Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-32375358

RESUMEN

(1) Background: Diagnostic testing for cystic fibrosis (CF) is based on a sweat chloride test (SCT) considering the appropriate signs and symptoms of the disease and results of a gene mutation analysis. In 2014, the Istituto Superiore di Sanità (ISS) established a pilot Italian external quality assessment program for CF SCT (Italian EQA-SCT), which is now a third party service carried out by the ISS. (2) Methods: The ongoing scheme is prospective, enrollment is voluntary, and the payment of a fee is required. Results are shared through a dedicated web-facility. Assessment covers the analysis, interpretation, and reporting of results. (3) Results: Thirteen, fifteen, sixteen, and fifteen different laboratories, respectively, participated from 2015 to 2016 and from 2018 to 2019 in the Italian EQA-SCT scheme. Eleven different laboratories participated each year in all four rounds of the Italian EQA-SCT. (4) Conclusions: The overall results obtained from the laboratories participating constantly clearly show that their qualitative and quantitative performance improved significantly. This is due to the opportunity-after receiving the EQA results-to constantly review their performance and address any inconsistencies. We firmly believe that participation in the EQA program will improve the quality of participating laboratories and that EQA participation should become mandatory as a fundamental requirement for laboratory accreditation.


Asunto(s)
Fibrosis Quística , Sudor , Cloruros/análisis , Fibrosis Quística/diagnóstico , Humanos , Italia , Estudios Prospectivos , Garantía de la Calidad de Atención de Salud , Sudor/química
2.
Genet Test ; 12(2): 279-88, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18452397

RESUMEN

The Italian External Quality Assessment scheme for fragile X syndrome started in 2001 as an activity funded by the National Health System and coordinated by the National Institute of Public Health. The aim of this work is to present the data of 5 years (2001--2004 and 2006) of survey. The External Quality Assessment scheme was designed to cover the following points: (a) genotyping and (b) interpretation and reporting of results. Overall, the scheme covered about 65% of all Italian public laboratories. The average reporting of results was 91.6%, with an overall success rate of 76%. The rate of diagnostic errors observed was on average 5%. Inaccuracy in sizing of CGG repeats of normal and premutated alleles was reported. During the survey the proportion of laboratories using a Southern blotting, polymerase chain reaction, and ABI sizing kit in combination rose from 36.8% to 70.6%. The reports from laboratories showed incompleteness and considerable variations in expected outcomes. For this reason, in 2004 a model for written reports was introduced. In conclusion, these data underscore the need to participate in External Quality Assessment schemes as an educational resource to ensure quality in molecular genetic testing.


Asunto(s)
Síndrome del Cromosoma X Frágil/genética , Pruebas Genéticas , Laboratorios/normas , Técnicas de Diagnóstico Molecular , Garantía de la Calidad de Atención de Salud , Recolección de Datos , Errores Diagnósticos , Síndrome del Cromosoma X Frágil/diagnóstico , Pruebas Genéticas/métodos , Pruebas Genéticas/normas , Genotipo , Guías como Asunto , Humanos , Italia , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Control de Calidad
3.
Ann Ist Super Sanita ; 54(2): 109-116, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29916415

RESUMEN

BACKGROUND: Italian External Quality Assessment (IEQA) Program in Cytogenetics, established in 2001 by the Istituto Superiore di Sanità (ISS), covers both Constitutional and Oncohaematological diagnosis. In 2013, performance criteria were defined and adopted. In this paper, we present the data from the first 4 years of activity (2013-2016) following the introduction of performance criteria. METHODS: The enrollment is voluntary, fee-based and open to both public and private Italian laboratories. The scheme is annual and retrospective; a national panel of experts assess technical, analytical and interpretative performance. RESULTS: Overall, 95 distinct Italian laboratories participated in different Cytogenetics IEQA schemes over the 2013-2016 years and most of the laboratories took part in Constitutional diagnosis. General hospitals and local health centers represented 40% of the total participants and the percentage of laboratories from Northern Regions was more than 45% of total participants throughout the 4-year period. As regards the performance evaluation, on average, 11, 9 and 23% of participants were marked as poor performers in Prenatal, Postnatal and Oncohaematological schemes, respectively. With regard to critical errors, ISCN nomenclature in Prenatal and Postnatal schemes, and interpretation in Oncohaematological diagnosis, were identified as main issues. On the other hand, karyotype errors and inadequate analysis decreased strongly, over the 4 years, in Constitutional and Oncohaematological diagnosis, respectively. CONCLUSIONS: Our data show that the introduction of poor performance encourages laboratories to address critical issues, and the IEQA participation helps to improve quality in cytogenetic testing.


Asunto(s)
Citogenética/normas , Pruebas Genéticas/normas , Garantía de la Calidad de Atención de Salud , Adulto , Niño , Neoplasias Hematológicas/diagnóstico , Humanos , Italia , Laboratorios , Mejoramiento de la Calidad
4.
Ann Ist Super Sanita ; 53(4): 305-313, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29297860

RESUMEN

BACKGROUND: Diagnostic testing in cystic fibrosis (CF) is based on the sweat chloride test (SCT) in the context of appropriate signs and symptoms of disease and results of the gene mutation analysis. In 2014 the Istituto Superiore di Sanità (ISS) established a pilot Italian external quality assessment program for CF sweat chloride test (Italian EQA-SCT). In 2015 this activity was recognized as a third party service carried out by the ISS. The aim of the paper is to compare 2015 and 2016 results and experiences. METHODS: The scheme is prospective; enrollment is voluntary and the payment of a fee is required. Participants are registered and identified by a specific Identification Number (ID) through a dedicated web-facility. Assessment covers analysis, interpretation and reporting of results. RESULTS: Thirteen and fifteen laboratories, participated in the 2015 and 2016 round respectively. Seven laboratories participated constantly from 2014, eleven participated both in 2015 and 2016 and four participated in 2016 for the first time. Variability in scores of chloride titration and heterogeneity in interpretation/reporting results were detected in both rounds. A total of 18 critical errors in chloride titration were made by eight different participants. Four laboratories made errors in chloride titration in 2015 but drastically improved their performance in 2016. In 2016 poor performance criteria were established and adopted. CONCLUSIONS: Even though results show variability in performance of laboratories, constant and mandatory participation may contribute to the improvement of performance and quality reached by laboratory.


Asunto(s)
Cloruros/análisis , Fibrosis Quística/diagnóstico , Sudor/química , Humanos , Italia , Estudios Prospectivos , Garantía de la Calidad de Atención de Salud , Reproducibilidad de los Resultados
5.
Clin Biochem ; 49(7-8): 601-5, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26851350

RESUMEN

OBJECTIVES: Sweat chloride test is the gold standard test for cystic fibrosis (CF) diagnosis. In 2014 the Istituto Superiore di Sanità established the Italian pilot external quality assessment program for CF sweat test (IEQA-ST). DESIGN AND METHODS: Ten laboratories, included among the 33 Italian CF Referral Centers, were selected and enrolled on the basis of their attitude to perform sweat test (ST) analysis by using methods recommended by the Italian Guidelines. They received three different sweat-like samples (normal, borderline and pathologic chloride concentration), with mock clinical indications, for analysis according to routine procedures. Assessment, performed by a panel of experts, covered analytical performance, interpretation and reporting of results; categories of "poor" and "satisfactory" performance were not defined. All data were managed through a web utility. RESULTS: The program identified important areas of interest and, in some case, of concern. It is important to underline that results are referred to a small proportion, i.e. about 30%, of Italian laboratories performing CF ST in the context of the Referral Centers. CONCLUSIONS: Data collected highlight the importance of participation in EQA programs as it may improve laboratory/clinical performance; our study represents a model for the setting up of a large-scale EQA scheme for ST.


Asunto(s)
Cloruros/análisis , Técnicas de Laboratorio Clínico/normas , Fibrosis Quística/diagnóstico , Pruebas Diagnósticas de Rutina/normas , Laboratorios/normas , Control de Calidad , Sudor/química , Estudios de Seguimiento , Humanos , Italia , Proyectos Piloto , Estudios Prospectivos , Proyectos de Investigación
6.
Genet Test Mol Biomarkers ; 14(2): 175-81, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20136519

RESUMEN

Familial adenomatous polyposis is a rare autosomal dominant inherited disease (incidence, 1/8000). More than 90% of families affected by familial adenomatous polyposis have a mutation in the tumor suppressor gene adenomatous polyposis coli (APC). Mutations in this gene are characterized by 100% penetrance, although there is a variation in phenotypic expression of the disease. According to a 2004 survey of the Italian Human Genetic Society, about 264 APC gene molecular genetic tests were performed by Italian laboratories per year. The Italian External Quality Assessment (IEQA), financially supported by the Ministry of Health and coordinated by the Istituto Superiore di Sanità, was started in 2000 to improve the quality of molecular genetic tests in Italy. In the frame of the IEQA, about 50% of public laboratories performing APC gene tests have been monitored. The number of responding public laboratories during the 5 years was 6, 7, 7, 7, and 5 from 2001 to 2006, respectively; on average, 96.3% of samples completely analyzed were correctly genotyped. Methods used by laboratories to detect mutation were direct sequencing, single-strand conformation polymorphism, protein truncation test, and denaturing high-performance liquid chromatography. Written reports were not homogeneous among laboratories, although a new form of written report was proposed to laboratories in 2004. It will be interesting to monitor the effects of the reporting model and the output of this educational action in the future.


Asunto(s)
Poliposis Adenomatosa del Colon/genética , Genes APC , Pruebas Genéticas/normas , Mutación , Poliposis Adenomatosa del Colon/diagnóstico , Codón sin Sentido , Análisis Mutacional de ADN/métodos , Análisis Mutacional de ADN/normas , Recolección de Datos , Mutación del Sistema de Lectura , Pruebas Genéticas/métodos , Agencias Gubernamentales , Humanos , Italia , Laboratorios/normas , Control de Calidad
7.
Reprod Toxicol ; 29(4): 427-32, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20307648

RESUMEN

The plasticizer di-(2-ethylhexyl)phthalate (DEHP) affects reproductive development, glycogen and lipid metabolism. Whereas liver is a main DEHP target in adult rodents, the potential impact on metabolic programming is unknown. Effects of in utero DEHP exposure on liver development were investigated upon treatment of pregnant CD-1 mice on gestational days (GD)11-19. F1 mice were examined at post-natal days 21 (weaning) and 35 (start of puberty): parameters included liver histopathological, immunocytochemical and alpha-fetoprotein (AFP) gene expression analyses. In utero DEHP exposure altered post-natal liver development in weanling mice causing significant, dose-related (i) increased hepatosteatosis, (ii) decreased glycogen storage, (iii) increased beta-catenin intracytoplasmic localization (females only). At puberty, significantly decreased glycogen storage was still present in males. A treatment-induced phenotype was identified with lack of glycogen accumulation and intracytoplasmic localization of beta-catenin which was associated with increased AFP gene expression. Our findings suggested that DEHP alters post-natal liver development delaying the programming of glycogen metabolism.


Asunto(s)
Enfermedad Hepática Inducida por Sustancias y Drogas/etiología , Dietilhexil Ftalato/toxicidad , Contaminantes Ambientales/toxicidad , Hígado Graso/inducido químicamente , Hígado/efectos de los fármacos , Efectos Tardíos de la Exposición Prenatal/inducido químicamente , Animales , Enfermedad Hepática Inducida por Sustancias y Drogas/metabolismo , Enfermedad Hepática Inducida por Sustancias y Drogas/patología , Citoplasma/metabolismo , Hígado Graso/metabolismo , Hígado Graso/patología , Femenino , Expresión Génica/efectos de los fármacos , Hígado/crecimiento & desarrollo , Hígado/metabolismo , Glucógeno Hepático/metabolismo , Exposición Materna , Ratones , Ratones Endogámicos , Embarazo , Efectos Tardíos de la Exposición Prenatal/metabolismo , ARN Mensajero/metabolismo , alfa-Fetoproteínas/genética , alfa-Fetoproteínas/metabolismo , beta Catenina/metabolismo
8.
Genet Test Mol Biomarkers ; 13(1): 31-6, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19309271

RESUMEN

The Italian scheme of External Quality Assessment for beta-thalassemia started in 2001 as part of a project twice funded by the Italian Ministry of Health and coordinated by the Istituto Superiore di Sanità. To date, five trials have been performed (2001-2004 and 2006). The aim of the Italian scheme is to help public laboratories in improving and reaching a high standard of quality when performing a molecular test. Many laboratories took part in the 5-year project, and their participation was constant during the whole period. The aims of this paper are to describe the genotyping and reporting results as well as focusing on the techniques and the testing strategies adopted to detect mutations. Almost 99% of the alleles analyzed were correctly detected by laboratories, while 0.33% of the analyses gave a wrong result. Reverse dot blot was the most used technique, and it was always used in the strategies adopted by laboratories to detect mutations. The reports sent by laboratories showed incompleteness and heterogeneity; thus, a new model for written reports has been introduced since 2004. It will be interesting to monitor the effects of the reporting model and the output of this educational action in the future.


Asunto(s)
Análisis Mutacional de ADN/normas , Pruebas Genéticas/normas , Talasemia beta/genética , Alelos , Análisis Mutacional de ADN/métodos , Análisis Mutacional de ADN/estadística & datos numéricos , Recolección de Datos , Errores Diagnósticos , Femenino , Pruebas Genéticas/métodos , Pruebas Genéticas/estadística & datos numéricos , Genotipo , Humanos , Italia , Laboratorios/normas , Masculino , Mutación , Embarazo , Diagnóstico Prenatal , Garantía de la Calidad de Atención de Salud , Globinas beta/genética , Talasemia beta/diagnóstico , Talasemia beta/prevención & control
9.
Transl Oncol ; 2(3): 157-63, 2009 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-19701500

RESUMEN

Liver cancers in children are rare representing only 1.1% of malignancies, with an annual incidence rate of 1.5 cases per million. Hepatoblastoma and hepatocellular carcinomas are the most common malignancies of the liver occurring in young people aged 15 years or younger. Molecular basis of both tumors are still unclear, and common markers (i.e., CTNNB1, APC, IGF-2) are not always useful in the characterization of sporadic forms; in this respect, microRNA recently associated with carcinogenesis could play a pivotal role in their onset. CTNNB1 and APC were analyzed by sequencing, and IGF-2 promoter methylation status was assessed by methylation-specific polymerase chain reaction. MicroRNA expression was assayed by microarray and quantitative reverse transcription-polymerase chain reaction in hepatoblastoma samples. Although few genomic alterations were detected in ours samples, an altered expression of somemicroRNA in hepatoblastoma was observed. Unsupervised clustering shows that microRNA profile can distinguish tumor from nontumor tissues. Further analyses of microRNA contents in hepatoblastoma compared with hepatocellular carcinoma highlighted four upregulated microRNA (miR-214, miR-199a, miR-150 [P < .01], and miR-125a [P < .05]) and one downregulated microRNA (miR-148a [P < .01]). In conclusion, although our samples were poorly informative from a genetic point of view, they showed a peculiar microRNA expression pattern compared with nontumor tissues and hepatocellular carcinoma. MicroRNA could represent valid markers for the classification of pediatric liver tumors.

11.
Clin Chem Lab Med ; 45(2): 254-60, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17311518

RESUMEN

BACKGROUND: The Italian External Quality Control Programme for cystic fibrosis molecular diagnosis started in 2001; public laboratories distributed throughout Italy participated on a voluntary basis. METHODS: The Italian Public Health Institute (Istituto Superiore di Sanità) sent six validated DNA samples to participating laboratories: technical and clinical information was provided for each sample. Laboratories were required to analyse all six samples. For each sample the laboratories had to provide the results (including raw data) and a report of molecular analysis within 2 months using current methods and nomenclature. Raw data and reports were evaluated by a Steering Committee and their comments were sent to each laboratory. RESULTS: Genotyping results indicated a general good level of quality for all laboratories, i.e., approximately 1% of alleles were incorrectly assigned each year due to analytical (45%) and misinterpretation (45%) errors. During the first 2 years, more than 70% of laboratories did not test for some regional Italian mutations. Commercial kits for reverse dot-blot and oligonucleotide ligation assay PCR were used to detect mutations by 52.8% and 29.5%, respectively, of the participating laboratories. Reporting of results was still inadequate; in 2004 a model for the written report was introduced, but not all laboratories used it. CONCLUSIONS: Our data show that few genotyping errors were made by laboratories and were principally due to misinterpretation and analytical reasons. However, reports are still inadequate and it will be interesting to evaluate the introduction of the reporting model in future years.


Asunto(s)
Fibrosis Quística/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Control de Calidad , Técnicas de Laboratorio Clínico , Fibrosis Quística/genética , Regulador de Conductancia de Transmembrana de Fibrosis Quística/genética , Errores Diagnósticos , Pruebas Genéticas/métodos , Pruebas Genéticas/normas , Genotipo , Humanos , Italia , Mutación , Juego de Reactivos para Diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA