Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Thorac Cardiovasc Surg ; 71(6): 441-447, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-35817062

RESUMEN

BACKGROUND: This study aimed to compare the short- and long-term outcomes of saphenous vein grafts (SVGs) and in situ left internal thoracic artery (LITA) grafts to the left circumflex artery (LCX) territory. METHODS: This study included 678 patients who underwent LITA-left anterior descending (LAD) + SVG-LCX grafts and 286 patients who underwent right internal thoracic artery (RITA)-LAD + in situ LITA-LCX grafts from January 2002 to December 2020. Short-term and long-term clinical outcomes were compared using inverse probability of treatment weighting adjustment to reduce selection bias. RESULTS: In-hospital mortality was significantly higher for the SVG-LCX group (p = 0.008), whereas deep sternal wound infection was significantly higher in the LITA-LCX group (p = 0.013).Survival rates at 5 and 10 years were 83.12 and 71.45% in the SVG-LCX group, whereas 75.24 and 65.54% in the LITA-LCX group (log-rank p = 0.114). Rates of freedom from cardiac events at 5 and 10 years were 92.82 and 85.24% in the SVG-LCX group, whereas 94.89 and 89.46% in the LITA-LCX group (log-rank p = 0.179).Univariate and multivariate logistic regression analysis showed that proximal severe stenosis was significantly protective against graft dysfunction before discharge (odds ratio, 0.43; 95% confidence interval, 0.23-0.81). CONCLUSION: Deep sternal wound infection was significantly higher for LITA to LCX bypass whereas in-hospital mortality was higher for SVG to LCX. In situ LITA to LCX bypass grafting exhibited similar long-term outcomes with SVG to LCX bypass grafting in adjusted patient cohorts. Proximal severe stenosis of LCX was protective against graft dysfunction.


Asunto(s)
Enfermedad de la Arteria Coronaria , Arterias Mamarias , Infección de Heridas , Humanos , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Vena Safena/trasplante , Constricción Patológica , Resultado del Tratamiento , Estudios Retrospectivos , Grado de Desobstrucción Vascular
2.
Thorac Cardiovasc Surg ; 68(4): 294-300, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-30795029

RESUMEN

BACKGROUND: Aortic enlargement after hemiarch replacement (HAR) for acute type A aortic dissection (AAAD) is a serious problem. We reviewed our experience and analyzed the risk factors for aortic enlargement. METHODS: During April 2005 to December 2017, 364 patients underwent HAR for AAAD. Seventy-three patients fulfilled the inclusion criteria. We analyzed the change in aortic diameter, aortic growth rate, and major adverse aortic events (MAAEs) and their association with luminal communication of the aortic arch. RESULTS: Anastomotic communication, supra-aortic communication (SAC), and distal aortic communication were found in 34 (46.6%), 28 (38.4%), and 20 (27.4%) patients, respectively. The aortic growth rate was high because of the presence of SAC, distal aortic communication, and the number of coexisting aortic communication. Univariate analysis showed that the presence of SAC and an initial aortic diameter > 35 mm at 20 mm distal to the left subclavian artery and at the pulmonary artery bifurcation (PAB) were risk factors for MAAEs. Multivariate analysis showed that SAC and an initial aortic diameter > 35 mm at the PAB were independent risk factors for MAAEs. CONCLUSION: SAC, distal aortic communication, and the number of coexisting aortic communication are significant risk factors for aortic enlargement after HAR for AAAD. SAC and an initial aortic diameter > 35 mm at the PAB are independent risk factors for MAAEs after this procedure.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Complicaciones Cognitivas Postoperatorias/etiología , Enfermedad Aguda , Anciano , Disección Aórtica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aortografía , Angiografía por Tomografía Computarizada , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Cognitivas Postoperatorias/diagnóstico por imagen , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
3.
Thorac Cardiovasc Surg ; 66(3): 227-232, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29462826

RESUMEN

OBJECTIVE: Thoracic prosthetic graft infection is a rare but serious complication with no standard management. We reported our surgical experience on graft-sparing strategy for thoracic prosthetic graft infection. METHODS: This study included patients who underwent graft-sparing surgery for thoracic prosthetic graft infection at Matsubara Tokushukai Hospital in Japan from January 2000 to October 2017. RESULTS: There were 17 patients included in the analyses, with a mean age at surgery of 71.0 ± 10.5 years; 11 were men. In-hospital mortality was observed in five patients (29.4%). CONCLUSIONS: Graft-sparing surgery for thoracic prosthetic graft infection is an alternative option particularly for early graft infection after hemiarch replacement.


Asunto(s)
Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular/efectos adversos , Desbridamiento , Epiplón/cirugía , Infecciones Relacionadas con Prótesis/cirugía , Administración Intravenosa , Anciano , Anciano de 80 o más Años , Antibacterianos/administración & dosificación , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/microbiología , Implantación de Prótesis Vascular/mortalidad , Desbridamiento/efectos adversos , Desbridamiento/mortalidad , Drenaje , Femenino , Mortalidad Hospitalaria , Humanos , Japón , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/mortalidad , Estudios Retrospectivos , Factores de Riesgo , Irrigación Terapéutica , Factores de Tiempo , Resultado del Tratamiento
4.
Thorac Cardiovasc Surg ; 66(3): 222-226, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29078229

RESUMEN

BACKGROUND: As the results of acute type A aortic dissection repair have improved, late reoperation for residual dissection has become increasingly important. We report our experience of graft replacement via extended approaches after a previous acute type A aortic dissection repair. METHODS: From April 2003 to September 2016, 17 patients underwent reoperation via extended (repeat median sternotomy plus left thoracotomy) approaches after a previous repair of an acute type A aortic dissection at the Matsubara Tokushukai Hospital in Japan and were included in the analyses (males, 16; mean age at surgery, 60.0 ± 9.3 years). RESULTS: The postoperative stroke and in-hospital mortality rates were 0 and 5.9%, respectively. CONCLUSION: Extended approach after a previous acute type A aortic dissection repair showed acceptable outcomes.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Procedimientos Endovasculares , Esternotomía , Toracotomía , Enfermedad Aguda , Anciano , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/mortalidad , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Japón , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Esternotomía/efectos adversos , Esternotomía/mortalidad , Toracotomía/efectos adversos , Toracotomía/mortalidad , Factores de Tiempo , Resultado del Tratamiento
5.
J Card Surg ; 32(2): 110-113, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28105641

RESUMEN

OBJECTIVE: Antegrade cerebral perfusion during aortic arch surgery plays an important role in improving postoperative neurological outcomes. We report our experience using innominate artery cannulation for arterial perfusion during aortic arch surgery. METHODS: From January 2008 to December 2015, 159 patients underwent aortic arch surgery using innominate artery perfusion and were included in the study analysis (mean age, 71.4 ± 9.1 years; male, 120). RESULTS: Total arch replacement was performed in 84.1% of all patients. The incidence of postoperative stroke was 2.5%, with an overall in-hospital mortality rate of 2.5%. CONCLUSIONS: Innominate artery perfusionis a safe and useful technique for aortic arch surgery.


Asunto(s)
Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Tronco Braquiocefálico/cirugía , Cateterismo Periférico/métodos , Circulación Cerebrovascular/fisiología , Perfusión/métodos , Anciano , Aneurisma de la Aorta Torácica/cirugía , Procedimientos Endovasculares/métodos , Femenino , Estudios de Seguimiento , Humanos , Hipotermia Inducida/métodos , Periodo Intraoperatorio , Masculino , Monitoreo Intraoperatorio/métodos , Estudios Retrospectivos , Resultado del Tratamiento
6.
Kyobu Geka ; 69(13): 1077-1080, 2016 Dec.
Artículo en Japonés | MEDLINE | ID: mdl-27909276

RESUMEN

An 85-year-old woman was hospitalized by emergency for an acute Stanford type A aortic dissection. Computed tomography showed a primary entry on the ascending aorta and pericardial effusion. Although her hemodynamics was unstable due to cardiac shock, her family wished no open surgery considering her age and frailty. A couple of days later, her condition became stabilized with antihypertensive therapy. Since the dissection was limited within the ascending aorta, closure of the entry with the stentgraft was considered appropriate and much less invasive as compared with an open surgery. After obtaining informed consent with her family, thoracic endovascular aortic repair was performed with Gore C-TAG with 2-debranch. The procedure was completed without complications and the entry closure was confirmed by aortography. Her postoperative course was uneventful. Her physical activity restored to the preoperative level and she was discharged.


Asunto(s)
Aorta/cirugía , Enfermedad Aguda , Anciano de 80 o más Años , Aorta/diagnóstico por imagen , Femenino , Humanos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
7.
Artículo en Inglés | MEDLINE | ID: mdl-35640541

RESUMEN

OBJECTIVES: This study aimed to examine very-long-term outcomes of a mechanical valve at the mitral position. METHODS: This study included all patients who underwent mitral valve replacement (MVR) using a mechanical valve including urgent operation at the Department of Cardiovascular Surgery, Hyogo Brain and Heart Center, Himeji, from January 1987 to December 2015. RESULTS: Five hundred and eighty-three patients (277 men [47.51%]; age, 61 [54-67] years) were included in this study. The implanted valve models were as follows: SJM, 221 (37.91%); ATS, 35 (6.00%); On-X, 68 (11.66%); and Carbomedics 194, (33.28%).The median clinical follow-up duration was 13.3 (7.4-19.6) years. The survival rates at 10, 15, 20 and 25 years were 81.42%, 69.27%, 56.34% and 45.03%, respectively. Thromboembolism was observed in 38 patients, and the linearized ratio for each event was 0.626%/patient-year [95% confidence interval (CI), 0.443-0.859%]. Intracranial haemorrhage and gastrointestinal bleeding were observed in 26 and 9 patients, and the linearized ratio for each event was 0.425%/patient-year (95% CI, 0.277-0.006%) and 0.145%/patient-year (95% CI, 0.067-0.276%), respectively. Major paravalvular leak was observed in 32 patients, and the linearized ratio was 0.532%/patient-year (95% CI, 0.364%-0.751%). The cumulative incidence rate of major paravalvular leak at 10, 15, 20 and 25 years was 3.7%, 5.6%, 6.4% and 10.4%, respectively. Multivariable Cox regression analysis revealed that repeated MVR and male gender were associated with major paravalvular leak. CONCLUSIONS: Male gender and repeated MVR were risk factors for paravalvular leak after mechanical MVR. Paravalvular leak could have occurred regardless of postoperative period even at 25 years after implantation. Lifelong clinical follow-up is considered necessary.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Tromboembolia , Válvula Aórtica/cirugía , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Complicaciones Posoperatorias/epidemiología , Reoperación/efectos adversos , Factores de Riesgo , Tromboembolia/epidemiología
8.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-34875043

RESUMEN

OBJECTIVES: This study was conducted to examine the incidence and modes of the bioprosthetic valve failure of the porcine valve in the mitral position and compare them with those of the pericardial valve. METHODS: This study included 240 patients (116 men [48.3%]; mean age, 74.87 ± 6.61 years) who underwent mitral valve replacement using the St. Jude Medical Epic bioprosthesis (Epic) (N = 125) or Carpentier-Edwards Perimount (CEP) pericardial valve (N = 115) from January 2000 to December 2020. RESULTS: The median clinical follow-up durations in the Epic and CEP groups were 54.5 months (range, 0-111 months) and 81.5 months (range, 0-194 months), respectively. Structural valve degeneration (SVD) was observed in 9 patients (7.2%) in the Epic group and 11 patients (9.6%) in the CEP group. The rates of freedom from SVD at 3, 5 and 7 years were 97.7%, 90.5% and 75.5% in the Epic group and 100.0%, 96.1% and 90.0% in the CEP group, respectively. SVD reoperation was performed for 7 patients (5.6%) in the Epic group and 6 patients (5.2%) in the CEP group. The rates of freedom from SVD reoperation at 3, 5 and 7 years were 97.7%, 90.5% and 75.5% in the Epic group and 100%, 96.1% and 90.0% in the CEP group, respectively. Epic SVD was predominantly due to leaflet tearing, whereas CEP SVD was predominantly due to leaflet calcification and adhesion to the subvalvular apparatus. CONCLUSIONS: SVD of the porcine valve was predominantly due to leaflet tearing. The rate of reoperation for SVD was slightly higher for the porcine valve in the mitral position than for the pericardial valve at adjusted survival analysis.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Mitral , Anciano , Anciano de 80 o más Años , Animales , Bioprótesis/efectos adversos , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Válvula Mitral/cirugía , Falla de Prótesis , Reoperación , Porcinos
9.
Surg Infect (Larchmt) ; 22(7): 713-721, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33434446

RESUMEN

Background: Mycotic aneurysms (MAs) are relatively rare but life-threatening. Some recent reports have described the use of endovascular therapy for their treatment; however, this still is a controversial treatment, and a definite target population has not been determined. Methods: We performed surgery on 34 patients with MAs from March 2005 to March 2019. Twenty patients who underwent open surgery (OS) first comprised the OS group, and 14 patients who underwent endovascular therapy first comprised the stent-graft (SG) group. We analyzed between-group differences, long-term outcomes, and risk factors for death retrospectively. Patients in the OS group had a higher initial white blood cell count than those in the SG group (p = 0.047). The SG group had more patients with a low albumin concentration (≤2.0 mg/dL) than did the OS group (p = 0.026). Results: There were no significant differences in the operative mortality rates between the groups (p = 0.773). Additional procedures were required more often in the SG than the OS group (p = 0.0013). The overall survival rate as estimated by the Kaplan-Meier method was 88% at 1 month, 67% at 1 year, 57% at 3 years, and 45% at 10 years. In the univariable analysis, chronic obstructive pulmonary disease (COPD) was a risk factor for death (p = 0.003). Conclusions: Endovascular therapy for MAs produced reasonable outcomes when patient selection was based on the activity level, nutritional condition, and degree of inflammation. Endovascular therapy may become an option for patients with a low albumin concentration or COPD despite the fact that additional procedures may be needed.


Asunto(s)
Aneurisma Infectado , Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma Infectado/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Humanos , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento
10.
Ann Vasc Dis ; 14(4): 362-367, 2021 Dec 25.
Artículo en Inglés | MEDLINE | ID: mdl-35082941

RESUMEN

Objectives: Distal stent graft-induced new entry (dSINE), defined as a new tear caused by a stent graft, has been increasingly observed following total arch replacement using frozen elephant trunk (FET) for aortic dissection. We aimed to investigate the incidence and treatment of dSINE after the use of FET. Methods: This retrospective study evaluated 70 patients who underwent total arch replacement using FET for aortic dissection between August 2014 and March 2020. They were followed up for at least 6 months postoperatively. Between-group comparisons were performed between those who did and did not develop dSINE. The risk factors for the development of dSINE and the treatment of dSINE were analyzed. Results: dSINE occurred postoperatively in nine patients (12.9%) with a median time frame of 17.7±11.7 months. The incidence of dSINE did not differ significantly according to classification, phase of dissection, or oversizing. All patients in the dSINE group developed enlargement of the false lumen. dSINE closure was successfully achieved without complications via thoracic endovascular aortic repair (TEVAR) in all patients. Conclusion: No independent factors predicting the development of dSINE were noted in this study. Additional TEVAR for dSINE provides good results and achieves false lumen thrombosis in the thoracic aorta, with no complications.

11.
Vasc Endovascular Surg ; 53(3): 199-205, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30558509

RESUMEN

OBJECTIVES:: Patients with chronic aortic dissection often require repeat interventions due to enlargement of the pressurized false lumen or disseminated intravascular coagulation even after additional thoracic endovascular aortic repair (TEVAR) to occlude the entry tear. Residual false lumen flow can persist even after performing the candy-plug technique or branched stent-graft placement in some cases. We have devised a new method for false lumen closure. METHODS:: From December 2010 to May 2017, 5 patients (mean age: 57 [13] years, range: 43-77 years) with chronic dissection at the aortic arch and descending aorta, who underwent initial TEVAR, required additional treatment. Using an open surgical approach, the endograft was fixed with an outer felt under cardiopulmonary bypass after the endograft with stent was expanded by fenestration. The false lumen was closed using this procedure, and the aortotomy was repaired by direct closure in 2 cases and by graft replacement in 3 cases. RESULTS:: No major operative complications occurred, such as respiratory failure or paraplegia. Postoperative enhanced computed tomography (CT) images showed that the false lumen flow disappeared in all cases. All patients were discharged under normal conditions. They were all followed up and their CT did not indicate any complications for a mean of 33.6 (20.3) months. CONCLUSIONS:: Our combined procedure was effective and provided a higher success rate compared with endovascular therapy alone. This staged treatment approach, using a combination of TEVAR and false lumen closure, is less invasive compared with open surgery alone and may represent a valid treatment option for chronic type B dissection.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Adulto , Anciano , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Disección Aórtica/fisiopatología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Aneurisma de la Aorta Torácica/fisiopatología , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Enfermedad Crónica , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Flujo Sanguíneo Regional , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento
12.
Case Rep Surg ; 2019: 1628157, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31179150

RESUMEN

A 56-year-old man presenting with massive melena and loss of consciousness was diagnosed with an infected thoracoabdominal aneurysm, an aortoduodenal fistula, and Leriche syndrome following an evaluation by computed tomography. Emergency surgery for uncontrolled infection included the reconstruction of the superior mesenteric and bilateral renal arteries using a four-branched graft. The aortoduodenal fistula was resected after omental filling, and an enterostomy was performed for feeding. Intestinal reconstruction was performed in two stages. The patient was discharged on postoperative day 48 and was without evidence of recurrence at 23 months postoperatively.

13.
J Cardiol ; 71(5): 488-493, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29174599

RESUMEN

BACKGROUND: The timing of surgical repair for ventricular septal perforation (VSP) is important because patients are susceptible to bleeding from fragile myocardial tissue or residual shunt during the acute phase of acute myocardial infarction (AMI). This study aimed to assess the results of delayed surgery for VSP performed 2 weeks after AMI. METHODS: In total, 24 consecutive postinfarction patients with VSP (mean age: 72.6±10.4 years; 13 males) underwent operation between May 2003 and June 2016. We postponed surgery during the acute phase and performed an elective surgery if the patient could wait for 2 weeks with support from intra-aortic balloon pumping (IABP) and respiratory management. If we could not control heart failure and organ function worsened during that period, we performed emergency surgery. Postoperative outcomes included complications, 30-day mortality rate, long-term hospital death, reoperation rate, and risk factors for hospital mortality. We examined whether organ function was maintained by delaying the surgery. RESULTS: Of the 24 patients, 11 (45.8%) required emergency surgery, and 13 (54.2%) could wait 2 weeks for surgery. The average time from AMI onset to diagnosis of VSP was 4.5±1.6 days, and the average time from VSP diagnosis to surgery was 9.0±6.0 days; 5 patients (20.8%) required resurgery for VSP due to residual shunt, recurrent VSP, or pseudoaneurysm of the left ventricle. The 30-day mortality rate was 4.2% (1 patient), and long-term hospital mortality rate was 12.5% (3 patients). Organ function was maintained in 10 patients (76.9%) who underwent elective surgery, and organ dysfunction was not advanced by delaying the surgery. CONCLUSIONS: We could delay surgery for an average of 9 days from VSP onset by means of IABP or respiratory management without the deterioration of organ function. The 30-day mortality and long-term outcome were favorable.


Asunto(s)
Insuficiencia Cardíaca/complicaciones , Ventrículos Cardíacos/fisiopatología , Contrapulsador Intraaórtico/efectos adversos , Infarto del Miocardio/complicaciones , Rotura Septal Ventricular/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Tiempo de Tratamiento , Resultado del Tratamiento , Rotura Septal Ventricular/complicaciones
14.
Ann Thorac Surg ; 103(6): 1922-1926, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27863729

RESUMEN

BACKGROUND: Kommerell diverticulum is a rare aortic arch anomaly. The indications for operative intervention and surgical strategy are still controversial. The standard surgical procedure at our institution is total aortic arch plus descending aortic replacement using anterolateral thoracotomy with partial sternotomy. The aberrant subclavian artery is reconstructed anatomically or extraanatomically. METHODS: From 2002 to 2014, 6 patients (1 woman), aged 55 to 78 years, underwent graft replacement through an anterolateral thoracotomy or anterolateral thoracotomy with a partial sternotomy approach for Kommerell diverticulum. All patients underwent graft replacement of the descending aorta or total aortic arch plus descending aorta in addition to aberrant subclavian artery reconstruction. RESULTS: No hospital deaths or major complications occurred. Recurrent nerve injury developed at discharge in 1 patient. All patients were well during the follow-up period (range, 11 to 116 months). CONCLUSIONS: Kommerell diverticulum and its associated symptoms were surgically treated with acceptable outcomes.


Asunto(s)
Aneurisma/cirugía , Aorta Torácica/anomalías , Arteria Subclavia/anomalías , Anciano , Aneurisma/complicaciones , Aneurisma/diagnóstico por imagen , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Anomalías Cardiovasculares/complicaciones , Anomalías Cardiovasculares/diagnóstico por imagen , Anomalías Cardiovasculares/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Esternotomía/métodos , Arteria Subclavia/diagnóstico por imagen , Arteria Subclavia/cirugía , Toracotomía/métodos , Tomografía Computarizada por Rayos X
15.
Interact Cardiovasc Thorac Surg ; 24(5): 708-713, 2017 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28329046

RESUMEN

OBJECTIVES: Spinal cord protection during thoracoabdominal aortic surgery is challenging for surgeons. We performed thoracoabdominal replacement using a strategy for maintaining spinal cord perfusion pressure. Here, we report our experience with this procedure and the surgical outcomes. METHODS: Between January 2000 and December 2014, 130 patients [male: 91 (74.6%), female: 39 (25.4%); mean age: 66.6 ± 12.8 years] underwent thoracoabdominal replacement using cardiopulmonary bypass at Hiroshima Shimin Hospital, Japan. The surgical outcomes of these patients were analysed. RESULTS: The in-hospital mortality rate of all patients was 2.5%. The incidence of postoperative paraplegia was 3.8%. Aortic event-free survival rates at 1, 3 and 5 years were 98.2%, 93.9% and 80.7%, respectively. CONCLUSIONS: The present study suggests that our strategy for maintaining spinal cord perfusion pressure provides acceptable outcomes.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Cuidados Intraoperatorios/métodos , Complicaciones Intraoperatorias/prevención & control , Perfusión/métodos , Complicaciones Posoperatorias/prevención & control , Isquemia de la Médula Espinal/prevención & control , Médula Espinal/irrigación sanguínea , Anciano , Aneurisma de la Aorta Torácica/diagnóstico , Implantación de Prótesis Vascular/efectos adversos , Supervivencia sin Enfermedad , Femenino , Mortalidad Hospitalaria/tendencias , Humanos , Incidencia , Complicaciones Intraoperatorias/epidemiología , Japón/epidemiología , Masculino , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Isquemia de la Médula Espinal/epidemiología , Isquemia de la Médula Espinal/etiología , Tasa de Supervivencia/tendencias , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
16.
Interact Cardiovasc Thorac Surg ; 24(3): 443-449, 2017 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28025311

RESUMEN

Objectives: There are various treatment strategies for chronic-type B aortic dissection involving the aortic arch. Our aim was to review our surgical experience in the anterolateral thoracotomy with the partial sternotomy approach for chronic-type B aortic dissection involving the aortic arch. Methods: From January 2000 to October 2015, 39 patients underwent the single-stage open surgery for chronic-type B aortic dissection involving the aortic arch using the anterolateral thoracotomy with partial sternotomy approach. Results: Among the 39 patients, 32 were men (82.1%; mean age at surgery, 61.3 ± 11.9 years), with a mean dissecting aortic aneurysm diameter of 50.21 ± 12.20 mm; 28 patients (71.8%) had patent false lumens of the descending aorta. The median interval from dissection occurrence until surgery was 34.05 ± 52.34 months. Twenty-one patients underwent descending aortic replacement plus total aortic arch replacement and 18 underwent descending aortic replacement (plus partial aortic arch replacement). Overall in-hospital mortality and postoperative stroke rates were 5.1% (2 patients) and 10.3% (4 patients), respectively. Survival rates at 1, 3 and 5 years were 94.7%, 94.7% and 90.2%, respectively. Aortic event-free rates at 1, 3 and 5 years were 90.9%, 90.9% and 80.2%, respectively. Conclusions: The anterolateral thoracotomy with partial sternotomy approach is a useful surgical procedure with acceptable outcomes for chronic-type B aortic dissection cases involving the aortic arch, when aortic remodelling using thoracic endovascular aortic repair cannot be performed.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Esternotomía/métodos , Toracotomía/métodos , Disección Aórtica/diagnóstico , Disección Aórtica/mortalidad , Aneurisma de la Aorta Torácica/diagnóstico , Aneurisma de la Aorta Torácica/mortalidad , Enfermedad Crónica , Femenino , Mortalidad Hospitalaria/tendencias , Humanos , Japón/epidemiología , Masculino , Persona de Mediana Edad , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
17.
Gen Thorac Cardiovasc Surg ; 65(6): 358-360, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27259859

RESUMEN

Prosthetic valve fracture is a serious complication and may arise in patient post-valve replacement. We experienced an outlet strut fracture and leaflet escape of a Bjork-Shiley convexo-concave valve. We performed an emergency redo mitral valve replacement and successfully retrieved the fractured strut and escaped leaflet from superficial femoral artery and the abdominal aorta. The patient showed an uneventful postoperative recovery.


Asunto(s)
Prótesis Valvulares Cardíacas/efectos adversos , Estenosis de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Complicaciones Posoperatorias , Ecocardiografía , Humanos , Masculino , Persona de Mediana Edad , Estenosis de la Válvula Mitral/diagnóstico , Diseño de Prótesis , Falla de Prótesis , Reoperación , Tomografía Computarizada por Rayos X
18.
Ann Thorac Surg ; 101(4): 1569-71, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27000575

RESUMEN

A 78-year-old man who had undergone operation for acute type A aortic dissection presented with dyspnea and shock. Chest computed tomography revealed pulmonary embolism. Minimally invasive cardiac surgery was performed through a right fourth intercostal skin incision using cardiopulmonary bypass through the right femoral artery and vein. The right pulmonary artery below the superior vena cava was incised vertically, and the thrombus was extracted directly by balloon catheter. The patient was weaned off cardiopulmonary bypass uneventfully. The postoperative course was also uneventful. In redo cardiac surgery, pulmonary embolectomy through minimally invasive right thoracotomy can be easily performed, with quick recovery.


Asunto(s)
Implantación de Prótesis Vascular/efectos adversos , Puente Cardiopulmonar/métodos , Embolectomía/métodos , Embolia Pulmonar/etiología , Embolia Pulmonar/cirugía , Toracotomía/métodos , Anciano , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/métodos , Ecocardiografía Transesofágica/métodos , Urgencias Médicas , Estudios de Seguimiento , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Embolia Pulmonar/diagnóstico por imagen , Radiografía , Reoperación/métodos , Medición de Riesgo , Resultado del Tratamiento
20.
Gen Thorac Cardiovasc Surg ; 64(12): 722-727, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27485247

RESUMEN

BACKGROUND: Hemiarch replacement for acute type A aortic dissection is less invasive than total arch replacement but involves increased risk of late aortic arch dilation because of patent false lumen of the aortic arch. If we can predict this risk, it may be a valuable prognostic indicator for selecting surgical procedures for acute type A aortic dissection. METHODS: We reviewed our surgical experience to predict patent false lumen. From January 2009 to November 2014, we performed 108 hemiarch replacement procedures for acute type A aortic dissection that had patent false lumen of the ascending aortic arch. We identified 56 patients who had preoperative and postoperative contrast-enhanced computed tomography. Patients' preoperative characteristics, preoperative and postoperative contrast-enhanced computed tomography findings, intraoperative findings and postoperative course were investigated. RESULTS: Of the 56 patients, 32 (57.1 %) were men and their mean age at surgery was 63.7 ± 11.8 years. Overall in-hospital mortality rate was 7.1 % (4 patients). According to postoperative imaging findings, 56 patients were classified into two groups: group A (39 patients), with patent false lumen, and group B (17 patients), with thrombosed false lumen. Logistic regression analysis revealed that brachiocephalic artery dissection and no tear resection contributed to postoperative patent false lumen of the aortic arch more strongly than did other factors. CONCLUSIONS: Brachiocephalic artery dissection and no tear resection are potential predictors of patent false lumen of the aortic arch after hemiarch replacement.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Complicaciones Posoperatorias/epidemiología , Disección Aórtica/diagnóstico , Disección Aórtica/mortalidad , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico , Femenino , Mortalidad Hospitalaria/tendencias , Humanos , Incidencia , Japón , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Pronóstico , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA