval, or that had been approved within five years of document development. The guideline suggests the use of EBMTs plus lifestyle modification in patients with a BMI of ≥ 30 kg/m2, or with a BMI of 27.0-29.9 kg/m2 with at least 1 obesity-related comorbidity. Furthermore, it suggests the utilization of intragastric balloons and devices for endoscopic gastric remodeling (EGR) in conjunction with lifestyle modification for this patient population.
Asunto(s)
Cirugía Bariátrica , Endoscopía Gastrointestinal , Balón Gástrico , Obesidad , Humanos , Endoscopía Gastrointestinal/métodos , Obesidad/complicaciones , Adulto , Índice de Masa CorporalRESUMEN
This joint ASGE-ESGE guideline provides an evidence-based summary and recommendations regarding the role of endoscopic bariatric and metabolic therapies (EBMTs) in the management of obesity. The document was developed using the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) framework. It evaluates the efficacy and safety of EBMT devices and procedures that currently have CE mark or FDA-clearance/approval, or that had been approved within five years of document development. The guideline suggests the use of EBMTs plus lifestyle modification in patients with a BMI of ≥30âkg/m2, or with a BMI of 27.0-29.9âkg/m2 with at least 1 obesity-related comorbidity. Furthermore, it suggests the utilization of intragastric balloons and devices for endoscopic gastric remodeling (EGR) in conjunction with lifestyle modification for this patient population.
Asunto(s)
Cirugía Bariátrica , Endoscopía Gastrointestinal , Obesidad , Humanos , Cirugía Bariátrica/efectos adversos , Endoscopía Gastrointestinal/normas , Endoscopía Gastrointestinal/métodos , Obesidad/complicaciones , Adulto , Balón Gástrico/efectos adversosRESUMEN
BACKGROUND AND AIMS: The gas-filled intragastric balloon (IGB) system (Obalon) and the fluid-filled IGB system (Orbera) are the current FDA-approved IGB systems to treat obesity; however, they have not been previously compared in clinical practice. The aims of this study were to compare their efficacy, tolerance, and safety in a clinical setting. MATERIALS AND METHODS: This is a retrospective cohort study of consecutive patients treated with the gas-filled IGB or fluid-filled IGB between October 2015 and May 2020 at 2 academic centers. The primary endpoints included percent total body weight loss at balloon removal in patients who completed at least 20 weeks of therapy, the difference in adverse events that required urgent evaluation or hospitalization, and early removal in the 2 groups. RESULTS: A total of 87 patients underwent successful IGB placement (gas-filled IGB n=57, age 48.9±8.8, body mass index 35.5±5 kg/m 2 ; fluid-filled IGB n=30, age 49.2±14.3, body mass index 38.8±6 kg/m 2 ). Eleven patients underwent early device removal. There were no differences in percent total body weight loss at balloon removal and 12 months between the balloon systems ( P =0.39). Patients who received the fluid-filled IGB were more likely to require urgent evaluation or treatment, require hospital stay >24 hours, and need early balloon system removal compared with patients treated with the gas-filled IGB. CONCLUSION: In this 2-center cohort, both FDA-approved gastric balloon systems had the same effectiveness, but the gas-filled IGB had fewer serious adverse events and better tolerability than the fluid-filled IGB.
Asunto(s)
Balón Gástrico , Obesidad Mórbida , Humanos , Adulto , Persona de Mediana Edad , Balón Gástrico/efectos adversos , Estudios Retrospectivos , Pérdida de Peso , Obesidad/terapia , Tiempo de Internación , Obesidad Mórbida/cirugía , Resultado del TratamientoRESUMEN
Classically, Non-Alcoholic Fatty Liver Disease (NAFLD) has been thought to be driven by excessive weight gain and obesity. The overall greater awareness of this disorder has led to its recognition in patients with normal body mass index (BMI). Ongoing research has helped to better understand potential causes of Lean NAFLD, the risks for more advanced disease, and potential therapies. Here we review the recent literature on prevalence, risk factors, severity of disease, and potential therapeutic interventions.
Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Índice de Masa Corporal , Humanos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Enfermedad del Hígado Graso no Alcohólico/epidemiología , Obesidad/epidemiología , Prevalencia , Factores de RiesgoRESUMEN
A subcommittee of the Association for Bariatric Endoscopy, a division of the American Society for Gastrointestinal Endoscopy (ASGE) comprising experts in the subject area, performed this systematic review and meta-analysis. The systematic review and meta-analysis was reviewed by the ASGE Technology Committee and was ultimately submitted to the ASGE Governing Board for approval. The systematic review and meta-analysis underwent peer review by outside experts in statistics and meta-analysis before receiving final ASGE Governing Board approval. The Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) initiative is an ASGE program whose objectives are to identify important clinical questions related to endoscopy and to establish a priori diagnostic and/or therapeutic thresholds for endoscopic technologies designed to resolve these clinical questions. Once endoscopic technologies meet an established PIVI threshold, those technologies are appropriate to incorporate into clinical practice, presuming the appropriate training in that endoscopic technology has been achieved. ASGE encourages and supports the appropriate use of technologies that meet its established PIVI thresholds.
Asunto(s)
Bariatria , Endoscopía Gastrointestinal , Humanos , Estados UnidosRESUMEN
BACKGROUND AND AIMS: EUS remains a primary diagnostic tool for the evaluation of pancreaticobiliary disease. Although EUS combined with FNA or biopsy sampling is highly sensitive for the diagnosis of neoplasia within the pancreaticobiliary tract, limitations exist in specific clinical settings such as chronic pancreatitis. Enhanced EUS imaging technologies aim to aid in the detection and diagnosis of lesions that are commonly evaluated with EUS. METHODS: We reviewed technologies and methods for enhanced imaging during EUS and applications of these methods. Available data regarding efficacy, safety, and financial considerations are summarized. RESULTS: Enhanced EUS imaging methods include elastography and contrast-enhanced EUS (CE-EUS). Both technologies have been best studied in the setting of pancreatic mass lesions. Robust data indicate that neither technology has adequate specificity to serve as a stand-alone test for pancreatic malignancy. However, there may be a role for improving the targeting of sampling and in the evaluation of peritumoral lymph nodes, inflammatory pancreatic masses, and masses with nondiagnostic FNA or fine-needle biopsy sampling. Further, novel applications of these technologies have been reported in the evaluation of liver fibrosis, pancreatic cysts, and angiogenesis within neoplastic lesions. CONCLUSIONS: Elastography and CE-EUS may improve the real-time evaluation of intra- and extraluminal lesions as an adjunct to standard B-mode and Doppler imaging. They are not a replacement for EUS-guided tissue sampling but provide adjunctive diagnostic information in specific clinical situations. The optimal clinical use of these technologies continues to be a focus of ongoing research.
Asunto(s)
Quiste Pancreático , Neoplasias Pancreáticas , Pancreatitis Crónica , Biopsia con Aguja Fina , Endosonografía , Humanos , Neoplasias Pancreáticas/diagnóstico por imagen , Pancreatitis Crónica/diagnóstico por imagenRESUMEN
GOALS: The aim of this study was to evaluate the efficacy of tilt-down (TD) versus left lateral (LL) positioning in speed and ease of colonoscope insertion in women with risk factors for difficult colonoscopy. BACKGROUND: Risk factors for difficult colonoscopy in women include pelvic surgery, diverticulosis, and thin body habitus. STUDY: Female patients with body mass index (BMI) under 25, diverticulosis and history of pelvic surgery were randomized to TD or LL positioning. Five colonoscopists performed all studies at a single center. Time to splenic flexure and cecum, type and amount of medication administered, Boston Bowel Prep Score (BBPS), adverse events, and findings were recorded. The Mann-Whitney U test was used to evaluate the primary endpoint. RESULTS: A total of 150 women were enrolled (81 TD, 69 LL). The mean age was 60.1 (SD 10.5) and the mean BMI was 23.9 (SD 3.5). In total 98 (65.3%) women had prior pelvic surgery, 94 (62.7%) had BMI <25 and 60 (40.0%) had diverticulosis. There was no statistically significant difference in time to the splenic flexure overall but insertion to the splenic flexure was significantly faster in the TD position as compared with the LL position in patients with diverticulosis (124 s for TD, 160 s for LL, P=0.022). In a linear regression analysis, lower BMI, diverticulosis and lower BBPS were significantly associated with a longer insertion time to the splenic flexure. There were no adverse events. CONCLUSION: TD positioning represents a straightforward maneuver to facilitate advancement through the sigmoid colon and may be beneficial in women with diverticular disease.
Asunto(s)
Colonoscopios , Colonoscopía , Boston , Ciego , Femenino , Humanos , Persona de Mediana Edad , Posicionamiento del PacienteRESUMEN
BACKGROUND AND AIMS: Simulation refers to educational tools that allow for repetitive instruction in a nonpatient care environment that is risk-free. In GI endoscopy, simulators include ex vivo animal tissue models, live animal models, mechanical models, and virtual reality (VR) computer simulators. METHODS: After a structured search of the peer-reviewed medical literature, this document reviews commercially available GI endoscopy simulation systems and clinical outcomes of simulation in endoscopy. RESULTS: Mechanical simulators and VR simulators are frequently used early in training, whereas ex vivo and in vivo animal models are more commonly used for advanced endoscopy training. Multiple studies and systematic reviews show that simulation-based training appears to provide novice endoscopists with some advantage over untrained peers with regard to endpoints such as independent procedure completion and performance time, among others. Data also suggest that simulation training may accelerate the acquisition of specific technical skills in colonoscopy and upper endoscopy early in training. However, the available literature suggests that the benefits of simulator training appear to attenuate and cease after a finite period. Further studies are needed to determine if meeting competency metrics using simulation will predict actual clinical competency. CONCLUSIONS: Simulation training is a promising modality that may aid in endoscopic education. However, for widespread incorporation of simulators into gastroenterology training programs to occur, simulators must show a sustained advantage over traditional mentored teaching in a cost-effective manner. Because most studies evaluating simulation have focused on novice learners, the role of simulation training in helping practicing endoscopists gain proficiency using new techniques and devices should be further explored.
Asunto(s)
Endoscopía Gastrointestinal/educación , Gastroenterología/educación , Entrenamiento Simulado/métodos , Humanos , Modelos Anatómicos , Realidad VirtualRESUMEN
Non-alcoholic fatty liver disease (NAFLD) is the hepatic manifestation of metabolic syndrome; its rising prevalence parallels the rise in obesity and diabetes. Historically thought to result from overnutrition and a sedentary lifestyle, recent evidence suggests that diets high in sugar (from sucrose and/or high-fructose corn syrup [HFCS]) not only increase the risk of NAFLD, but also non-alcoholic steatohepatitis (NASH). Herein, we review the experimental and clinical evidence that fructose precipitates fat accumulation in the liver, due to both increased lipogenesis and impaired fat oxidation. Recent evidence suggests that the predisposition to fatty liver is linked to the metabolism of fructose by fructokinase C, which results in ATP consumption, nucleotide turnover and uric acid generation that mediate fat accumulation. Alterations to gut permeability, the microbiome, and associated endotoxemia contribute to the risk of NAFLD and NASH. Early clinical studies suggest that reducing sugary beverages and total fructose intake, especially from added sugars, may have a significant benefit on reducing hepatic fat accumulation. We suggest larger, more definitive trials to determine if lowering sugar/HFCS intake, and/or blocking uric acid generation, may help reduce NAFLD and its downstream complications of cirrhosis and chronic liver disease.
Asunto(s)
Fructosa/efectos adversos , Enfermedad del Hígado Graso no Alcohólico/etiología , Azúcares/efectos adversos , Animales , Bebidas/efectos adversos , Bebidas Gaseosas/efectos adversos , Ingestión de Alimentos , Fructoquinasas/metabolismo , Fructosa/administración & dosificación , Fructosa/metabolismo , Microbioma Gastrointestinal , Glucosa/metabolismo , Jarabe de Maíz Alto en Fructosa/efectos adversos , Humanos , Metabolismo de los Lípidos , Lipogénesis , Enfermedad del Hígado Graso no Alcohólico/metabolismo , Enfermedad del Hígado Graso no Alcohólico/prevención & control , Oxidación-Reducción , Factores de Riesgo , Azúcares/administración & dosificación , Azúcares/metabolismo , Ácido Úrico/metabolismoAsunto(s)
Enfermedad del Hígado Graso no Alcohólico , Vías Clínicas , Humanos , Hígado/patología , Cirrosis Hepática/patología , Enfermedad del Hígado Graso no Alcohólico/diagnóstico , Enfermedad del Hígado Graso no Alcohólico/epidemiología , Enfermedad del Hígado Graso no Alcohólico/terapia , Medición de Riesgo , Factores de RiesgoRESUMEN
Endoscopic bariatric and metabolic therapies (EBMT) are a new addition to the treatment arsenal for obesity. These include devices that are placed or removed via flexible endoscopy, and procedures that utilize instruments that require flexible endoscopy for the indications of weight loss or treatment of glucose intolerance (from pre-diabetes to diabetes). The EBMTs are generally divided into gastric and small bowel categories, and although individual EBMTs may have unique mechanisms of action, similar themes in proposed mechanism of action are seen in the gastric and small bowel EBMTs, respectively. In this review we will describe the therapies approved for use in the United States or currently in the process of obtaining approval for use in the United States. We will discuss potential mechanisms of action and examine safety and efficacy data.
Asunto(s)
Cirugía Bariátrica/instrumentación , Cirugía Bariátrica/métodos , Endoscopía Gastrointestinal , Obesidad/terapia , Técnicas de Ablación/instrumentación , Duodeno , Gastroplastia/métodos , Humanos , Mucosa Intestinal/cirugía , Succión , Técnicas de SuturaRESUMEN
BACKGROUND & AIMS: Reshape Duo is a saline-filled dual, integrated intragastric balloon (IGB) approved by the Food and Drug Administration for weight loss in patients with obesity. In a prospective, randomized trial, obese patients who received the balloon had significantly greater percent excess weight loss (%EWL) compared with patients treated with diet and exercise alone. However, there are limited data on the real-world efficacy of the Reshape balloon. METHODS: We performed a retrospective study of data collected from 2 academic centers and 5 private practices in which all patients paid for the IGB and follow-up visits out of pocket. The IGB was removed after 6 months. We collected data (demographic, medical, and laboratory) from 202 adults (mean age 47.8 ± 10.8 years; 83% female) with a baseline mean body mass index of 36.8 + 8.4 kg/m2 who had IGB insertion for weight loss therapy, along with counselling on lifestyle modifications focused on diet and exercise. Primary outcomes were percent total body weight loss (%TBWL) and %EWL at 1, 3, 6, 9, and 12 months after the procedure. RESULTS: Mean %TBWL at 1, 3, 6, 9 and 12 months was 4.8 ± 2.4%, 8.8 ± 4.3%, 11.4 ± 6.7%, 13.3 ± 7.8%, and 14.7 ± 11.8%, respectively. Data were available from 101 patients at 6 months and 12 patients at 12 months; 60.4% of patients achieved more than 10% TBWL and 55.4% had more than 25% EWL. Seventeen patients (8.4%) had esophageal tears during balloon insertion, with no intervention required. Thirteen patients (6.4%) had their IGB removed before the end of the 6-month treatment period. Nausea, vomiting, and abdominal pain were the most common adverse effects, occurring in 149 (73.8%), 99 (49%), and 51 (25.2%) patients. In one patient, the IGB migrated distally leading to small intestinal obstruction requiring surgical removal. CONCLUSION: In a retrospective analysis of real-world patients who received the Reshape Duo IGB, we found it to be a safe and efficacious endoscopic method for producing weight loss, with most patients achieving greater than 10% TBWL at 6 months.
Asunto(s)
Bariatria/efectos adversos , Bariatria/métodos , Balón Gástrico/efectos adversos , Obesidad/terapia , Pérdida de Peso , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
BACKGROUND AND AIMS: Remimazolam is an ultrashort-acting benzodiazepine. METHODS: We performed a randomized double-blind comparison of remimazolam to placebo for outpatient colonoscopy. This study design was a requirement of the U.S. Food and Drug Administration. An additional group was randomized to open-label midazolam administered according to its package insert instructions (the randomization ratio for remimazolam:placebo:midazolam was 30:6:10). Study medications were administered under the supervision of the endoscopist, without any involvement of an anesthesia specialist. Patients were given 50 to 75 µg of fentanyl before receiving study medications. Patients who failed to achieve adequate sedation in any arm were rescued with midazolam dosed at the investigator's discretion. The primary endpoint was a composite that required 3 criteria be met: completion of the colonoscopy, no need for rescue medication, and ≤5 doses of remimazolam or placebo in any 15-minute interval (≤3 doses of midazolam in any 12-minute interval in the open-label midazolam arm). RESULTS: There were 461 randomized patients in 12 U.S. sites. The primary endpoint was met for remimazolam, placebo, and midazolam in 91.3%, 1.7%, and 25.2% of patients, respectively (P < .0001 for remimazolam vs placebo). Patients administered remimazolam received less fentanyl, had faster recovery of neuropsychiatric function, were ready for discharge earlier, and felt back to normal sooner than patients with both placebo and midazolam. Hypotension was less frequent with remimazolam, and hypoxia occurred in 1% of patients with remimazolam or midazolam. There were no treatment-emergent serious adverse events. CONCLUSION: Remimazolam can be administered safely under the supervision of endoscopists for outpatient colonoscopy, and it allows faster recovery of neuropsychiatric function compared with placebo (midazolam rescue) and midazolam. (Clinical trial registration number: NCT02290873.).
Asunto(s)
Benzodiazepinas/uso terapéutico , Colonoscopía , Hipnóticos y Sedantes/uso terapéutico , Midazolam/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Ambulatorios , Método Doble Ciego , Femenino , Fentanilo , Humanos , Masculino , Persona de Mediana Edad , Adulto JovenRESUMEN
[This corrects the article on p. 258 in vol. 30, PMID: 29151716.].
RESUMEN
OBJECTIVES: The AspireAssist System (AspireAssist) is an endoscopic weight loss device that is comprised of an endoscopically placed percutaneous gastrostomy tube and an external device to facilitate drainage of about 30% of the calories consumed in a meal, in conjunction with lifestyle (diet and exercise) counseling. METHODS: In this 52-week clinical trial, 207 participants with a body-mass index (BMI) of 35.0-55.0 kg/m2 were randomly assigned in a 2:1 ratio to treatment with AspireAssist plus Lifestyle Counseling (n=137; mean BMI was 42.2±5.1 kg/m2) or Lifestyle Counseling alone (n=70; mean BMI was 40.9±3.9 kg/m2). The co-primary end points were mean percent excess weight loss and the proportion of participants who achieved at least a 25% excess weight loss. RESULTS: At 52 weeks, participants in the AspireAssist group, on a modified intent-to-treat basis, had lost a mean (±s.d.) of 31.5±26.7% of their excess body weight (12.1±9.6% total body weight), whereas those in the Lifestyle Counseling group had lost a mean of 9.8±15.5% of their excess body weight (3.5±6.0% total body weight) (P<0.001). A total of 58.6% of participants in the AspireAssist group and 15.3% of participants in the Lifestyle Counseling group lost at least 25% of their excess body weight (P<0.001). The most frequently reported adverse events were abdominal pain and discomfort in the perioperative period and peristomal granulation tissue and peristomal irritation in the postoperative period. Serious adverse events were reported in 3.6% of participants in the AspireAssist group. CONCLUSIONS: The AspireAssist System was associated with greater weight loss than Lifestyle Counseling alone.
Asunto(s)
Dolor Abdominal/epidemiología , Dietoterapia , Drenaje/métodos , Terapia por Ejercicio , Gastrostomía/métodos , Obesidad/terapia , Complicaciones Posoperatorias/epidemiología , Adulto , Femenino , Tejido de Granulación , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Pérdida de PesoRESUMEN
PURPOSE OF REVIEW: This review aims to present the current state of the field, highlight recent developments, and describe the clinical outcomes of these endoscopic bariatric and metabolic procedures. RECENT FINDINGS: There are an increasing number of devices and techniques that are available for the endoluminal treatment of obesity. It is now possible to offer FDA approved endoscopic therapies for patients with BMI as high as 55âkg/m. Although tremendous advances have been made, there is room for additional emphasis with regards to the metabolic improvements seen with these therapies, in addition to highlighting weight loss outcomes. Furthermore, for optimal outcomes, it is imperative that all endoluminal techniques are combined with at least a moderate intensity diet and lifestyle intervention for a minimum of 12 months. SUMMARY: This field bridges a gap between lifestyle counseling with or without pharmaceutical treatment and the most effective treatment of obesity, bariatric surgery. Owing to its minimally invasive nature, endoscopic metabolic and bariatric therapy has the potential to appeal patients who either do not qualify or do not want bariatric surgery and have not been adequately treated with medical therapy. In addition, these therapies may be beneficial early on in the onset of obesity.
Asunto(s)
Cirugía Bariátrica/tendencias , Endoscopía/tendencias , Obesidad Mórbida/cirugía , Cuidados Posoperatorios/métodos , Cirugía Bariátrica/métodos , Índice de Masa Corporal , Comorbilidad , Endoscopía/métodos , Humanos , Monitoreo Fisiológico , Medición de Riesgo , Resultado del Tratamiento , Pérdida de Peso/fisiologíaRESUMEN
IN BRIEF Several new endoscopic bariatric therapies have been approved by the U.S. Food and Drug Administration for the treatment of obesity, with many more devices and procedures undergoing investigational studies. This article describes these devices and procedures and special considerations for their use in patients with diabetes.