Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Sci Rep ; 10(1): 6996, 2020 04 24.
Artículo en Inglés | MEDLINE | ID: mdl-32332790

RESUMEN

There is a need for noninvasive repeatable biomarkers to detect early cancer treatment response and spare non-responders unnecessary morbidities and costs. Here, we introduce three-dimensional (3D) dynamic contrast enhanced ultrasound (DCE-US) perfusion map characterization as inexpensive, bedside and longitudinal indicator of tumor perfusion for prediction of vascular changes and therapy response. More specifically, we developed computational tools to generate perfusion maps in 3D of tumor blood flow, and identified repeatable quantitative features to use in machine-learning models to capture subtle multi-parametric perfusion properties, including heterogeneity. Models were developed and trained in mice data and tested in a separate mouse cohort, as well as early validation clinical data consisting of patients receiving therapy for liver metastases. Models had excellent (ROC-AUC > 0.9) prediction of response in pre-clinical data, as well as proof-of-concept clinical data. Significant correlations with histological assessments of tumor vasculature were noted (Spearman R > 0.70) in pre-clinical data. Our approach can identify responders based on early perfusion changes, using perfusion properties correlated to gold-standard vascular properties.


Asunto(s)
Medios de Contraste/química , Imagenología Tridimensional/métodos , Animales , Área Bajo la Curva , Biomarcadores/metabolismo , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/metabolismo , Aprendizaje Automático , Masculino , Ratones , Neoplasias/diagnóstico por imagen , Neoplasias/metabolismo , Análisis de Componente Principal
2.
Neuroimaging Clin N Am ; 13(3): 525-40, 2003 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-14631689

RESUMEN

Fibro-osseous, osseous, cartilaginous, and giant cell lesions of the mandible, maxilla, and other craniofacial bones share overlapping clinical, radiologic, and pathologic features that may lead to diagnostic confusion and possible misdiagnosis. The value of combined clinical-radiologic-pathologic correlation in the diagnosis of these lesions is paramount to achieving the correct diagnosis with subsequent implementation of appropriate therapeutic intervention.


Asunto(s)
Huesos Faciales/diagnóstico por imagen , Fibroma Osificante/diagnóstico por imagen , Tumor Óseo de Células Gigantes/diagnóstico por imagen , Neoplasias Mandibulares/diagnóstico por imagen , Neoplasias Maxilares/diagnóstico por imagen , Neoplasias Craneales/diagnóstico por imagen , Diagnóstico Diferencial , Huesos Faciales/patología , Fibroma Osificante/patología , Tumor Óseo de Células Gigantes/patología , Humanos , Neoplasias Mandibulares/patología , Neoplasias Maxilares/patología , Radiografía , Neoplasias Craneales/patología
3.
J Endovasc Ther ; 10(3): 643-6, 2003 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12932180

RESUMEN

PURPOSE: To report the use of a coronary stent-graft for the endovascular treatment of a spontaneous internal carotid artery (ICA) dissection complicated by a large pseudoaneurysm. CASE REPORT: A 68-year-old man presented to an outside hospital with complaints of headache, severe left-sided neck pain, fever, chills, and vomiting. Contrast-enhanced computed tomography revealed a large (3.5x3 cm) extracranial aneurysm of the left ICA. The patient was emergently transferred to our facility for endovascular treatment of the carotid aneurysm. Via a percutaneous access in the right common femoral artery, 2 Jostent coronary stent-grafts were deployed across the aneurysm with no evidence of a residual pseudoaneurysm. The patient was hemodynamically stable throughout the procedure. Duplex examination at 9 months revealed no evidence of a residual pseudoaneurysm, dissection, or endoleak. CONCLUSIONS: Covered coronary stents may have a role in the treatment of spontaneous ICA dissection with pseudoaneurysm formation.


Asunto(s)
Angioplastia , Disección de la Arteria Carótida Interna/cirugía , Fístula del Seno Cavernoso de la Carótida/cirugía , Anciano , Disección de la Arteria Carótida Interna/complicaciones , Fístula del Seno Cavernoso de la Carótida/complicaciones , Humanos , Masculino
4.
Catheter Cardiovasc Interv ; 57(2): 142-7, 2002 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-12357508

RESUMEN

Third-generation intracoronary stents allow deployment at higher pressures, possibly obviating the need for high-pressure postdilations and also possibly reducing restenosis. This study evaluated the ability of the Tristar Coronary Stent System to produce optimal stent deployment as measured by intravascular ultrasound (IVUS) and quantitative coronary angiography in 46 patients. Optimal stent deployment was defined as minimal luminal area > 80% of the average of the proximal and distal reference luminal areas. After initial deployment, 74.5% of stents met criteria for optimal stent deployment by IVUS, with an average stent expansion ratio of 89.6%. Ten stents (18.2%) were postdilated. Four patients (8.7%) had a major adverse cardiac event, one patient died, one patient had a myocardial infarction, and two patients had target vessel revascularization at 6 months. The Tristar stent system produces optimal deployment without the need for routine postdilation and results in optimal clinical outcomes.


Asunto(s)
Estenosis Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents , Ultrasonografía Intervencional , Adulto , Anciano , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA