1.
Crit Rev Clin Lab Sci ; 60(7): 502-517, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37194676

RESUMEN

Quality control practices in the modern laboratory are the result of significant advances over the many years of the profession. Major advance in conventional internal quality control has undergone a philosophical shift from a focus solely on the statistical assessment of the probability of error identification to more recent thinking on the capability of the measurement procedure (e.g. sigma metrics), and most recently, the risk of harm to the patient (the probability of patient results being affected by an error or the number of patient results with unacceptable analytical quality). Nonetheless, conventional internal quality control strategies still face significant limitations, such as the lack of (proven) commutability of the material with patient samples, the frequency of episodic testing, and the impact of operational and financial costs, that cannot be overcome by statistical advances. In contrast, patient-based quality control has seen significant developments including algorithms that improve the detection of specific errors, parameter optimization approaches, systematic validation protocols, and advanced algorithms that require very low numbers of patient results while retaining sensitive error detection. Patient-based quality control will continue to improve with the development of new algorithms that reduce biological noise and improve analytical error detection. Patient-based quality control provides continuous and commutable information about the measurement procedure that cannot be easily replicated by conventional internal quality control. Most importantly, the use of patient-based quality control helps laboratories to improve their appreciation of the clinical impact of the laboratory results produced, bringing them closer to the patients.Laboratories are encouraged to implement patient-based quality control processes to overcome the limitations of conventional internal quality control practices. Regulatory changes to recognize the capability of patient-based quality approaches, as well as laboratory informatics advances, are required for this tool to be adopted more widely.

2.
Clin Chem Lab Med ; 60(4): 636-644, 2022 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-35107229

RESUMEN

OBJECTIVES: Within-subject biological variation (CVi ) is a fundamental aspect of laboratory medicine, from interpretation of serial results, partitioning of reference intervals and setting analytical performance specifications. Four indirect (data mining) approaches in determination of CVi were directly compared. METHODS: Paired serial laboratory results for 5,000 patients was simulated using four parameters, d the percentage difference in the means between the pathological and non-pathological populations, CVi the within-subject coefficient of variation for non-pathological values, f the fraction of pathological values, and e the relative increase in CVi of the pathological distribution. These parameters resulted in a total of 128 permutations. Performance of the Expected Mean Squares method (EMS), the median method, a result ratio method with Tukey's outlier exclusion method and a modified result ratio method with Tukey's outlier exclusion were compared. RESULTS: Within the 128 permutations examined in this study, the EMS method performed the best with 101/128 permutations falling within ±0.20 fractional error of the 'true' simulated CVi , followed by the result ratio method with Tukey's exclusion method for 78/128 permutations. The median method grossly under-estimated the CVi . The modified result ratio with Tukey's rule performed best overall with 114/128 permutations within allowable error. CONCLUSIONS: This simulation study demonstrates that with careful selection of the statistical approach the influence of outliers from pathological populations can be minimised, and it is possible to recover CVi values close to the 'true' underlying non-pathological population. This finding provides further evidence for use of routine laboratory databases in derivation of biological variation components.


Asunto(s)
Minería de Datos , Proyectos de Investigación , Simulación por Computador , Humanos , Laboratorios , Valores de Referencia
3.
Clin Chem Lab Med ; 60(8): 1164-1174, 2022 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-35647783

RESUMEN

OBJECTIVES: One approach to assessing reference material (RM) commutability and agreement with clinical samples (CS) is to use ordinary least squares or Deming regression with prediction intervals. This approach assumes constant variance that may not be fulfilled by the measurement procedures. Flexible regression frameworks which relax this assumption, such as quantile regression or generalized additive models for location, scale, and shape (GAMLSS), have recently been implemented, which can model the changing variance with measurand concentration. METHODS: We simulated four imprecision profiles, ranging from simple constant variance to complex mixtures of constant and proportional variance, and examined the effects on commutability assessment outcomes with above four regression frameworks and varying the number of CS, data transformations and RM location relative to CS concentration. Regression framework performance was determined by the proportion of false rejections of commutability from prediction intervals or centiles across relative RM concentrations and was compared with the expected nominal probability coverage. RESULTS: In simple variance profiles (constant or proportional variance), Deming regression, without or with logarithmic transformation respectively, is the most efficient approach. In mixed variance profiles, GAMLSS with smoothing techniques are more appropriate, with consideration given to increasing the number of CS and the relative location of RM. In the case where analytical coefficients of variation profiles are U-shaped, even the more flexible regression frameworks may not be entirely suitable. CONCLUSIONS: In commutability assessments, variance profiles of measurement procedures and location of RM in respect to clinical sample concentration significantly influence the false rejection rate of commutability.


Asunto(s)
Estándares de Referencia , Humanos
4.
Crit Rev Clin Lab Sci ; 58(1): 49-59, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32795201

RESUMEN

Delta checks are a post-analytical verification tool that compare the difference in sequential laboratory results belonging to the same patient against a predefined limit. This unique quality tool highlights a potential error at the individual patient level. A difference in sequential laboratory results that exceeds the predefined limit is considered likely to contain an error that requires further investigation that can be time and resource intensive. This may cause a delay in the provision of the result to the healthcare provider or entail recollection of the patient sample. Delta checks have been used primarily to detect sample misidentification (sample mix-up, wrong blood in tube), and recent advancements in laboratory medicine, including the adoption of protocolized procedures, information technology and automation in the total testing process, have significantly reduced the prevalence of such errors. As such, delta check rules need to be selected carefully to balance the clinical risk of these errors and the need to maintain operational efficiency. Historically, delta check rules have been set by professional opinion based on reference change values (biological variation) or the published literature. Delta check rules implemented in this manner may not inform laboratory practitioners of their real-world performance. This review discusses several evidence-based approaches to the optimal setting of delta check rules that directly inform the laboratory practitioner of the error detection capabilities of the selected rules. Subsequent verification of workflow for the selected delta check rules is also discussed. This review is intended to provide practical assistance to laboratories in setting evidence-based delta check rules that best suits their local operational and clinical needs.


Asunto(s)
Laboratorios , Humanos , Control de Calidad , Valores de Referencia
5.
Clin Chem Lab Med ; 58(3): 384-389, 2020 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-31734649

RESUMEN

Background The delta check time interval limit is the maximum time window within which two sequential results of a patient will be evaluated by the delta check rule. The impact of time interval on delta check performance is not well studied. Methods De-identified historical laboratory data were extracted from the laboratory information system and divided into children (≤18 years) and adults (>21 years). The relative and absolute differences of the original pair of results from each patient were compared against the delta check limits associated with 90% specificity. The data were then randomly reshuffled to simulate a switched (misidentified) sample scenario. The data were divided into 1-day, 3-day, 7-day, 14-day, 1-month, 3-month, 6-month and 1-year time interval bins. The true positive- and false-positive rates at different intervals were examined. Results Overall, 24 biochemical and 20 haematological tests were analysed. For nearly all the analytes, there was no statistical evidence of any difference in the true- or false-positive rates of the delta check rules at different time intervals when compared to the overall data. The only exceptions to this were mean corpuscular volume (using both relative- and absolute-difference delta check) and mean corpuscular haemoglobin (only absolute-difference delta check) in the children population, where the false-positive rates became significantly lower at 1-year interval. Conclusions This study showed that there is no optimal delta check time interval. This fills an important evidence gap for future guidance development.


Asunto(s)
Análisis de Datos , Proyectos de Investigación , Técnicas de Laboratorio Clínico , Humanos , Factores de Tiempo
6.
Nat Methods ; 13(10): 833-6, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27525975

RESUMEN

Sample heterogeneity often masks DNA methylation signatures in subpopulations of cells. Here, we present a method to genotype single cells while simultaneously interrogating gene expression and DNA methylation at multiple loci. We used this targeted multimodal approach, implemented on an automated, high-throughput microfluidic platform, to assess primary lung adenocarcinomas and human fibroblasts undergoing reprogramming by profiling epigenetic variation among cell types identified through genotyping and transcriptional analysis.


Asunto(s)
Epigénesis Genética/ética , Heterogeneidad Genética , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Análisis de Secuencia de ADN/métodos , Análisis de la Célula Individual/métodos , Técnicas de Cultivo de Célula , Línea Celular Tumoral , Reprogramación Celular/genética , Dermatoglifia del ADN , Metilación de ADN/genética , Fibroblastos , Marcadores Genéticos , Humanos , Neoplasias Pulmonares/genética , Procedimientos Analíticos en Microchip/métodos
7.
PLoS Comput Biol ; 14(3): e1005966, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29505572

RESUMEN

Cell size is thought to play an important role in choosing between temporal and spatial sensing in chemotaxis. Large cells are thought to use spatial sensing due to large chemical difference at its ends whereas small cells are incapable of spatial sensing due to rapid homogenization of proteins within the cell. However, small cells have been found to polarize and large cells like sperm cells undergo temporal sensing. Thus, it remains an open question what exactly governs spatial versus temporal sensing. Here, we identify the factors that determines sensing choices through mathematical modeling of chemotactic circuits. Comprehensive computational search of three-node signaling circuits has identified the negative integral feedback (NFB) and incoherent feedforward (IFF) circuits as capable of adaptation, an important property for chemotaxis. Cells are modeled as one-dimensional circular system consisting of diffusible activator, inactivator and output proteins, traveling across a chemical gradient. From our simulations, we find that sensing outcomes are similar for NFB or IFF circuits. Rather than cell size, the relevant parameters are the 1) ratio of cell speed to the product of cell diameter and rate of signaling, 2) diffusivity of the output protein and 3) ratio of the diffusivities of the activator to inactivator protein. Spatial sensing is favored when all three parameters are low. This corresponds to a cell moving slower than the time it takes for signaling to propagate across the cell diameter, has an output protein that is polarizable and has a local-excitation global-inhibition system to amplify the chemical gradient. Temporal sensing is favored otherwise. We also find that temporal sensing is more robust to noise. By performing extensive literature search, we find that our prediction agrees with observation in a wide range of species and cell types ranging from E. coli to human Fibroblast cells and propose that our result is universally applicable.


Asunto(s)
Quimiotaxis/fisiología , Simulación por Computador , Modelos Biológicos , Biología Computacional , Escherichia coli/fisiología
8.
Phys Biol ; 14(4): 046003, 2017 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-28639563

RESUMEN

A multilayered epithelium is made up of individual cells that are stratified in an orderly fashion, layer by layer. In such tissues, individual cells can adopt a wide range of shapes ranging from columnar to squamous. From histological images, we observe that, in flat epithelia such as the skin, the cells in the top layer are squamous while those in the middle and bottom layers are columnar, whereas in tubular epithelia, the cells in all layers are columnar. We develop a computational model to understand how individual cell shape is governed by the mechanical forces within multilayered flat and curved epithelia. We derive the energy function for an epithelial sheet of cells considering intercellular adhesive and intracellular contractile forces. We determine computationally the cell morphologies that minimize the energy function for a wide range of cellular parameters. Depending on the dominant adhesive and contractile forces, we find four dominant cell morphologies for the multilayered-layered flat sheet and three dominant cell morphologies for the two-layered curved sheet. We study the transitions between the dominant cell morphologies for the two-layered flat sheet and find both continuous and discontinuous transitions and also the presence of multistable states. Matching our computational results with histological images, we conclude that apical contractile forces from the actomyosin belt in the epithelial cells is the dominant force determining cell shape in multilayered epithelia. Our computational model can guide tissue engineers in designing artificial multilayered epithelia, in terms of figuring out the cellular parameters needed to achieve realistic epithelial morphologies.


Asunto(s)
Adhesión Celular , Forma de la Célula , Células Epiteliales/citología , Modelos Biológicos , Actomiosina/metabolismo , Biología Computacional , Epitelio/fisiología
9.
Mol Syst Biol ; 9: 631, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23295860

RESUMEN

Establishment of cell polarity is crucial for many biological processes including cell migration and asymmetric cell division. The establishment of cell polarity consists of two sequential processes: an external gradient is first sensed and then the resulting signal is amplified and maintained by intracellular signaling networks usually using positive feedback regulation. Generally, these two processes are intertwined and it is challenging to determine which proteins contribute to the sensing or amplification process, particularly in multicellular organisms. Here, we integrated phenomenological modeling with quantitative single-cell measurements to separate the sensing and amplification components of Wnt ligands and receptors during establishment of polarity of the Caenorhabditis elegans P cells. By systematically exploring how P-cell polarity is altered in Wnt ligand and receptor mutants, we inferred that ligands predominantly affect the sensing process, whereas receptors are needed for both sensing and amplification. This integrated approach is generally applicable to other systems and will facilitate decoupling of the different layers of signal sensing and amplification.


Asunto(s)
Proteínas de Caenorhabditis elegans/metabolismo , Caenorhabditis elegans/citología , Polaridad Celular/fisiología , Receptores Wnt/metabolismo , Proteínas Wnt/metabolismo , Animales , División Celular Asimétrica , Caenorhabditis elegans/fisiología , Proteínas de Caenorhabditis elegans/genética , Proteínas de Unión al ADN/genética , Proteínas de Unión al ADN/metabolismo , Regulación Fúngica de la Expresión Génica , Glicoproteínas/genética , Glicoproteínas/metabolismo , Proteínas de la Membrana/genética , Proteínas de la Membrana/metabolismo , Modelos Biológicos , Mutación , Receptores Wnt/genética , Análisis de la Célula Individual , Factores de Transcripción/genética , Factores de Transcripción/metabolismo , Proteínas Wnt/genética , beta Catenina/metabolismo
10.
Interdiscip Sci ; 16(1): 73-90, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37776475

RESUMEN

In cancer treatment, adaptive therapy holds promise for delaying the onset of recurrence through regulating the competition between drug-sensitive and drug-resistant cells. Adaptive therapy has been studied in well-mixed models assuming free mixing of all cells and spatial models considering the interactions of single cells with their immediate adjacent cells. Both models do not reflect the spatial structure in glandular tumours where intra-gland cellular interaction is high, while inter-gland interaction is limited. Here, we use mathematical modelling to study the effects of adaptive therapy on glandular tumours that expand using either glandular fission or invasive growth. A two-dimensional, lattice-based model of sites containing sensitive and resistant cells within individual glands is developed to study the evolution of glandular tumour cells under continuous and adaptive therapies. We found that although both growth models benefit from adaptive therapy's ability to prevent recurrence, invasive growth benefits more from it than fission growth. This difference is due to the migration of daughter cells into neighboring glands that is absent in fission but present in invasive growth. The migration resulted in greater mixing of cells, enhancing competition induced by adaptive therapy. By varying the initial spatial spread and location of the resistant cells within the tumour, we found that modifying the conditions within the resistant cells containing glands affect both fission and invasive growth. However, modifying the conditions surrounding these glands affect invasive growth only. Our work reveals the interplay between growth mechanism and tumour topology in modulating the effectiveness of cancer therapy.


Asunto(s)
Neoplasias , Humanos , Modelos Teóricos
11.
Adv Clin Chem ; 115: 175-203, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37673520

RESUMEN

Delta check is an electronic error detection tool. It compares the difference in sequential results within a patient against a predefined limit, and when exceeded, the delta check rule is considered triggered. The patient results should be withheld for review and troubleshooting before releasing to the clinical team for patient management. Delta check was initially developed as a tool to detect wrong-blood-in-tube (sample misidentification) errors. It is now applied to detect errors more broadly within the total testing process. Recent advancements in the theoretical understanding of delta check has allowed for more precise application of this tool to achieve the desired clinical performance and operational set up. In this Chapter, we review the different pre-implementation considerations, the foundation concepts of delta check, the process of setting up key delta check parameters, performance verification and troubleshooting of a delta check flag.

12.
Ann Lab Med ; 43(1): 5-18, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36045052

RESUMEN

Background: Calibration is a critical component for the reliability, accuracy, and precision of mass spectrometry measurements. Optimal practice in the construction, evaluation, and implementation of a new calibration curve is often underappreciated. This systematic review examined how calibration practices are applied to liquid chromatography-tandem mass spectrometry measurement procedures. Methods: The electronic database PubMed was searched from the date of database inception to April 1, 2022. The search terms used were "calibration," "mass spectrometry," and "regression." Twenty-one articles were identified and included in this review, following evaluation of the titles, abstracts, full text, and reference lists of the search results. Results: The use of matrix-matched calibrators and stable isotope-labeled internal standards helps to mitigate the impact of matrix effects. A higher number of calibration standards or replicate measurements improves the mapping of the detector response and hence the accuracy and precision of the regression model. Constructing a calibration curve with each analytical batch recharacterizes the instrument detector but does not reduce the actual variability. The analytical response and measurand concentrations should be considered when constructing a calibration curve, along with subsequent use of quality controls to confirm assay performance. It is important to assess the linearity of the calibration curve by using actual experimental data and appropriate statistics. The heteroscedasticity of the calibration data should be investigated, and appropriate weighting should be applied during regression modeling. Conclusions: This review provides an outline and guidance for optimal calibration practices in clinical mass spectrometry laboratories.


Asunto(s)
Calibración , Cromatografía Liquida/métodos , Humanos , Espectrometría de Masas , Estándares de Referencia , Reproducibilidad de los Resultados
13.
Ann Lab Med ; 43(5): 408-417, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37080741

RESUMEN

Functional reference limits describe key changes in the physiological relationship between a pair of physiologically related components. Statistically, this can be represented by a significant change in the curvature of a mathematical function or curve (e.g., an observed plateau). The point at which the statistical relationship changes significantly is the point of curvature inflection and can be mathematically modeled from the relationship between the interrelated biomarkers. Conceptually, they reside between reference intervals, which describe the statistical boundaries of a single biomarker within the reference population, and clinical decision limits that are often linked to the risk of morbidity or mortality and set as thresholds. Functional reference limits provide important physiological and pathophysiological insights that can aid laboratory result interpretation. Laboratory professionals are in a unique position to harness data from laboratory information systems to derive clinically relevant values. Increasing research on and reporting of functional reference limits in the literature will enhance their contribution to laboratory medicine and widen the evidence base used in clinical decision limits, which are currently almost exclusively contributed to by clinical trials. Their inclusion in laboratory reports will enhance the intellectual value of laboratory professionals in clinical care beyond the statistical boundaries of a healthy reference population and pave the way to them being considered in shaping clinical decision limits. This review provides an overview of the concepts related to functional reference limits, clinical examples of their use, and the impetus to include them in laboratory reports.


Asunto(s)
Técnicas de Laboratorio Clínico , Laboratorios , Humanos , Valores de Referencia , Biomarcadores
14.
Ann Lab Med ; 42(5): 597-601, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-35470278

RESUMEN

This study describes an objective approach to deriving the clinical performance of autoverification rules to inform laboratory practice when implementing them. Anonymized historical laboratory data for 12 biochemistry measurands were collected and Box-Cox-transformed to approximate a Gaussian distribution. The historical laboratory data were assumed to be error-free. Using the probability theory, the clinical specificity of a set of autoverification limits can be derived by calculating the percentile values of the overall distribution of a measurand. The 5th and 95th percentile values of the laboratory data were calculated to achieve a 90% clinical specificity. Next, a predefined tolerable total error adopted from the Royal College of Pathologists of Australasia Quality Assurance Program was applied to the extracted data before subjecting to Box-Cox transformation. Using a standard normal distribution, the clinical sensitivity can be derived from the probability of the Z-value to the right of the autoverification limit for a one-tailed probability and multiplied by two for a two-tailed probability. The clinical sensitivity showed an inverse relationship with between-subject biological variation. The laboratory can set and assess the clinical performance of its autoverification rules that conforms to its desired risk profile.


Asunto(s)
Laboratorios , Humanos
15.
Clin Biochem ; 105-106: 57-63, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35489473

RESUMEN

BACKGROUND: Between-subject biological variation (CVg) is an important parameter in several aspects of laboratory practice, including setting of analytical performance specification, delta checks and calculation of index of individuality. Using simulations, we compare the performance of two indirect (data mining) approaches for deriving CVg. METHODS: The expected mean squares (EMS) method was compared against that proposed by Harris and Fraser. Using numerical simulations, d the percentage difference in the mean between the non-pathological and pathological populations, CVi the within-subject coefficient of variation of the non-pathological distribution, f the fraction of pathological values, and e the relative increase in CVi of the pathological distribution were varied for a total of 320 conditions to examine the impact on the relative fractional of error of the recovered CVg compared to the true value. RESULTS: Comparing the two methods, the EMS and Harris and Fraser's approaches yielded similar performance of 158 conditions and 157 conditions within ± 0.20 fractional error of the true underlying CVg, for the normal and lognormal distributions, respectively. It is observed that both EMS and Harris and Fraser's method performed better using the calculated CVi rather than the actual ('presumptive') CVi. The number of conditions within 0.20 fractional error of the true underlying CVg did not differ significantly between the normal and lognormal distributions. The estimation of CVg improved with decreasing values of f, d and CViCVg. DISCUSSIONS: The two statistical approaches included in this study showed reliable performance under the simulation conditions examined.


Asunto(s)
Variación Biológica Poblacional , Laboratorios , Simulación por Computador , Minería de Datos , Humanos , Valores de Referencia
16.
Clin Biochem ; 103: 16-24, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35181292

RESUMEN

BACKGROUND: Indirect reference intervals and biological variation studies heavily rely on statistical methods to separate pathological and non-pathological subpopulations within the same dataset. In recognition of this, we compare the performance of eight univariate statistical methods for identification and exclusion of values originating from pathological subpopulations. METHODS: The eight approaches examined were: Tukey's rule with and without Box-Cox transformation; median absolute deviation; double median absolute deviation; Gaussian mixture models; van der Loo (Vdl) methods 1 and 2; and the Kosmic approach. Using four scenarios including lognormal distributions and varying the conditions through the number of pathological populations, central location, spread and proportion for a total of 256 simulated mixed populations. A performance criterion of ± 0.05 fractional error from the true underlying lower and upper reference interval was chosen. RESULTS: Overall, the Kosmic method was a standout with the highest number of scenarios lying within the acceptable error, followed by Vdl method 1 and Tukey's rule. Kosmic and Vdl method 1 appears to discriminate better the non-pathological reference population in the case of log-normal distributed data. When the proportion and spread of pathological subpopulations is high, the performance of statistical exclusion deteriorated considerably. DISCUSSIONS: It is important that laboratories use a priori defined clinical criteria to minimise the proportion of pathological subpopulation in a dataset prior to analysis. The curated dataset should then be carefully examined so that the appropriate statistical method can be applied.


Asunto(s)
Laboratorios , Proyectos de Investigación , Humanos , Valores de Referencia
17.
Small Methods ; 6(8): e2200185, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35652511

RESUMEN

During the past decade, breakthroughs in sequencing technology have provided the basis for studies of the myriad ways in which microbial communities in and on the human body influence human health and disease. In almost every medical specialty, there is now a growing interest in accurate and quantitative profiling of the microbiota for use in diagnostic and therapeutic applications. However, the current next-generation sequencing approach for microbiome profiling is costly, requires laborious library preparation, and is challenging to scale up for routine diagnostics. Split, Amplify, and Melt analysis of BActeria-community (SAMBA), a novel multicolor digital melting polymerase chain reaction platform with unprecedented multiplexing capability is presented, and the capability to distinguish and quantify 16 bacteria species in mixtures is demonstrated. Subsequently, SAMBA is applied to measure the compositions of bacteria in the gut microbiome to identify microbial dysbiosis related to colorectal cancer. This rapid, low cost, and high-throughput approach will enable the implementation of microbiome diagnostics in clinical laboratories and routine medical practice.


Asunto(s)
Microbiota , Bacterias/genética , Disbiosis , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Microbiota/genética , Reacción en Cadena de la Polimerasa
18.
Mol Syst Biol ; 6: 358, 2010 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-20393578

RESUMEN

Most eukaryotes contain many tandem repeats of ribosomal RNA genes of which only a subset is transcribed at any given time. Current biochemical methods allow for the determination of the fraction of transcribing repeats (ON) versus non-transcribing repeats (OFF) but do not provide any dynamical information and obscure any transcription activity at the single-cell level. Here, we use a fluorescence in situ hybridization (FISH) technique that allows the detection of single-RNA molecules in individual yeast cells. We use this method complemented with theoretical modeling to determine the rate of switching from OFF to ON (activation rate) and the average number of RNA molecules produced during each transcriptional burst (burst size). We explore how these two variables change in mutants and different growth conditions, and show that this method resolves changes in these two variables even when the average rDNA expression is unaltered. These phenotypic changes could not have been detected by traditional biochemical assays.


Asunto(s)
ADN Ribosómico/genética , Modelos Genéticos , Transcripción Genética , ADN Ribosómico/metabolismo , Proteínas Fúngicas/genética , Proteínas Fúngicas/metabolismo , Genes Fúngicos , Histona Desacetilasas/genética , Histona Desacetilasas/metabolismo , Hibridación Fluorescente in Situ , Microscopía , ARN de Hongos/genética , ARN de Hongos/metabolismo , ARN Mensajero/genética , ARN Mensajero/metabolismo , Levaduras/citología , Levaduras/genética , Levaduras/metabolismo
19.
Clin Biochem ; 98: 63-69, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34534518

RESUMEN

INTRODUCTION: Internal quality control (IQC) is traditionally interpreted against predefined control limits using multi-rules or 'Westgard rules'. These include the commonly used 1:3s and 2:2s rules. Either individually or in combination, these rules have limited sensitivity for detection of systematic errors. In this proof-of-concept study, we directly compare the performance of three moving average algorithms with Westgard rules for detection of systematic error. METHODS: In this simulation study, 'error-free' IQC data (control case) was generated. Westgard rules (1:3s and 2:2s) and three moving average algorithms (simple moving average (SMA), weighted moving average (WMA), exponentially weighted moving average (EWMA); all using ±3SD as control limits) were applied to examine the false positive rates. Following this, systematic errors were introduced to the baseline IQC data to evaluate the probability of error detection and average number of episodes for error detection (ANEed). RESULTS: From the power function graphs, in comparison to Westgard rules, all three moving average algorithms showed better probability of error detection. Additionally, they also had lower ANEed compared to Westgard rules. False positive rates were comparable between the moving average algorithms and Westgard rules (all <0.5%). The performance of the SMA algorithm was comparable to the weighted algorithms forms (i.e. WMA and EWMA). CONCLUSION: Application of an SMA algorithm on IQC data improves systematic error detection compared to Westgard rules. Application of SMA algorithms can simplify laboratories IQC strategy.


Asunto(s)
Algoritmos , Laboratorios , Modelos Teóricos , Lenguajes de Programación , Control de Calidad , Humanos
20.
Clin Biochem ; 80: 42-47, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32247779

RESUMEN

OBJECTIVES: The performance of delta check rules has been considered to be dependent on the biological variation characteristics of the analyte of interest. The assumed relationships have not been formally studied. The mathematical relationship between biological variation and delta check rules is explored in this study. DESIGN AND METHODS: From the mathematical model for absolute difference delta check, the threshold for specificity and sensitivity are observed to be normalized differently. For specificity, the threshold is normalized by the within-subject biological variation (expressed as a coefficient of variation, CVi), whereas for sensitivity the threshold is normalized by the between-subject biological variation (expressed as a coefficient of variation, CVg). This highlights the different roles the two biological variations play in affecting the absolute difference distribution for correct and switched patient samples. Analogous to absolute difference delta checks, for relative difference delta checks, the expressions for specificity and sensitivity are scaled by CVi and CVg, respectively. However, the expressions are independent of µg(the average of the population). RESULTS: A comparison between the mathematical model and empirical/ historical laboratory data obtained from patients was conducted for both absolute and relative difference delta checks. In general it was found that the specificity obtained from the historical laboratory data was less than the model predicted values, while on the other hand, good correspondence was obtained between the experimental sensitivity and predicted sensitivity. CONCLUSIONS: The difference in within-subject biological variation in different patients may contribute to the observed discrepancy in predicted and empirical delta check performance.