Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Med Imaging ; 24(1): 200, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39090553

RESUMEN

The objective of this study was to evaluate the intramammary distribution of MRI-detected mass and focus lesions that were difficult to identify with conventional B-mode ultrasound (US) alone. Consecutive patients with lesions detected with MRI but not second-look conventional B-mode US were enrolled between May 2015 and June 2023. Following an additional supine MRI examination, we performed third-look US using real-time virtual sonography (RVS), an MRI/US image fusion technique. We divided the distribution of MRI-detected mammary gland lesions as follows: center of the mammary gland versus other (superficial fascia, deep fascia, and atrophic mammary gland). We were able to detect 27 (84%) of 32 MRI-detected lesions using third-look US with RVS. Of these 27 lesions, 5 (19%) were in the center of the mammary gland and 22 (81%) were located in other areas. We were able to biopsy all 27 lesions; 8 (30%) were malignant and 19 (70%) were benign. Histopathologically, three malignant lesions were invasive ductal carcinoma (IDC; luminal A), one was IDC (luminal B), and four were ductal carcinoma in situ (low-grade). Malignant lesions were found in all areas. During this study period, 132 MRI-detected lesions were identified and 43 (33%) were located in the center of the mammary gland and 87 (64%) were in other areas. Also, we were able to detect 105 of 137 MRI-detected lesions by second-look conventional-B mode US and 38 (36%) were located in the center of the mammary gland and 67 (64%) were in other areas. In this study, 81% of the lesions identified using third-look US with RVS and 64% lesions detected by second-look conventional-B mode US were located outside the center of the mammary gland. We consider that adequate attention should be paid to the whole mammary gland when we perform third-look US using MRI/US fusion technique.


Asunto(s)
Neoplasias de la Mama , Imagen por Resonancia Magnética , Ultrasonografía Mamaria , Humanos , Femenino , Imagen por Resonancia Magnética/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Persona de Mediana Edad , Adulto , Ultrasonografía Mamaria/métodos , Anciano , Imagen Multimodal/métodos , Mama/diagnóstico por imagen , Carcinoma Ductal de Mama/diagnóstico por imagen , Carcinoma Ductal de Mama/patología
2.
BMC Med Imaging ; 23(1): 2, 2023 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-36604648

RESUMEN

BACKGROUND: The purpose of this study was to evaluate the clinical performance of Digital Breast Tomosynthesis guided vacuum-assisted biopsy (DBT-VAB) for microcalcifications in the breast. METHODS: Retrospective review of 131 mammography-guided VABs at our institution were performed. All of the targets were calcification lesion suspicious for cancer. 45 consecutive stereotactic vacuum-assisted biopsies (ST-VABs) and 86 consecutive DBT-VABs were compared. Written informed consent was obtained. Tissue sampling methods and materials were the same with both systems. Student's t-test was used to compare procedure time and the Fisher's exact test was used to compare success rate, complications, and histopathologic findings for the 2 methods. RESULTS: The tissue sampling success rate was 95.6% for ST-VAB (43/45) and 97.7% (84/86) for DBT-VAB. Time for positioning (10.6 ± 6.4 vs. 6.7 ± 5.3 min), time for biopsy (33.4 ± 13.1 vs. 22.5 ± 13.1 min), and overall procedure time (66.6 ± 16.6 min vs. 54.5 ± 13.0 min) were substantially shorter with DBT-VAB (P < 0.0001). There were no differences in the distribution of pathological findings between the 2 groups. CONCLUSION: Depth information and stable visibility of the target provided by DBT images led to quick decisions about target coordinates and improved the clinical performance of microcalcification biopsies.


Asunto(s)
Neoplasias de la Mama , Calcinosis , Humanos , Femenino , Japón , Mamografía/métodos , Mama/diagnóstico por imagen , Mama/patología , Biopsia con Aguja , Biopsia Guiada por Imagen/métodos , Biopsia , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Estudios Retrospectivos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología
3.
Ann Vasc Surg ; 84: 201-210, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35108556

RESUMEN

PURPOSE: Distal stent graft-induced new entry (SINE) is a serious complication of thoracic endovascular aortic repair (TEVAR) for Stanford type B aortic dissection (TBAD). The PETTICOAT-snowshoe technique was developed to prevent distal SINE for double-barrel TBAD. Initially, a proximal stent-graft (SG) is deployed, followed by the extension of a bare stent above the celiac artery and deployment of a second SG within the bare stent. This study examined whether the PETTICOAT-snowshoe technique prevents distal SINE. MATERIALS AND METHODS: This was a single-center, retrospective study comparing 2 groups that underwent conventional standard TEVAR between January 2013 and September 2018 and TEVAR using the PETTICOAT-snowshoe technique after October 2018 for double-barrel TBAD. RESULTS: Twenty-seven patients (74% male) underwent standard TEVAR (group A), while another 27 (78% male) underwent the PETTICOAT-snowshoe technique (group B). TEVAR was performed in the chronic phase on 15 patients (55.6%) in group A and on 16 (59.2%) in group B. Aorta-related mortality occurred in 1 patient in group A (3.7%). Oversizing ratios at the distal edge of the SG diameter to the major axis of the true lumen were 25% ± 26% and 25% ± 21% in groups A and B, respectively. During the follow-up period, 5 patients (18.5%) in group A and none in group B (P = 0.02) developed distal SINE. 3 of 5 patients with distal SINE in group A were treated with additional TEVAR, one with thoracoabdominal aortic replacement, and one with conservative observation. The freedom from distal SINE rate was significantly higher in group B than in group A (P = 0.04). CONCLUSIONS: The PETTICOAT-snowshoe technique significantly prevented distal SINE during the mid-term period even with the same distal SG oversizing as conventional standard TEVAR.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/etiología , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular/efectos adversos , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo , Stents/efectos adversos , Resultado del Tratamiento
4.
Minim Invasive Ther Allied Technol ; 31(1): 80-83, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32498635

RESUMEN

Hemorrhage arising from the coronary sinus is very rare and can be lethal. It has historically been treated surgically. The present patient had coronary sinus rupture secondary to esophageal cancer and an abscess in the pericardium. Due to her poor general status, this patient was contraindicated for surgery and underwent endovascular therapy. The hemorrhage was treated by stent graft deployment and the patient was temporarily discharged. Two months later, CT showed that the stent graft was occluded by thrombosis. The patient died without hemorrhage 2.5 months thereafter.


Asunto(s)
Implantación de Prótesis Vascular , Seno Coronario , Neoplasias Esofágicas , Neoplasias Esofágicas/complicaciones , Neoplasias Esofágicas/cirugía , Femenino , Hemorragia , Humanos , Stents , Resultado del Tratamiento
5.
Jpn J Clin Oncol ; 51(8): 1253-1260, 2021 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-34128053

RESUMEN

OBJECTIVE: We aimed to report the 2-year results of stereotactic body radiation therapy for prostate cancer and identify the clinical and dosimetric factors that predict acute genitourinary toxicities. METHODS: We retrospectively reviewed the medical records of patients with non-metastatic prostate cancer treated at Toyota Memorial Hospital between 2017 and 2020. The patients were treated with stereotactic body radiation therapy with a total dose of 36.25 Gy in five fractions on consecutive weekdays. While low-risk patients received radiotherapy alone, intermediate- to high-risk patients also received androgen deprivation therapy. RESULTS: We analysed a total of 104 patients, including 10, 60 and 34 low-, intermediate- and high-risk patients, respectively. The median follow-up duration was 2 years. We did not observe biochemical/clinical recurrence, distant metastasis or death from prostate cancer. One patient died of another cause. Grade 2 acute genitourinary toxicity was observed in 40 (38%) patients. Age (P = 0.021), genitourinary toxicity of grade ≥1 at baseline (P = 0.023) and bladder mean dose (P = 0.047) were significantly associated with the incidence of grade 2 acute genitourinary toxicity. The cut-off value of 65 years for age and 10.3 Gy for the bladder mean dose were considered the most appropriate. Grade 2 acute gastrointestinal toxicity was observed in five (5%) patients. None of the patients experienced grade ≥3 acute or late toxicity. CONCLUSIONS: Stereotactic body radiation therapy is feasible for Japanese patients with prostate cancer, with acceptable acute toxicity. Age, genitourinary toxicity at baseline and bladder mean dose predict grade 2 acute genitourinary toxicity.


Asunto(s)
Enfermedades Urogenitales Masculinas , Neoplasias de la Próstata , Traumatismos por Radiación , Radiocirugia , Anciano , Humanos , Japón/epidemiología , Masculino , Enfermedades Urogenitales Masculinas/etiología , Persona de Mediana Edad , Neoplasias de la Próstata/radioterapia , Traumatismos por Radiación/etiología , Radioterapia de Intensidad Modulada , Estudios Retrospectivos , Resultado del Tratamiento , Sistema Urogenital/efectos de la radiación
6.
BMC Cancer ; 20(1): 540, 2020 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-32517673

RESUMEN

BACKGROUND: Abdominal/pelvic lymph node (LN) oligometastasis, a pattern of treatment failure, is observed occasionally, and radiotherapy may work as salvage therapy. The optimal prescription dose, however, is yet to be determined. This study assessed the efficacy of high-dose radiotherapy. METHODS: The medical records of 113 patients at 4 institutes were retrospectively analysed who had 1 to 5 abdominal/pelvic LN oligometastases and were treated with definitive radiotherapy between 2008 and 2018. The exclusion criteria included non-epithelial tumours, uncontrolled primary lesions, palliative intent, and re-irradiation. The prescription dose was evaluated by using the equivalent dose in 2 Gy fractions (EQD2). Patients receiving EQD2 ≥ 60 Gy were placed into the high-dose group, and the remaining others the low-dose group. Kaplan-Meier analyses were performed to evaluate overall survival (OS), local control (LC), and progression-free survival (PFS). Univariate log-rank and multivariate Cox proportional hazards model analyses were performed to explore predictive factors. Adverse events were compared between the high-dose and low-dose groups. RESULTS: The primary tumour sites included the colorectum (n = 28), uterine cervix (n = 27), endometrium (n = 15), and ovaries (n = 10). The rate of 2-year OS was 63.1%, that of LC 59.7%, and that of PFS 19.4%. On multivariate analyses, OS were significantly associated with solitary oligometastasis (hazard ratio [HR]: 0.48, p = 0.02), LC with high-dose radiotherapy (HR: 0.93, p < 0.001), and PFS with long disease-free interval (HR: 0.59, p = 0.01). Whereas high-dose radiotherapy did not significantly improve 2-year OS in the entire cohort (74.8% in the high-dose vs. 52.7% in the low-dose; p = 0.08), it did in the subgroup of solitary oligometastasis (88.8% in the high-dose vs. 56.3% in the low-dose; p = 0.009). As for Late grade ≥ 3 adverse event, ileus was observed in 7 patients (6%) and gastrointestinal bleeding in 4 (4%). No significant association between the irradiation dose and adverse event incidence was found. CONCLUSIONS: As salvage therapy, high-dose radiotherapy was recommendable for oligometastasis in the abdominal/pelvic LNs. For solitary oligometastasis, LC and OS were significantly better in the high-dose group.


Asunto(s)
Metástasis Linfática/radioterapia , Terapia Recuperativa/métodos , Abdomen , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias Colorrectales/patología , Neoplasias Endometriales/patología , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Neoplasias Ováricas/patología , Pelvis , Supervivencia sin Progresión , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Radiocirugia/instrumentación , Radiocirugia/métodos , Radiocirugia/mortalidad , Dosificación Radioterapéutica , Estudios Retrospectivos , Terapia Recuperativa/efectos adversos , Terapia Recuperativa/mortalidad , Resultado del Tratamiento , Neoplasias del Cuello Uterino/patología , Adulto Joven
8.
Nagoya J Med Sci ; 78(2): 175-81, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27303104

RESUMEN

The purpose of this study was to investigate the feasibility of contrast-enhanced magnetic resonance (MR) pancreatography with intravenously administered gadolinium-based contrast material (GBCM) in healthy subjects. Eight healthy male subjects (age: 29-53 years old, median: 37 years old) were enrolled. Contrast-enhanced MR pancreatography was scanned with heavily T2-weighted three-dimensional fluid-attenuated inversion recovery (hT2W-3D-FLAIR) before and after intravenous GBCM administration. Two radiologists evaluated the images, referring to three-dimensional MR pancreatography by consensus. Scanning was performed five times at 1.5-h intervals (at 0.5, 2, 3.5, 5, and 6.5 h) after GBCM administration. In all subjects, pre-contrast-enhanced hT2W-3D-FLAIR images demonstrated no visualization of the main pancreatic duct. After GBCM administration, the main pancreatic duct was visualized in all subjects at 0.5 h (n=4, 50%) and/or 2 h (n=7, 88%). The mean signal intensity of the main pancreatic duct was 3.17 ± 0.78 at pre-contrast enhancement, 7.96 ± 4.60 at 0.5 h, and 8.08 ± 4.64 at 2 h. The signal intensity ratio of the main pancreatic duct against the pancreatic parenchyma was statistically higher (P < 0.01) at the 0.5-h and 2-h scans than that of pre-contrast-enhanced scan. Intravenously administered GBCM seeped into the pancreatic duct in sufficient concentration to alter the appearance of the main pancreatic duct by hT2W-3D-FLAIR in healthy subjects.


Asunto(s)
Imagen por Resonancia Magnética , Adulto , Medios de Contraste , Gadolinio , Voluntarios Sanos , Compuestos Heterocíclicos , Humanos , Masculino , Persona de Mediana Edad , Compuestos Organometálicos
9.
Nagoya J Med Sci ; 78(4): 437-446, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28008199

RESUMEN

Cardiac sarcoidosis (CS) can cause sudden death, which is the leading cause of mortality in patients with sarcoidosis in Japan. However, it is difficult to diagnose CS because of the lack of a sensitive diagnostic method for the condition. Late gadolinium-enhanced cardiac magnetic resonance (MR) imaging demonstrates improved sensitivity for diagnosing CS. Therefore, it is important to know the late gadolinium-enhancement (LGE) characteristics of CS on cardiac MR images in order to diagnose CS accurately. In this study, we investigated the most common sites of LGE on cardiac MR images in CS. Late gadolinium-enhanced MR images of 9 consecutive patients with CS (obtained between August 2009 and July 2015) were reviewed by two radiologists. The distribution of LGE was evaluated using the American Heart Association 17-segment model of the left ventricle. The LGE in each segment was also classified into 4 patterns according to the myocardial layer in which it occurred (the subepicardial, subendocardial, intramural, and transmural layer patterns). All 9 patients exhibited LGE in their left ventricle, and 70 of 153 (46%) myocardial segments were enhanced. All of the patients displayed LGE in the basal septal wall. The patients' LGE layer patterns were as follows: subepicardial: 40% (28/70), intramural: 30% (21/70), subendocardial: 16% (11/70), and transmural: 14% (10/70). The basal septum wall and subepicardial layer often exhibit LGE on cardiac MR images in CS patients. LGE can be observed in other segments and layers in some cases.

10.
Eur Radiol ; 25(5): 1366-74, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25433412

RESUMEN

OBJECTIVES: To evaluate the utility of multiphase contrast-enhanced computed tomography (CT) findings alone and in combination for differentiating focal-type autoimmune pancreatitis (f-AIP) from pancreatic carcinoma (PC). METHODS: The study group comprised 22 f-AIP lesions and 61 PC lesions. Two radiologists independently evaluated CT findings. Frequencies of findings were compared between f-AIP and PC. Statistical, univariate and multivariate analyses were performed. RESULTS: Homogeneous enhancement during the portal phase (AIP, 59 % vs. PC, 3 %; P < 0.001), dotted enhancement during the pancreatic phase (50 % vs. 7 %; P < 0.001), duct-penetrating sign (46 % vs. 2 %; P < 0.001), enhanced duct sign (36 % vs. 2 %; P < 0.001) and capsule-like rim (46 % vs. 3 %; P < 0.001) were more frequently observed in AIP. Ring-like enhancement during the delayed phase (5 % vs. 46 %; P < 0.001) and peripancreatic strands with a length of at least 10 mm (5 % vs. 39 %; P = 0.001) were more frequently observed in PC. AIP was identified with 82 % sensitivity and 98 % specificity using four of these seven findings. Multivariate analysis revealed significant differences in dotted enhancement (P = 0.004), duct-penetrating sign (P < 0.001) and capsule-like rim (P = 0.007). CONCLUSIONS: The combination of CT findings may allow improvements in differentiating f-AIP from PC. KEY POINTS: • f-AIP can mimic PC on imaging findings. • The differentiation of f-AIP from PC is important in patient management. • Some CT findings can be used to identify AIP. • The combination of CT findings will improve differentiation from PC.


Asunto(s)
Medios de Contraste , Neoplasias Pancreáticas/diagnóstico por imagen , Pancreatitis/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades Autoinmunes/diagnóstico , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Páncreas/diagnóstico por imagen , Estudios Retrospectivos , Sensibilidad y Especificidad , Neoplasias Pancreáticas
12.
Cureus ; 16(4): e57580, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38707120

RESUMEN

Introduction In stereotactic radiosurgery (SRS) for brain metastasis (BM), the prescribed dose is generally reported as a minimum dose to cover a specific percentage (e.g. D98%) of the gross tumor volume (GTV) with or without a margin or an unspecified intended marginal dose to the GTV boundary. In dose prescription to a margin-added planning target volume (PTV), the GTV marginal dose is likely variable and unclear. This study aimed to reveal major flaws of dose prescription to a fixed % coverage of a target volume (TV), such as GTV D98% or PTV D95%, and to propose an alternative. Materials and methods Seven quasi-spherical models with volumes ranging from 1.00 to 15.00 cc were assumed as GTVs. The GTVs and the volumes generated by adding isotropic 1- and 2-mm margins to the GTV boundaries (GTV + 1 and 2 mm) were used for SRS planning, dose prescription, and evaluation. Volumetric-modulated arcs with a 5-mm leaf-width multileaf collimator were used to optimize each SRS plan to ensure the steepest dose gradient outside each TV boundary. In dose prescription to the GTV D98%, 0.02-0.3 cc of the GTV is below the prescribed dose, and the volume increases with larger GTVs. The volume below the prescribed dose should be less than the equivalent of a 3-mm-diameter lesion, i.e. 0.01 cc. Therefore, DV-0.01 cc was defined as an alternative near-minimum dose for which the TV below a relevant dose is less than 0.01 cc. Four different dose prescriptions, including the GTV DV-0.01 cc, were compared using specific doses in 1, 3, and 5 fractions, equivalent to 80, 60, and 50 Gy, respectively, as biologically effective doses (BEDs) to the boundaries of GTV, GTV + 1 mm, and GTV + 2 mm, respectively. Results Dose prescription to the GTV DV-0.01 cc corresponds to 95.0, 98.0, and 99.0-99.93% coverages for the GTV of 0.20, 0.50, and 1.00-15.00 cc, respectively. The GTV DV-0.01 cc varied substantially and decreased significantly as the GTV increased in dose prescriptions to the GTV D98%, GTV + 1 mm D95%, and GTV + 2 mm D95%. The GTV + 2 mm DV-0.01 cc increased significantly as the GTV increased, except for the dose prescription to the GTV + 2 mm D95% with a decreasing tendency. When comparing BED-based specific dose prescriptions, dose prescription to the GTV DV-0.01 cc was optimal in terms of the following: 1) consistency of the near-minimum dose of GTV; 2) the highest BED at 2 mm outside the GTV, except for 1.00 cc GTV, and the rational increase with increasing GTV; and 3) the highest BED at 2 mm inside the GTV. In dose prescription with the BED of 80 Gy in 1 fraction and 5 fractions to the GTV DV-0.01 cc, the GTV limits were ≤1.40 and ≤8.46 cc, respectively, in order for the irradiated isodose volume not to exceed the proposed thresholds for minimizing the risk of brain radionecrosis. Conclusions Dose prescription to a fixed % coverage of a GTV with or without a margin leads to the substantially varied near-minimum dose at the GTV boundary, which significantly decreases with increasing GTV. Alternatively, GTV DV-0.01 cc with a variable coverage (D>95%) for >0.20 cc GTV and fixed D95% for ≤0.20 cc GTV is recommended as the basis for dose prescription and evaluation, along with supplemental evaluation of the marginal dose of the GTV plus a margin (e.g. GTV + 2 mm) to demonstrate the appropriateness of dose attenuation outside the GTV boundary.

13.
Cureus ; 16(6): e62784, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39036259

RESUMEN

Introduction In stereotactic radiosurgery (SRS) for brain metastasis (BM), volumetric-modulated arcs (VMA) can provide a suitable dose distribution and efficient delivery, even with a widely available 5-mm leaf-width multileaf collimator (MLC). The planning optimization with affirmatively accepting internal high doses of a gross tumor volume (GTV) enhances the steepness of the dose gradient outside the GTV. However, an excessively steep dose falloff outside a GTV is susceptible to insufficient coverage of inherent irradiation uncertainties with the dose attenuation margin. This study was conducted to examine the appropriateness of dose attenuation margin outside a GTV in 5-mm MLC VMA-based SRS with a steep dose gradient and dose prescription with a biologically effective dose (BED) 80 Gy in various fractions to the GTV margin. Materials and methods This was a planning study for the clinical scenario of a single BM and targeted 28 GTVs, including nine sphere-shaped models with diameters of 5-45 mm and 19 clinical BMs (GTV 0.08-44.33 cc). SRS plans were generated for each GTV using 5-mm MLC VMA with an optimization that prioritized the steepness of dose falloff outside the GTV boundary without any internal dose constraints. A prescribed dose with the BED 80 Gy in 1-10 fraction(s) was assigned to the GTV D V-0.01 cc, a minimum dose of GTV minus 0.01 cc (D >95% for GTV >0.20 cc, D 95% for GTV ≤0.20 cc). The BED was based on the linear-quadratic formula with an alpha/beta ratio of 10 (BED10). Two planning systems were compared for the GTV + 2 mm structures that were generated by adding an isotropic 2-mm margin to the GTV. Results The GTV + 2 mm volumes differed significantly between the systems and further varied on the dose-volume histograms. The D V-0.05 cc, D 98%, and D 95% of the GTV + 2 mm were associated with substantial over- or under-coverages of the GTV + 2 mm, although the irradiated isodose volumes (IIVs) of the D 98% were closest to the GTV + 2 mm in general. The coverage values of the GTV + 2 mm with the minimum dose of the IIV equivalent to the GTV + 2 mm, D eIIV, were 93.3%-98.7% (≥95% in 26 cases). The GTV + 2 mm D eIIV relative to the GTV D V-0.01 cc was ≥81.9% (BED10 ≥60 Gy in ≤5 fractions) in 13 cases, while those were <69.8% (BED10 <48 Gy in ≤5 fractions) in four cases with the GTV of 0.33-1.77 cc. Conclusions A dose attenuation margin outside a GTV can be excessively steep for some small GTVs in 5-mm MLC VMA-based SRS with a steepest dose gradient and a BED10 80 Gy in ≤5 fractions to the GTV D V-0.01 cc, for which an adjustment of the too precipitous dose gradient is preferred to sufficiently cover relevant uncertainties. A GTV + 2 mm D eIIV with ≥95% coverage is more suitable for evaluating the appropriateness of dose attenuation outside the GTV than other common metrics with a fixed % coverage or D V-≤0.05 cc. Given the substantial variability in margin addition functions among planning systems, dose prescription to a margin-added GTV is unsuitable for ensuring uniform dose prescription.

14.
Cureus ; 16(7): e65338, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39184769

RESUMEN

Introduction In stereotactic radiosurgery (SRS) for brain metastasis (BM), the target dose inhomogeneity remains highly variable among modalities, irradiation techniques, and facilities, which can affect tumor response during and after multi-fraction SRS. Volumetric-modulated arcs (VMAs) can provide a concentrically-layered steep dose increase inside a gross tumor volume (GTV) boundary compared to dynamic conformal arcs. This study was conducted to review the optimal evaluation method for the internal GTV doses relevant to maximal response and local control, specifically to examine the significance of the doses 2 mm and 4 mm inside the GTV boundary in VMA-based SRS. Materials and methods This was a planning study for the clinical scenario of a single BM and targeted 25 GTVs of >0.50 cc, including eight spherical models with diameters of 10-45 mm and 17 clinical BMs (GTV: 0.72-44.33 cc). SRS plans were generated for each GTV using VMA with a 5-mm leaf-width multileaf collimator and the optimization that prioritized the steepness of the dose gradient outside the GTV boundary without any internal dose constraints. The dose prescription and evaluation were based on the GTV D V-0.01 cc, a minimum dose of GTV minus 0.01 cc. Two planning systems were compared for the GTV - 2 mm and GTV - 4 mm structures that were generated by equally reducing 2 mm and 4 mm from the GTV surface. The D eIIVs, a minimum dose of the irradiated isodose volume equivalent to the GTV - 2 mm and GTV - 4 mm, were compared to other common metrics. Results The GTV - 2 mm and GTV - 4 mm volumes differed significantly between the systems. In the spherical GTVs, the irradiated isodose surfaces of GTV D 80% and D 50% corresponded to 0.4-1.6 mm (<2 mm) and 1.0-4.6 mm inside the GTV boundary, respectively. In the 25 GTVs, the GTV - 2 mm coverage with the D eIIV varied from 83.7% to 98.2% (95-98% in 68% of the cases), while the GTV coverage with the GTV - 2 mm D eIIV was 20.2-75.9%. In the 23 GTVs of ≥1.26 cc, the GTV coverage with the GTV - 4 mm D eIIV varied from 1.9% to 55.6% (<50% in 87% of the cases). No significant difference was observed between the GTV D 50% and the GTV - 2 mm D eIIV, while the GTV - 4 mm D eIIV was significantly higher than the GTV D 50%. No significant correlations were observed between the GTV D 50% and the D eIIVs of the GTV - 2 mm and GTV - 4 mm. Conclusions The doses 2 mm and 4 mm inside a GTV have low correlations with the GTV D 50% and may be more relevant to maximal response and local control for SRS of BM. The D eIIV instead of the minimum dose of a fixed % coverage (e.g. D 98%) is suitable for reporting the doses 2 mm and 4 mm inside the GTV boundary in terms of avoiding the over- or under-coverage, with consideration to substantial variability in minus margin addition functions among planning systems. In VMA-based SRS with a steep dose gradient, the doses 2-4 mm inside a GTV decrease significantly as the GTV increases, which can attenuate the excessive dose exposure to the surrounding brain in a large BM due to the GTV shrinkage during multi-fraction SRS.

15.
Cureus ; 16(8): e67265, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39301366

RESUMEN

Introduction In linac-based stereotactic radiosurgery (SRS) leveraging a multileaf collimator (MLC) for brain metastasis (BM), volumetric-modulated arcs (VMAs) enable the generation of a suitable dose distribution with efficient planning and delivery. However, the arc arrangement, including the number of arcs, allocation, and rotation ranges, varies substantially among devices and facilities. Some modalities allow coplanar arc(s) (CA(s)) or beam(s) alone, and some facilities only use them intentionally despite the availability of non-coplanar arcs (NCAs). The study was conducted to examine the significance of NCAs and the optimal arc rotation ranges in VMA-based SRS for a single BM. Materials and methods This was a planning study for the clinical scenario of a single BM, including 20 clinical cases with a gross tumor volume (GTV) of 0.72-44.30 cc. Three different arc arrangements were compared: 1) reciprocating double CA alone of each 360º rotation with different collimator angles of 0 and 90º, 2) one CA and two NCAs of each 120º rotation with the shortest beam path lengths to the irradiation isocenter (NCA_L), and 3) one CA of 360º rotation and two NCAs of each 180º rotation (NCA_F). The three arcs were allocated similarly to equally divide the cranial hemisphere with different collimator angles of 0, 45, and 90º. Three VMA-based SRS plans were generated for each GTV using a 5 mm leaf-width MLC with the identical optimization method that prioritized the steepness of dose gradient outside the GTV boundary without any constraints to the GTV internal dose. A prescribed dose was uniformly assigned to the GTV D V-0.01 cc, the minimum dose of GTV minus 0.01 cc. The GTV dose conformity, the steepness of dose gradients both outside and inside the GTV boundary, the degree of concentric lamellarity of the dose gradients, and the appropriateness of the dose attenuation margin outside the GTV boundary were evaluated using metrics appropriate for each. Results The arc arrangements including NCAs showed significantly steeper dose gradients both outside and inside the GTV boundary with smaller dose attenuation margins than the CAs alone, while NCAs showed no significant advantage on the GTV dose conformity. In the NCA-involved arc arrangements, the NCA_F was significantly superior to the NCA_L in terms of the GTV dose conformity, the steepness of dose gradient outside the GTV, the degree of concentric lamellarity of the dose gradients outside and inside the GTV boundary, and the appropriateness of dose attenuation margin. However, the NCA_F showed no significant advantage on the steepness of dose increase inside the GTV boundary over the NCA_L. The dose increase just inside the prescribed isodose surface to the GTV boundary was significantly steeper with the NCA_L than the NCA_F. Conclusions In VMA-based SRS for a single BM, an arc arrangement including NCAs is indispensable, and sufficient arc rotations are suitable for achieving a dose distribution that maximizes therapeutic efficacy and safety in comparison to limited ones which are appropriate for dynamic conformal arcs. Although VMA with CAs alone can provide a non-inferior GTV dose conformity to NCAs, CA(s) alone should be applied only to situations where shorter irradiation time is prioritized over efficacy and safety.

16.
Radiol Case Rep ; 19(2): 586-590, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38074443

RESUMEN

We report a rare case of a primary renal neuroendocrine tumor. The patient was a 64-year-old woman. The patient's chief complaint was gross hematuria. Dynamic contrast-enhanced computed tomography (CT) revealed a hypovascular mass 13 cm in diameter in the right kidney. The border of the mass was clear. A grossly contrast-impaired area and internal granular calcification were observed. A right radical nephrectomy was performed. Macroscopically, the mass was hemorrhaged and necrotic. It was diagnosed as a neuroendocrine tumor (NET) (Grade 2) histologically. Findings, such as hypovascularity, calcification, and necrosis, in our case were similar to those in previous reports. These findings are considered relatively characteristic of primary renal NETs.

17.
Interv Radiol (Higashimatsuyama) ; 9(1): 41-48, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38525000

RESUMEN

Preoperative portal vein embolization is a beneficial option to reduce the risk of postoperative liver failure by promoting the growth of the future liver remnant. In particular, a percutaneous transhepatic procedure (percutaneous transhepatic portal vein embolization) has been developed as a less-invasive approach. Although percutaneous transhepatic portal vein embolization is widely recognized as a safe procedure, various complications, including rare but fatal adverse events, have been reported. Currently, there are no prospective clinical trials regarding percutaneous transhepatic portal vein embolization procedures and no standard guidelines for the PTPE procedure in Japan. As a result, various methods and various embolic materials are used in each hospital according to each physician's policy. The purpose of these guidelines is to propose appropriate techniques at present and to identify issues that should be addressed in the future for safer and more reliable percutaneous transhepatic portal vein embolization techniques.

18.
Radiol Case Rep ; 19(8): 3268-3272, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38812595

RESUMEN

Uterine adenomyomas of endocervical type are rare benign tumors of the uterine cervix commonly presented as cyst-like, dilated glandular structures within polypoid masses. A premenopausal woman in her 50s was referred to our hospital because of an increasing watery vaginal discharge. A multifocal cyst measuring 5 × 4.5 cm in size projecting into the endocervical canal was revealed on a contrast-enhanced MRI. The fluid within the tumor showed a hypointense signal on T1-weighted imaging (T1WI) and a hyperintense signal on T2-weighted imaging (T2WI). On T2WI, most of the septa within the tumor showed a slightly hyperintense to hypointense signal, whereas some areas revealed a strong hypointense signal; the contrast effect on the septum was satisfactory. On the T2WI taken 2 years previously, the tumor was a 4.5 × 3.5 cm polypoid mass protruding from the posterior endocervical wall. Contrastingly, the current T2WI showed that the stem was no longer identifiable because of tumor growth. Because previous imaging showed that the tumor was a stalked tumor protruding from the posterior endocervical wall, the imaging diagnosis was uterine adenomyoma of the endocervical type. A biopsy suggested the possibility of a minimal deviation adenocarcinoma (MDA). Hence, a total hysterectomy was performed. The final diagnosis confirmed the uterine adenomyoma of endocervical type. Uterine adenomyoma of the endocervical type might be difficult to differentiate from MDA in small biopsy specimens; therefore, evaluation of morphology by MRI is considered important in preoperative diagnosis.

19.
J Clin Imaging Sci ; 14: 20, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38975058

RESUMEN

Objectives: The objectives of this study were to clarify the pathological features of clinically significant prostate cancer (csPC) that is undetectable on multiparametric magnetic resonance imaging (mpMRI). Material and Methods: This single-center and retrospective study enrolled 33 men with prostate cancer (PC), encompassing 109 PC lesions, who underwent mpMRI before radical prostatectomy. Two radiologists independently assessed the mpMR images of all lesions and compared them with the pathological findings of PC. All PC lesions were marked on resected specimens using prostate imaging reporting and data system version 2.1 and classified into magnetic resonance imaging (MRI)-detectable and MRI-undetectable PC lesions. Each lesion was classified into csPC and clinically insignificant PC. Pathological characteristics were compared between MRI-detectable and MRI-undetectable csPC. Statistical analysis was performed to identify factors associated with MRI detectability. A logistic regression model was used to determine the factors associated with MRI-detectable and MRI-undetectable csPC. Results: Among 109 PC lesions, MRI-detectable and MRI-undetectable PCs accounted for 31% (34/109) and 69% (75/109) of lesions, respectively. All MRI-detectable PCs were csPC. MRI-undetectable PCs included 30 cases of csPC (40%). The detectability of csPC on mpMRI was 53% (34/64). The MRI-undetectable csPC group had a shorter major diameter (10.6 ± 6.6 mm vs. 19.0 ± 6.9 mm, P < 0.001), shorter minor diameter (5.7 ± 2.9 mm vs. 10.7 ± 3.4 mm, P < 0.001), and lower percentage of lesions with Gleason pattern 5 (17% vs. 71%, P < 0.001). Shorter minor diameter (odds ratio [OR], 2.62; P = 0.04) and lower percentage of Gleason pattern 5 (OR, 24; P = 0.01) were independent predictors of MRI-undetectable csPC. Conclusion: The pathological features of MRI-undetectable csPC included shorter minor diameter and lower percentage of Gleason pattern 5. csPC with shorter minor diameter may not be detected on mpMRI. Some MRI-undetectable csPC lesions exhibited sufficient size and Gleason pattern 5, emphasizing the need for further understanding of pathological factors contributing to MRI detectability.

20.
J Stomatol Oral Maxillofac Surg ; : 101981, 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39067639

RESUMEN

PURPOSE: To determine the superiority of intensity-modulated radiation therapy (IMRT) over three-dimensional conformal radiation therapy (3DCRT) in patients who underwent intra-arterial chemoradiotherapy for oral cancer. METHODS: We retrospectively analyzed patients with locally advanced oral cancer curatively treated with intra-arterial chemoradiotherapy at a single institution between 2010 and 2021. All patients treated after May 2015 underwent IMRT. Docetaxel (12 mg/m2/week) and nedaplatin (5 mg/m2/day) were administered through a shallow temporal artery using a catheter. RESULTS: In total, 143 patients (IMRT: 71; 3DCRT: 72) were included in this study. The 5-year overall survival (OS) and progression-free survival (PFS) rates were 75.7 % and 59.8 %, respectively, with no significant differences between the irradiation methods. In multivariate analysis, cervical lymph node metastasis (LNM) was the only significant poor prognostic factor contributing to OS, PFS, locoregional control (LRC), and local control (LC). In multivariate subgroup analysis of LNM cases (n = 90), IMRT contributed to favorable LRC (hazard ratio [HR]=0.4, P = 0.01) and LC (HR=0.4, P = 0.006). There was no difference in the incidence of grade ≥2 osteonecrosis of the jaw (4.2 % vs. 12.5 %, P = 0.13), xerostomia (75 % vs. 82 %, P = 0.316), or dysgeusia (80 % vs. 82 %, P = 0.834) between the IMRT and 3DCRT groups. However, the rates of xerostomia at 6 months and dysgeusia at 3 months were lower in the IMRT group (both P < 0.001). CONCLUSION: IMRT neither improved patient survival nor significantly reduced the incidence of osteonecrosis of the jaw. However, it demonstrated favorable LRC and LC in patients with LNM, suggesting an advantage in early recovery from xerostomia and dysgeusia.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA