Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Ophthalmology ; 129(2): 161-170, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34474070

RESUMEN

PURPOSE: To investigate the effect of systemic arterial blood pressure (BP) on rates of progressive structural damage over time in glaucoma. DESIGN: Retrospective cohort study. PARTICIPANTS: A total of 7501 eyes of 3976 subjects with glaucoma or suspected of glaucoma followed over time from the Duke Glaucoma Registry. METHODS: Linear mixed models were used to investigate the effects of BP on the rates of retinal nerve fiber layer (RNFL) loss from spectral-domain OCT (SD-OCT) over time. Models were adjusted for intraocular pressure (IOP), gender, race, diagnosis, central corneal thickness (CCT), follow-up time, and baseline disease severity. MAIN OUTCOME MEASURE: Effect of mean arterial pressure (MAP), systolic arterial pressure (SAP), and diastolic arterial pressure (DAP) on rates of RNFL loss over time. RESULTS: A total of 157 291 BP visits, 45 408 IOP visits, and 30 238 SD-OCT visits were included. Mean rate of RNFL change was -0.70 µm/year (95% confidence interval, -0.72 to -0.67 µm/year). In univariable models, MAP, SAP, and DAP during follow-up were not significantly associated with rates of RNFL loss. However, when adjusted for mean IOP during follow-up, each 10 mmHg reduction in mean MAP (-0.06 µm/year; P = 0.007) and mean DAP (-0.08 µm/year; P < 0.001) but not SAP (-0.01 µm/year; P = 0.355) was associated with significantly faster rates of RNFL thickness change over time. The effect of the arterial pressure metrics remained significant after additional adjustment for baseline age, diagnosis, sex, race, follow-up time, disease severity, and corneal thickness. CONCLUSIONS: When adjusted for IOP, lower MAP and DAP during follow-up were significantly associated with faster rates of RNFL loss, suggesting that levels of systemic BP may be a significant factor in glaucoma progression.


Asunto(s)
Presión Sanguínea/fisiología , Glaucoma/diagnóstico , Glaucoma/fisiopatología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Presión Arterial/fisiología , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Fibras Nerviosas/patología , Hipertensión Ocular/fisiopatología , Sistema de Registros , Células Ganglionares de la Retina/patología , Estudios Retrospectivos , Tomografía de Coherencia Óptica , Tonometría Ocular
2.
Curr Opin Ophthalmol ; 32(2): 92-97, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33443958

RESUMEN

PURPOSE OF REVIEW: Perimetry remains important for the diagnosis and management of glaucoma despite advances in imaging technology. The purpose of this review is to describe advances in the acquisition and analysis of visual field data and highlight novel techniques for performing perimetry. RECENT FINDINGS: Studies have focused on improving the detection of patients at highest risk of severe vision loss and the development of innovative testing strategies that allow for more frequent testing. Artificial intelligence has been utilized in research settings to improve detection and characterization of glaucomatous field damage. Furthermore, tablet-based strategies and virtual reality headsets show promise for glaucoma screening and remote monitoring of patients with glaucoma. SUMMARY: New testing strategies and research findings have improved our ability to identify patients with both paracentral and mid-peripheral visual field progression. New strategies have the potential to make visual field testing more efficient, reliable and accessible for patients with glaucoma.


Asunto(s)
Glaucoma/diagnóstico , Trastornos de la Visión/diagnóstico , Pruebas del Campo Visual/métodos , Campos Visuales/fisiología , Inteligencia Artificial , Progresión de la Enfermedad , Humanos , Trastornos de la Visión/fisiopatología
3.
Retina ; 39(1): 69-78, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29135802

RESUMEN

PURPOSE: Compare changes in retinal nerve fiber layer (RNFL) thickness between eyes assigned to intravitreous ranibizumab or panretinal photocoagulation and assess correlations between changes in RNFL and visual field sensitivity and central subfield thickness. METHODS: Eyes with proliferative diabetic retinopathy were randomly assigned to ranibizumab or panretinal photocoagulation. Baseline and annual follow-up spectral domain optical coherence tomography RNFL imaging, optical coherence tomography macular imaging, and automated static perimetry (Humphrey visual field 60-4 algorithm) were performed. RESULTS: One hundred forty-six eyes from 120 participants were analyzed. At 2 years, for the ranibizumab (N = 74) and panretinal photocoagulation (N = 66) groups, respectively, mean change in average RNFL thickness was -10.9 ± 11.7 µm and -4.3 ± 11.6 µm (difference, -4.9 µm; 95% confidence interval [-7.2 µm to -2.6 µm]; P < 0.001); the correlation between change in RNFL thickness and 60-4 Humphrey visual field mean deviation was -0.27 (P = 0.07) and +0.33 (P = 0.035); the correlation between change in RNFL thickness and central subfield thickness was +0.63 (P < 0.001) and +0.34 (P = 0.005), respectively. CONCLUSION: At 2 years, eyes treated with ranibizumab had greater RNFL thinning than eyes treated with panretinal photocoagulation. Correlations between changes in RNFL thickness, visual field, and central subfield thickness suggest that the decrease in RNFL thickness with ranibizumab is likely due to decreased edema rather than loss of axons.


Asunto(s)
Retinopatía Diabética/terapia , Coagulación con Láser/métodos , Fibras Nerviosas/patología , Ranibizumab/administración & dosificación , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica/métodos , Campos Visuales/fisiología , Adulto , Inhibidores de la Angiogénesis/administración & dosificación , Retinopatía Diabética/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Disco Óptico/patología , Estudios Retrospectivos , Resultado del Tratamiento , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Agudeza Visual
4.
Ophthalmology ; 125(11): 1741-1756, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30007591

RESUMEN

In an elegant example of bench-to-bedside research, a hypothesis that cells in the outflow pathway actively regulate conventional outflow resistance was proposed in the 1990s and systematically pursued, exposing novel cellular and molecular mechanisms of intraocular pressure (IOP) regulation. The critical discovery that pharmacologic manipulation of the cytoskeleton of outflow pathway cells decreased outflow resistance placed a spotlight on the Rho kinase pathway that was known to regulate the cytoskeleton. Ultimately, a search for Rho kinase inhibitors led to the discovery of several molecules of therapeutic interest, leaving us today with 2 new ocular hypotensive agents approved for clinical use: ripasudil in Japan and netarsudil in the United States. These represent members of the first new class of clinically useful ocular hypotensive agents since the US Food and Drug Administration approval of latanoprost in 1996. The development of Rho kinase inhibitors as a class of medications to lower IOP in patients with glaucoma and ocular hypertension represents a triumph in translational research. Rho kinase inhibitors are effective alone or when combined with other known ocular hypotensive medications. They also offer the possibility of neuroprotective activity, a favorable impact on ocular blood flow, and even an antifibrotic effect that may prove useful in conventional glaucoma surgery. Local adverse effects, however, including conjunctival hyperemia, subconjunctival hemorrhages, and cornea verticillata, are common. Development of Rho kinase inhibitors targeted to the cells of the outflow pathway and the retina may allow these agents to have even greater clinical impact. The objectives of this review are to describe the basic science underlying the development of Rho kinase inhibitors as a therapy to lower IOP and to summarize the results of the clinical studies reported to date. The neuroprotective and vasoactive properties of Rho kinase inhibitors, as well as the antifibrotic properties, of these agents are reviewed in the context of their possible role in the medical and surgical treatment of glaucoma.


Asunto(s)
Benzoatos/uso terapéutico , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Presión Intraocular/efectos de los fármacos , Isoquinolinas/uso terapéutico , Sulfonamidas/uso terapéutico , beta-Alanina/análogos & derivados , Quinasas Asociadas a rho/antagonistas & inhibidores , Antihipertensivos/uso terapéutico , Humor Acuoso/fisiología , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Hipertensión Ocular/tratamiento farmacológico , Hipertensión Ocular/fisiopatología , Investigación Biomédica Traslacional , beta-Alanina/uso terapéutico
7.
BMC Ophthalmol ; 16(1): 217, 2016 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-28034308

RESUMEN

BACKGROUND: Antifibrotic agents are commonly utilized to enhance the success rates of trabeculectomy. Novel approaches to further improve success rates and reduce the risks of complications are needed. The purpose of this study was to compare intraocular pressure (IOP)-lowering efficacy and safety of trabeculectomy or combined phacoemulsification and trabeculectomy with mitomycin-C (MMC) vs. Collagen Matrix (CM). METHODS: A prospective, multicenter, randomized controlled trial was performed. Ninety-five eyes of 94 patients with uncontrolled glaucoma despite medical therapy, without previous incisional glaucoma surgery underwent trabeculectomy (85 eyes) or combined phacoemulsification and trabeculectomy (10 eyes) and were randomized to MMC or CM. One eye of each subject was analyzed. Patients were followed for 24 months. The criteria for complete success were IOP >5 and ≤21 mmHg with at least a 20% reduction below medicated baseline without additional glaucoma surgery or medications. The main outcome measures were complete success rates at 24 months with Kaplan-Meier analysis and incidence of adverse events. RESULTS: The baseline IOPs were 20.4 ± 6.0 mmHg and 21.2 ± 6.1 (mean ± standard deviation, p = 0.49) on 3.2 ± 1.1 and 3.1 ± 1.0 medications (p = 0.53) compared to 11.8 ± 5.2 and 12.8 ± 3.7 (p = 0.36) on 0.5 ± 0.8 and 0.6 ± 1.0 medications (p = 0.63) at 2 years in the MMC and CM groups, respectively. Kaplan-Meier analysis demonstrated complete success rates were similar in both groups at 24 months: 38.4 ± 7.6% with MMC and 56.2 ± 7.9% with CM (mean ± standard error, p = 0.112, log rank test); however, a significantly higher incidence of failure due to persistent hypotony was observed with MMC (p = 0.002). CONCLUSIONS: Use of the CM implant at the time of trabeculectomy or combined phacoemulsification and trabeculectomy is associated with similar complete success rates compared to adjunctive MMC; however, the risk of persistent hypotony is higher with MMC. TRIAL REGISTRATION: ClinicalTrials.gov registration number NCT01440751 . Registered 9/14/11.


Asunto(s)
Antifibrinolíticos/uso terapéutico , Colágeno/uso terapéutico , Glaucoma/cirugía , Mitomicina/uso terapéutico , Facoemulsificación , Trabeculectomía/métodos , Anciano , Antihipertensivos/uso terapéutico , Terapia Combinada/métodos , Femenino , Glaucoma/tratamiento farmacológico , Glaucoma/fisiopatología , Humanos , Presión Intraocular/fisiología , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Trabeculectomía/efectos adversos
8.
Curr Opin Ophthalmol ; 26(2): 116-20, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25594765

RESUMEN

PURPOSE OF REVIEW: Prostaglandin analogs (PGAs) are the most widely used ocular hypotensive medications. Half of the patients with glaucoma and 40% of patients with ocular hypertension require more than one medication to sufficiently lower their intraocular pressures (IOPs). Therefore, it is important to understand the varying efficacy of adjunctive therapies currently available for use in combination with PGAs. RECENT FINDINGS: The IOP-lowering efficacy and safety profiles of various adjunctive treatments continue to be better elucidated, including the nocturnal IOP-lowering efficacy of various medication classes and laser trabeculoplasty. SUMMARY: For patients already on a PGA, the mean diurnal IOP-lowering achieved with the addition of an alpha2 adrenergic agonist, a beta adrenergic antagonist, or a topical carbonic anhydrase inhibitor is similar, whereas the side-effect profiles, nocturnal IOP-lowering efficacy, and trough IOP-lowering effects vary. Laser trabeculoplasty is also an effective means of further lowering the IOP in patients on a PGA.


Asunto(s)
Agonistas de Receptores Adrenérgicos alfa 2/uso terapéutico , Antagonistas Adrenérgicos beta/uso terapéutico , Antihipertensivos/uso terapéutico , Inhibidores de Anhidrasa Carbónica/uso terapéutico , Glaucoma/tratamiento farmacológico , Presión Intraocular/efectos de los fármacos , Prostaglandinas Sintéticas/uso terapéutico , Combinación de Medicamentos , Glaucoma/fisiopatología , Humanos , Hipertensión Ocular/tratamiento farmacológico
9.
J Glaucoma ; 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38976304

RESUMEN

PRECIS: Among 1,861 adults with ocular hypertension or mild or moderate primary open-angle glaucoma, those with Medicaid or no insurance had a statistically significantly lower likelihood of receiving laser trabeculoplasty compared with those with other insurance. PURPOSE: To determine whether social determinants of health are associated with undergoing treatment with laser trabeculoplasty (LTP) among individuals with ocular hypertension (OHT) or mild or moderate primary open angle glaucoma (POAG). METHODS: In this cross-sectional study, we included patients with OHT or mild or moderate POAG from the National Institutes of Health All of Us Research Program, a diverse US nationwide dataset. Logistic regression was performed to study the association between LTP treatment status and seven covariates (diagnosis severity, age, gender, race/ethnicity, income, insurance status, and education). RESULTS: 1,861 subjects were included (median age of 72 y). In univariable logistic regression, diagnosis severity, older age, higher income, and insurance (non-Medicaid) were associated with LTP treatment. On multivariable logistic regression models, those with mild POAG (OR, 3.49; 95% CI [2.12-5.87]) and moderate POAG (OR, 7.15 [4.49-11.8]) were still more likely than OHT patients to have received LTP. Moreover, compared with participants with Medicaid or no insurance, participants with other insurance (e.g. employer provided, Medicare) were still more likely to have received LTP (OR, 2.24 [1.08-5.29]). There was no significant difference in the LTP treatment likelihood based on race/ethnicity. CONCLUSIONS: After controlling for confounders, the likelihood of receiving LTP appears to be driven primarily by insurance rather than income or race/ethnicity. Potential reasons for decreased utilization of LTP among Medicaid patients include higher rates of declining the procedure, or LTP may have been offered less frequently due to Medicaid's lower levels of reimbursement and longer reimbursement delays.

10.
Ophthalmol Glaucoma ; 7(1): 37-46, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37567499

RESUMEN

PURPOSE: To compare outcomes of early aqueous suppression (EAS) and standard therapy (ST) after Ahmed Glaucoma Valve (AGV) implantation for uveitic glaucoma. DESIGN: Retrospective comparative cohort study. PARTICIPANTS: All patients with uveitic glaucoma underwent AGV implantation from January 2010 to October 2020 at Northwestern Medicine. METHODS: Excluding the first postoperative day 1 (POD1), only eyes with IOP 10-15 mmHg at their first visit with IOP ≥ 10 mmHg were included in the main analysis. Early aqueous suppression (EAS) was defined as initiation of ocular hypotensive therapy when IOP was first 10-15 mmHg. Standard therapy was initiation of therapy at any later time. Failure was defined as IOP > 21 mmHg, < 5 mmHg, or < 20% reduction in IOP from baseline after 3 months, for 2 consecutive study visits. Hypotony was defined as IOP ≤ 5 mmHg for ≥ 2 visits. Hypertensive phase was defined as IOP > 21 mmHg for 2 consecutive visits in the first 3 months. MAIN OUTCOME MEASURES: Proportion achieving overall success; incidence of hypotony and hypertensive phase. RESULTS: Twenty-eight eyes of 26 patients were in the EAS group and 20 eyes of 19 patients were in the ST group, with a mean follow-up of 17.7 and 28.2 months, respectively. Baseline IOP was similar in the EAS (31.2 ± 10.1 mmHg) and ST (34.6 ± 12.2 mmHg) groups; P = 0.18. Final IOP was lower in the EAS group (12.9 ± 4.6 mmHg) than the ST group (16.4 ± 5.7 mmHg; P = 0.02) on 2.6 ± 0.9 medications in the EAS group and 1.8 ± 1.5 in the ST group (P = 0.07). Overall success was achieved in 87% of EAS eyes and 74% of ST eyes (P = 0.43). There were no statistically significant differences in the occurrence of additional glaucoma surgery (4% for EAS, 20% for ST; P = 0.11), hypotony (7% for EAS, 0% for ST; P = 0.50), or hypertensive phase (4% for EAS, 21% for ST; P = 0.09). CONCLUSIONS: EAS was associated with a lower final IOP after AGV in uveitic glaucoma eyes; however, more medications were in use at the final visit. No statistically significant differences in overall success or the incidence of adverse events were observed. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma , Humanos , Estudios Retrospectivos , Estudios de Cohortes , Presión Intraocular , Glaucoma/etiología , Glaucoma/cirugía , Implantes de Drenaje de Glaucoma/efectos adversos
11.
Ophthalmol Glaucoma ; 7(4): 345-351, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38548133

RESUMEN

PURPOSE: To describe the incidence, risk factors, clinical characteristics, and long-term outcomes of a hypertensive phase (HP) after glaucoma drainage device (GDD) implantation. DESIGN: Retrospective cohort study. PARTICIPANTS: Eyes that underwent implantation of their first GDD from January 2010 to October 2020 at a tertiary care center. METHODS: Hypertensive phase was defined as intraocular pressure (IOP) >21 mmHg occurring at 2 consecutive visits in the first 90 days after the date of surgery for Ahmed Glaucoma Valve (AGV) or in the first 90 days after tube opening for Baerveldt Glaucoma Implant (BGI). Generalized estimating equations and Fisher exact tests were used to evaluate risk factors for HP and risk factors for failure of GDD surgery after occurrence of a HP. MAIN OUTCOME MEASURES: Incidence and risk factors for HP. Overall surgical success rates, defined as the absence of failure criteria: IOP >21 mmHg, ≤5 mmHg, or <20% reduction below baseline IOP after 3 months for 2 consecutive visits, with or without adjunctive ocular hypotensive therapy; additional glaucoma surgery; or loss of light perception. RESULTS: Among 419 eyes of 360 patients that underwent GDD implantation, 42 (10.0%) eyes developed HP. Onset of HP was 20.8 ± 10.5 days after AGV and 11.7 ± 20.3 days from the date of tube opening after BGI. Mean IOP during HP was 26.5 ± 3.2 mmHg with peak IOP of 30.0 ± 5.9 mmHg. Median follow-up duration was 21.5 months after onset of HP. Younger age and neovascular glaucoma were significant risk factors for HP occurrence in a multivariable model. Resolution of HP occurred in 32 eyes (76.2%) after a mean duration of 48.0 ± 53.0 days. Additional surgery with a second GDD or cyclophotocoagulation was performed for 12 eyes (28.6%). The overall success rate among eyes with a HP was 52.6% at 2 years, which was significantly lower than that observed among control eyes that did not experience HP (76.3%), P < 0.01. CONCLUSIONS: The incidence of HP was 10.0%. Younger age and neovascular glaucoma were significant risk factors for HP in the multivariable model. The risk of surgical failure after HP is significantly higher compared to eyes that did not experience HP. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Implantes de Drenaje de Glaucoma , Presión Intraocular , Humanos , Masculino , Femenino , Incidencia , Estudios Retrospectivos , Presión Intraocular/fisiología , Persona de Mediana Edad , Anciano , Estudios de Seguimiento , Factores de Riesgo , Glaucoma/cirugía , Glaucoma/fisiopatología , Hipertensión Ocular/fisiopatología , Hipertensión Ocular/etiología , Hipertensión Ocular/epidemiología , Complicaciones Posoperatorias/epidemiología , Agudeza Visual , Adulto , Tonometría Ocular
12.
J Glaucoma ; 33(8): 607-611, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38546238

RESUMEN

PRCIS: Intraluminal 3-0 Supramid stent placement can be an effective long-term solution for hypotony after glaucoma drainage device surgery. This procedure may obviate the need for conjunctival dissection. In some cases, additional procedures are required. PURPOSE: To describe the utility of implantation of a multifilament polyamide suture (Supramid) in the tube lumen to reverse hypotony after glaucoma drainage device (GDD) surgery. PATIENTS: Patients who underwent tube revision with intraluminal placement of a 3-0 Supramid stent, with or without external ligature, to manage hypotony following GDD surgery between January 2010 and October 2020. METHODS: Resolution of hypotony was defined as IOP >5 mm Hg and the absence of hypotony-related structural abnormalities. Overall success was the absence of failure criteria (IOP ≤5 mm Hg, >21 mm Hg, or <20% reduction below baseline IOP after 3 months for 2 consecutive study visits; additional glaucoma surgery; or loss of light perception), with or without adjunctive ocular hypotensive therapy. RESULTS: Nine eyes of 9 patients underwent placement of a 3-0 Supramid stent with a resolution of hypotony in all eyes with a mean follow-up duration of 33.3 ±24.0 months. Overall success was achieved in 7 of 9 eyes. Four eyes required intervention after stent placement: 1 eye required selective laser trabeculoplasty followed by replacement of the original stent with a shorter 3-0 Supramid suture and external ligature; 1 eye underwent revision for tube exposure; and 2 eyes underwent laser suture lysis to release an external suture ligature. CONCLUSIONS: In cases of hypotony after GDD, particularly when it is desirable to reduce the extent of additional conjunctival dissection, intraluminal placement of a 3-0 Supramid stent via an intracameral approach can be an effective long-term solution. Postoperative adjustments were required in many cases.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma , Presión Intraocular , Hipotensión Ocular , Stents , Técnicas de Sutura , Humanos , Hipotensión Ocular/etiología , Hipotensión Ocular/cirugía , Hipotensión Ocular/fisiopatología , Presión Intraocular/fisiología , Femenino , Masculino , Anciano , Persona de Mediana Edad , Estudios Retrospectivos , Glaucoma/cirugía , Glaucoma/fisiopatología , Suturas , Reoperación , Tonometría Ocular , Complicaciones Posoperatorias , Estudios de Seguimiento , Anciano de 80 o más Años , Adulto
13.
J Glaucoma ; 33(4): 246-253, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38245813

RESUMEN

PRCIS: A deep learning model trained on macular OCT imaging studies detected clinically significant functional glaucoma progression and was also able to predict future progression. OBJECTIVE: To use macular optical coherence tomography (OCT) imaging to predict the future and detect concurrent visual field progression, respectively, using deep learning. DESIGN: A retrospective cohort study. SUBJECTS: A pretraining data set was comprised of 7,702,201 B-scan images from 151,389 macular OCT studies. The progression detection task included 3902 macular OCT imaging studies from 1534 eyes of 828 patients with glaucoma, and the progression prediction task included 1346 macular OCT studies from 1205 eyes of 784. METHODS: A novel deep learning method was developed to detect glaucoma progression and predict future progression using macular OCT, based on self-supervised pretraining of a vision transformer (ViT) model on a large, unlabeled data set of OCT images. Glaucoma progression was defined as a mean deviation (MD) rate of change of ≤ -0.5 dB/year over 5 consecutive Humphrey visual field tests, and rapid progression was defined as MD change ≤ -1 dB/year. MAIN OUTCOME MEASURES: Diagnostic performance of the ViT model for prediction of future visual field progression and detection of concurrent visual field progression using area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. RESULTS: The model distinguished stable eyes from progressing eyes, achieving an AUC of 0.90 (95% CI, 0.88-0.91). Rapid progression was detected with an AUC of 0.92 (95% CI, 0.91-0.93). The model also demonstrated high predictive ability for forecasting future glaucoma progression, with an AUC of 0.85 (95% CI 0.83-0.87). Rapid progression was predicted with an AUC of 0.84 (95% CI 0.81-0.86). CONCLUSIONS: A deep learning model detected clinically significant functional glaucoma progression using macular OCT imaging studies and was also able to predict future progression. Early identification of patients undergoing glaucoma progression or at high risk for future progression may aid in clinical decision-making.


Asunto(s)
Aprendizaje Profundo , Glaucoma , Humanos , Campos Visuales , Tomografía de Coherencia Óptica/métodos , Estudios Retrospectivos , Presión Intraocular , Células Ganglionares de la Retina , Glaucoma/diagnóstico , Pruebas del Campo Visual/métodos
14.
Curr Opin Ophthalmol ; 24(2): 150-61, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23328662

RESUMEN

PURPOSE OF REVIEW: With the rapid adoption of spectral domain optical coherence tomography (SDOCT) in clinical practice and the recent advances in software technology, there is a need for a review of the literature on glaucoma detection and progression analysis algorithms designed for the commercially available instruments. RECENT FINDINGS: Peripapillary retinal nerve fiber layer (RNFL) thickness and macular thickness, including segmental macular thickness calculation algorithms, have been demonstrated to be repeatable and reproducible, and have a high degree of diagnostic sensitivity and specificity in discriminating between healthy and glaucomatous eyes across the glaucoma continuum. Newer software capabilities such as glaucoma progression detection algorithms provide an objective analysis of longitudinally obtained structural data that enhances our ability to detect glaucomatous progression. RNFL measurements obtained with SDOCT appear more sensitive than time domain OCT (TDOCT) for glaucoma progression detection; however, agreement with the assessments of visual field progression is poor. SUMMARY: Over the last few years, several studies have been performed to assess the diagnostic performance of SDOCT structural imaging and its validity in assessing glaucoma progression. Most evidence suggests that SDOCT performs similarly to TDOCT for glaucoma diagnosis; however, SDOCT may be superior for the detection of early stage disease. With respect to progression detection, SDOCT represents an important technological advance because of its improved resolution and repeatability. Advancements in RNFL thickness quantification, segmental macular thickness calculation and progression detection algorithms, when used correctly, may help to improve our ability to diagnose and manage glaucoma.


Asunto(s)
Glaucoma/diagnóstico , Mácula Lútea/patología , Fibras Nerviosas/patología , Enfermedades del Nervio Óptico/diagnóstico , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica , Progresión de la Enfermedad , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
J Glaucoma ; 32(2): 139-144, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36223324

RESUMEN

PRCIS: Among 7846 adults with self-reported glaucoma, low health literacy (LHL) was associated with fewer outpatient ophthalmological follow-up visits, utilization of a greater number of ocular hypotensive medication classes, and higher costs for glaucoma medications. PURPOSE: Previous studies found LHL is associated with increased difficulty with treatment adherence among adults with glaucoma, which can lead to poor outcomes. This study examined patterns of glaucoma health care utilization associated with LHL. METHODS: We analyzed 7846 adults with self-reported glaucoma enrolled in the 1996-2017 Medical Expenditure Panel Survey. Adult glaucoma patients with LHL (defined by National Assessment of Adult Literacy score <226) were the compared with those with high health literacy. Multivariable regression models were constructed to examine the association of LHL with number of outpatient glaucoma visits, prescription medications, polypharmacy (≥2 ocular hypotensive classes prescribed), and associated costs. RESULTS: Self-reported glaucoma diagnosis was associated with higher rates of LHL [23.9% vs. 9.7%, odds ratio (95% CI): 2.43 (2.25-2.62), P <0.0001]. Among those with glaucoma, LHL was associated with fewer glaucoma outpatient visits [risk ratio: 0.94 (0.89-0.99), P =0.02] and the use of a greater number of ocular hypotensive medications [1.06 (1.01-1.12), P =0.03]. Moreover, those with LHL had higher health care spending on prescription medications [mean: $556.40 vs. $471.87, ß (95% CI): $57.05 ($30.22-$83.87)]. Adult glaucoma patients with LHL were also more likely to have polypharmacy [odds ratio (95% CI): 1.26 (1.01-1.59)]. CONCLUSION: LHL was more prevalent in patients with glaucoma, compared with those without. Glaucoma patients with LHL were prescribed more medications and had higher medication costs, however, they had fewer outpatient glaucoma visits. Improved glaucoma patient education to address LHL is needed, in addition to studies to understand the impact of these findings on treatment outcomes.


Asunto(s)
Glaucoma , Alfabetización en Salud , Medicamentos bajo Prescripción , Adulto , Humanos , Presión Intraocular , Aceptación de la Atención de Salud , Costos y Análisis de Costo , Glaucoma/tratamiento farmacológico , Antihipertensivos/uso terapéutico
16.
J Glaucoma ; 32(3): 145-150, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36848258

RESUMEN

PRCIS: The cost of cyclophotocoagulation is less than the cost of a second glaucoma drainage device. PURPOSE: To compare the total direct costs of implantation of a second glaucoma drainage device (SGDD) with transscleral cyclophotocoagulation (CPC) for patients with inadequately controlled intraocular pressure (IOP) reduction, despite the presence of a preexisting glaucoma drainage device in the ASSISTS clinical trial. METHODS: We compared the total direct cost per patient, including the initial study procedure, medications, additional procedures, and clinic visits during the study period. The relative costs for each procedure during the 90-day global period and the entire study period were compared. The cost of the procedure, including facility fees and anesthesia costs, were determined using the 2021 Medicare fee schedule. Average wholesale prices for self-administered medications were obtained from AmerisourceBergen.com. The Wilcoxon rank sum test was used to compare costs between procedures. RESULTS: Forty-two eyes of 42 participants were randomized to SGDD (n=22) or CPC (n=20). One CPC eye was lost to follow-up after initial treatment and was excluded. The mean (±SD, median) duration of follow-up was 17.1 (±12.8, 11.7) months and 20.3 (±11.4, 15.1) months for SGDD and CPC, respectively ( P =0.42, 2 sample t test). The mean total direct costs (±SD, median) per patient during the study period were $8790 (±$3421, $6805 for the SGDD group) and $4090 (±$1424, $3566) for the CPC group ( P <0.001). Similarly, the global period cost was higher in the SGDD group than in the CPC group [$6173 (±$830, $5861) vs. $2569 (±$652, $2628); P <0.001]. The monthly cost after the 90-day global period was $215 (±$314, $100) for SGDD and $103 (±$74, $86) for CPC ( P =0.31). The cost of IOP-lowering medications was not significantly different between groups during the global period ( P =0.19) or after the global period ( P =0.23). CONCLUSION: The total direct cost in the SGDD group was more than double that in the CPC group, driven largely by the cost of the study procedure. The costs of IOP-lowering medications were not significantly different between groups. When considering treatment options for patients with a failed primary GDD, clinicians should be aware of differences in costs between these treatment strategies.


Asunto(s)
Implantes de Drenaje de Glaucoma , Hipotensión Ocular , Estados Unidos , Humanos , Anciano , Medicare , Presión Intraocular , Ojo , Instituciones de Atención Ambulatoria
18.
Ophthalmology ; 119(10): 2028-32, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22683061

RESUMEN

OBJECTIVE: To explore trends in the prevalence of self-reported visual impairment in the noninstitutionalized adult US population during the 27-year period from 1984 to 2010. DESIGN: Data obtained from the National Health Interview Survey (NHIS) and the Survey of Income and Program Participation (SIPP) were used to analyze trends in the prevalence of self-reported visual impairment in the United States. PARTICIPANTS: Representative, population-based samples of between 45 000 and 92 000 adults (NHIS) and between 37 000 and 71 000 adults (SIPP) during each year of data collection. METHODS: Survey results were age-adjusted to a standard (2010) population. Sampling weights were used throughout the analysis using strata and primary sampling unit variables provided in the public use datasets to appropriately take into account the complex design of the surveys. The statistical significance of trends was estimated by computing the difference in chi-squares of a fit to a linear trendline and a fit without a trend. MAIN OUTCOME MEASURES: The trends and percent change in the prevalence of visual impairment from 1984 to 1996 and from 1997 to 2010 for NHIS and 1984 to 2010 for SIPP. RESULTS: On the basis of NHIS data, the prevalence of activity-limiting visual impairment among persons aged ≥65 years declined by 51.7% (P < 0.001), from 3.5% in 1984 to 1.7% in 1996, and by 45.8% (P < 0.001), from 3.1% in 1997 to 1.7% in 2010. On the basis of SIPP data, the prevalence of functional visual impairment in the same age category declined by 58.3% (P < 0.001), from 23.3% in 1984 to 9.7% in 2010, whereas the prevalence of severe functional impairment declined by 47.1% (P < 0.001), from 5.1% to 2.7%. CONCLUSIONS: There was a marked reduction in the prevalence of self-reported visual impairment in the noninstitutionalized adult US population during the period from 1984 to 2010.


Asunto(s)
Ceguera/epidemiología , Baja Visión/epidemiología , Personas con Daño Visual/estadística & datos numéricos , Actividades Cotidianas , Adolescente , Adulto , Anciano , Indicadores de Salud , Encuestas Epidemiológicas/estadística & datos numéricos , Humanos , Persona de Mediana Edad , Prevalencia , Autoinforme , Estados Unidos/epidemiología , Agudeza Visual/fisiología , Adulto Joven
19.
Ophthalmology ; 119(3): 468-73, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22137043

RESUMEN

PURPOSE: To compare the results of Glaucoma Progression Analysis (GPA, Carl Zeiss Meditec, Dublin, CA) to subjective expert consensus in the detection of glaucomatous visual field progression. DESIGN: Retrospective, observational case series. PARTICIPANTS: We included 100 eyes of 83 glaucoma patients. METHODS: Five serial Humphrey visual fields from 100 eyes of 83 glaucoma patients were evaluated by 5 masked glaucoma subspecialists for determination of progression. Four months later, with a randomly reordered patient sequence, the same visual field series were reevaluated by the same graders, at which time they had access to the Glaucoma Progression Analysis (GPA) printout. MAIN OUTCOME MEASURES: The level of agreement between majority expert consensus and GPA, both before and after access to GPA data, was assessed using kappa statistics. RESULTS: On initial review and on reevaluation with access to the GPA printout, the level of agreement between majority expert consensus and GPA was fair (kappa = 0.52, 95% confidence interval [CI], 0.35-0.69 and kappa = 0.62; 95% CI, 0.46-0.78, respectively). Expert consensus was more likely to classify a series of fields as showing progression than was GPA (P ≤ 0.002). There was good agreement between expert consensus on initial review and reevaluation 4 months later (kappa = 0.77; 95% CI, 0.65-0.90). CONCLUSIONS: The level of agreement between majority expert consensus of subjective determination of visual field progression and GPA is fair. In cases of disagreement with GPA, the expert consensus classification was usually progression. Access to the results of GPA did not significantly change the level of agreement between expert consensus and the GPA result; however, expert consensus did change in 11 of 100 cases.


Asunto(s)
Sistemas Especialistas , Glaucoma de Ángulo Abierto/diagnóstico , Oftalmología , Trastornos de la Visión/diagnóstico , Campos Visuales , Progresión de la Enfermedad , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Presión Intraocular , Hipertensión Ocular/diagnóstico , Hipertensión Ocular/fisiopatología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Programas Informáticos , Tonometría Ocular , Trastornos de la Visión/fisiopatología , Pruebas del Campo Visual
20.
J Glaucoma ; 31(6): 438-442, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35283441

RESUMEN

PRCIS: We assessed the readability of online glaucoma patient education materials using seven validated instruments. Overall, glaucoma materials were written at a 10th to 11th grade level, above the recommended seventh grade reading level. PURPOSE: Online health information is increasingly used by patients, yet previous studies show online patient education materials are often difficult to understand. As such, the American Medical Association recommends that patient education materials are written at or below a seventh grade reading level. This study aimed to assess the readability of online glaucoma patient education materials. METHODS: Glaucoma was entered into the Google search engine, and the first 30 search results were assessed for readability using seven validated readability instruments. Scientific articles, forums, and dictionary entries were excluded. Single sample t tests were used to assess whether online glaucoma materials were written above the recommended seventh grade level. RESULTS: Overall, glaucoma materials were written at a mean grade level of 10.33 (SD: 2.02). Across 6 grade level readability instruments, these patient education materials were written above the recommended seventh grade reading level (P<0.0001 for all). Glaucoma education materials only on the first page of Google search results were of a similar reading level: mean 10.56 (SD: 2.13). The readability instruments used in this study showed strong consistency. CONCLUSIONS: Glaucoma patient education materials are written above the recommended reading level to promote accessibility of education materials. This may contribute to lower patient engagement, worse clinical outcomes, and greater racial and ethnic disparities in glaucoma management. There is a need for reliable, simple glaucoma information to improve patient outcomes.


Asunto(s)
Glaucoma , Alfabetización en Salud , Comprensión , Alfabetización en Salud/métodos , Humanos , Presión Intraocular , Educación del Paciente como Asunto , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA