Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Bacteriol ; 194(8): 1885-96, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22328665

RESUMEN

Enteropathogenic Escherichia coli (EPEC) continues to be a leading cause of mortality and morbidity in children around the world. Two EPEC genomes have been fully sequenced: those of EPEC O127:H6 strain E2348/69 (United Kingdom, 1969) and EPEC O55:H7 strain CB9615 (Germany, 2003). The O55:H7 serotype is a recent precursor to the virulent enterohemorrhagic E. coli O157:H7. To explore the diversity of O55:H7 and better understand the clonal evolution of O157:H7, we fully sequenced EPEC O55:H7 strain RM12579 (California, 1974), which was collected 1 year before the first U.S. isolate of O157:H7 was identified in California. Phage-related sequences accounted for nearly all differences between the two O55:H7 strains. Additionally, O55:H7 and O157:H7 strains were tested for the presence and insertion sites of Shiga toxin gene (stx)-containing bacteriophages. Analysis of non-phage-associated genes supported core elements of previous O157:H7 stepwise evolutionary models, whereas phage composition and insertion analyses suggested a key refinement. Specifically, the placement and presence of lambda-like bacteriophages (including those containing stx) should not be considered stable evolutionary markers or be required in placing O55:H7 and O157:H7 strains within the stepwise evolutionary models. Additionally, we suggest that a 10.9-kb region (block 172) previously believed unique to O55:H7 strains can be used to identify early O157:H7 strains. Finally, we defined two subsets of O55:H7 strains that share an as-yet-unobserved or extinct common ancestor with O157:H7 strains. Exploration of O55:H7 diversity improved our understanding of the evolution of E. coli O157:H7 and suggested a key revision to accommodate existing and future configurations of stx-containing bacteriophages into current models.


Asunto(s)
Escherichia coli Enteropatógena/genética , Escherichia coli O157/genética , Escherichia coli O157/metabolismo , Toxina Shiga/genética , Bacteriófagos , Cromosomas Bacterianos , Elementos Transponibles de ADN , ADN Bacteriano/genética , Escherichia coli Enteropatógena/clasificación , Regulación Bacteriana de la Expresión Génica/fisiología , Marcadores Genéticos , Variación Genética , Genoma Bacteriano , Datos de Secuencia Molecular , Filogenia , Serotipificación
2.
J AOAC Int ; 95(5): 1495-504, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23175985

RESUMEN

Modern molecular methods offer the advantages of simplicity and short time-to-results compared to traditional culture methods. We describe the validation of a new Real-Time PCR method to detect E. coli O157:H7 in five food matrixes. The complete system consists of the MicroSEQ E. coli O157:H7 Detection Kit, sample preparation (two sample preparation methods, the PrepSEQ Nucleic Acid Extraction Kit and the PrepSEQ Rapid Spin Sample Preparation Kit, were validated), the Applied Biosystems 7500 Fast Real-Time PCR instrument, and RapidFinder Express software. The test method was compared to the U.S. Department of Agriculture Microbiology Laboratory Guidebook 5.04 reference method for detecting E. coli O157:H7 in 25 g and 375 g ground beef and beef trim, and to the ISO 16654 reference method for detecting E. coli O157:H7 in 25 g spinach, orange juice, and apple juice. The MicroSEQ E. coli O157:H7 Detection Kit showed equivalent detection compared to the corresponding reference method based on Mantel-Haenszel Chi-square statistics for all matrixes tested. An independent validation confirmed these findings on ground beef. The MicroSEQ kit detected all 51 E. coli O157:H7 strains tested and showed good discrimination against an exclusivity panel of 30 strains.


Asunto(s)
Escherichia coli O157/aislamiento & purificación , Microbiología de Alimentos/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Programas Informáticos
3.
J AOAC Int ; 95(4): 1074-83, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22970575

RESUMEN

A complete system for real-time PCR detection of Listeria species was validated in five food matrixes and five environmental surfaces, namely, hot dogs, roast beef, lox (smoked salmon), pasteurized whole cow's milk, dry infant formula, stainless steel, plastic cutting board, ceramic tile, rubber sheets, and sealed concrete. The system consists of the MicroSEQ Listeria spp. Detection Kit, two sample preparation kits (PrepSEQ Nucleic Acid Extraction Kit and PrepSEQ Rapid Spin Sample Preparation Kit), the Applied Biosystems 7500 Fast Real-Time PCR instrument, and the RapidFinderTM Express v1.1 Software for data analysis. The test method was compared to the ISO 11290-1 reference method using an unpaired study design. The MicroSEQ Listeria spp. Detection Kit and the ISO 11290-1 reference method showed equivalent detection based on Chi-square analysis for all matrixes except hot dogs. For hot dogs, the MicroSEQ method detected more positives than the reference method for the low- and high-level inoculations, with all of the presumptive positives confirmed by the reference method. An independent validation study confirmed these findings on lox and stainless steel surface. The MicroSEQ kit detected all 50 Listeria strains tested and none of the 31 nontarget bacteria strains.


Asunto(s)
Técnicas de Química Analítica/métodos , Monitoreo del Ambiente/métodos , Contaminación de Alimentos/análisis , Microbiología de Alimentos , Listeria monocytogenes/genética , Listeria/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Animales , Bovinos , Ambiente , Análisis de los Alimentos/métodos , Humanos , Fórmulas Infantiles , Recién Nacido , Carne/microbiología , Leche/microbiología , Juego de Reactivos para Diagnóstico , Reproducibilidad de los Resultados , Especificidad de la Especie
4.
J AOAC Int ; 94(4): 1106-16, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21919345

RESUMEN

Real-time PCR methods for detecting foodborne pathogens offer the advantages of simplicity and quick time-to-results compared to traditional culture methods. In this study, the MicroSEQ real-time PCR system was evaluated for detection of Salmonella spp. in 10 different food matrixes following the AOAC Research Institute's Performance Tested Method validation program. In addition, the performance of the MicroSEQ system was evaluated for the detection of Salmonella in peanut butter as a part of the Emergency Response Validation Program sponsored by the AOAC Research Institute. The system was compared to the ISO 6579 reference method using a paired-study design for detecting Salmonella spp. in raw ground beef, raw chicken, raw shrimp, Brie cheese, shell eggs, cantaloupe, chocolate, black pepper, dry infant formula, and dry pet food. For the peanut butter study, the system was compared to the U.S. Food and Drug Administration's Bacteriological Analytical Manual procedures using an unpaired-study design. No significant difference in performance was observed between the MicroSEQ Salmonella spp. detection system and the corresponding reference methods for all 11 food matrixes. The MicroSEQ system detected all Salmonella strains tested, while showing good discrimination against detection of an exclusivity panel of 30 strains, with high accuracy.


Asunto(s)
Microbiología de Alimentos/métodos , Reacción en Cadena de la Polimerasa/métodos , Salmonella/aislamiento & purificación , Reproducibilidad de los Resultados , Salmonella/clasificación , Sensibilidad y Especificidad , Especificidad de la Especie
5.
J AOAC Int ; 94(5): 1481-9, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22165012

RESUMEN

Increasingly, more food companies are relying on molecular methods, such as PCR, for pathogen detection due to their improved simplicity, sensitivity, and rapid time to results. This report describes the validation of a new Real-Time PCR method to detect Listeria monocytogenes in nine different food matrixes. The complete system consists of the MicroSEQ L. monocytogenes Detection Kit, sample preparation, the Applied Biosystems 7500 Fast Real-Time PCR instrument, and RapidFinder Express software. Two sample preparation methods were validated: the PrepSEQ Nucleic Acid extraction kit and the PrepSEQ Rapid Spin sample preparation kit. The test method was compared to the ISO 11290-1 reference method using an unpaired-study design to detect L. monocytogenes in roast beef, cured bacon, lox (smoked salmon), lettuce, whole cow's milk, dry infant formula, ice cream, salad dressing, and mayonnaise. The MicroSEQ L. monocytogenes Detection Kit and the ISO 11290-1 reference method showed equivalent detection based on Chi-square analysis for all food matrixes when the samples were prepared using either of the two sample preparation methods. An independent validation confirmed these findings on smoked salmon and whole cow's milk. The MicroSEQ kit detected all 50 L. monocytogenes strains tested, and none of the 30 nontargeted bacteria strains.


Asunto(s)
Microbiología de Alimentos/métodos , Listeria monocytogenes/química , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Medios de Cultivo , ADN Bacteriano/análisis , ADN Bacteriano/genética , Productos Lácteos/microbiología , Carne/microbiología , Juego de Reactivos para Diagnóstico , Estándares de Referencia , Programas Informáticos
6.
Front Microbiol ; 11: 627997, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33519788

RESUMEN

The gold standard method for serotyping Escherichia coli has relied on antisera-based typing of the O- and H-antigens, which is labor intensive and often unreliable. In the post-genomic era, sequence-based assays are potentially faster to provide results, could combine O-serogrouping and H-typing in a single test, and could simultaneously screen for the presence of other genetic markers of interest such as virulence factors. Whole genome sequencing is one approach; however, this method has limited multiplexing capabilities, and only a small fraction of the sequence is informative for subtyping or identifying virulence potential. A targeted, sequence-based assay and accompanying software for data analysis would be a great improvement over the currently available methods for serotyping. The purpose of this study was to develop a high-throughput, molecular method for serotyping E. coli by sequencing the genes that are required for production of O- and H-antigens, as well as to develop software for data analysis and serotype identification. To expand the utility of the assay, targets for the virulence factors, Shiga toxins (stx 1, and stx 2) and intimin (eae) were included. To validate the assay, genomic DNA was extracted from O-serogroup and H-type standard strains and from Shiga toxin-producing E. coli, the targeted regions were amplified, and then sequencing libraries were prepared from the amplified products followed by sequencing of the libraries on the Ion S5™ sequencer. The resulting sequence files were analyzed via the SeroType Caller™ software for identification of O-serogroup, H-type, and presence of stx 1 , stx 2, and eae. We successfully identified 169 O-serogroups and 41 H-types. The assay also routinely detected the presence of stx 1a,c,d (3 of 3 strains), stx 2c-e,g (8 of 8 strains), stx 2f (1 strain), and eae (6 of 6 strains). Taken together, the high-throughput, sequence-based method presented here is a reliable alternative to antisera-based serotyping methods for E. coli.

7.
J AOAC Int ; 92(6): 1895-901, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-20166614

RESUMEN

Peanut butter spiked with Salmonella enterica ser. Typhimurium was prepared by an independent laboratory and sent to Applied Biosystems to determine the sensitivity and specificity of the TaqMan Salmonella enterica Detection Kit for detecting Salmonella in peanut butter. The samples were spiked at three levels: five no-spike (0 CFU/25 g); 20 low-spike (0.2 CFU/25 g); and 20 high-spike (2 CFU/25 g). They were coded to create a blind set of 45 samples. The samples were processed based on an unpaired test design that included enrichment in buffered peptone water for the candidate method and lactose broth for the reference method. In the candidate method, a 1 mL aliquot of enriched sample was extracted using PrepMan Ultra Sample Preparation Reagent; the sample was amplified on the Applied Biosystems 7500 real-time PCR system, and analyzed for detection of Salmonella using RapidFinder Version 1.0 software. All samples processed by the candidate method were confirmed by culture according to the U.S. Food and Drug Administration's Bacteriological Analytical Manual procedures. Sensitivity, specificity, and Chi-square analysis were calculated by combining candidate method results with those of the reference method that were collected by the independent laboratory. The TaqMan Salmonella enterica Detection Kit showed 40% sensitivity, 100% specificity, and a Chi-square value equal to 1.52. Chi-square analysis indicated the candidate method and the reference method were comparable. Although the candidate method sensitivity was only 40% when compared with the reference method (unpaired samples), the sensitivity was > 100% when the candidate method results were compared with those of the confirmation method (same sample enrichment).


Asunto(s)
ADN Bacteriano/análisis , Contaminación de Alimentos/análisis , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Salmonella/química , Arachis/microbiología , Medios de Cultivo , Indicadores y Reactivos , Juego de Reactivos para Diagnóstico , Estándares de Referencia , Reproducibilidad de los Resultados , Salmonella enterica/química , Soluciones
8.
Nucleic Acids Res ; 34(5): 1358-68, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16522646

RESUMEN

Homologous recombinational repair (HRR) restores chromatid breaks arising during DNA replication and prevents chromosomal rearrangements that can occur from the misrepair of such breaks. In vertebrates, five Rad51 paralogs are identified that contribute in a nonessential but critical manner to HRR proficiency. We constructed and characterized a knockout of the paralog Rad51D in widely studied CHO cells. The rad51d mutant (clone 51D1) displays sensitivity to a diverse spectrum of induced DNA damage including gamma-rays, ultraviolet (UV)-C radiation, and methyl methanesulfonate (MMS), indicating the broad relevance of HRR to genotoxicity. Spontaneous chromatid breaks/gaps and isochromatid breaks are elevated 3- to 12-fold, but the chromosome number distribution remains unchanged. Most importantly, 51D1 cells exhibit a 12-fold-increased rate of hprt mutation, as well as 4- to 10-fold increased rates of gene amplification at the dhfr and CAD loci, respectively. Xrcc3 irs1SF cells from the same parental CHO line show similarly elevated mutagenesis at these three loci. Collectively, these results confirm the a priori expectation that HRR acts in an error-free manner to repress three classes of genetic alterations (chromosomal aberrations, loss of gene function and increased gene expression), all of which are associated with carcinogenesis.


Asunto(s)
Mutagénesis , Recombinasa Rad51/fisiología , Recombinación Genética , Animales , Células CHO , Supervivencia Celular , Aberraciones Cromosómicas , Cricetinae , Cricetulus , Daño del ADN , Rayos gamma , Amplificación de Genes , Marcación de Gen , Hipoxantina Fosforribosiltransferasa/genética , Recombinasa Rad51/análisis , Recombinasa Rad51/genética
9.
Nucleic Acids Res ; 34(9): 2833-43, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16717288

RESUMEN

In vertebrates, homologous recombinational repair (HRR) requires RAD51 and five RAD51 paralogs (XRCC2, XRCC3, RAD51B, RAD51C and RAD51D) that all contain conserved Walker A and B ATPase motifs. In human RAD51D we examined the requirement for these motifs in interactions with XRCC2 and RAD51C, and for survival of cells in response to DNA interstrand crosslinks (ICLs). Ectopic expression of wild-type human RAD51D or mutants having a non-functional A or B motif was used to test for complementation of a rad51d knockout hamster CHO cell line. Although A-motif mutants complement very efficiently, B-motif mutants do not. Consistent with these results, experiments using the yeast two- and three-hybrid systems show that the interactions between RAD51D and its XRCC2 and RAD51C partners also require a functional RAD51D B motif, but not motif A. Similarly, hamster Xrcc2 is unable to bind to the non-complementing human RAD51D B-motif mutants in co-immunoprecipitation assays. We conclude that a functional Walker B motif, but not A motif, is necessary for RAD51D's interactions with other paralogs and for efficient HRR. We present a model in which ATPase sites are formed in a bipartite manner between RAD51D and other RAD51 paralogs.


Asunto(s)
Adenosina Trifosfatasas/química , Proteínas de Unión al ADN/química , Recombinación Genética , Secuencias de Aminoácidos , Secuencia de Aminoácidos , Animales , Células CHO , Cricetinae , Cricetulus , Daño del ADN , Reparación del ADN , Proteínas de Unión al ADN/genética , Proteínas de Unión al ADN/metabolismo , Prueba de Complementación Genética , Humanos , Inmunoprecipitación , Datos de Secuencia Molecular , Mutación , Recombinasa Rad51/metabolismo , Técnicas del Sistema de Dos Híbridos
10.
DNA Repair (Amst) ; 4(7): 782-92, 2005 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-15951249

RESUMEN

Unrepaired DNA double-strand breaks (DSBs) produced by ionizing radiation (IR) are a major determinant of cell killing. To determine the contribution of DNA repair pathways to the well-established cell cycle variation in IR sensitivity, we compared the radiosensitivity of wild-type CHO cells to mutant lines defective in nonhomologous end joining (NHEJ), homologous recombination repair (HRR), and the Fanconi anemia pathway. Cells were irradiated with IR doses that killed approximately 90% of each asynchronous population, separated into synchronous fractions by centrifugal elutriation, and assayed for survival (colony formation). Wild-type cells had lowest resistance in early G1 and highest resistance in S phase, followed by declining resistance as cells move into G2/M. In contrast, HR-defective cells (xrcc3 mutation) were most resistant in early G1 and became progressively less resistant in S and G2/M, indicating that the S-phase resistance in wild-type cells requires HRR. Cells defective in NHEJ (dna-pk(cs) mutation) were exquisitely sensitive in early G1, most resistant in S phase, and then somewhat less resistant in G2/M. Fancg mutant cells had almost normal IR sensitivity and normal cell cycle dependence, suggesting that Fancg contributes modestly to survival and in a manner that is independent of cell cycle position.


Asunto(s)
Ciclo Celular/fisiología , Daño del ADN , Reparación del ADN/genética , Tolerancia a Radiación/genética , Recombinación Genética/genética , Animales , Células CHO , Cricetinae , Cricetulus , Proteínas de Unión al ADN/deficiencia , Proteínas de Unión al ADN/genética , Proteína del Grupo de Complementación G de la Anemia de Fanconi , Histonas/metabolismo , Mutación , Radiación Ionizante
11.
DNA Repair (Amst) ; 4(1): 11-22, 2005 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-15533833

RESUMEN

The Fanconi anemia (FA) proteins overlap with those of homologous recombination through FANCD1/BRCA2, but the biochemical functions of other FA proteins are largely unknown. By constructing and characterizing a null fancg mutant (KO40) of hamster CHO cells, we show that FancG protects cells against a broad spectrum of genotoxic agents. KO40 is consistently hypersensitive to both alkylating agents that produce monoadducts and those that produce interstrand crosslinks. KO40 cells were no more sensitive to mitomycin C (3x) and diepoxybutane (2x) than to 6-thioguanine (5x), ethylnitrosourea (3x), or methyl methanesulfonate (MMS) (3x). These results contrast with the pattern of selective sensitivity to DNA crosslinking agents seen historically with cell lines from FA patients. The hypersensitivity of KO40 to MMS was not associated with a higher level of initial DNA single-strand breaks; nor was there a defect in removing MNU-induced methyl groups from DNA. Both control and MMS-treated synchronized G1-phase KO40 cells progressed through S phase at a normal rate but showed a lengthening of G2 phase compared with wild type. MMS-treated and untreated early S-phase KO40 cells had increased levels of Rad51 foci compared with wild type. Asynchronous KO40 treated with ionizing radiation (IR) exhibited a normal Rad51 focus response, consistent with KO40 having only slight sensitivity to killing by IR. The plating efficiency and doubling time of KO40 cells were nearly normal, and they showed no increase in spontaneous chromosomal aberrations or sister chromatid exchanges. Collectively, our results do not support a role for FancG during DNA replication that deals specifically with processing DNA crosslinks. Nor do they suggest that the main function of the FA protein "pathway" is to promote efficient homologous recombination. We propose that the primary function of FA proteins is to maintain chromosomal continuity by stabilizing replication forks that encounter nicks, gaps, or replication-blocking lesions.


Asunto(s)
Reparación del ADN , Replicación del ADN/efectos de los fármacos , Proteínas de Unión al ADN/genética , Anemia de Fanconi/metabolismo , Mutación/genética , Animales , Células CHO , Ciclo Celular/efectos de los fármacos , Cricetinae , Cricetulus , Reactivos de Enlaces Cruzados/toxicidad , Citoprotección/genética , Replicación del ADN/fisiología , Proteínas de Unión al ADN/metabolismo , Anemia de Fanconi/genética , Proteína del Grupo de Complementación G de la Anemia de Fanconi , Técnica del Anticuerpo Fluorescente , Marcación de Gen , Metilmetanosulfonato/toxicidad , Mutágenos/toxicidad , Plásmidos/genética , Recombinasa Rad51 , Radiación Ionizante , Transfección
12.
Mutat Res ; 602(1-2): 34-42, 2006 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-17010390

RESUMEN

Fanconi anemia (FA) is a rare cancer predisposition disease caused by mutations in at least 12 genes encoding proteins that cooperate to maintain genomic integrity. Variants of FA genes, including FANCG, have been identified in human population screening, but their potential reduction in protein function and role in cancer susceptibility is unclear. To test for possible dysfunction, we constructed plasmids containing four FANCG polymorphisms found in the human population and introduced them in the Fancg-deficient (fancg) KO40 line derived from AA8 hamster CHO cells. Expression of wild-type human FANCG provided fancg cells with complete phenotypic correction as assessed by resistance to the DNA crosslinking agent mitomycin C (MMC), thus providing a sensitive test for detecting the degree of complementation activity for the FANCG variants. We found that all four variants conferred levels of mitomycin C resistance as well as restoration of monoubiquitination of Fancd2, a key indicator of a functional FA protein pathway, similar to those observed in wild-type transfectants. Under the same conditions, the L71P amino acid substitution mutant, identified in an FA patient, gave no complementation. Using this novel system for determining FANCG functionality, we detect no decrement in function of the human FANCG polymorphic variants examined.


Asunto(s)
Proteína del Grupo de Complementación G de la Anemia de Fanconi/genética , Polimorfismo Genético , Animales , Células CHO , Células Cultivadas , Cricetinae , Relación Dosis-Respuesta a Droga , Proteína del Grupo de Complementación D2 de la Anemia de Fanconi/metabolismo , Proteína del Grupo de Complementación D2 de la Anemia de Fanconi/efectos de la radiación , Proteína del Grupo de Complementación G de la Anemia de Fanconi/fisiología , Frecuencia de los Genes , Prueba de Complementación Genética , Humanos , Metilmetanosulfonato/farmacología , Mitomicina/toxicidad , Ubiquitina/metabolismo
13.
J AOAC Int ; 99(6): 1537-1554, 2016 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-27697104

RESUMEN

The Applied Biosystems™ RapidFinder™ STEC Detection Workflow (Thermo Fisher Scientific) is a complete protocol for the rapid qualitative detection of Escherichia coli (E. coli) O157:H7 and the "Big 6" non-O157 Shiga-like toxin-producing E. coli (STEC) serotypes (defined as serogroups: O26, O45, O103, O111, O121, and O145). The RapidFinder STEC Detection Workflow makes use of either the automated preparation of PCR-ready DNA using the Applied Biosystems PrepSEQ™ Nucleic Acid Extraction Kit in conjunction with the Applied Biosystems MagMAX™ Express 96-well magnetic particle processor or the Applied Biosystems PrepSEQ Rapid Spin kit for manual preparation of PCR-ready DNA. Two separate assays comprise the RapidFinder STEC Detection Workflow, the Applied Biosystems RapidFinder STEC Screening Assay and the Applied Biosystems RapidFinder STEC Confirmation Assay. The RapidFinder STEC Screening Assay includes primers and probes to detect the presence of stx1 (Shiga toxin 1), stx2 (Shiga toxin 2), eae (intimin), and E. coli O157 gene targets. The RapidFinder STEC Confirmation Assay includes primers and probes for the "Big 6" non-O157 STEC and E. coli O157:H7. The use of these two assays in tandem allows a user to detect accurately the presence of the "Big 6" STECs and E. coli O157:H7. The performance of the RapidFinder STEC Detection Workflow was evaluated in a method comparison study, in inclusivity and exclusivity studies, and in a robustness evaluation. The assays were compared to the U.S. Department of Agriculture (USDA), Food Safety and Inspection Service (FSIS) Microbiology Laboratory Guidebook (MLG) 5.09: Detection, Isolation and Identification of Escherichia coli O157:H7 from Meat Products and Carcass and Environmental Sponges for raw ground beef (73% lean) and USDA/FSIS-MLG 5B.05: Detection, Isolation and Identification of Escherichia coli non-O157:H7 from Meat Products and Carcass and Environmental Sponges for raw beef trim. No statistically significant differences were observed between the reference method and the individual or combined kits forming the candidate assay using either of the DNA preparation kits (manual or automated extraction). For the inclusivity and exclusivity evaluation, the RapidFinder STEC Detection Workflow, comprising both RapidFinder STEC screening and confirmation kits, correctly identified all 50 target organism isolates and correctly excluded all 30 nontarget strains for both of the assays evaluated. The results of these studies demonstrate the sensitivity and selectivity of the RapidFinder STEC Detection Workflow for the detection of E. coli O157:H7 and the "Big 6" STEC serotypes in both raw ground beef and beef trim. The robustness testing demonstrated that minor variations in the method parameters did not impact the accuracy of the assay and highlighted the importance of following the correct incubation temperatures.


Asunto(s)
Escherichia coli O157/genética , Escherichia coli O157/aislamiento & purificación , Escherichia coli Shiga-Toxigénica/genética , Escherichia coli Shiga-Toxigénica/aislamiento & purificación , Escherichia coli O157/metabolismo , Reacción en Cadena en Tiempo Real de la Polimerasa
14.
PLoS One ; 11(1): e0147434, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26824864

RESUMEN

Escherichia coli strains are classified based on O-antigens that are components of the lipopolysaccharide (LPS) in the cell envelope. O-antigens are important virulence factors, targets of both the innate and adaptive immune system, and play a role in host-pathogen interactions. Because they are highly immunogenic and display antigenic specificity unique for each strain, O-antigens are the biomarkers for designating O-types. Immunologically, 185 O-serogroups and 11 OX-groups exist for classification. Conventional serotyping for O-typing entails agglutination reactions between the O-antigen and antisera generated against each O-group. The procedure is labor intensive, not always accurate, and exhibits equivocal results. In this report, we present the sequences of 71 O-antigen gene clusters (O-AGC) and a comparison of all 196 O- and OX-groups. Many of the designated O-types, applied for classification over several decades, exhibited similar nucleotide sequences of the O-AGCs and cross-reacted serologically. Some O-AGCs carried insertion sequences and others had only a few nucleotide differences between them. Thus, based on these findings, it is proposed that several of the E. coli O-groups may be merged. Knowledge of the O-AGC sequences facilitates the development of molecular diagnostic platforms that are rapid, accurate, and reliable that can replace conventional serotyping. Additionally, with the scientific knowledge presented, new frontiers in the discovery of biomarkers, understanding the roles of O-antigens in the innate and adaptive immune system and pathogenesis, the development of glycoconjugate vaccines, and other investigations, can be explored.


Asunto(s)
Proteínas de Escherichia coli/genética , Escherichia coli/genética , Familia de Multigenes , Antígenos O/genética , Filogenia , Serotipificación/métodos , Pruebas de Aglutinación , Reacciones Cruzadas , Escherichia coli/clasificación , Glicosiltransferasas/genética , Humanos , Sueros Inmunes/química , Proteínas de Transporte de Membrana/genética , Nucleotidiltransferasas/genética , Antígenos O/clasificación , Análisis de Secuencia de ADN , Serogrupo , Terminología como Asunto
16.
DNA Repair (Amst) ; 2(12): 1405-17, 2003 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-14642568

RESUMEN

Xrcc1 knockout embryos show increased DNA breakage and apoptosis in tissues of the embryo proper prior to death at embryonic day E6.5. An additional deficiency in Trp53 allows Xrcc1(-/-) embryos to enlarge slightly and initiate gastrulation although ultimately death is delayed by less than 24h. Death presumably results from DNA damage that reaches toxic levels in the post-implantation mouse embryo. To investigate the level of XRCC1 protein needed for successful mouse development, we derived Xrcc1 transgene-complemented Xrcc1(-/-) mice that express Xrcc1 within the normal range or at a greatly reduced level (<10% normal). The greatly reduced XRCC1 protein level destabilized the XRCC1 partner protein DNA ligase III (LIG3) but still allowed for successful mouse development and healthy, fertile adults. Fibroblasts from these animals exhibited almost normal alkylation sensitivity measured by differential cytotoxicity. Thus, a large reduction of both XRCC1 and DNA ligase III has no observable effect on mouse embryogenesis and post-natal development, and no significant effect on cellular sensitivity to DNA alkylation. The presence of XRCC1, even at reduced levels of expression, is therefore capable of supporting mouse development and DNA repair.


Asunto(s)
ADN Ligasas/metabolismo , Reparación del ADN/genética , Proteínas de Unión al ADN/fisiología , Pérdida del Embrión , Desarrollo Embrionario y Fetal/genética , Ratones Noqueados/embriología , Alquilación , Animales , División Celular , ADN Ligasa (ATP) , Proteínas de Unión al ADN/genética , Fibroblastos/citología , Regulación del Desarrollo de la Expresión Génica , Marcación de Gen , Prueba de Complementación Genética , Ratones , Ratones Endogámicos C57BL , Ratones Endogámicos DBA , Proteínas de Unión a Poli-ADP-Ribosa , Transgenes , Proteína 1 de Reparación por Escisión del Grupo de Complementación Cruzada de las Lesiones por Rayos X , Proteínas de Xenopus
17.
J Food Prot ; 75(2): 347-52, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22289596

RESUMEN

Reducing the risk of Salmonella contamination in pet food is critical for both companion animals and humans, and its importance is reflected by the substantial increase in the demand for pathogen testing. Accurate and rapid detection of foodborne pathogens improves food safety, protects the public health, and benefits food producers by assuring product quality while facilitating product release in a timely manner. Traditional culture-based methods for Salmonella screening are laborious and can take 5 to 7 days to obtain definitive results. In this study, we developed two methods for the detection of low levels of Salmonella in pet food using real-time PCR: (i) detection of Salmonella in 25 g of dried pet food in less than 14 h with an automated magnetic bead-based nucleic acid extraction method and (ii) detection of Salmonella in 375 g of composite dry pet food matrix in less than 24 h with a manual centrifugation-based nucleic acid preparation method. Both methods included a preclarification step using a novel protocol that removes food matrix-associated debris and PCR inhibitors and improves the sensitivity of detection. Validation studies revealed no significant differences between the two real-time PCR methods and the standard U.S. Food and Drug Administration Bacteriological Analytical Manual (chapter 5) culture confirmation method.


Asunto(s)
Alimentación Animal/microbiología , Recuento de Colonia Microbiana/métodos , Análisis de los Alimentos/instrumentación , Contaminación de Alimentos/análisis , Reacción en Cadena en Tiempo Real de la Polimerasa , Salmonella/aislamiento & purificación , Animales , Seguridad de Productos para el Consumidor , ADN Bacteriano/análisis , Análisis de los Alimentos/métodos , Microbiología de Alimentos , Factores de Tiempo
18.
J Food Prot ; 74(6): 939-48, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21669071

RESUMEN

Three species--Vibrio cholerae, Vibrio parahaemolyticus, and Vibrio vulnificus--account for the majority of vibrio infections in humans. Rapid and accurate identification of Vibrio species has been problematic because phenotypic characteristics are variable within species. Additionally, biochemical identification and confirmation require 2 or more days to complete. Rapid and sensitive molecular techniques for the detection of vibrio pathogens would be useful for the surveillance and management of outbreaks. To facilitate the identification of human-pathogenic species, we designed and validated a highly sensitive, specific, and robust multiplex real-time PCR assay to identify V. cholerae, V. parahaemolyticus, and V. vulnificus using a four-dye configuration in a convenient lyophilized format. Multiple Vibrio strains were sequenced to verify candidate target TaqMan sites. Several individual assays within the multiplex contain multiple primers or probes to ensure detection of polymorphic variants. V. cholerae, V. parahaemolyticus, and V. vulnificus were detected either individually or in mixtures at ≤30 genomic copies. V. cholerae was specifically detected in the presence or absence of Vibrio mimicus. The Vibrio multiplex assay showed 100% specificity to all targets analyzed and no detection of nearest neighbor strains. Each assay exhibited 100% ± 10% efficiency. Multiplex real-time PCR can simplify pathogen detection and reduce costs per test since three species can be analyzed in a single reaction tube. Rapid and accurate detection of pathogenic vibrios in shellfish or seawater samples will improve the microbiological safety of seafood for consumers.


Asunto(s)
Contaminación de Alimentos/análisis , Reacción en Cadena de la Polimerasa/normas , Vibrio/aislamiento & purificación , Seguridad de Productos para el Consumidor , Humanos , Reacción en Cadena de la Polimerasa/métodos , Reproducibilidad de los Resultados , Alimentos Marinos/microbiología , Sensibilidad y Especificidad , Especificidad de la Especie , Vibrio cholerae/aislamiento & purificación , Vibrio parahaemolyticus/aislamiento & purificación , Vibrio vulnificus/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA