Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Catheter Cardiovasc Interv ; 97(4): E580-E587, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32894804

RESUMEN

OBJECTIVES: We sought to document aortic cusps fluoroscopic projections and their distributions using leaflet alignment which is a novel concept to optimize visualization of leaflets and for guiding BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent coronary artery obstruction) and determine whether these projections were feasible in catheter laboratory. BACKGROUND: Optimal fluoroscopic projections of aortic valve cusps have not been well described. METHODS: A total of 128 pre-transcatheter aortic valve replacement (pre-TAVR) computed tomographies (CT) (72 native valves and 56 bioprosthetic surgical valves) were analyzed. Using CT software (3Mensio, Pie medical imaging, the Netherlands), leaflet alignment was performed and the feasibility of these angles, which were defined as rate of obtainable with efforts (within LAO/RAO of 85° and CRA/CAU of 50°) were evaluated. RESULTS: High feasibility was seen in right coronary cusp (RCC) front view (100%) and left coronary cusp (LCC) side view (99.2%), followed by noncoronary cusp side view (95.3%). In contrast, low feasibility of RCC side view (7.8%) and LCC front view (47.6%) was observed. No statistical differences were seen between the distribution of native valves and bioprosthetic surgical valves. With patient/table tilt of 20°LAO and 10°CRA, the feasibility of RCC side view and LCC front view increased to 43.7 and 85.2%, respectively. CONCLUSION: Distributions of each cusp's leaflet alignment follows "sigmoid curve" which can provide better understanding of aortic valve cusp orientation in TAVR and BASILICA. RCC side view used in right cusp BASILICA is commonly unachievable in catheter laboratory and may improve with patient/table tilt.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
J Cardiovasc Comput Tomogr ; 14(6): 516-519, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32199758

RESUMEN

BACKGROUND: Eccentricity of coronary ostial positions in relation to the aortic valve cusp may influence the target laceration location in BASILICA (Bioprosthetic or native Aortic Scallop Intentional Laceration to prevent Coronary Artery obstruction). Eccentricity of the coronary ostia in relation to coronary cusps of native and valve-in-valve transcatheter aortic valve replacement (TAVR) was not well described before. METHODS: A total of 121 pre-TAVR patients' CT data (72 native valves TAVR and 49 bioprosthetic surgical valves TAVR) was included and coronary ostial eccentricity angles were measured and compared. Coronary ostial angles were measured between mid-cusp line to coronary ostium in CT perpendicular images. RESULTS: In the overall cohort, the right coronary artery (RCA) had an eccentric origin in the majority of cases, favoring the commissure between the right and the non coronary cusp (17.0°, IQR; 10-25). On the other hand, the left coronary artery (LCA) originated most commonly near center of the cusp position (0°, IQR; -8 -7.5) In comparison of native and bioprosthetic valves, RCA ostial angles were more eccentric in native valves (19.0°, IQR; 12-26) than in bioprosthetic valves (14.0°, IQR; 3-20) (p = 0.004). Whereas, LCA ostial angle has no significant differences between native valves (-2.0°, IQR;-7.75-5.75) and bioprosthetic valves (1°, IQR;-8-13), (p = 0.6). CONCLUSION: RCA ostia often have an eccentric origin towards the non-coronary cusp, especially in native aortic valves, while LCA ostia commonly originate near the center of the cusp. This finding may contribute to better performance of BASILICA procedures.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Estenosis Coronaria/prevención & control , Vasos Coronarios/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Tomografía Computarizada Multidetector , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/etiología , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
JACC Cardiovasc Interv ; 13(2): 210-216, 2020 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-31883715

RESUMEN

OBJECTIVES: The aim of this study was to report the 1-year results of transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli. BACKGROUND: Favorable 30-day outcomes of S3 TAVR in annuli >683 mm2 have previously been reported. Pacemaker implantation rates were acceptable, and a larger left ventricular outflow tract and more eccentric annular anatomy were associated with increasing paravalvular leak. METHODS: From December 2013 to December 2018, 105 patients across 15 centers with mean area 721.3 ± 36.1 mm2 (range 683.5 to 852.0 mm2) underwent TAVR using an S3 device. Clinical, anatomic, and procedural characteristics were analyzed. One-year survival and echocardiographic follow-up were reached in 94.3% and 82.1% of patients, respectively. Valve Academic Research Consortium-2 30-day and 1-year outcomes were reported. RESULTS: The mean age was 76.9 ± 10.4 years, and Society of Thoracic Surgeons predicted risk score averaged 5.2 ± 3.4%. One-year overall mortality and stroke rates were 18.2% and 2.4%, respectively. Quality-of-life index improved from baseline to 30 days and at 1 year (p < 0.001 for both). Mild paravalvular aortic regurgitation occurred in 21.7% of patients, while moderate or greater paravalvular aortic regurgitation occurred in 4.3%. Mild and moderate or severe transvalvular aortic regurgitation occurred in 11.6% and 0%, respectively. Valve gradients remained stable at 1 year. CONCLUSIONS: S3 TAVR in annular areas >683 mm2 is feasible, with favorable mid-term outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Masculino , América del Norte , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
4.
JACC Cardiovasc Interv ; 11(14): 1377-1387, 2018 07 23.
Artículo en Inglés | MEDLINE | ID: mdl-29960755

RESUMEN

OBJECTIVES: The aim of this study was to determine factors affecting paravalvular leak (PVL) in transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli. BACKGROUND: The largest recommended annular area for the 29-mm S3 is 683 mm2. However, experience with S3 TAVR in annuli >683 mm2 has not been widely reported. METHODS: From December 2013 to July 2017, 74 patients across 16 centers with mean area 721 ± 38 mm2 (range: 684 to 852 mm2) underwent S3 TAVR. The transfemoral approach was used in 95%, and 39% were under conscious sedation. Patient, anatomic, and procedural characteristics were retrospectively analyzed. Valve Academic Research Consortium-2 outcomes were reported. RESULTS: Procedural success was 100%, with 2 deaths, 1 stroke, and 2 major vascular complications at 30 days. Post-dilatation occurred in 32%, with final balloon overfilling (1 to 5 ml extra) in 70% of patients. Implantation depth averaged 22.3 ± 12.4% at the noncoronary cusp and 20.7 ± 9.9% at the left coronary cusp. New left bundle branch block occurred in 17%, and 6.3% required new permanent pacemakers. Thirty-day echocardiography showed mild PVL in 22.3%, 6.9% moderate, and none severe. There was no annular rupture or coronary obstruction. Mild or greater PVL was associated with larger maximum annular and left ventricular outflow tract (LVOT) diameters, larger LVOT area and perimeter, LVOT area greater than annular area, and higher annular eccentricity. CONCLUSIONS: TAVR with the 29-mm S3 valve beyond the recommended range by overexpansion is safe, with acceptable PVL and pacemaker rates. Larger LVOTs and more eccentric annuli were associated with more PVL. Longer term follow-up will be needed to determine durability of S3 TAVR in this population.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Humanos , Masculino , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
5.
J Cardiol Cases ; 13(4): 105-108, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30546619

RESUMEN

A 68-year-old woman presented to our hospital with unstable angina and was admitted for further evaluation. While hospitalized, she developed persistent angina with hypotension along with ST-segment elevation in leads V1-V2 along with lead aVR elevation on 12-lead electrocardiogram. Coronary angiography revealed diffuse multi-vessel coronary vasospasm most notably in the left anterior descending artery (LAD). Due to incomplete resolution of vasospasm with intracoronary verapamil and nitroglycerin, along with hemodynamic compromise requiring an intra-aortic balloon pump, percutaneous coronary intervention (PCI) of the LAD was performed. Clinical workup revealed hypereosinophlia and elevated IgE; diagnosis of eosinophilic granulomatosis with polyangiitis was confirmed with evidence of radiographic migratory pulmonary infiltrates and airway obstruction on spirometry. The patient had recurrent angina after PCI but her symptoms resolved fully after a course of corticosteroids. We attribute her refractory vasospastic angina to previously undiagnosed small/medium-vessel vasculitis. .

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA