Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Innov Card Rhythm Manag ; 15(3): 5805-5809, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38584752

RESUMEN

A young man presented following successful cardiac resuscitation after an out-of-hospital cardiac arrest. During his admission, he had multiple runs of short-coupled ventricular fibrillation with a similar morphology premature ventricular complex (PVC) trigger. He was brought to the electrophysiology laboratory, and, with a high dose of isoprenaline, the PVC was localised to the moderator band. Ablation induced short runs of ventricular tachycardia before elimination of the PVC. He subsequently underwent subcutaneous implantable cardiac defibrillator implantation before his discharge.

2.
Circ Arrhythm Electrophysiol ; 17(3): e012255, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38318720

RESUMEN

BACKGROUND: Pulsed field ablation uses electrical fields to cause nonthermal cell death over several hours. Polarization-sensitive optical coherence reflectometry is an optical imaging technique that can detect changes in the tissue ultrastructure in real time, which occurs when muscular tissue is damaged. The objective of this study was to evaluate the ability of a polarization-sensitive optical coherence reflectometry system to predict the development of chronic lesions based on acute changes in tissue birefringence during pulsed field ablation. METHODS: Superior vena cava isolation was performed in 30 swine using a biphasic, bipolar pulsed field ablation system delivered with a nonirrigated focal tip catheter. Acute changes in tissue birefringence and voltage abatement were analyzed for each individual lesion. A high-resolution electroanatomical map was performed at baseline and 4 to 12 weeks after ablation to locate electrical gaps in the ablated area. RESULTS: A total of 141 lesions were delivered and included in the analysis. Acute electrical isolation based on the electroanatomical map was achieved in 96% of the animals, but chronic isolation was only seen in 14 animals (46%). The mean voltage abatement of lesions that showed recovery was 82.8%±14.6% versus 84.4%±17.4% for those that showed fibrosis (P=0.7). The mean acute reduction in tissue birefringence in points demonstrating fibrosis was 63.8%±11.3% versus 9.1%±0.1% in the points that resulted in electrical gaps. A threshold of acute reduction of birefringence of ≥20% could predict chronic lesion formation with a sensitivity of 96% and a specificity of 83%. CONCLUSIONS: Acute tissue birefringence changes assessed with polarization-sensitive optical coherence reflectometry during pulsed field ablation can predict chronic lesion formation and guide the ablation procedure although limited by the tissue thickness.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Porcinos , Animales , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Vena Cava Superior/cirugía , Tórax , Venas Pulmonares/cirugía , Fibrosis , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA