1.
Lancet ; 389(10071): 805-814, 2017 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-28104287

RESUMEN

BACKGROUND: Patients admitted to hospital can acquire multidrug-resistant organisms and Clostridium difficile from inadequately disinfected environmental surfaces. We determined the effect of three enhanced strategies for terminal room disinfection (disinfection of a room between occupying patients) on acquisition and infection due to meticillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, C difficile, and multidrug-resistant Acinetobacter. METHODS: We did a pragmatic, cluster-randomised, crossover trial at nine hospitals in the southeastern USA. Rooms from which a patient with infection or colonisation with a target organism was discharged were terminally disinfected with one of four strategies: reference (quaternary ammonium disinfectant except for C difficile, for which bleach was used); UV (quaternary ammonium disinfectant and disinfecting ultraviolet [UV-C] light except for C difficile, for which bleach and UV-C were used); bleach; and bleach and UV-C. The next patient admitted to the targeted room was considered exposed. Every strategy was used at each hospital in four consecutive 7-month periods. We randomly assigned the sequence of strategies for each hospital (1:1:1:1). The primary outcomes were the incidence of infection or colonisation with all target organisms among exposed patients and the incidence of C difficile infection among exposed patients in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, NCT01579370. FINDINGS: 31 226 patients were exposed; 21 395 (69%) met all inclusion criteria, including 4916 in the reference group, 5178 in the UV group, 5438 in the bleach group, and 5863 in the bleach and UV group. 115 patients had the primary outcome during 22 426 exposure days in the reference group (51·3 per 10 000 exposure days). The incidence of target organisms among exposed patients was significantly lower after adding UV to standard cleaning strategies (n=76; 33·9 cases per 10 000 exposure days; relative risk [RR] 0·70, 95% CI 0·50-0·98; p=0·036). The primary outcome was not statistically lower with bleach (n=101; 41·6 cases per 10 000 exposure days; RR 0·85, 95% CI 0·69-1·04; p=0·116), or bleach and UV (n=131; 45·6 cases per 10 000 exposure days; RR 0·91, 95% CI 0·76-1·09; p=0·303) among exposed patients. Similarly, the incidence of C difficile infection among exposed patients was not changed after adding UV to cleaning with bleach (n=38 vs 36; 30·4 cases vs 31·6 cases per 10 000 exposure days; RR 1·0, 95% CI 0·57-1·75; p=0·997). INTERPRETATION: A contaminated health-care environment is an important source for acquisition of pathogens; enhanced terminal room disinfection decreases this risk. FUNDING: US Centers for Disease Control and Prevention.


Asunto(s)
Clostridioides difficile , Infecciones por Clostridium/prevención & control , Infección Hospitalaria/microbiología , Infección Hospitalaria/prevención & control , Desinfección/métodos , Farmacorresistencia Bacteriana Múltiple , Habitaciones de Pacientes/normas , Infecciones por Clostridium/epidemiología , Estudios Cruzados , Desinfectantes/administración & dosificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Compuestos de Amonio Cuaternario/administración & dosificación , Hipoclorito de Sodio/administración & dosificación , Rayos Ultravioleta , Estados Unidos/epidemiología
2.
Open Forum Infect Dis ; 7(6): ofaa164, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32528999

RESUMEN

BACKGROUND: The largest health care-associated infection outbreak in the United States occurred during 2012-2013. Following injection of contaminated methylprednisolone, 753 patients developed infection with a dematiaceous mold, Exserohilum rostratum. The long-term outcomes of these infections have not been described. METHODS: This retrospective cohort study of 440 of a total of 753 patients with proven or probable Exserohilum infection evaluated clinical and radiographic findings, antifungal therapy and associated adverse effects, and outcomes at 6 weeks, 3, 6, 9, and 12 months after diagnosis. Patients were grouped into 4 disease categories: meningitis with/without stroke, spinal or paraspinal infections, meningitis/stroke plus spinal/paraspinal infections, and osteoarticular infections. RESULTS: Among the 440 patients, 223 (51%) had spinal/paraspinal infection, 82 (19%) meningitis/stroke, 123 (28%) both, and 12 (3%) osteoarticular infection. Of 82 patients with meningitis/stroke, 18 (22%) died; among those surviving, 87% were cured at 12 months. Only 7 (3%) of 223 patients with spinal/paraspinal infection died, but at 12 months, 68% had persistent or worsening pain and only 47% were cured. For the 123 patients with both meningitis/stroke and spinal/paraspinal infection, 10 (8%) died, pain persisted in 72%, and 52% were cured at 12 months. Only 37% of those with osteoarticular infection were cured at 12 months. Adverse events from antifungal therapy were noted at 6 weeks in 71% of patients on voriconazole and 81% on amphotericin B. CONCLUSIONS: Fungal infections related to contaminated methylprednisolone injections culminated in death in 8% of patients. Persistent pain and disability were seen at 12 months in most patients with spinal/paraspinal infections.

3.
Infect Control Hosp Epidemiol ; 39(2): 157-163, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29331170

RESUMEN

OBJECTIVE To summarize and discuss logistic and administrative challenges we encountered during the Benefits of Enhanced Terminal Room (BETR) Disinfection Study and lessons learned that are pertinent to future utilization of ultraviolet (UV) disinfection devices in other hospitals DESIGN Multicenter cluster randomized trial SETTING AND PARTICIPANTS Nine hospitals in the southeastern United States METHODS All participating hospitals developed systems to implement 4 different strategies for terminal room disinfection. We measured compliance with disinfection strategy, barriers to implementation, and perceptions from nurse managers and environmental services (EVS) supervisors throughout the 28-month trial. RESULTS Implementation of enhanced terminal disinfection with UV disinfection devices provides unique challenges, including time pressures from bed control personnel, efficient room identification, negative perceptions from nurse managers, and discharge volume. In the course of the BETR Disinfection Study, we utilized several strategies to overcome these barriers: (1) establishing safety as the priority; (2) improving communication between EVS, bed control, and hospital administration; (3) ensuring availability of necessary resources; and (4) tracking and providing feedback on compliance. Using these strategies, we deployed ultraviolet (UV) disinfection devices in 16,220 (88%) of 18,411 eligible rooms during our trial (median per hospital, 89%; IQR, 86%-92%). CONCLUSIONS Implementation of enhanced terminal room disinfection strategies using UV devices requires recognition and mitigation of 2 key barriers: (1) timely and accurate identification of rooms that would benefit from enhanced terminal disinfection and (2) overcoming time constraints to allow EVS cleaning staff sufficient time to properly employ enhanced terminal disinfection methods. TRIAL REGISTRATION Clinical trials identifier: NCT01579370 Infect Control Hosp Epidemiol 2018;39:157-163.


Asunto(s)
Actitud del Personal de Salud , Infección Hospitalaria/prevención & control , Desinfección/métodos , Rayos Ultravioleta , Adhesión a Directriz , Hospitales , Humanos , Control de Infecciones , Relaciones Interprofesionales , Enfermeras Administradoras/psicología , Habitaciones de Pacientes , Sudeste de Estados Unidos , Encuestas y Cuestionarios
4.
Lancet Infect Dis ; 18(8): 845-853, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29880301

RESUMEN

BACKGROUND: The hospital environment is a source of pathogen transmission. The effect of enhanced disinfection strategies on the hospital-wide incidence of infection has not been investigated in a multicentre, randomised controlled trial. We aimed to assess the effectiveness of four disinfection strategies on hospital-wide incidence of multidrug-resistant organisms and Clostridium difficile in the Benefits of Enhanced Terminal Room (BETR) Disinfection study. METHODS: We did a prespecified secondary analysis of the results from the BETR Disinfection study, a pragmatic, multicentre, crossover cluster-randomised trial that assessed four different strategies for terminal room disinfection in nine hospitals in the southeastern USA. Rooms from which a patient with a specific infection or colonisation (due to the target organisms C difficile, meticillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci (VRE), or multidrug-resistant Acinetobacter spp) was discharged were terminally disinfected with one of four strategies: standard disinfection (quaternary ammonium disinfectant, except for C difficile, for which 10% hypochlorite [bleach] was used; reference); standard disinfection and disinfecting ultraviolet light (UV-C), except for C difficile, for which bleach and UV-C was used (UV strategy); 10% hypochlorite (bleach strategy); and bleach and UV-C (bleach and UV strategy). We randomly assigned the sequence of strategies for each hospital (1:1:1:1), and each strategy was used for 7 months, including a 1-month wash-in period and 6 months of data collection. The prespecified secondary outcomes were hospital-wide, hospital-acquired incidence of all target organisms (calculated as number of patients with hospital-acquired infection with a target organism per 10 000 patient days), and hospital-wide, hospital-acquired incidence of each target organism separately. BETR Disinfection is registered with ClinicalTrials.gov, number NCT01579370. FINDINGS: Between April, 2012, and July, 2014, there were 271 740 unique patients with 375 918 admissions. 314 610 admissions met all inclusion criteria (n=73 071 in the reference study period, n=81 621 in the UV study period, n=78 760 in the bleach study period, and n=81 158 in the bleach and UV study period). 2681 incidenct cases of hospital-acquired infection or colonisation occurred during the study. There was no significant difference in the hospital-wide risk of target organism acquisition between standard disinfection and the three enhanced terminal disinfection strategies for all target multidrug-resistant organisms (UV study period relative risk [RR] 0·89, 95% CI 0·79-1·00; p=0·052; bleach study period 0·92, 0·79-1·08; p=0·32; bleach and UV study period 0·99, 0·89-1·11; p=0·89). The decrease in risk in the UV study period was driven by decreases in risk of acquisition of C difficile (RR 0·89, 95% CI 0·80-0·99; p=0·031) and VRE (0·56, 0·31-0·996; p=0·048). INTERPRETATION: Enhanced terminal room disinfection with UV in a targeted subset of high-risk rooms led to a decrease in hospital-wide incidence of C difficile and VRE. Enhanced disinfection overcomes limitations of standard disinfection strategies and is a potential strategy to reduce the risk of acquisition of multidrug-resistant organisms and C difficile. FUNDING: US Centers for Disease Control and Prevention.


Asunto(s)
Clostridioides difficile , Infecciones por Clostridium/prevención & control , Infección Hospitalaria/microbiología , Infección Hospitalaria/prevención & control , Desinfección/métodos , Farmacorresistencia Bacteriana Múltiple , Hospitales/normas , Ensayos Clínicos Controlados Aleatorios como Asunto , Infecciones por Clostridium/epidemiología , Estudios Cruzados , Desinfectantes/administración & dosificación , Humanos , Compuestos de Amonio Cuaternario/administración & dosificación , Hipoclorito de Sodio/administración & dosificación , Sudeste de Estados Unidos , Rayos Ultravioleta