Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Kidney Blood Press Res ; 43(5): 1472-1478, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30235456

RESUMEN

BACKGROUND/AIMS: A recent alert from Spanish health authorities warned of a higher incidence of reported hypersensitivity reactions to hemodialysis membranes with polysulfone, in the 2017 review of acute reactions to dialyzers found only published reports in the 21st century on polysulfone and its derivatives. The aim is to assess/evaluate the current incidence and characteristics of hypersensitivity reactions in hemodialysis patients. METHODS: A retrospective multicentre study in 9 Spanish hospitals evaluated patients in whom a hypersensitivity reaction required a change in dialyzer membrane. RESULTS: A total of 37 patients out of 1561 (2.37%) had hypersensitivity reactions and clinical, epidemiological and analytical data were available for 33 patients (2.11%). The membranes involved were polysulfone (n=23), polynephron (n=8), polyethersulfone (n=1) and polyacrylonitrile (n=1). This distribution reflected the frequency of use of membranes in the participating dialysis units. The reactions were described as type A in 18 cases and type B in 15 cases. There were no significant differences between the two types in clinical symptoms, the composition of the membrane involved, the method of sterilization, the season, or the time during the session in which they occurred. The most frequent symptom was dyspnea/breathlessness (64% of reactions). Eosinophilia was common (74%). 54% of the reactions occurred within the first 30 minutes of hemodialysis, 64% occurred during the first year of dialysis, and 54% required discontinuation of dialysis session. Cellulose triacetate was used as an alternative dialyzer in 78% of the cases. CONCLUSION: The incidence of hypersensitivity reactions was in the range found in reports from 20 years ago and is observed associated with synthetic membranes, not just polysulfones. Cellulose triacetate appears to be a good alternative for these patients.


Asunto(s)
Hipersensibilidad/etiología , Diálisis Renal/efectos adversos , Resinas Acrílicas , Anciano , Anciano de 80 o más Años , Celulosa/análogos & derivados , Celulosa/inmunología , Celulosa/uso terapéutico , Femenino , Humanos , Masculino , Membranas Artificiales , Persona de Mediana Edad , Polímeros , Diálisis Renal/instrumentación , Estudios Retrospectivos , Sulfonas/inmunología
2.
Nefrologia (Engl Ed) ; 41(4): 461-466, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-36165115

RESUMEN

INTRODUCTION: Previous reports have shown very high mortality among hemodialyisis patients. Our goal was to analyze the mortality of patients in the Renal Registry of Patients who remained exclusively on hemodialysis treatment. METHODS: The cohort of patients who started treatment in the community of Castilla-La Mancha between 2010 and 2012 and remained on hemodialysis treatment was analysed until the end of 2017. Age, sex, primary kidney disease, vascular access, hemoglobin, Charlson index and serum albumin were included. RESULTS: Mortality rate was 63,4% after 5 years and 76% at the end of the study, with no difference between males and females, and was linked to an older age, urgent onset or in those with acute deterioration of chronic kidney disease, the use of catheters or albumin less than 3.5 g/dl. CONCLUSIONS: Mortality in patients who remain on hemodialysis is very high and is associated with non-modifiable factors such as age but also others that we can prevent or treat such as type of vascular access or nutrition status at the beginning of treatment.


Asunto(s)
Fallo Renal Crónico , Femenino , Hemoglobinas/análisis , Humanos , Fallo Renal Crónico/terapia , Masculino , Sistema de Registros , Diálisis Renal , Albúmina Sérica/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA