Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Ear Hear ; 39(4): 712-719, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29240567

RESUMEN

OBJECTIVES: Cochlear implantation surgery has been shown to result in trauma to inner ear sensory structures, resulting in loss of residual hearing. Localized therapeutic hypothermia has been shown in clinical care to be a neuroprotective intervention. Previously, we have shown in an experimental model that localized hypothermia protects cochlear hair cells and residual hearing function against surgical and cochlear implantation trauma. Using experimental temperature measurements carried out in human cadaver temporal bones and a finite element model of the inner ear, the present study examined the temperature distribution of a custom-designed hypothermia delivery system in the human inner ear organs. DESIGN: The efficacy of the hypothermia probe and resulting heat distribution across human cochlea and surrounding tissues were modeled in three-dimensional in COMSOL. The geometry and dimensions of inner ear and temporal bones were derived from computed tomographic and magnetic resonance imaging images. Model predictions were compared with experimental observations from five human temporal bones. RESULTS: In both the modeling and experimental studies, the cochlear temperature was lowered by 4 to 6 °C on the round window from a baseline of 37 °C within 16 to 18 minutes. The model simulations showed uniformly distributed cooling across the cochlea. This study provides insight for design, operation, and protocols for efficacious delivery of mild therapeutic hypothermia to the human cochlea that may significantly benefit patients undergoing surgical cochlear implantation by preserving residual hearing. CONCLUSION: There was a close correlation between the results of the numerical simulations and experimental observations in this study. Our custom-designed system is capable of effectively providing mild therapeutic hypothermia locally to the human cochlea. When combined with results from in vivo animal experiments, the present study suggests that the application of localized therapeutic hypothermia may hold potential for patients with an aim to preserve residual hearing after cochlear implantation.


Asunto(s)
Cóclea , Implantación Coclear , Audición , Hipotermia Inducida/métodos , Cuidados Posoperatorios/métodos , Temperatura , Cadáver , Oído Interno , Análisis de Elementos Finitos , Humanos , Imagenología Tridimensional , Modelos Teóricos
2.
Hear Res ; 428: 108680, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36586170

RESUMEN

OBJECTIVE: Mild therapeutic hypothermia (MTH) has been demonstrated to prevent residual hearing loss from surgical trauma associated with cochlear implant (CI) insertion. Here, we aimed to characterize the mechanisms of MTH-induced hearing preservation in CI in a well-established preclinical rodent model. APPROACH: Rats were divided into four experimental conditions: MTH-treated and implanted cochleae, cochleae implanted under normothermic conditions, MTH only cochleae and un-operated cochleae (controls). Auditory brainstem responses (ABRs) were recorded at different time points (up to 84 days) to confirm long-term protection and safety of MTH locally applied to the cochlea for 20 min before and after implantation. Transcriptome sequencing profiling was performed on cochleae harvested 24 h post CI and MTH treatment to investigate the potential beneficial effects and underlying active gene expression pathways targeted by the temperature management. RESULTS: MTH treatment preserved residual hearing up to 3 months following CI when compared to the normothermic CI group. In addition, MTH applied locally to the cochleae using our surgical approach was safe and did not affect hearing in the long-term. Results of RNA sequencing analysis highlight positive modulation of signaling pathways and gene expression associated with an activation of cellular inflammatory and immune responses against the mechanical damage caused by electrode insertion. SIGNIFICANCE: These data suggest that multiple and possibly independent molecular pathways play a role in the protection of residual hearing provided by MTH against the trauma of cochlear implantation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva , Hipotermia Inducida , Ratas , Animales , Implantación Coclear/efectos adversos , Implantes Cocleares/efectos adversos , Cóclea/lesiones , Pérdida Auditiva/genética , Pérdida Auditiva/prevención & control , Hipotermia Inducida/métodos
3.
J Neural Eng ; 17(2): 026035, 2020 04 29.
Artículo en Inglés | MEDLINE | ID: mdl-32240985

RESUMEN

OBJECTIVE: Neuroprosthetics hold tremendous promise to restore function through brain-computer interfaced devices. However, clinical applications of implantable microelectrodes remain limited given the challenges of maintaining neuronal signals for extended periods of time and with multiple biological mechanisms negatively affecting electrode performance. Acute and chronic inflammation, oxidative stress, and blood brain barrier disruption contribute to inconsistent electrode performance. We hypothesized that therapeutic hypothermia (TH) applied at the microelectrode insertion site will positively modulate both inflammatory and apoptotic pathways, promoting neuroprotection and improved performance in the long-term. APPROACH: A custom device and thermoelectric system were designed to deliver controlled TH locally to the cortical implant site at the time of microelectrode array insertion and immediately following surgery. The TH paradigm was derived from in vivo cortical temperature measurements and finite element modeling of temperature distribution profiles in the cortex. Male Sprague-Dawley rats were implanted with non-functional Utah microelectrodes arrays (UMEA) consisting of 4 × 4 grid of 1.5 mm long parylene-coated silicon shanks. In one group, TH was applied to the implant site for two hours following the UMEA implantation, while the other group was implanted under normothermic conditions without treatment. At 48 h, 72 h, 7 d and 14 d post-implantation, mRNA expression levels for genes associated with inflammation and apoptosis were compared between normothermic and hypothermia-treated groups. MAIN RESULTS: The custom system delivered controlled TH to the cortical implant site and the numerical models confirmed that the temperature decrease was confined locally. Furthermore, a one-time application of TH post UMEA insertion significantly reduced the acute inflammatory response with a reduction in the expression of inflammatory regulating cytokines and chemokines. SIGNIFICANCE: This work provides evidence that acutely applied hypothermia is effective in significantly reducing acute inflammation post intracortical electrode implantation.


Asunto(s)
Hipotermia Inducida , Inflamación , Animales , Electrodos Implantados , Inflamación/prevención & control , Masculino , Microelectrodos , Ratas , Ratas Sprague-Dawley , Utah
4.
Hear Res ; 339: 32-9, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27260269

RESUMEN

OBJECTIVE: The trauma caused during cochlear implant insertion can lead to cell death and a loss of residual hair cells in the cochlea. Various therapeutic approaches have been studied to prevent cochlear implant-induced residual hearing loss with limited success. In the present study, we show the efficacy of mild to moderate therapeutic hypothermia of 4 to 6 °C applied to the cochlea in reducing residual hearing loss associated with the electrode insertion trauma. APPROACH: Rats were randomly distributed in three groups: control contralateral cochleae, normothermic implanted cochleae and hypothermic implanted cochleae. Localized hypothermia was delivered to the middle turn of the cochlea for 20 min before and after implantation using a custom-designed probe perfused with cooled fluorocarbon. Auditory brainstem responses (ABRs) were recorded to assess the hearing function prior to and post-cochlear implantation at various time points up to 30 days. At the conclusion of the trials, inner ears were harvested for histology and cell count. The approach was extended to cadaver temporal bones to study the potential surgical approach and efficacy of our device. In this case, the hypothermia probe was placed next to the round window niche via the facial recess or a myringotomy. MAIN RESULTS: A significant loss of residual hearing was observed in the normothermic implant group. Comparatively, the residual hearing in the cochleae receiving therapeutic hypothermia was significantly conserved. Histology confirmed a significant loss of outer hair cells in normothermic cochleae receiving the surgical trauma when compared to the hypothermia treated group. In human temporal bones, a controlled and effective cooling of the cochlea was achieved using our approach. SIGNIFICANCE: Collectively, these results suggest that therapeutic hypothermia during cochlear implantation may reduce traumatic effects of electrode insertion and improve conservation of residual hearing.


Asunto(s)
Cóclea/fisiopatología , Implantación Coclear/instrumentación , Implantes Cocleares/efectos adversos , Pérdida Auditiva/fisiopatología , Audición , Hipotermia Inducida/métodos , Animales , Audiometría de Tonos Puros , Umbral Auditivo , Cóclea/fisiología , Oído Interno/fisiopatología , Electrodos , Electrodos Implantados/efectos adversos , Potenciales Evocados Auditivos del Tronco Encefálico , Células Ciliadas Auditivas Externas/patología , Pérdida Auditiva Sensorineural/fisiopatología , Ratas , Ratas Endogámicas BN , Ventana Redonda/cirugía , Hueso Temporal/patología , Investigación Biomédica Traslacional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA