Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(12): 2461-2471, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37702156

RESUMEN

INTRODUCTION: Treatment of recurrent atrial fibrillation (AF) is sometimes challenging due to non-pulmonary vein (PV) foci. Fractionated signal area in the atrial muscle (FAAM) is a valid predictor of the location of non-PV foci. FAAM ablation has the potential to decrease the recurrence rate of atrial tachyarrhythmia in patients with recurrent AF. We compared the clinical impact of FAAM ablation for recurrent AF, using 1 year follow up date. METHODS: A total of 230 consecutive patients with symptomatic recurrent AF who underwent catheter ablation specifically targeting non-PV foci as FAAM-guided ablation (n = 113) and non-FAAM-guided ablation (n = 117) were retrospectively analyzed. FAAM was assigned a parameter (peaks slider, which indicates the number of components of fractionated signals), ranging from 1 to 15, indicating the location of the FAAM (1: largest, 15: smallest). FAAM-guided ablation was performed by ablating FAAM until none inducibility of non-PV foci. On the other hand, non-FAAM-guided ablation was performed via linear ablation, complex fractionated atrial electrogram ablation, superior vena cava isolation, and focal ablation according to the location of the non-PV foci. The RHYTHMIA system was used to perform all the procedures. The primary endpoints were AF recurrence, atrial flutter, and/or atrial tachycardia. RESULTS: After a 1-year follow up, freedom from atrial tachyarrhythmia was achieved in 90.3% and 75.2% of patients in the FAAM and non-FAAM groups, respectively (hazard ratio = 0.438 [95% confidence interval: 0.243-0.788], p = .005). CONCLUSIONS: FAAM ablation showed a promising decrease in the recurrence rate of atrial tachyarrhythmia in patients with recurrent AF during a 1-year follow-up.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios de Seguimiento , Estudios Retrospectivos , Vena Cava Superior , Resultado del Tratamiento , Taquicardia , Músculos/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia
2.
J Cardiovasc Electrophysiol ; 32(2): 224-234, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33270298

RESUMEN

BACKGROUND: The role of nonpulmonary vein (PV) triggers ablation in persistent atrial fibrillation (PEAF) was suggested but it is still under debate. OBJECTIVES: We aimed to assess the effectiveness of non-PV trigger-targeted ablation for patients with PEAF. METHODS: Consecutive patients with PEAF undergoing catheter ablation (CA) between January 2015 and April 2017 were enrolled. Isoproterenol plus adenosine challenge was performed to provoke non-PV triggers. Non-PV triggers were defined as the trigger beats inducing AF (non-PV AF triggers) and/or frequent premature contractions (non-PV PACs) from other than PVs. Three groups were defined: Group 1 (n = 186) without non-PV triggers; Group 2 (n = 65) with non-PV triggers that could be completely eliminated with CA; Group 3 (n = 49) with non-PV triggers still inducible after CA. The primary endpoint was freedom from any atrial tachyarrhythmia (ATa) recurrence. RESULTS: A total of 300 patients (230 males, age 64 ± 10) were enrolled. The mean follow-up period was 27 ± 10 months. Freedom from ATa recurrence at 1 and 2 years were significantly lower in Group 3 compared to the other two groups (Group 1; 74.7%, 67.2% vs. Group 2; 75.8%, 68.3% vs. Group 3: 52.1%, 38.6%, p = .0005), irrespective of the type of non-PV triggers (non-PV AF triggers vs. non-PV PACs). On multivariate analysis, unsuccessful elimination of non-PV triggers was an independent predictor for ATa recurrence (hazard ratio = 1.80, 95% confidence interval = 1.07-2.95, p = .026). CONCLUSION: Successful non-PV triggers elimination can improve the ATa recurrence rate in PEAF ablation. ATa recurrence rate is higher, if non-PV AF triggers or even non-PV PACs remain in patients with PEAF.


Asunto(s)
Fibrilación Atrial , Complejos Atriales Prematuros , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Complejos Atriales Prematuros/diagnóstico , Ablación por Catéter/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
3.
J Interv Card Electrophysiol ; 67(3): 589-597, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37691083

RESUMEN

BACKGROUND: Lesion formation during catheter ablation is influenced by the power, contact force (CF), time, and catheter stability. However, the influence of the irrigation effects on lesion formation remains unknown. METHODS: An ex vivo experiment using conductive gel was performed. Using three different catheter designs (TactiFlex ™ SE [TF], IntellaNav MiFi ™ OI [MiFi], QDOT MICRO™ [QDOT]), a cross-sectional analysis of the lesion size and surface lesion type of 10g/40W lesions with a combination of various ablation times was performed in protocol 1. A longitudinal analysis (combination of various powers [30, 40, and 50W] and various ablation times with a 10g setting) was performed to investigate the influence of the auto-regulated irrigation system (QDOT) on lesion formation in protocol 2. RESULTS: The lesion formation with the QDOT catheter tended to create larger ablation lesions, while that with the TF catheter created smaller lesions than the other catheters. The lesion surface characteristics were divided into two patterns: ring (MiFi catheter and QDOT) and crescent (TF) patterns. The auto-regulated irrigation system did not influence the lesion formation, and the relationship between the lesion formation and RF energy exhibited similar changes regardless of the ablation power setting. CONCLUSION: The lesion formation and lesion surface characteristics differed among the different irrigation tip designs. An auto-regulated irrigation system did not affect the lesion creation or surface lesion characteristics. Care should be given to the inter-product differences in the lesion characteristics during RF catheter ablation, partly due to the irrigation flow control and tip design.


Asunto(s)
Ablación por Catéter , Irrigación Terapéutica , Humanos , Estudios Transversales , Irrigación Terapéutica/métodos , Catéteres , Ablación por Catéter/métodos , Impedancia Eléctrica , Diseño de Equipo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA