Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Vasc Specialist Int ; 39: 15, 2023 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-37345461

RESUMEN

The GORE EXCLUDER Conformable abdominal aortic aneurysm (AAA) Endoprosthesis (CEXC), is currently the newest stent-graft system for treating patients with AAA. CEXC is approved for patients with proximal aortic neck angles ≤90° with a ≥15 mm aortic neck length or proximal aortic neck angles ≤60° with ≥10 mm aortic neck length. The present study describes a clinical series of 5 males with AAA, one of whom had a ruptured infrarenal AAA and a 90° proximal aortic neck angle. All patients were treated with 100% technical success using the CEXC device. Dosimetric data were recorded regarding the total kerma-area product and total fluoroscopy time. During the 30-day follow-up, no device migration or failure was detected, whereas type Ib and II endoleaks were observed in two patients. The type Ib endoleak required re-intervention with limb extension placement, and the type II endoleak was treated with lumbar artery embolization. This clinical series showed that CEXC has no technical defects or AAA-related mortality. We also reviewed the current knowledge on CEXC's clinical outcomes, showing promising technical and clinical results in some studies, even outside the instructions for use. CEXC expands the vascular surgeons' armamentarium against hostile neck anatomy, as it is the only repositionable endovascular aneurysm repair device available. Multicenter, long-term outcome studies should confirm the promising preliminary results of our case series and the literature review.

2.
Radiat Prot Dosimetry ; 199(5): 443-452, 2023 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-36782000

RESUMEN

Patients who undergo endovascular aortic aneurysm repair (EVAR) may require prolonged radiation exposure affected by several factors. The objectives of this study were to document fluoroscopy time (FT) during EVAR and identify possible factors that influence it. A retrospective analysis of a 180 patients' database with abdominal infrarenal aortic aneurysms submitted to EVAR during a 7-y period was performed. The FT is evaluated regarding risk factors and comorbidities, graft type and patient-related, clinical and technical parameters. FT's median (interquartile range) was 1011 (698-1500) s. Excluder and C3 Excluder were associated with significantly lower FT values when compared with other grafts. Hypertension, dyslipidemia, age ≥ 70 y, maximum aneurysm diameter ≥ 6 cm and procedure duration ≥2 h resulted in higher FT values. A significantly lower FT was found for the operations performed in the 7th y of the study's period compared with the previous 6 y, mainly because of the use of Excluder or C3 Excluder grafts. However, these grafts did not show any significant difference in FT values during the 7 y. A significant correlation between FT with age and procedure duration was found. Nevertheless, procedure duration is a poor FT predictor in linear and logistic regressions, although is significantly correlated with FT. Dyslipidemia, procedure duration and graft type are independent predictors of FT larger than the median, whereas only the procedure duration is a predictor for FT larger than the 75th percentile value. The identified factors regarding radiation protection issues should be considered when contemplating abdominal aortic aneurysm repair, however, without compromising the procedure's efficacy. Further work is necessary to identify more potential anatomical, clinical and technical factors affecting procedures' complexity and FT and patient radiation dose during EVAR interventions.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Estudios Retrospectivos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Stents , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Aneurisma de la Aorta Abdominal/etiología , Aneurisma de la Aorta Abdominal/cirugía , Factores de Riesgo , Fluoroscopía
3.
Vasc Specialist Int ; 38: 17, 2022 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-35748180

RESUMEN

The ALTO abdominal stent graft system (Endologix Inc., Irvine, CA, USA) is a latest-generation polymer-based device used to treat patients with abdominal aortic aneurysms. The present study describes the first case series of patients with abdominal aortic aneurysms, including two patients with juxtarenal aneurysms, treated using the ALTO stent graft system. Six males were treated using the ALTO device at a single public center. All procedures were uneventful, and the dosimetric results recorded in terms of kerma-area product and fluoroscopy time were similar to those reported in previous studies. At the 1-month follow-up, computed tomography angiography showed no evidence of endoleak, device migration, thrombosis, or structural graft failure. This clinical series demonstrates that the use of the ALTO stent graft system is associated with promising patient outcomes. Lifelong postoperative imaging surveillance may highlight possible late failures and suggest potential graft improvements.

4.
Clin Case Rep ; 9(12): e04988, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34963798

RESUMEN

Complete agenesis of the infra-renal aorta is an extremely rare anatomical variant, and its presence can complicate the accurate interpretation of the aortic sonographic assessment.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA