Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Curr Opin Cardiol ; 39(3): 226-233, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38391273

RESUMEN

PURPOSE OF REVIEW: This review offers insights into percutaneous mitral valve management, emphasizing pivotal trials that contributed to its evolution. RECENT FINDINGS: Mitral regurgitation (MR) is a highly prevalent heart valve disease, with surgical intervention being the gold standard for managing primary MR. However, a notable proportion of patients face ineligibility criteria or are at high surgical risk, particularly in the setting of secondary MR. To fill this gap, transcatheter therapies have emerged as less invasive alternatives. Initially guided by the EVEREST trial criteria, transcatheter leaflet repair techniques have shown impressive technological improvements, addressing nowadays a wide range of anatomical scenarios. Evidence supporting the safety and efficacy of transcatheter leaflet repair is derived from pivotal trials, including EVEREST II, COAPT, MITRA-FR, and CLASP IID, and large multicenter registries including EXPAND, EXPAND G4, and EuroSMR. However, not all patients meet the anatomical and clinical criteria for leaflet repair. For those patients, transcatheter mitral valve replacement may be a minimally invasive option and multiple clinical trials are current underway. SUMMARY: From MitraClip to newer and more innovative technologies, the landscape of percutaneous mitral valve interventions continues to evolve, offering new hopes to patients who may not be ideal candidates for conventional surgery.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Enfermedades de las Válvulas Cardíacas/cirugía , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Estudios Multicéntricos como Asunto
2.
J Interv Cardiol ; 2022: 4368887, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35600211

RESUMEN

Transcatheter aortic valve replacement (TAVR) to treat degeneration of bioprosthetic heart valves (BHVs), called as valve-in-valve (ViV), is becoming a key feature since the number of BHVs requiring intervention is increasing and many patients are at high risk for a redo cardiac surgery. However, a TAVR inside a small previous cardiac valve may lead to prosthesis-patient mismatch (PPM) and not be as effective as we hoped for. An effective option to decrease the chance of PPM is to fracture the previous heart valve implanted using a high-pressure balloon. By performing a valve fracture, the inner valve ring of small BHVs can be opened up by a single fracture line, allowing subsequent implantation of a properly sized transcatheter heart valve, without increasing substantially the procedure risk. In this article, we provide a step-by-step procedure on how to safely and properly fracture a BHV and report a case of a TAVR in a degenerated rapid deployment valve.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Diseño de Prótesis , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
J Card Surg ; 37(7): 2053-2059, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35249238

RESUMEN

INTRODUCTION: The proportion of patients with symptomatic severe aortic stenosis treated by transcatheter aortic valve replacement (TAVR) is increasing, driven by favorable outcomes from randomized trials and current valve guidelines recommendations. Despite device and technique improvements having reduced procedural morbidities, complications during or immediately after TAVR still carries significant mortality risk. METHODS: We propose a check-list of essential items to anticipate potentially life-threatening complications in TAVR. RESULTS: Purpose of this review is to discuss the most common life-threatening complications during TAVR from a troubleshooting perspective, depicting the minimum required equipment needed in emergency situations. CONCLUSIONS: Prevention of complications remains the most important strategy to optimize outcomes in TAVR procedures. Each specialized Center should institute and make easily accessible standardized emergency kits for the most common life-threatening conditions during TAVR that should be readily available in the cath-lab or hybrid operating room.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Humanos , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 98(6): E971-E976, 2021 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-34533899

RESUMEN

Optimal transseptal puncture (TSP) position on the interatrial septum as well as proper catheter direction and maneuverability in the left atrium (LA) are key elements for successful mitral valve (MV) interventions. TSP is usually performed from the right femoral vein being more comfortable for the operator and easier to reach the fossa ovalis. In the cases reported, TSP was performed from left femoral vein (LFV) to improve delivery system maneuverability and trajectory inside the LA in the context of MV repair with MitraClip. According to this early experience, LFV approach might be considered as first choice or as an alternative solution in patients in whom a higher position of the delivery system relative to the mitral annulus is needed.


Asunto(s)
Tabique Interatrial , Válvula Mitral , Tabique Interatrial/diagnóstico por imagen , Tabique Interatrial/cirugía , Cateterismo Cardíaco , Vena Femoral/diagnóstico por imagen , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 31(5): 1003-1008, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32270559

RESUMEN

In December 2019, the world started to face a new pandemic situation, the severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2). Although coronavirus disease (COVID-19) clinical manifestations are mainly respiratory, major cardiac complications are being reported. Cardiac manifestations etiology seems to be multifactorial, comprising direct viral myocardial damage, hypoxia, hypotension, enhanced inflammatory status, ACE2-receptors downregulation, drug toxicity, endogenous catecholamine adrenergic status, among others. Studies evaluating patients with COVID-19 presenting cardiac injury markers show that it is associated with poorer outcomes, and arrhythmic events are not uncommon. Besides, drugs currently used to treat the COVID-19 are known to prolong the QT interval and can have a proarrhythmic propensity. This review focus on COVID-19 cardiac and arrhythmic manifestations and, in parallel, makes an appraisal of other virus epidemics as SARS-CoV, Middle East respiratory syndrome coronavirus, and H1N1 influenza.


Asunto(s)
Arritmias Cardíacas/complicaciones , Cardiomiopatías/complicaciones , Infecciones por Coronavirus/complicaciones , Coronavirus , Miocarditis/complicaciones , Neumonía Viral/complicaciones , Arritmias Cardíacas/virología , Betacoronavirus , COVID-19 , Cardiomiopatías/virología , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/epidemiología , Humanos , Masculino , Miocarditis/virología , Pandemias , Neumonía Viral/diagnóstico , Neumonía Viral/epidemiología , SARS-CoV-2
6.
J Card Surg ; 35(8): 1905-1911, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32598521

RESUMEN

BACKGROUND: Infective endocarditis (IE) remains an expressive health problem with high morbimortality rates. Despite its importance, epidemiological and microbiological data remain scarce, especially in developing countries. AIM: This study aims to describe IE epidemiological, clinical, and microbiological profile in a tertiary university center in South America, and to identify in-hospital mortality rate and predictors. METHODS: An observational, retrospective study of 167 patients, who fulfilled modified Duke's criteria during a six-year enrollment period, from January 2010 to December 2015. The primary outcome was defined as in-hospital mortality analyzed according to treatment received (clinical vs surgical). Multivariate analysis identified mortality predictors. RESULTS: The median age was 60 years (Q1 -Q3 50-71), and 66% were male. Echocardiogram demonstrated vegetations in 90.4%. An infective agent was identified in 76.6%, being Staphylococcus aureus (19%), Enterococcus (12%), coagulase-negative staphylococci (10%), and Streptococcus viridans (9.6%) the most prevalent. Overall in-hospital mortality was 41.9%, varying from 49.4% to 34.1%, in clinical and surgical patients, respectively (P = .047). On multivariate analysis, diabetes mellitus (odds ratio [OR], 2.5), previous structural heart disease (OR, 3.1), and mitral valve infection (OR, 2.1) were all-cause death predictors. Surgical treatment was the only variable related to a better outcomes (OR, 0.45; 95% Confidence Interval, 0.2-0.9). CONCLUSION: This study presents IE profile and all-cause mortality in a large patient's cohort, comprising a 6-years' time window, a rare initiative in developing countries. Elderly and male patients predominated, while S. aureus was the main microbiological agent. Patients conservatively treated presented higher mortality than surgically managed ones. Epidemiological studies from developing countries are essential to increase IE understanding.


Asunto(s)
Endocarditis/epidemiología , Mortalidad Hospitalaria , Estudios de Cohortes , Endocarditis/microbiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Pronóstico , Estudios Retrospectivos , América del Sur/epidemiología , Factores de Tiempo
7.
J Surg Oncol ; 112(1): 56-9, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26175279

RESUMEN

BACKGROUND: Although totally implantable venous access devices (TIVAD) are increasingly being used in oncology patients, more robust evidence about the best technique is lacking, especially regarding to ultrasound (US) guided puncture. METHODS: One hundred ten patients with indication of intravenous chemotherapy were randomly assigned to TIVAD implant through US-guided internal jugular vein (USG) puncture (39) or internal jugular vein blindly (IJB) (36) or subclavian vein blindly (SCB) (35). Procedure data and complications were prospectively recorded within 30 days of the procedure. RESULTS: All patients completed the follow up. Immediate complication rate was 5.1%, 13.9%, and 0% in the USG, IJB, and SCB groups, respectively (P = 0.05). First attempt success rate was 79.5% in the USG, 52.8% in the IJB and 47.2% in the SCB group (P = 0.012). Technique failure was observed in 2.6%, 22.2%, and 8.6% of the population in the USG, IJB, and SCB, respectively (P = 0.021). Early complication rate was 5.1% in USG group, 2.8% in the IJB, and 0% in the SCB (P = 0.401). CONCLUSION: The findings of our study suggest superiority of the USG approach in terms of first puncture success rate and technique failure, without increasing the procedure duration. Long-term follow-up results should help to further clarify the current debates.


Asunto(s)
Cateterismo Venoso Central/instrumentación , Catéteres de Permanencia , Bombas de Infusión Implantables , Venas Yugulares , Neoplasias/tratamiento farmacológico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico
8.
J Clin Med ; 12(4)2023 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-36835878

RESUMEN

Transcatheter aortic valve implantation (TAVI) went through a huge evolution in the last decades. Previously performed under general anesthesia, with transoperative transesophageal echocardiography guidance and using cutdown femoral artery access, the procedure has now evolved into a minimalist approach, with local anesthesia, conscious sedation, and the avoidance of invasive lines becoming the new standards. Here, we discuss the minimalist TAVI approach and how we incorporate it into our current clinical practice.

9.
Expert Rev Cardiovasc Ther ; 21(6): 397-407, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37144916

RESUMEN

INTRODUCTION: Tricuspid regurgitation has been increasingly recognized as a clinically relevant entity with a long-term prognostic impact on quality of life and survival. Despite this, there are still some unmet clinical needs regarding the management of tricuspid regurgitation that require further investigation. AREAS COVERED: This review addresses current evidence for the treatment of tricuspid regurgitation, focusing primarily on new catheter-based technologies. In addition, we discuss recent registries and clinical trial outcomes. EXPERT OPINION: A multimodality and multiparametric integrative approach has been preconized to assess tricuspid regurgitation mechanism and severity, and new technologies have been developed to address the main causative factors of tricuspid regurgitation. Matching the right device to the right patient and deciding when is the best time for intervention are major challenges in the management of tricuspid regurgitation.


Asunto(s)
Insuficiencia de la Válvula Tricúspide , Humanos , Cateterismo Cardíaco/efectos adversos , Pronóstico , Calidad de Vida , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía
10.
Braz J Cardiovasc Surg ; 38(2): 312-315, 2023 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-36260001

RESUMEN

Although the endovascular repair of descending thoracic aorta diseases is an already consolidated procedure, this approach is not well-established for ascending aorta and arch pathologies. A 71-year-old male patient who had undergone an open ascending aorta replacement ten years ago presented with a huge dissected aortic arch aneurysm. Vascular accesses were obtained with ultrasound-guided punctures, followed by aortic arch exclusion using aortic endoprostheses and the chimney-graft technique for preserving supra-aortic branches flow. This case demonstrates the feasibility of a totally percutaneous aortic arch repair provided that careful preprocedural planning and a dedicated team are available for such a challenging intervention.


Asunto(s)
Aneurisma de la Aorta Torácica , Enfermedades de la Aorta , Implantación de Prótesis Vascular , Disección de la Aorta Torácica , Procedimientos Endovasculares , Masculino , Humanos , Anciano , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/métodos , Stents , Procedimientos Endovasculares/métodos , Enfermedades de la Aorta/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Prótesis Vascular , Resultado del Tratamiento
11.
Braz J Cardiovasc Surg ; 38(2): 278-288, 2023 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-36459472

RESUMEN

Coordinated and harmonic (synchronous) ventricular electrical activation is essential for better left ventricular systolic function. Intraventricular conduction abnormalities, such as left bundle branch block due to artificial cardiac pacing, lead to electromechanical "dyssynchronopathy" with deleterious structural and clinical consequences. The aim of this review was to describe and improve the understanding of all the processes connecting the several mechanisms involved in the development of artificially induced ventricular dyssynchrony by cardiac pacing, most known as pacing-induced cardiomyopathy (PiCM). The chronic effect of abnormal impulse conduction and nonphysiological ectopic activation by artificial cardiac pacing is suspected to affect metabolism and myocardial perfusion, triggering regional differences in the activation/contraction processes that cause electrical and structural remodeling due to damage, inflammation, and fibrosis of the cardiac tissue. The effect of artificial cardiac pacing on ventricular function and structure can be multifactorial, and biological factors underlying PiCM could affect the time and probability of developing the condition. PiCM has not been included in the traditional classification of cardiomyopathies, which can hinder detection. This article reviews the available evidence for pacing-induced cardiovascular disease, the current understanding of its pathophysiology, and reinforces the adverse effects of right ventricular pacing, especially right ventricular pacing burden (commonly measured in percentage) and its repercussion on ventricular contraction (reflected by the impact on left ventricular systolic function). These effects might be the main defining criteria and determining mechanisms of the pathophysiology and the clinical repercussion seen on patients.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Humanos , Cardiomiopatías/etiología , Cardiomiopatías/terapia , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Estimulación Cardíaca Artificial/efectos adversos , Función Ventricular Izquierda , Arritmias Cardíacas
12.
JACC Cardiovasc Interv ; 16(10): 1176-1188, 2023 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-37225288

RESUMEN

BACKGROUND: Although >150,000 mitral TEER procedures have been performed worldwide, the impact of MR etiology on MV surgery after TEER remains unknown. OBJECTIVES: The authors sought to compare outcomes of mitral valve (MV) surgery after failed transcatheter edge-to-edge repair (TEER) stratified by mitral regurgitation (MR) etiology. METHODS: Data from the CUTTING-EDGE registry were retrospectively analyzed. Surgeries were stratified by MR etiology: primary (PMR) and secondary (SMR). MVARC (Mitral Valve Academic Research Consortium) outcomes at 30 days and 1 year were evaluated. Median follow-up was 9.1 months (IQR: 1.1-25.8 months) after surgery. RESULTS: From July 2009 to July 2020, 330 patients underwent MV surgery after TEER, of which 47% had PMR and 53.0% had SMR. Mean age was 73.8 ± 10.1 years, median STS risk at initial TEER was 4.0% (IQR: 2.2%-7.3%). Compared with PMR, SMR had a higher EuroSCORE, more comorbidities, lower LVEF pre-TEER and presurgery (all P < 0.05). SMR patients had more aborted TEER (25.7% vs 16.3%; P = 0.043), more surgery for mitral stenosis after TEER (19.4% vs 9.0%; P = 0.008), and fewer MV repairs (4.0% vs 11.0%; P = 0.019). Thirty-day mortality was numerically higher in SMR (20.4% vs 12.7%; P = 0.072), with an observed-to-expected ratio of 3.6 (95% CI: 1.9-5.3) overall, 2.6 (95% CI: 1.2-4.0) in PMR, and 4.6 (95% CI: 2.6-6.6) in SMR. SMR had significantly higher 1-year mortality (38.3% vs 23.2%; P = 0.019). On Kaplan-Meier analysis, the actuarial estimates of cumulative survival were significantly lower in SMR at 1 and 3 years. CONCLUSIONS: The risk of MV surgery after TEER is nontrivial, with higher mortality after surgery, especially in SMR patients. These findings provide valuable data for further research to improve these outcomes.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Sistema de Registros
13.
J Clin Med ; 11(17)2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36079102

RESUMEN

It is so exciting to imagine that the heart, once considered an untouchable organ, is now routinely approached by so many different techniques and with a wide array of invasiveness [...].

14.
J Clin Med ; 11(17)2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36079111

RESUMEN

Transcatheter aortic valve implantation (TAVI) to treat patients with severe symptomatic aortic stenosis is a well-established procedure. Even though cases series have reported TAVI use in high-risk patients with pure native aortic regurgitation, this is still considered an off-label intervention, especially when the aortic annulus dimensions are beyond the recommended by prosthesis manufacturers. Herein, we provide an updated review regarding the transcatheter treatment of pure native aortic regurgitation and illustrate this issue by presenting a clinical case of a patient with pure aortic regurgitation and a large aortic annulus who received a self-expanding non-dedicated transcatheter heart valve.

15.
J Clin Med ; 11(9)2022 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-35566708

RESUMEN

Transcatheter aortic valve replacement (TAVR) is a well-established treatment option for patients with severe symptomatic aortic stenosis (AS) whose procedural efficacy and safety have been continuously improving. Appropriate preprocedural planning, including aortic valve annulus measurements, transcatheter heart valve choice, and possible procedural complication anticipation is mandatory to a successful procedure. The gold standard for preoperative planning is still to perform a multi-detector computed angiotomography (MDCT), which provides all the information required. Nonetheless, 3D echocardiography and magnet resonance imaging (MRI) are great alternatives for some patients. In this article, we provide an updated comprehensive review, focusing on preoperative TAVR planning and the standard steps required to do it properly.

16.
Eur J Cardiothorac Surg ; 61(5): 967-976, 2022 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-34662376

RESUMEN

OBJECTIVES: Transcatheter aortic valve replacement (TAVR) represents a valid treatment for patients with aortic valve stenosis and high or intermediate surgical risk. However, biological transcatheter valves can also experience a structural degeneration after years, and a redo-TAVR procedure (TAVR-in-TAVR) can be a valid option. We revised the current available literature for indications, procedural and technical details and outcome on TAVR-in-TAVR procedures for degenerated TAVR valves. METHODS: A systematic search was conducted in the public medical database for scientific articles on TAVR-in-TAVR procedures for degenerated transcatheter valves. Data on demographics, indications, first and second transcatheter valve type and size, mortality, complications and follow-up were extracted and analysed. RESULTS: A total of 13 studies (1 multicentre, 3 case series, 9 case reports) were included in this review, with a total amount of 160 patients treated with TAVR-in-TAVR procedures for transcatheter valve failure. The mean age was 74.8 ± 7.8 with 84 males (52.8%). The mean elapsed time from the first TAVR procedure was 58.1 ± 23.4 months. Main indication for TAVR-in-TAVR was pure stenosis (38.4%, with mean gradient of 44.5 ± 18.5 mmHg), regurgitation (31.4%), mixed stenosis and regurgitation (29.5%) and leaflet thrombosis (8.8%). Procedural success rate was 86.8%, with second TAVR valve malposition occurred in 4 cases (2.5%). The hospital mortality rate was 1.25% (2/160). Post-procedural echocardiographic control showed moderate regurgitation in 5.6% of patients (9/160) and residual transvalvular mean gradient ≥20 mmHg in 5% of cases. Postoperative complications included major vascular complications (8.7%), new pacemaker implantation (8.7%), acute kidney failure (3.7%), stroke (0.6%) and coronary obstruction (0.6%). The mean follow-up time was 6 ± 5.6 months with 1 non-cardiovascular death reported. CONCLUSIONS: TAVR-in-TAVR represents a valid alternative to standard surgery for the treatment of degenerated transcatheter valves in high-risk patients. Despite these promising results, further studies are required to assess durability and haemodynamic performances of the second TAVR valve.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Constricción Patológica/etiología , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Diseño de Prótesis , Reoperación , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
17.
JACC Cardiovasc Interv ; 15(4): 411-422, 2022 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-35210047

RESUMEN

OBJECTIVES: This study evaluated the incidence, management, and outcome of patients who experienced MitraClip (Abbott Vascular) failure secondary to loss of leaflet insertion (LLI), single leaflet detachment (SLD), or embolization. BACKGROUND: Transcatheter edge-to-edge repair with MitraClip is an established therapy for the treatment of mitral regurgitation (MR), but no data exist regarding the prevalence and outcome according to the mode of clip failure. METHODS: Between January 2009 and December 2020, we retrospectively screened 4,294 procedures of MitraClip performed in 19 centers. LLI was defined as damage to the leaflet where the MitraClip was attached, SLD as demonstration of complete separation between the device and a single leaflet tissue, and clip embolization as loss of contact between MitraClip and both leaflets. RESULTS: A total of 147 cases of MitraClip failure were detected (overall incidence = 3.5%), and these were secondary to LLI or SLD in 47 (31.9%) and 99 (67.3%) cases, respectively, whereas in 1 (0.8%) case clip embolization was observed. MitraClip failure occurred in 67 (45.5%) patients with functional MR, in 64 (43.5%) patients with degenerative MR, and 16 (10.8%) with mixed etiology. Although the majority of MitraClip failures were detected before discharge (47 intraprocedural and 42 in the hospital), up to 39.5% of cases were diagnosed at follow-up. In total, 80 (54.4%) subjects underwent a redo procedure, either percutaneously with MitraClip (n = 51, 34.7%) or surgically (n = 36, 24.5%) including 4 cases of surgical conversion of the index procedure and 7 cases of bailout surgery after unsuccessful redo MitraClip. After a median follow-up of 163 days (IQR: 22-720 days), 50 (43.9%) subjects presented moderate to severe MR, and 43 (29.3%) patients died. An up-front redo MitraClip strategy was associated with a trend toward a reduced rate of death at follow-up vs surgical or conservative management (P = 0.067), whereas postprocedural acute kidney injury, age, and moderate to severe tricuspid regurgitation were independent predictors of death. CONCLUSIONS: MitraClip failure secondary to LLI and SLD is not a rare phenomenon and may occur during and also beyond hospitalization. Redo MitraClip strategy demonstrates a trend toward a reduced risk of death compared with bailout surgery and conservative management. A third of those patients remained with more than moderate MR and had substantial mortality at the intermediate-term follow-up.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
18.
Neurochem Res ; 36(3): 487-93, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21184279

RESUMEN

In the present study we investigated the effect of chronic variable stress (CVS) on some parameters of the immune system, including levels of cytokines [interleukin 1ß (IL-1 ß), interleukin 6 (IL-6), tumor necrosis factor α (TNF- α)] and chemokine CCL2 (MCP-1) in the hippocampus of rats. Acetylcholinesterase activity was also evaluated. Sixty-day old Wistar rats were submitted to different mild stressors for 40 days. After the last stress section, the cytokines and MCP-1 were determined by immunoassay and acetylcholinesterase activity by colorimetric method. Results showed that chronic stress significantly increased the levels of IL-1ß, IL-6 and TNF-α, but did not alter the levels of MCP-1. In addition, acetylcholinesterase activity was increased in the hippocampus of rats subjected to CVS. These findings suggest that inflammation and cholinergic dysfunction may be, at least in part, important contributors to the neurological dysfunction observed in some depressed patients.


Asunto(s)
Acetilcolinesterasa/metabolismo , Quimiocina CCL2/inmunología , Citocinas/inmunología , Inflamación/inmunología , Estrés Psicológico/inmunología , Glándulas Suprarrenales/anatomía & histología , Animales , Peso Corporal , Hipocampo/metabolismo , Masculino , Tamaño de los Órganos , Ratas , Ratas Wistar
19.
Expert Rev Cardiovasc Ther ; 19(1): 47-59, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33244998

RESUMEN

Introduction: The interest in tricuspid regurgitation (TR) surgical treatment has grown in the last years, mostly motivated by the trend for early intervention and the development of minimally invasive surgical techniques. Despite this, there is still a lack of evidence regarding when to intervene in functional tricuspid regurgitation outside the context of left-sided valve surgery and when is the best time to approach primary tricuspid regurgitation. Areas covered: Herein, we present the state-of-the-art in tricuspid regurgitation surgical intervention, covering indications, optimum time, surgical options, and outcomes, as well as the role of transcatheter tricuspid valve intervention in the current era. Expert opinion: Current evidence support that the indications and timing of tricuspid valve invasive management should be centered on a range of factors, including patients' characteristics, disease stage, and anatomical considerations. Early intervention, before severe right ventricle dysfunction and pulmonary hypertension, seems to results in better postoperative outcomes. Transcatheter techniques are arising as potential alternatives for inoperable and high-risk patients.


Asunto(s)
Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Humanos , Hipertensión Pulmonar/etiología , Procedimientos Quirúrgicos Mínimamente Invasivos , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/fisiopatología
20.
Braz J Cardiovasc Surg ; 36(2): 237-243, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33355810

RESUMEN

With transcatheter aortic valve implantation (TAVI) technology expanding its indications for low-risk patients, the number of TAVI-eligible patients will globally grow, requiring a better understanding about the second-best access choice. Regarding the potential access sites, the transfemoral retrograde route is recognized as the standard approach and first choice according to current guidelines. However, this approach is not suitable in up to 10-15% of patients, for whom an alternative non-femoral access is required. Among the alternative non-femoral routes, the transaxillary approach has received increasing recognition due to its proximity and relatively straight course from the axillary artery to the aortic annulus, which provides a more accurate device deployment. Here we discuss some particular aspects of the transaxillary access, either percutaneously performed or by cutdown dissection.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Arteria Axilar/cirugía , Cateterismo Cardíaco , Arteria Femoral/cirugía , Humanos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA